Instruction Manual. Models FD30 / PB30. Fittings for the DO30G. IM 12J06K04-E-E 6th edition

Similar documents
General Specifications

General Specifications

General Specifications

Model PH87 Retraction Sensor Assembly

Instruction Manual. Model SC4A 19mm Conductivity Sensors. IM 12D7J4-E-E 6th edition YOKOGAWA

General Specifications

General Specifications

Manifolds for DPHarp EJA and EJX Pressure and Differential Pressure Transmitters. Pressure psi (bar) (860) (552) (413) 4.

General Specifications

User Manual. Model PR20 Retractable fitting for combined ph/redox electrodes. IM 12B6K3-E-E 9th Edition

Instruction Manual YOKOGAWA. ph/orp. Model FD20 Immersion Fittings. IM 12B06K02-01E-E 9th edition. IM12B06K02-01E-E_ed09.indd 1 07/03/16 09:51

General Specifications

Instruction Manual YOKOGAWA. Model FD20 Immersion Fittings. ph/orp. IM 12B6K2-01E-E 7th edition

General Specifications

General Specifications

General Specifications

General Specifications

Variable V Area Flowmeter Rotameter The Original

General Specifications

General Specifications

Digital Vortex Flowmeter. digitalyewflo. Digital Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

User Manual. Model PD20, PF20 and PS20 Compact ph Probe YOKOGAWA. IM 12B6K4-01E-E 8th Edition

Instrumentation Manifolds Traditional C13WT series. For DPharp EJX & EJA-E Differential Pressure and Pressure Transmitters

Flow-Through Fitting ARF 215

General Specifications

Vortex Flowmeter. digitalyewflo. Vortex Flowmeter. Series. Bulletin 01F06A02-00E.

Personal ph, ph/orp, Conductivity Meters

Model PH8HG Drop-in Guide Pipe

Bolt Type Test Plug - Technical Specifications

General Specifications

Parts List 8 AAT-60 and AAT-90 Auto-Adjust II Turbo-Meters

Lead-free glass Nickel plated brass 62 ma 1.25 A Over 1.25 A 3 A Epoxy resin 62 ma less than 1 A. Tube: End-cap: Solder: Adhesive: Marking: 1 A 3 A

Process to Instrument Valves: C13SF Monoflanges For DPharp EJX & EJA-E Pressure Transmitters

Productinformatie BAFA.NL BAFA.NL A.U.K. MÜLLER GMBH & CO. KG

Tube: End-cap: Core: Solder: Lead-free glass Nickel plated brass Ceramic Sn-1.5Cu. Pb87.5-Sn10-Ag2.5* ma less than 1 A.

Combination ph/redox (ORP) Sensors

SENSOFIT RET 5000 Technical Datasheet

INSERTION Adaptor for analysis

introduction FE Series Butterfly Valves Product Data Sheet

General Specifications

General Specifications

Micro Motion T-Series Straight-Tube Mass Flow and Density Meters. Product Data Sheet PS July 2001

Rosemount 402 and 402VP

Lead-free glass Nickel plated brass Ceramic 100 ma 15 A. Tube: End-cap: Core: Solder: 200 A. Marking: 100 ma 8 A Over 8 A 20 A. Rated breaking current

UNIVERSAL SOLAR SYSTEM (USS) USER MANUAL. For Millennium Low Power Gas Detectors or other continuous loads less than 0.

Combination ph/redox (ORP) Sensors

introduction FK Series Butterfly Valves Product Data Sheet

Cleanfit W CPA450. Technical Information. Retractable assembly for 12 mm sensors for DO/pH/ORP measurement

General Specifications

Cleanfit H CPA475. Technical Information. Retractable assembly for ph, ORP measurement under sterile conditions

Navigator ADS551 Low level dissolved oxygen Replacement / Upgrade procedures wet section spares

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Control Components Pty Ltd. Drawing Number. Indicator Model Overview A 66.01A Side flanged connection

General Specifications

General Specifications

WalkLAB Digital Dissolved Oxygen meter HD9030

Operation Manual MODEL EC331. Microcomputer Based Conductivity /Resistivity & Temperature Pocket Meter EC331

