Yakima County Water Resource System Guidelines for Rural Water Meter Installations Revised 1/3/2018

Similar documents
Section G: Brass Service Materials

ADDENDUM NO REFERENCE: FORM OF AGREEMENT, Schedule 2 List of Contract Drawings C C C C

Service Materials. Service Materials. With Three Locations to Serve You: Avoca, NY 8125 Kanona Rd. Avoca, NY (607)

PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

PIPE OUTSIDE DIAMETER GUIDE

APPROVED MATERIALS LIST SERVICE MATERIALS July 2017 **REVISED 12/6/17**

PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

ELIPS Pipe Materials Bid Summary August 29, :00am Bid Opening

SUB WATER DEPARTMENT STANDARD CONSTRUCTION SPECIFICATIONS TABLE OF CONTENTS SECTION WATER DISTRIBUTION VALVES

Harlingen Water Works System Approved Products List For Subdivisions. January 11, 2005

Mueller 300 Ball Valves Industry-leading 300psi low lead ball valves

CITY OF SAN DIEGO PUBLIC UTILITIES DEPARTMENT APPROVED MATERIALS LIST TABLE OF CONTENTS

PUBLIC UTILITY DISTRICT NO. 1 OF CHELAN COUNTY

Triton. Wet Barrel Ductile Iron. Fire Hydrants. Reliable Connections. operation / Maintenance manual. Inspection and Installation 2

SECTION II. (Sub-Section 300) Standard Water System Materials (Illustrations)

SAN ANTONIO WATER SYSTEM P. O. BOX 2449 SAN ANTONIO, TEXAS TABULATION OF BIDS

Depth of Bury Tables 9B-5. A. General. B. Rigid Pipe Assumptions. Design Manual Chapter 9 - Utilities 9B - Trench Design

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

SECTION VIII. (Sub-section 430) Wastewater Valves and Appurtenances. 1. General thru Gate Valves thru 430-3

Data Sheet Issue A

HDPE HIGH DENSITY POLYETHYLENE PRODUCTS

One City Plaza, Suite B P.O. BOX 1287 Cabot, Arkansas Phone Revised: April 2, 2019

PVC Stargrip series 4000 Mechanical Joint Wedge Action Restraint for Plastic Pressure Pipe

Ford Curb Stops and Meter Valves. Section G. 3/2012; Web Revision 02/2014

VALVES, FIRE HYDRANTS, AND APPURTENANCES

PRODUCT MANUAL TRENCH ADAPTER

Ford Brass Saddles Style 101B and 202B

MUNICIPAL WATER PRODUCTS OVERVIEW

GEO-ENTERPRISES, INC.

CENTENNIAL PARK EXPANSION

Approved Large Meter & Water Construction Materials

SERVICE SADDLES & Cambridge Brass Inc. 140 Orion Place, Cambridge, Ontario, N1R 5V1, Canada

PROJECT TITLE PROJECT NO: CONTRACT TITLE GRANT NO: UNIVERSITY OF CALIFORNIA, DAVIS CITY, CALIFORNIA

PUBLIC UTILITIES DEPARTMENT CITY OF SAN DIEGO APPROVED MATERIALS LIST FOR WATER STAN MEDINA DEPUTY DIRECTOR WATER OPERATIONS. u f! ASSISTANT DIRECTOR

Electric Utility Applications. The Right Enclosure The Right Location The Right Application

Ford Service Saddles and Tapping Sleeves

FIREFLO - MODEL F-06 INSPECTION, INSTALLATION & MAINTENANCE MANUAL. Item No.s/Description

PVC & CPVC Copper Tubing. Insulated Pipe Steel Conduit. Plastic Conduit SDR-35. Dual Containment Glass Pipe

GWE Street Expansion (Phase 2) LIST OF MATERIALS. Unit Qty Unit price Total. unit 3 $

DRIVEWAY/APPROACH PERMIT APPLICATION Applicant Type: Architect/Engineer Contractor Owner

Whapmagoostui First Nation. Main access ("B" street) Residential expansion - Phase 1 option D LIST OF MATERIALS. Revision Art.

