EXHAUST FANS CUD & CUB UPBLAST FANS

Similar documents
Commercial Fans & Dampers

Wholesale Ventilation Products

Belt Drive - Centrifugal Up-Blast Fans. Measurements. Motor Availability. HP Open 2 Speed Open 2 Speed. 1/4 na na na. 1/3 na na na 1/2 3/4 1 1/2.

FKUB Belt Drive - Centrifugal Up-Blast Fans

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Models VUDK and VUBK

CENTRIFUGAL WALL EXHAUSTERS Models VWDK and VWBK

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

MODELS STXD & STXDe DIRECT DRIVE CENTRIFUGAL ROOF EXHAUSTERS

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Industry best 5 year fan housing warranty, 1 year motor warranty

Centrifugal Upblast Power Roof Ventilators

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VQBL

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

Centrifugal Spun Aluminum Products

Industry best 5 year fan housing warranty, 1 year motor warranty

DESIGN GUIDELINES FANS PAGE 1 of 7

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

MODEL CTB TUBULAR CENTRIFUGAL INLINE BELT DRIVEN FAN

MODELS UBB & UBX UPBLAST PROPELLER ROOF EXHAUSTERS BELT AND DIRECT DRIVE

MODEL UBSRD REMOTE DRIVE UPBLAST PROPELLER ROOF EXHAUSTER

Centrifugal Spun Aluminum Products

Centrifugal Spun Aluminum Products

MODEL NBRTD BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Utility Sets Standard Design Features Standard design features common to all Class I and Class II fans

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Roof Upblast and Sidewall Exhaust

Commercial & Industrial Ventilation Complete Line of Sustainable Products

Roof Upblast and Sidewall Exhaust

Filtered Kitchen Supply Packaged Ventilator

EcoWatt Products. Advancing Ventilation

MODEL LUBK (Belt Drive) UPBLAST PROPELLER ROOF EXHAUSTERS

Twin City Fan & Blower

INLINE CENTRIFUGAL DUCT FANS Direct and Belt Driven Models ZIDK and ZIBK

Twin City Fan & Blower

Centrifugal Filtered Supply Roof Blowers

Centrifugal Exhaust Fans Series C. Roof Upblast and Sidewall

TURNING AIR INTO SOLUTIONS. LOW PROFILE UPBLAST PROPELLER ROOF VENTILATORS. LUD/LUB (Standard) LUBMO (Motor Out of Airstream) LUBSH (UL Smoke & Heat)

SPUN ALUMINUM POWER ROOF AND WALL VENTILATORS

MODELS HREB-C & HRED-C HOODED PROPELLER ROOF EXHAUST FANS

MODELS HRSB & HRSD HOODED PROPELLER ROOF SUPPLY FANS

forward curved inline duct blowers

Industry best 5 year fan housing warranty, 1 year motor warranty

SECTION HVAC POWER VENTILATORS

Advancing Ventilation

Air Moving Solutions. VENTILATING SETs BCV BCVU5 BCVU2 BCVSH BAV FCV

MODEL CWD DIRECT DRIVE CENTRIFUGAL SIDEWALL EXHAUSTER

Inline and Roof Mounted Fans

Tubular Centrifugal Fans

The Industrial Choice. Model SCDD Direct Drive. Model SCBD Belt Driven SQUARE INLINE FANS. Direct Drive & Belt Driven Model SCDD / SCBD

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

Centrifugal Ventilators Direct-Drive Upblast Centrifugal Roof & Wall Ventilators

Propeller Hooded Roof Fans

Propeller Upblast Roof Fans

TURNING AIR INTO SOLUTIONS. UTILITY SETS DCV BCV BCVR BCVSH BAV DDF FCV

Propeller Fan BE Series

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Belt Drive Centrifugal Roof Exhauster Model PV

Tamper Proof Downblast Centrifugal Exhaust Ventilators Page

MODEL TXB BELT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Centrifugal Utility Fans - SFD/SFB

belt drive utility sets vent-pak series models vp-bi & fc january 2007 vp 1.07

FILTERED SUPPLY CENTRIFUGAL Belt Drive

BELT DRIVEN CENTRIFUGAL ROOFTOP FILTERED SUPPLY FAN

Twin City Fan & Blower

UTILITY BLOWERS. Models: BIUB / BIUBR / BIUBSH BAUB / DFC / FCUB. The Industrial Choice.

