INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER

Similar documents
MODEL 233P/111P/233P-1.5

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

201A-9 INSTALLATION INSTRUCTIONS. Revision A1 Rapid City, SD, USA, 01/2010

Installation and Operating Instructions

Installation and Operating Instructions

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Owners Manual. Features

Owner s Manual. Features

Owners Manual. Features

Electronic Products ELECTRONIC MAINTENANCE

ADVANCED PID TROUBLESHOOTING

MODEL 422 Submersible Pump Controller

4" Motors and Controls

The Da-Lite Difference.

Motor Application and Installation Data

The Da-Lite Difference.

KD LV Motor Protection Relay

Boston Gear Ratiotrol DC Motor Speed Control

CONSTANT PRESSURE CONTROLLERS

The Power of Reliability INSTRUCTION MANUAL

PHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC

Installation, Operation and Maintenance Manual

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

Installation, Operation and Maintenance Manual

Motor Application and Installation Data

Application Engineering

The Da-Lite Difference.

Application Engineering

The Da-Lite Difference.

Instruction Book for. ContouR ElECtRol

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

4" SUBMERSIBLE PUMP 4" SUBMERSIBLE PUMP. "GS" series. "ST" series. "SL" series. ST Series (stainless steel) SL Series (thermoplastic)

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Installation, Operation and Maintenance Manual

CONSTANT PRESSURE CONTROLLERS

AeroVironment Universal Solar Pump Controllers

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Single & Three-Phase Soft Starters

Pump Station. Models ADW2W31, ADW2W51, ADW2W71, ADW2W73

The POWER. In PRESENTATION PRODUCTS. Instruction Book for COSMOPOLITAN ELECTROL For Sizes Up To 9'x12' DA-LITE SCREEN COMPANY, INC.

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

PHOENIX Amp Brushless Sensorless Speed Control. 1.0 Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation

Models DP10 & DP20 Series Low Voltage Disconnects User s Manual Rev. 1.1 October 31, 2007

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

INSTALLATION INSTRUCTIONS

Installation, Operation and Maintenance Manual

Installation Instructions

Product Overview. Product Identification. Amps One CT Two CTs Three CTs

INSTRUCTION MANUAL CAUTION

Activator 282 Aircraft Battery Maintenance Charger Operator Manual

Auto-Trol Limited 1660 SW 196th Avenue * Aloha, OR 97003

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

The Da-Lite Difference.

OD10 10A Outdoor Solar Charge Controller

Pump Installation and Service Manual HRS Hydromatic Retractable System

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Motor. Document # Vari-Green Motor and Controls. Table of Contents. Features, Operation, Wiring and Troubleshooting

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Centrifuge Operator / Service Manual

PHOENIX HV Features of the Phoenix HV-45 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

Helios. 24 Light 240 Volt Controller. PRODUCT # Instruction Manual.

WF-5110R True Sine Wave Inverter

INSTALLATION INSTRUCTIONS

Flight Systems. Replacement for KASSEC DESCRIPTION

Definitions. Scope. Customer Generation Interconnection Requirements

DFC-1 STANDARD TEMPERATURE CONTROL. DFC-2 TEMPERATURE CONTROL w/ INTEGRAL 40 F-90 F SELECTOR DFTD TEMPERATURE SELECTION DIAL DFTS TEMPERATURE SENSOR

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

APOLLO Gate Operators, Inc.

150 B180 N B D A 8L. Enclosure Type. Input Line Voltage Open Type V AC, 3-phase, 50 and 60 Hz V AC, 3-phase, 50 and 60 Hz

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Commander Pro Variable Speed Controller System Instructions

Sola/Hevi-Duty S3K Series Mini-Tower UPS

User s Manual. Automatic Switch-Mode Battery Charger

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

INSTALLATION INSTRUCTIONS

MODEL CMS INSTALLATION INSTRUCTIONS A. INTRODUCTION 1. USAGE 2 2. HOW IT OPERATES 2 B. SPECIFICATIONS 1. ELECTRICAL 3 2.

PHOENIX Features of the Phoenix-25 : 2.3 Connecting the Motor. 2.4 Reversing Rotation. 2.5 Connecting the Receiver

Power Electronics. MINISTOP Motor Brake Relay BA 9034N

1993 Lionel Trains, Inc., Chesterfield, MI LIONEL RS-I TRANSFORMER

Boston Gear Ratiotrol

Infinity & Infinity HD

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

DC-PMM/24V Power Management Modul für Positionier-Motor POSMO A Power Management Module for Positioning Motor POSMO A

PD-Series Ground Fault Circuit Protection

SPC-PANEL Simplex, Single Phase Pump Control Panel

Boston Gear Ratiotrol

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

5. OVERCURRENT RELEASE (OCR)

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

Boston Gear Ratiotrol DC Motor Speed Control

ME AGS Auto Gen Start System for Coach Generators. Operator s Manual.