September 2012 / M&H C502 / Model 129

Section G 01/2018 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Curb Stops and Meter Valves

FLORIDA RURAL WATER ASSOCIATION 2970 Wellington Circle Tallahassee, FL Telephone: ~ Fax:

PIPE REPAIR PRODUCTS REPAIR CLAMPS

Ford Service Saddles and Tapping Sleeves

SECTION VALVES PART 1 -GENERAL

JEFFERSON UTILITIES 270 INDUSTRIAL BLVD. KEARNEYSVILLE, WV (304) STANDARDS AND SPECIFICATIONS

Ford Coppersetters, Linesetters and Resetters All Ford Meter Setters are assembled using lead-free solder.

Section C. 10/2014 Web Revision 12/01/2017 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Meter Boxes

SHARKBITE INSTALLATION GUIDE

The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor.

APPENDIX A. List of Materials and Approved Manufacturers. Revised July 2018

M Installation Guide. PRECISION Manifold Series. Introduction. A. Assemble Manifold Components

Cam-Lock 111, 120 Joint Restraints Patent Pending

FORD ea S FORD ea FORD ea S FORD ea S FORD ea S FORD 27.

Innerlynx Type UL Fire Rated 3Hour Fire Stop ADVANCE PRODUCTS & SYSTEMS, INC. ISO-9001 CERTIFIED COMPANY - FM

BALL VALVES. Industry-Leading 300psi Low Lead Ball Valves

FINAL UTILITY REPORT Eastcreek Farm Thornton, CO

RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS SECTION VI RESIDENTIAL SUBDIVISION SERVICE REQUIREMENTS

AMENDED CULVERT POLICY WITH MAIL BOX POLICY

MATERIAL SPECIFICATIONS AND BID PROPOSAL SHEET

Section F 02/2018 THE FORD METER BOX COMPANY, INC. CERTIFIED TO ISO 9001: Ford Coppersetters, Linesetters and Resetters

Aqua Green Utility Inc.

Municipal Water Market Products

MODEL NO GALLON H.P. SKID SPRAYER ASSEMBLY / OPERATION INSTRUCTIONS / PARTS

SECTION 17 FIRE HYDRANT ASSEMBLIES General

Sentinel 250 Fire Hydrant

Curb Stops. Regular & Minneapolis Pattern 12/12

AMERICAN AVK COMPANY AVK SERIES 67 - HIGH PRESSURE, POST/FLUSHING HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

Underground Gas Polyethylene (PE) Piping

5 1 /4 PACER. It s AMERICAN What We Know. DARLING MARK 73 2 FIRE HYDRANT AMERICAN FLOW CONTROL WATEROUS FIRE HYDRANT

K81-D FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

Cable-Tight Wire Management System

8F. MUELLER / HUNT THERMAL-COIL METER BOX. 8F-PVC/bOXES/VAULTS

SHARKBITE INSTALLATION GUIDE

K81-DD FIRE HYDRANT GUARDIAN AWWA C502 NSF YEARS. For Generations CERTIFICATIONS ISO 9001 ISO BS OHSAS

No-Hub Couplings Drainage Drains Cleanout Plugs Cover Plates

Q= C. v P S Refer to Table 1 for part numbers and shipping weights. Accessories: Table 1: Valve Part Numbers and Specifications

AVK SAUDI VALVES MANUFACTURING COMPANY

traversing them. Speed dips may be installed in lieu of speed humps where the 85 th percentile speed on a street is at least 36 mph.

8F.1. MUELLER / McCULLOUGH THERMAL-COIL METER BOX 8F-PVC/BOXES/VAULTS

ORDINANCE NO

SAN ANTONIO WATER SYSTEM P. O. BOX 2449 SAN ANTONIO, TEXAS TABULATION OF BIDS

PVC WELL CASING & FITTINGS 20 FT. BELL-END /8 SDR21 REDUCING COUPLINGS STEEL WELL CASING & FITTINGS

The Ford Meter Box Company, Inc. The Ford Meter Box Company, Inc. Pell City, Alabama Plant. Wabash, Indiana Plant. The Ford Meter Box Company, Inc.