Power Roof and Wall Ventilators

SQUARE INLINE CENTRIFUGAL FANS

MODEL KSF BELT DRIVE CENTRIFUGAL FILTERED ROOF SUPPLY FAN

Tubular Centrifugal Inline Fans Page Introduction... 2 Construction Features... 3 Specification and Dimension Data TCN-D (Inline Fan- Direct

Mixed-Flow Blowers Page Specifications and Dimension Data Performance Data Sound Data

Safety disconnect. switch is optional. Belt drive with adjustable motor pulley provides flexibility to match operating requirements.

LINEA Low Discharge Roof Exhausters

Centrifugal Filtered Supply Fans

SECTION CENTRIFUGAL HVAC FANS

Twin City Fan & Blower

Twin City Fan & Blower

Fumex. Upblast Roof Exhauster Technical Specifications BULLETIN FX17

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

VANEAXIAL & TUBEAXIAL FANS

TURNING AIR INTO SOLUTIONS. UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS DCRU DCRUR DCRW DCRWR BCRU BCRUR BCRW BCRWR BCRUSH

TURNING AIR INTO SOLUTIONS. DIRECT DRIVE EXHAUST & SUPPLY PANEL FANS. Model TCPE

MODEL TDB TUBEAXIAL INLINE BELT DRIVEN DUCT FAN

UPBLAST ROOF, WALL & KITCHEN EXHAUSTERS

K SERIES SIDEWALL PROPELLER FANS

The Industrial Choice. Model BSHD Direct Drive LOW PROFILE HOODED PROPELLER ROOF VENTILATORS. Models BSHD / BSHB

Upblast Power Roof Ventilators Types J, JTE, JT, HSE, & HS

Tube Axial Fan Page Specifications & Dimension Data Performance Data

TURNING AIR INTO SOLUTIONS. CENTRIFUGAL ROOFTOP EXHAUST FANS LOW PROFILE HOODED & LOUVERED DCLH BCLH DCLP BCLP

Inline Fans [ 14 ] * UL is optional and must be specified.

Type VA Vanax Fans. Models VA, VAD, & VAB

SECTION AXIAL HVAC FANS

Low Silhouette Power Roof Ventilator Propeller

Defining Innovation. backward curved FANs

AMCA Seal Assures rating of Sound and Air performance. 2 year fan housing warranty, 1 year motor warranty

Electric Coil [Make-Up Air / Displacement Ventilation / Space Heating] System

Centrifugal Upblast Roof Exhausters, EVU-Series

MODELS CSF & LSF BELT DRIVE CENTRIFUGAL FILTERED SUPPLY FANS

The Industrial Choice. Model BD40C UPBLAST AXIAL ROOF VENTILATORS. Macheta Airfoil Design. Model BD40C

TUBULAR CENTRIFUGAL INLINE FANS

Transcription:

EXHAUST FANS CUD & CUB UPBLAST FANS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing Blades & inlets fabricated from aluminum Easy access to motor compartment Fully ventilated motor cooling Direct drive capacities to 3,400 cfm Belt drive capacities to 17,725 cfm Custom Fan Solutions rm

CUD DIRECT DRIVE UPBLAST FANS FEATURES & BENEFITS Suitable for roof or wall mount Backward inclined, non overloading wheels Spun aluminum housing for weather resistant durability Fully enclosed drive compartment protects motor from airborne contaminants Fully ventilated motor cooling compartment for long motor life Quick release latches for easy access to motor compartment Blades and inlets fabricated from aluminum Variable speed control (standard on single phase units only) Disconnect switch Fully welded leak proof grease drain (except for model CUD 10) 300 F max. temperature rating (except for model CUD 10) Available in the following voltages: o 115V 1 phase o 208/230 460V 3 phase ACCESSORIES / OPTIONS Gravity damper Motorized damper Bird screen Wall mount brackets Roof curb (vented or non vented) W D D HT F CURB (OPTIONAL) B GREASE DRAIN E 20 GAUGE STEEL CONSTRUCTION R 3" FLANGE RO C DIMENSIONS IN INCHES* MODEL HT W B C D E F R RO WT (LBS) DAMPER SQUARE MANUFACTURE CODE CUD 10 14.5 17.8 2 19.0 17.5 12 9.5 8.1 13 30 12 DU10H CUD 12 18.0 22.0 2 19.0 17.5 12 14.5 10.6 13 40 12 DU12H CUD 30 25.3 25.5 2 21.0 19.5 12 18.5 12.1 16 50 15 DU30H CUD 33 25.3 25.5 2 21.0 19.5 12 18.5 12.1 16 50 15 DU33H CUD 50 27.3 28.9 2 21.0 19.5 12 21.5 13.3 16 55 15 DU50H CUD 85 30.5 31.9 2 24.8 23.0 12 23.0 14.9 20 60 19 DU85H *DO NOT USE FOR CONSTRUCTION 2 CONSULT FACTORY FOR CERTIFIED PRINTS