OFFICINE OROBICHE S.p.A. 1/7 INSTRUCTION MANUAL FOR FLOW SWITCHES PL SERIES

Technische Dokumentation Technical Documentation

General Specifications

STARTER 2000 Bench ph Meter Instruction Manual

MCF3 25CT Inrush-withstand

General Specifications

General Specifications

Modular Outdoor Fountain System

Flow Fittings. for Electrochemical Sensors. B Operating Manual /

Technical Information Cleanfit CPA451

General Specifications

GLASS LINING TECHNOLOGIES. Bottom Outlet Valves

Visual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Material Pipe Operating Operating Page

Instruction Manual PN 51-BB11/rev.A April Model BB11 FLOATING BALL SYSTEM

Auto-Adjust II Turbo-Meters

MidFlow _ 135. Sliding Vane Meters DN (1-2 ) Model PT / Fuel Oil Flowmeters135. Product Bulletin

Type 567. Wafer Style Butterfly Valve

Nalco Corrosion Test Rack 1

MCF3 DC86V11CT Inrush-withstand

OD 8382 OPTICAL DISSOLVED OXYGEN AUTOCLEAN

INSTALLATION and OPERATION INSTRUCTIONS

Service Bulletin #117 SJ7127 RT, SJ7135 RT, SJ8841 RT, SJ9250 RT Brake Manifold Assembly Replacement

Installation Instructions F-440N. Model No. F F F F F F F /16 157mm. Inline.

General Specifications

General Specifications

Lead-free glass Nickel plated brass Ceramic Tin plated copper Sn-1.5Cu Pb87.5-Sn10.0-Ag2.5* SOC NSD9 D32V [rated current]

Model 8317 Combination Shower Eye/Face Wash

OPERATING INSTRUCTIONS

HYDRAULIC CONTROL VALVES

NELES BO SERIES BUTTERFLY VALVE FOR RECOVERY OF OXYGEN IN VACUUM PRESSURE SWING ADSORPTION (VPSA) PLANTS

Scotch Yoke Actuators 2016 EDITION. Heavy Duty Pneumatic Actuators SHD and CHD series. The Best Way To Automate Your Process.

Benchmark HD Series Heavy Duty Bench Scale. Installation Manual

Pressure relief valve

Process Inline Filter PLF1

IP54 Gasket Kit VGA-IP54K-IC VGA-IP54K-IC78. Installation Guide

A Member of the. Integrated Metering Technologies

A6 type. General universal type. Submerged type Connector box type. Installation method Titanium PPS FKM

MODEL HD-BTC. Installation, Operation & Repair Parts Information REV041416

Inductive conductivity meter

Push Down Wheeled Walker

Pneumatic Controller for Temperature. Type Pneumatic Controller for Temperature. Type Mounting and Operating Instructions EB 7065 EN

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

General Specifications

Transcription:

Instruction Manual Models FD30 / PB30 Fittings for the DO30G 6th edition

2 Table of contents 1. Introduction...3 2. Unpacking and checking...3 3. Warranty and service...3 4. Genral specifications...4 4-1. Model FD30 Immersion Fitting...4 4.2 Model PB30 Floating Ball Fitting...5 5 Installation...6 5.1 General...6 5.2 Assembling and mounting of the immersion fitting...6 5.2.1 Checklist...6 5.2.2 Preparing the immersion fitting...7 5.2.3 Mounting the sensor in the immersion fitting...7 5.2.4 Mounting the sensor cleaner (/JC option)...7 5.3 Installing the floating ball fitting...8 5.3.1 Checklist...8 5.3.2 Installation...8 5.3.3 Assembling the floating ball fitting (ref to Figure 4)...8 6 Spare parts...9 6.1 Model FD30V27 Immersion Fitting...9 6.2 Sensor Cleaner (/JC option)...9 6.3 Model PB30 Floating Ball Fitting...9 7 Dimensions...10