INSTALLATION, OPERATION & MAINTENANCE MANUAL

Manifold Isolation Valves

List of Materials and Approved Manufacturers

Application for Interconnection and Net Metering Revision: 1 Revised: November 7, 2017

NIAGARA FALLS WATER BOARD

Date of Issue: For: County Engineer. County Road No.: Maintenance Area: Section Forman Payment Required: (Options: Cash Cheque Credit Card)

INSTALLATION MANUAL APPLICATION: DRP psi) Dodge Replacement

PASCO COUNTY UTILITIES SERVICE CONNECTION APPLICATION Single Residential or Commercial

SECTION FIRE HYDRANTS WITH HYDRANT LOCKS

ZG 521 Padvault Three-Phase Transformer

This catalog contains the following geothermal accessory products and specification guides:

AMERICAN AVK COMPANY AVK SERIES 24 - HIGH PRESSURE, WET BARREL HYDRANT FIELD MAINTENANCE AND INSTRUCTION MANUAL TABLE OF CONTENTS

M-8100EP. Installation Guide ENGINEERED PLASTIC MANIFOLD SERIES. Introduction. A. Assemble Manifold Components

San Antonio Water System Standard Specifications for Construction ITEM NO. 834 FIRE HYDRANTS

Transcription:

Yakima County Water Resource System Guidelines for Rural Water Meter Installations Revised 1/3/2018 Steps for Installing Water Meters on Yakima County Water Resource System (YCWRS) Wells 1. Customer inquiries about YCWRS well permit and provides parcel number. 2. Public Services provides customer well depth criteria and meter data. 3. Customer constructs well to proper water bearing zone and installs pump. 4. Customer provides Public Services copy of Well Report. 5. Public Services reviews Well Report for proper well construction and provides copy to Health District. 6. Health District reviews Well Report for adequate water quantity and quality. 7. Customer applies for YCWRS well permit by completing Application for YCWRS Well Permit and paying Water Connection Permit Charge. Payment can be made at Yakima County Public Services, 128 North 2 nd Street, 4 th Floor Courthouse, Yakima WA 98901. 8. Customer installs meter box and meter setter. 9. Customer notifies Public Services that meter box and meter setter are ready for meter and transmitter installation. 10. Public Services installs meter and transmitter and checks operation with Customer. 11. Public Services, upon final approval, commences quarterly billings. First quarterly bill will include cost of meter and transmitter installation. YCWRS Guidelines Page 1 of 4 Printed: 1/3/18

Installation Guidelines 1. Meter must be installed on the waterline from the well prior to any lateral connections. 2. Meter must be accessible and protected from freezing. Example meter installation is shown in Yakima County Standard Plan RW-1. 3. Transmitter must be installed away from large metal objects. 4. Meter and transmitter must be installed in accordance with the manufacturer s instructions. 5. Materials described below are provided as an example for installing meters on YCWRS wells. Equivalent materials from other manufacturers are available. Meter and Transmitter Meter and transmitter will be provided and installed by Public Services to ensure compatibility with County s meter reading system. All other materials will be provided and installed by Customer. Meters will be Badger Meter E-Series Ultrasonic Meter. Available meter sizes include ¾ and 1. The typical transmitter, also referred to as the endpoint, will be an Orion Cellular LTE Endpoint. If cellular service is not available, an Orion Migratable (ME) Endpoint will be installed. Fees for the cellular service will be paid by Public Services. Meter flow range must be adequate for the capacity of the pump installed. Meter flow ranges and estimated pressure losses are noted below. Customer is advised to notify their pump installer of the estimated pressures losses to help in sizing the pump. Meter Meter Length Meter Flow Range Pressure Loss ¾ 7.5 0.1 32 gpm 13 psi at 15 gpm, 30 psi at 25 gpm, 45 psi at 32 gpm 1 10.75 0.4 55 gpm 6 psi at 15 gpm, 15 psi at 25 gpm, 23 psi at 35 gpm 1. Pressure losses include losses through meter and meter setter. 2. Meter setters with full port ball valves are available to help reduce pressure losses. Meter Setter A meter setter is used to provide easier access to the meter while maintaining additional space below the meter to minimizing the risk of freezing. Several manufacturers are available including the Ford Meter Box Company, Mueller, A.Y. McDonald, and Cambridge. Meter setters must be a minimum of 18 in height with an angle ball valve on the inlet and angle check valve on the outlet, or, to reduce pressure losses through the meter setter, the angle ball valve and angle check valve can be replaced with full port ball valves. Insert stiffeners must be used on each end to prevent leaks. Model numbers will vary depending on the meter size, pipe size and type of pipe used. YCWRS Guidelines Page 2 of 4 Printed: 1/3/18