CUD DIRECT DRIVE UPBLAST FANS PERFORMANCE MTR CUBIC FEET PER MINUTE RPM HP SONE BHP 0 SP 0.125 SP 0.25 SP 0.375 SP 0.50 SP 0.625 SP 0.75 SP 0.875 SP 1 SP CUD 103 1000 0.08 2.5 0.02 335 263 170 1100 0.08 3.1 0.02 369 304 226 112 1200 0.08 4.0 0.03 402 343 277 192 1300 0.08 4.9 0.04 436 382 322 252 160 1400 0.08 5.9 0.05 469 419 365 304 232 124 1500 0.08 7.1 0.06 503 457 407 353 290 215 99 1600 0.08 7.8 0.07 537 493 447 398 343 280 204 CUD 12 925 0.18 3.2 0.03 472 367 223 1025 0.18 3.9 0.04 523 431 310 174 1125 0.18 4.8 0.06 574 491 390 266 141 1225 0.18 5.8 0.08 625 550 463 353 240 122 1325 0.18 6.9 0.10 676 608 531 437 330 227 1425 0.18 8.2 0.12 727 664 594 514 417 319 223 CUD 30 1000 1/4 5.5 0.06 788 692 583 1100 1/4 6.5 0.08 866 780 687 571 1200 1/4 7.7 0.11 945 867 784 687 570 1300 1/4 8.9 0.13 1024 951 876 793 697 583 1400 1/4 10.3 0.17 1103 1035 966 894 809 712 606 1500 1/4 11.8 0.21 1182 1119 1055 988 915 833 737 638 1600 1/4 13.4 0.25 1261 1201 1143 1080 1016 942 864 771 677 CUD 33 1125 1/3 5.8 0.09 875 795 698 591 450 1225 1/3 6.8 0.12 953 879 794 701 594 435 1325 1/3 8.0 0.15 1030 963 888 803 713 603 428 1425 1/3 9.3 0.19 1108 1045 979 901 821 730 622 435 1525 1/3 10.7 0.23 1186 1127 1067 996 922 847 757 651 474 1625 1/3 12.1 0.28 1264 1209 1153 1090 1020 950 876 791 688 1725 1/3 12.9 0.33 1342 1290 1237 1181 1116 1051 984 910 831 CUD 50 1070 1/2 8.2 0.13 1397 1296 1193 1074 926 736 1170 1/2 9.7 0.17 1528 1436 1343 1246 1122 979 801 1270 1/2 11.4 0.22 1658 1573 1489 1400 1301 1185 1047 882 1370 1/2 13.2 0.28 1789 1710 1632 1551 1469 1366 1259 1128 975 1470 1/2 15.1 0.34 1919 1846 1773 1699 1622 1542 1442 1340 1217 1570 1/2 16.6 0.42 2050 1981 1913 1844 1773 1701 1619 1525 1430 1670 1/2 18.0 0.50 2181 2116 2052 1987 1922 1854 1786 1704 1615 CUD 85 1025 3/4 10.0 0.17 2135 2008 1871 1722 1546 1339 1047 1125 3/4 11.7 0.23 2344 2228 2109 1974 1831 1667 1474 1224 1225 3/4 13.6 0.29 2552 2446 2338 2218 2094 1955 1804 1626 1409 1325 3/4 15.5 0.37 2760 2662 2563 2458 2343 2228 2094 1954 1790 1425 3/4 17.7 0.46 2969 2878 2785 2693 2587 2480 2373 2244 2114 1525 3/4 20.0 0.57 3177 3092 3006 2920 2827 2727 2627 2525 2404 1625 3/4 22.0 0.68 3385 3306 3225 3144 3063 2969 2875 2782 2685 3