1. Introduction To support the Yokogawa Model DO30G sensor for measuring dissolved Oxygen, two types of sensor holders are offered; an immersion fitting (Model FD30V27) and a floating ball fitting (Model PB30). Both fittings are intended for mounting the DO30G in a tank, measuring either on the surface or sub-surface of the process liquid. The type of sensor holder, as well as the point of installation, should be selected to allow measurement in a location where the measurement truly represents the entire solution. Avoid areas where the measurement value varies significantly e.g. stagnant corners. Select a place where the sensor is always immersed in the process liquid. Properties of the sensor holders are: Model FD30V70 Sub-surface measurement of dissolved Oxygen Available in different pipe-lengths i.e. 40mm outer diameter Available with a metric to inch adapter i.e. 40 to 42mm outer diameter (standard 1¼ pipe) Standard equipped with membrane check-facility Available in flanged and non-flanged version Optional Jet Cleaning (/JC Option) for avoiding fouling of the membrane Optional Mounting Set (/MS1 Option) for convenient mounting) Model PB30 Designed for minimal user maintenance Good flow of sample at the membrane due to wave action and constant ball movement Constant measurement depth Standard equipped with membrane check-facility Shipped including a winch mounting mechanism 3 2. Unpacking and checking Upon receipt of the goods, carefully inspect the shipping package for any evidence of damage. If the carton is damaged, notify the shipping agent and the sales organizationv immediately. If the shipping package is not damaged, remove the products and parts. Confirm that all items shown on the packing list are available and that the package does not contain any parts or accessories hidden between the shock absorbing fillers. Notify the sales organization if items are missing. 3. Warranty and service Products and parts are warranted to be free from defects in workmanship and material under normal use and service for a period of typically twelve months from the date of shipment by manufacturer. The sales organization has the possibility to deviate from this typical warranty period and the actual terms and conditions as specified in the sales order must be consulted. Damage caused by wear and tear, inadequate maintenance, corrosion and attack by chemical processes are excluded from this warranty coverage.

4 All defective goods need to be sent to the service of the sales organization for repair or replacement and the returned material should be accompanied by a letter of transmittal, which should include the following information: Part number, Model code and Serial number Date and number of sales order Length of time of service and type of service Description of the faulty operation of the device and the circumstances of the failure Pressure, temperature, process composition and all other process conditions or environmental circumstances which are related to the installation and possibly failure of the device Statement as to whether warranty or non-warranty service is requested Complete shipping and billing instructions for return of material and name, phone number of contact person that can be approached for further information. The returned goods that have been in contact with process fluids must be detoxified and disinfected prior to shipment for the health and safety of our employees. Material Safety Data sheets must be included for all components of the processes in which the sensors/ fittings have been used. The shipping address where to the goods have to be returned is specified on the original sales order or on the back page of this manual. 4. General specifications 4.1 Model FD30 Immersion Fitting Wetted materials - Body & flange : Polyvinylchloride (PVC) - O-rings : Silicone rubber - Blanking plug : Ryton R4 (remove before use!) - Conductive bushing : Brass Temperature - Minimum : -10 C - Maximum : +50 C Pressure : 2 bar max. Immersion length : 0.5 to 2.0 m (10 cm steps) When ordered as a subassembly (pipe length 00), a tube with PVC cement will be delivered with the holder Weight - Without flange : 1.35 kg + 0.2 kg per 0.5 meter - With flange : 0.5 kg extra Options - Sensor/cable : See DO30G - Flexible conduit : PVC and Nylon Option /PH5 : 5 meter protection hose Option /PH10 : 10 meter protection hose - Jet cleaner (Option /JC) : Materials: PVC, Nylon, PVDF and PTFE Temperature: as FD30 Pressure: as FD30 Immersion length: nominal + 4 cm - Mounting set (Option /MS1) : Material; Galvanized steel

5 Model and Suffix code Immersion Fitting Model Suffix Option Description FD30V27 Immersion Fitting PVC Immersion -00 Pipe supplied by user length -xx Between 0.5 and 2.0 (in steps of 0.1m) Example: 06 = 0.6 m Mounting -FN No flange flange -F1 DIN DN50 PN10 -F2 ANSI 2 150 lbs *A Style A Protection hose /PH5 5 meter /PH10 10 mtr Jet Cleaner /JC * Mounting set /MS1 * * Not available with flanged versions. 4.2 Model PB30 Floating Ball Fitting Wetted materials : High impact polystyrene, PVC & Brass Temperature : 0-40 C Mounting bracket Sensor/cable : Galvanized steel, for rail, or surface mounting : See DO30G Shipping details - Weight : 12.5 kg Approx. - Package size : 490 x 320 x 340 mm - Main support arm : 2.5 m Model and Suffix Codes Floating Ball Model Suffix Code Description PB30 Floating Ball Fitting Pipe length -00 Pipe supplied by user -25 2.5 meter Sensor type -SNN No sensor Cable length -00 No cable