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description

HP Volts Stages Discharge Head Length Brand S10P4HS /2 6 S10P4HS / " Sta-Rite S10P4HS Stainless Steel

Three Function Remote Control System with Alarm (Model RCA-3)

EAGLETRON II REMOTE CONTROL OPERATOR and MAINTENANCE. Remote Control Procedure

SERVICE MANUAL (DOMESTIC & INTERNATIONAL)

Transcription:

INSTALLATION INSTRUCTIONS FOR SYMCOM MODEL 231-P-INSIDER The PumpSaver Plus Model 231-P-INSIDER fits inside 1/3 1hp, 230V Franklin, Pentek, or CentriPro control boxes. PumpSavers are designed to protect single-phase pumps from dry-well, dead-head, rapid-cycling, jammed impeller, and over/undervoltage conditions. Typical applications include residential waterwells, commercial waterwells, irrigation wells, and golf course and other sprinkler systems. CONNECTIONS Refer to specific connection instructions depending on the particular control box being used: Franklin control box page 3 Pentek control box page 5 CentriPro control box page 7 CALIBRATION / SETTINGS 1. Turn RESTART DELAY/CALIBRATION to the CAL position and close the box cover. 2. Apply power to the system. The pump should run for approximately 10 seconds and then shut off this indicates the Model 231-P INSIDER has calibrated. 3. Remove power from the system. Open the control box and set the appropriate dry-well recovery time with the RESTART DELAY / CALIBRATION knob. 4. Shut the control box and re-apply power to the system. OPERATION The Model 231-P-INSIDER monitors pump load in amps and kilowatts. When the current (amps) exceeds approximately 125% of calibrated current, or power (kw) drops below the adjustable underload trip point, the 231-P-INSIDER after the trip delay will turn off the pump. The 231-P- INSIDER will automatically restart the pump after the selected restart delay time. The calibration is stored in permanent memory. The PumpSaver Plus does not need to be recalibrated if power is lost. SENSITIVITY The Model 231-P-INSIDER has an adjustment knob to set the underload trip sensitivity. Setting SENSITIVITY to the middle position (straight up) is equivalent to SymCom s standard underload trip level. Adjust the SENSITIVITY knob to increase/decrease underload sensitivity up to approximately ±10% of the standard trip. It may be necessary to increase the sensitivity if the PumpSaver Plus does not trip on dry-run or dead-head or it is known that the water level in the well is very low relative to the pumps capabilities. WARNING: Decreasing the SENSITIVITY may compromise the PumpSaver s ability to detect dry-run and/or dead-head conditions. 2880 North Plaza Drive, Rapid City, SD 57702 (800) 843-8848 (605) 348-5580 www.symcom.com