Meter Pipe Manufacturer Meter Setter Compression Coupling Insert Stiffener ¾ 1 Ford Meter Box VBH72-18W-11-33-NL C84-34-Q-NL Insert-52 1 1 ¼ Ford Meter Box VBH74-18W-11-44-NL C84-45-Q-NL Insert-72-Q 1 1 ½ Ford Meter Box VBH74-18W-11-44-NL C84-46-Q-NL Insert-54-Q 1. Part numbers listed are provided as an example. There are many combinations of meter setters and compression couplings available from several manufactures. 2. Compression couplings listed are based on copper tube size (CTS) PEX and HDPE pipe. Compression couplings for use on iron pipe size (IPS) pipe and PVC, will vary from those listed. 3. Larger pipe sizes may be used by installing a brass nipple and bell reducer. 4. Smaller pipe line sizes will result in greater pressure losses and a decrease in pumping capacity. 5. Full port ball valves may be installed on the meter setter inlet and outlet in lieu of the reduced port ball valve and check valve to reduce pressure losses. Pipe Either High Density Polyethylene (HDPE) meeting the requirements of AWWA C901 or PEX pipe meeting the requirements of AWWA C904 with a minimum pressure class of 160 psi is recommended. Either of these pipe materials are available in copper tube size dimensions. HDPE pipe is also available in Iron Pipe (IPS) dimensions, which results in a slightly larger pipe diameter. Meter Box Meter boxes shall have a minimum cover size of 13 x23. Covers shall be suitable for automated meter reading systems and should include a recessed opening for the endpoint. In lieu of a recessed opening, a 1-7/8 hole can be drilled through most plastic meter box covers for mounting the endpoint. Plastic and polymer concrete meter box covers are generally suitable for automated meter reading systems. Ductile iron, metal and concrete meter box covers will reduce the signal strength from the endpoint making them unsuitable for automated meter reading systems. Meter Boxes shall be located in non-traffic areas whenever possible. If meter box is located in an area where vehicular loads are possible, then meter box shall be rated for at least 20,000 lbs. The Customer is cautioned, that although meter boxes rated for 20,000 lbs will generally hold up when placed in areas where occasional vehicular loads are possible, they are not traffic rated. Meter boxes with a 20,000 lb load rating are designed to be placed alongside roadways in areas protected by curbs where incidental vehicle loads may occur. Examples of meter boxes include: YCWRS Guidelines Page 3 of 4 Printed: 1/3/18

Meter 20,000 lb rating Manufacturer Meter Box Model No. Meter Box Lid ¾ or 1 ¾ or 1 No Yes Carson Carson 1324 BCF 1324 BCF HD HDPE Flush Solid Polymer Flush Solid 1. Two 18 tall meter boxes may be used in lieu of three 12 tall meter boxes. Insulation Board Insulation board shall be suitable for buried installations and shall be expanded polystyrene rigid insulation or equivalent. Insulation board is available at most hardware stores. Example Material Suppliers HD Fowler Waterworks 1100 River Road Yakima, WA 98902 (509)-248-8400 Valley Supply Co. 404 N Railroad Avenue Ellensburg, WA 98926 509-933-1800 Ferguson 1130 W Washington Pasco, WA 99301 (509) 544-2245 YCWRS Guidelines Page 4 of 4 Printed: 1/3/18