6 5. Installation 5.1 General It is important to have the point of measurement in a location that is representing the process composition. Check whether the specifications of the sensor/fitting/holder fulfill the maximum occurring process conditions. Install the fitting in a place where it can be maintained and calibrated safely and easily. After installation of the sensor it may need several hours to stabilize readings. Stabilization can take up to 24 hours. ATTENTION Do not insert the fitting/holder into the process without the sensor mounted, to avoid the cable leads becoming wet. 5.2 Assembling and mounting of the immersion fitting 5.2.1 Checklist The FD30V27-xx-FN fittings will be delivered completely assembled. Flanges (suffix code -F1 or -F2) and options will be delivered separately. The FD30V27-00 version will be delivered in parts excluding the pipe (see Figure 1). The holder piece (3) and the top piece (1a/b) have an internal diameter suitable for both 40 mm and 11/4" customer's pipe. The jet cleaning (option /JC) will be delivered as indicated in Figure 2. 2 1a 11 9 10 3 1b 6 7 5 8 4 Top piece (1a/b) Pigtail (2) Holder piece (3) Screw piece (4) Conductive bu shing (5) O -ring (6) Stopper (7) O -ring (8) Tube PVC adhesive (9) Instruction manual (10) Flange (if specified) (11) Figure 1

7 5.2.2 Preparing the immersion fitting Prepare the immersion fitting by unscrewing the screw piece (4) from the bottom of the fitting. Remove the stopper (7), which can be discarded, and the conductive bushing (5). The screw piece will be used to fix the DO sensor in the fitting. When a flexible conduit (protecting hose) will be used, the pigtail part (2) can also be discarded. When an immersion fitting with cleaner is used the cleaning cage will be used to fix the DO-sensor. In that case the screw piece can also be discarded. In case of a FD30V27-00 version the top piece and the holder piece should be mounted on the customers pipe using the supplied adhesive. Ensure that the sealing will be watertight. Figure 2 5.2.3 Mounting the sensor in the immersion fitting Pull the sensor cable through the O-ring into the fitting and through the pigtail (see Figure 3). In case a flexible conduit will be used please remove the pigtail and follow the instructions delivered with the protecting hose option. Push the O-ring over the cable assembly until it lies on the knurled ring. Plug the cable assembly into the sensor body, if this was not performed before. Secure the cable assembly with the knurled ring. Place the sensor in the fitting and put the bushing (essential for sensor diagnostics) around the sensor as far as it will go. Then screw the screw piece, or the cleaning cage, in again. This will fix the sensor in place by compressing the O-ring. Tighten the pigtail at the top of the fitting.

8 5.2.4 Mounting the sensor cleaner (/JC option) After fixing the sensor with the cleaning cage it is possible to screw the cleaner tubing on the cage using the swage lock coupling material provided with the cleaner. It is recommended to fix the tubing to the holder using tie wraps. Keep some flexible length of tubing for ease of maintenance. The cleaner can be used for both water and air. It is recommended to use a solenoid valve of the normally closed type with matching connections. The solenoid valve can be switched with the wash contact of the EXA DO-converter. 5.3 Installing the floating ball fitting 5.3.1 Checklist The floating ball fitting with sensor for Dissolved Oxygen will be delivered in parts and has to be assembled before it can be used. Check if all standard parts are delivered, see Figure 4. Please note that items (4) and (2 + 6) are optional and, if not specified with the order, these parts will not be delivered. The position ring (9) will only be received when PB30-00. is ordered. This part is only needed when 11/2" pipe will be used in stead of 50 mm. Figure 3 5.3.2 Installation Mount the floating ball not exactly vertical, but under a slight angle, so that air bubbles do not 'stick' or adhere to the membrane. 5.3.3 Assembling the floating ball fitting (ref to Figure 4) Attach the mounting bracket (1) to wall or pipe; clamps are already fixed to the bracket. Install the main support arm (2) (in case of PB30-00... the customers pipe), in the mounting bracket (1) and adjust its length to the desired length. Use the supplied adhesive (7) to stick the lower support to the main support arm (2). When a 11/2" pipe is used, the position ring (10) must be mounted in between them to compensate for the difference. Attach (not for PB30-00...) the 90 elbow (6) to the upper end of the main support arm and cement it with adhesive (7). Guide the cable assembly (4) through the main support arm. Position the complete sensor (4) in the lower support. Place the lower support (3) into the ball (8) by screwing the fixing nut hand-tight. Connect the leads of the cable to the EXA DO converter.