CUB BELT DRIVE UPBLAST FANS FEATURES & BENEFITS Suitable for roof or wall mount (up to model CUB24/2HP) Backward inclined, non overloading wheels Spun aluminum housing for weather resistant durability Fully ventilated motor cooling compartment for long motor life Quick release latches for easy access to motor compartment Blades and inlets fabricated from aluminum Variable pitch motor pulley allows for field adjustment and system balancing High efficiency wheels and low tip speeds result in quiet operation Disconnect switch Fully welded leak proof grease drain Vibration isolation 300 F max. temperature rating Available in the following voltages: o 115 208/230V 1 phase o 208/230 460V 3 phase o 208/230V 1 phase o 575V 3 phase ACCESSORIES / OPTIONS Gravity damper (UL705 only) Motorized damper (UL705 only) Bird screen (UL705 only) Wall mount brackets Roof curb (vented or non vented) W D D HT F CURB (OPTIONAL) B R RO GREASE DRAIN E 20 GAUGE STEEL CONSTRUCTION 3" FLANGE C DIMENSIONS IN INCHES* MODEL HT W B C D E F R RO WT (LBS) DAMPER SQUARE MANUFACTURE CODE CUB 11 25.3 27.3 2 21.0 19.5 22 18.5 12.1 16 105 15.0 BDU11 CUB 13 27.3 30.3 2 21.0 19.5 20 21.5 13.3 16 120 15.0 BDU13 CUB 15 30.6 33.8 2 24.8 23.0 20 23.0 14.9 20 140 19.0 BDU15 CUB 18 33.9 39.4 2 28.0 26.5 20 23.5 16.5 24 190 23.0 BDU18 CUB 20 33.5 38.9 2 28.0 26.5 20 29.5 18.0 24 195 23.0 BDU20 CUB 24 37.5 43.4 2 33.0 31.5 20 30.6 23.9 28 270 27.0 BDU24 CUB 30 40.0 52.8 2 40.0 38.5 20 33.5 24.0 36 410 35.0 BDU30 CUB 36 49.5 66.0 2 44.5 43.0 20 47.5 30.8 36 470 35.5 BDU36 *DO NOT USE FOR CONSTRUCTION CONSULT FACTORY FOR CERTIFIED PRINTS 4

CUB BELT DRIVE UPBLAST FANS PERFORMANCE 0 SP 0.25 SP 0.50 SP 0.75 SP 1 SP 1.25 SP 1.50 SP 1.75 SP 2 SP CFM RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP CUB 11 (MAX 1800 RPM) 1000 1038 4.7 0.07 1236 6.1 0.13 1397 7.6 0.20 1534 11.6 0.26 1658 12.3 0.33 1779 13.1 0.41 1200 1246 6.1 0.13 1415 9.0 0.20 1562 13.0 0.27 1690 14.0 0.35 1400 1454 11.6 0.20 1598 13.9 0.28 1735 15.3 0.37 1600 1661 15.0 0.30 1788 16.3 0.39 CUB 13 (MAX 1500 RPM) 1400 896 7.2 0.09 1017 9.1 0.16 1135 11.5 0.23 1252 12.1 0.31 1367 14.4 0.40 1480 15.7 0.50 1600 1024 9.9 0.14 1131 11.9 0.21 1235 13.9 0.29 1338 14.9 0.38 1439 15.8 0.48 1800 1152 13.1 0.20 1247 14.6 0.28 1340 15.4 0.37 1432 16.6 0.46 2000 1280 14.8 0.28 1366 17.1 0.36 1450 17.9 0.46 2200 1408 18.7 0.37 1486 19.4 0.46 CUB 15 (MAX 1400 RPM) 1600 700 7.1 0.09 779 7.8 0.14 911 9.4 0.23 1034 9.6 0.32 1151 12.6 0.43 1263 14.7 0.55 1371 15.3 0.69 1475 16.3 0.83 1573 17.6 0.99 1800 719 8.1 0.10 844 9.6 0.18 964 10.8 0.27 1077 10.8 0.37 1184 12.5 0.49 1288 14.8 0.61 1389 15.4 0.74 1486 16.5 0.89 2000 798 9.1 0.13 912 10.9 0.22 1021 10.2 0.32 1125 13.2 0.43 1225 13.6 0.55 1322 14.9 0.67 1415 15.6 0.81 1507 16.7 0.96 2200 878 10.2 0.18 981 12.2 0.27 1083 12.6 0.38 1180 14.0 0.50 1272 15.9 0.62 1362 15.8 0.75 1449 16.0 0.89 2400 958 11.6 0.23 1053 12.4 0.33 1146 14.3 0.45 1236 15.4 0.57 1324 17.5 0.70 1408 17.3 0.84 1490 17.1 0.98 2600 1038 12.0 0.29 1125 14.3 0.40 1212 15.1 0.52 1297 17.5 0.66 1379 18.6 0.79 1458 19.6 0.94 2800 1118 14.1 0.36 1198 15.5 0.48 1280 18.1 0.61 1359 18.7 0.75 1436 19.7 0.89 3000 1198 15.5 0.44 1273 19.1 0.57 1349 19.7 0.71 1424 20.0 0.85 3200 1277 19.4 0.54 1348 21.0 0.67 1419 21.0 0.82 1490 22.0 0.97 3400 1357 21.0 0.65 1423 22.0 0.79 1491 23.0 0.94 3600 1437 22.0 0.77 1499 24.0 0.91 CUB 18 (MAX 1250 RPM) 2000 524 4.2 0.09 638 6.0 0.18 733 7.7 0.28 822 9.0 0.39 2500 655 7.4 0.17 750 9.5 0.28 833 10.3 0.40 907 11.0 0.52 978 11.6 0.66 1047 12.1 0.80 1127 13.8 0.98 3000 786 11.2 0.29 866 12.2 0.42 940 12.8 0.56 1007 13.0 0.70 1069 12.5 0.85 1129 13.8 1.01 1188 15.0 1.17 1248 16.1 1.35 3500 916 13.9 0.46 986 14.8 0.61 1052 14.6 0.77 1113 15.1 0.94 1170 16.4 1.10 1224 17.6 1.27 4000 1047 15.6 0.69 1108 17.1 0.86 1168 17.7 1.04 1224 19.4 1.23 4500 1178 19.0 0.98 1232 21.0 1.18 5

CUB BELT DRIVE UPBLAST FANS PERFORMANCE 0 SP 0.25 SP.0.50 SP 0.75 SP 1 SP 1.25 SP 1.50 SP 1.75 SP 2 SP CFM RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP RPM SONE BHP CUB 20 (MAX 1100 RPM) 2700 490 4.8 0.12 584 6.2 0.23 684 8.0 0.38 774 9.5 0.53 862 11.3 0.70 3200 581 6.9 0.20 657 8.3 0.33 744 10.3 0.49 825 10.5 0.66 902 12.2 0.84 976 14.0 1.03 1050 15.4 1.24 3700 672 9.6 0.31 735 11.0 0.46 810 11.5 0.63 884 12.4 0.82 954 13.5 1.02 1020 15.0 1.23 1085 16.1 1.44 4200 763 12.5 0.45 817 12.5 0.61 881 13.5 0.80 947 14.7 1.01 1012 16.0 1.22 1073 16.6 1.45 4700 853 14.4 0.63 901 15.8 0.81 956 16.2 1.01 1015 17.2 1.23 1074 17.7 1.47 5200 944 17.3 0.85 986 19.0 1.05 1034 18.9 1.27 1087 19.1 1.50 5700 1035 21.0 1.12 1073 21.0 1.34 CUB 24 (MAX 1000 RPM) 3500 413 6.4 0.20 502 8.2 0.41 581 9.3 0.64 650 11.5 0.89 712 13.4 1.15 4500 530 9.6 0.43 602 11.3 0.69 668 12.9 0.97 729 13.8 1.26 785 14.9 1.57 838 15.8 1.90 887 16.8 2.24 933 18.1 2.59 5500 648 13.4 0.79 708 14.7 1.10 764 16.0 1.43 817 16.3 1.77 868 17.3 2.13 915 17.5 2.50 961 19.1 2.88 6500 766 17.0 1.30 818 18.0 1.67 866 18.1 2.05 912 19.2 2.44 957 19.4 2.85 1000 21.0 3.27 7500 884 19.8 2.00 930 22.0 2.42 972 22.0 2.85 8500 1002 25.0 2.91 CUB 30 (MAX 850 RPM) 6000 446 9.5 0.56 503 11.2 0.89 557 11.8 1.27 606 12.6 1.67 652 13.6 2.08 696 14.8 2.50 738 15.9 2.94 781 17.0 3.40 822 18.3 3.88 7000 520 13.2 0.89 569 13.7 1.26 617 13.8 1.69 662 15.2 2.15 703 15.9 2.61 743 16.1 3.09 782 17.1 3.57 819 19.1 4.06 855 19.8 4.57 8000 594 14.6 1.32 637 16.3 1.73 680 17.0 2.21 721 17.0 2.73 759 18.2 3.25 796 19.3 3.78 831 21.0 4.32 9000 669 17.4 1.88 707 18.9 2.33 745 20.0 2.86 782 19.0 3.42 818 22.0 4.00 852 23.0 4.59 10000 743 20.0 2.58 777 22.0 3.07 812 23.0 3.64 846 24.0 4.25 11000 817 26.0 3.44 848 26.0 3.97 CUB 36 (MAX 850 RPM) 8000 271 5.1 0.30 325 6.3 0.66 381 8.0 1.09 436 10.1 1.56 489 12.5 2.06 540 14.7 2.61 10000 338 8.1 0.58 381 9.3 1.02 425 10.4 1.52 470 11.7 2.06 515 13.6 2.63 559 15.5 3.23 601 17.1 3.87 643 18.7 4.53 683 20.0 5.24 12000 406 11.8 1.00 441 12.7 1.51 478 13.1 2.08 515 14.1 2.70 552 15.2 3.34 590 16.7 4.02 627 18.1 4.72 663 19.4 5.44 699 21.0 6.19 14000 473 14.9 1.59 504 15.9 2.18 535 17.2 2.82 566 17.5 3.50 598 18.5 4.22 630 18.2 4.97 662 19.3 5.74 694 20.0 6.54 726 23.0 7.35 16000 541 18.7 2.37 568 20.0 3.03 595 20.0 3.75 622 21.0 4.50 649 22.0 5.29 677 23.0 6.11 705 24.0 6.96 18000 609 23.0 3.37 632 24.0 4.12 656 23.0 4.90 680 25.0 5.73 704 26.0 6.59 729 27.0 7.48 20000 676 27.0 4.62 698 28.0 5.45 719 29.0 6.31 740 30.0 7.21 6