9 6 7 2 9 3 10 1 4 7 8 6. Spare parts Figure 4 6.1 Model FD30V27 Immersion Fitting Item Description Spare part no 6 5 x O-ring K1500FX 8 5 x O-ring K1500FY 6.2 Sensor Cleaner (/JC option) Item Description Spare part no 1 5 x O-ring 37.7 X 2.6 for mounting sensor in fitting K1500FY 2 Holder 3+4 Nozzle parts K1500AZ 7 10m tubing (1/4 ) for jet cleaner K1530UL 3,4,6 Spray nozzle for jet cleaner K1530UK 6.3 Model PB30 Floating Ball Fitting Item Description Spare part no 1 Mounting bracket K1530DQ 2 Main support arm 3 Lower support arm with O-ring K1530QA 4 DO30G sensor See DO30G 6 Elbow 90º 7 Tube PVC adhesive 8 Floating ball assembly with O-ring K1530SA 9 Position ring 10 O-ring 25.3 x 3.2 Viton 70º shore K1500AV (5x)

10 Dimensions Figure 5: FD30 Figure 6: FD30 with flange 18 (0.70) 78 (3.07) 125 (4.92) 168 (6.60) 18 (0.70) Ø 100 (3.94) Ø 40 (1.57) L Ø 40 (1.57) L Ø 50 (1.97) 90 (3.54) Ø 50 (1.97) 70 (2.80) 70 (2.80) 90 (3.54)

11 Figure 7: Option /MS1 Fill piece Guide pipe Ø 48,6 x 600 (Ø1.9 x 24") Min: 110 (4.35") Max: 515 (20") 2-inch Stanchion (Vertical) Figure 8: PB30 rail mounting 2570 ± 50 (100 ± 2) pipe/rail mounting DN 50 (2.00) Ø 50 (1.97) 344 (13.54) 230 (9.06)

Figure 9: wall mounting 111 (4.37) 70 (2.75) Ø 9 (.35) 121 (4.76) 164 (6.45) YOKOGAWA HEADQUARTERS 9-32, Nakacho 2-chome, Musashinoshi Tokyo 180 Japan Tel. (81)-422-52-5535 Fax (81)-422-55-1202 E-mail: webinfo@mls.yokogawa.co.jp www.yokogawa.com YOKOGAWA EUROPE B.V. Euroweg 2 3825 HD AMERSFOORT The Netherlands Tel. +31-88-4641 000 Fax +31-33-4641 111 E-mail: info@nl.yokogawa.com www.yokogawa.com/eu Subject to change without notice Copyright YOKOGAWA CORPORATION OF AMERICA 2 Dart Road Newnan GA 30265 United States Tel. (1)-770-253-7000 Fax (1)-770-251-2088 E-mail: info@yca.com www.yca.com YOKOGAWA ELECTRIC ASIA Pte. Ltd. 5 Bedok South Road Singapore 469270 Singapore Tel. (65)-241-9933 Fax (65)-241-2606 E-mail: webinfo@yas.com.sg www.yokogawa.com.sg Yokogawa has an extensive sales and distribution network. Please refer to the European website (www.yokogawa.com/eu) to contact your nearest representative. YOKOGAWA 06-817 (A) I Printed in The Netherlands