CUD & CUB UPBLAST FANS PRODUCT SPECIFICATION GUIDE 1.0 GENERAL A. Fans shall be model CUD Direct Drive or CUB Belt Drive Upblast Fans as manufactured by Continental Fan Manufacturing Inc., of Buffalo, NY, and of the size and capacity as indicated on the drawings and fan schedule. 2.0 FAN HOUSING DIRECT DRIVE MODEL CUD A. Fan housing shall be constructed of spun aluminum, roof or wall mount, and direct drive configuration. B. The discharge apron shall have a rolled bead for added strength. C. Curb base shall be constructed of welded galvanized steel. D. The motor mounting plate shall be constructed of heavy gauge steel and isolated from the fan structure with vibration isolators. E. Motor compartment shall be of a two piece construction, the top cap has quick release clips for easy access. 2.1 FAN HOUSING BELT DRIVE MODEL CUB A. Fan housing shall be constructed of spun aluminum, roof or wall mount (up to model CUB /2HP), and belt drive configuration. B. The discharge apron shall have a rolled bead for added strength. C. Curb base shall be constructed of welded galvanized steel. D. The motor mounting plate shall be constructed of heavy gauge steel and isolated from the fan structure with vibration isolators. E. Motor compartment shall be of a two piece construction, the top cap has quick release clips for easy access. 3.0 FAN IMPELLER A. Centrifugal impeller shall be backward inclined, non overloading. B. The blades and inlets shall be fabricated from aluminum. C. The blades shall be welded to the wheel inlet cone. 4.0 FAN MOTOR AND DRIVE A. Motor shall be ODP. B. Motor shall be of voltage, horsepower, RPM and enclosure as indicated on the fan schedule. C. The fan sheaves shall be cast iron, adjustable pitch, appropriately sized and aligned (CUB models only). D. The belts shall be static conducting, plus oil and heat resistant (CUB models only). E. The fan shaft shall be precision ground and polished (CUB models only). F. The fan shaft bearings shall be heavy duty, pre lubricated (CUB models only). 5.0 OPTIONAL FAN ACCESSORIES A. Where indicated, fan shall be provided with the following optional accessories: Gravity Dampers Motorized Dampers Roof curb (vented or non vented) Wall mount brackets Bird screen 6.0 FAN TESTING A. Centrifugal impeller shall be balanced and mounted in fan assembly. B. Fan assembly shall be run and tested prior to shipment. C. A test report shall be maintained on file for each individual fan. 7

CUD & CUB UPBLAST FANS Upblast_Fans 1307