RUN HOURS The Model 231-P-INSIDER records pump run hours. Run hours can be displayed by a PumpSaver Plus Informer (see USING AN INFORMER). Run hours can be reset on the 231-P- INSIDER. please read the instruction fully before performing the procedure. NOTE: Turn the SENSITIVITY knob completely to the left (counter-clockwise) or completely to the right (clockwise) when directed. WARNING: ENSURE POWER IS APPLIED TO THE 231-P-INSIDER IN A SAFE MANNER WHEN PERFORMING THE FOLLOWING PROCEDURE. To Reset Run Hours: 1. Remove power to the 231-P-INSIDER. 2. Set the RESTART DELAY/CALIBRATION knob to RESET and the SENSITIVITY knob to the middle (12:00) position. 3. Apply power to the 231-P-INSIDER the CAL. LIGHT will turn on. 4. Turn the SENSITIVITY knob to the right the CAL. LIGHT will turn off and the RUN LIGHT will turn on. 5. Turn the SENSITIVITY knob to the left both lights will turn on. 6. Turn the SENSITIVITY knob to the right. 7. After 10 seconds, the CAL. and RUN LIGHTS will blink twice indicating the run hours have successfully been reset. RAPID CYCLING Rapid cycling is defined as more than 4 restarts in a 60-second period. Upon detecting rapidcycling, the 231-P-INSIDER will lock-out until power is removed and re-applied. Rapid-cycle protection can be disabled. Please read the instructions fully before performing the procedure. NOTE: Turn the SENSITIVITY knob completely to the left (counter-clockwise) or completely to the right (clockwise) when directed. WARNING: ENSURE POWER IS APPLIED TO THE 231-P-INSIDER IN A SAFE MANNER WHEN PERFORMING THE FOLLOWING PROCEDURE. To Disable Rapid-Cycle Protection: (to re-enable, follow the same procedure) 1. Remove power to the 231-P-INSIDER. 2. Set the RESTART DELAY/CALIBRATION knob to RESET and the SENSITIVITY knob to the middle (12:00) position. 3. Apply power to the 231-P-INSIDER the CAL. LIGHT will turn on. 4. Turn the SENSITIVITY knob to the right the CAL. LIGHT will turn off, RUN LIGHT on. 5. Turn the SENSITIVITY knob to the left both lights will turn on. 6. Turn the SENSITIVITY knob right left right left right. 7. After 10 seconds, the CAL. and RUN LIGHTS will blink twice. USING AN INFORMER The Model 231-P-INSIDER is equipped with an infrared LED that will communicate to a SymCom Informer a handheld, battery-operated, diagnostic tool. An Informer IR Kit is required for the 231- P-INSIDER to communicate to the Informer. The Informer will display real-time voltage, current and power; dry-well and overload trip points; calibration voltage; last 20 faults; voltage, current and power at the last fault; highest/lowest voltage and current since calibration; the model number; and the CT size if applicable. The Informer can be used on any single-phase PumpSaver equipped with an infrared LED transmitter Models 111- and 231-Insiders; 231-P Insider; 112- and 232-Insiders; 111; 233-1.5 (-P); 233 (-P); 234; and 235. Contact SymCom for more information at 800-843-8848 or visit our website: www.symcom.com. 2 4/07

FRANKLIN CONTROL BOX CONNECTIONS 1. Remove the cover from the front of the 3-wire Franklin control box. 2. Remove the yellow wire from the terminal strip at L2 and remove the blue wire completely from the control box. 3. Connect the blue wire attached to the PumpSaver to the L1 terminal on the solid-state switch. 4. Press the PumpSaver onto the L1 and L2 terminals. 5. Connect the yellow wire to the bottom terminal on the PumpSaver. Figure 1: Franklin Control Box without the Model 231-P-INSIDER 3 4/07

FRANKLIN CONTROL BOX ORANGE BLUE 111/231 INSIDER SOLID-STATE SWITCH BLK RED YEL B(MAIN) Y(COMM) R(START) L2 L1 Figure 2: Franklin Control Box with the Model 231-P-Insider Installed 4 4/07

PENTEK CONTROL BOX CONNECTIONS 1. Remove the cover from the front of the 3-wire Pentek control box. 2. Remove the yellow wire from the terminal strip at L2. 3. Cut and remove the black wire connecting L1 and B (MAIN). 4. Press the PumpSaver onto the L1 and L2 terminals. 5. Reconnect the yellow wire to L2 on the PumpSaver. 6. Connect the blue wire attached to the PumpSaver to the dual-lug terminal with the black wire at the top of the capacitor. Figure 3: Pentek Control Box without the Model 231-P-Insider Installed 5 4/07

PENTEK CONTROL BOX Figure 4: Pentek Control Box with the Model 231-P-Insider Installed 6 4/07

CONNECTIONS CENTRIPRO CONTROL BOX 1. Remove the cover from the front of the 3-wire CentriPro control box. 2. Remove the yellow wire from the terminal strip at L2. 3. Remove the black wire connecting L1 and the capacitor completely from the box. 4. Press the PumpSaver onto the L1 and L2 terminals. 5. Reconnect the yellow wire to L2 on the PumpSaver. 6. Connect the blue wire attached to the PumpSaver to the dual-lug terminal (with the black wire) of the capacitor. Figure 5: CentriPro Control Box with the Model 231-P-Insider Installed 7 4/07

TROUBLESHOOTING RUN LIGHT CAL LIGHT PROBLEM or FUNCTION CORRECTIVE ACTION On Steady Off RUN: Pump is running or ready to run no problems in operation If pump is not running, check for loose wiring and ensure proper function of pressure or float switches. On Steady On Steady CAL: The PumpSaver is in the calibration process. None Off On Steady CAL COMPLETE: The PumpSaver has calibrated, the RESTART DELAY/ CALIBRATION knob was left in the CAL position. Pump is off. Pump will restart as soon as the RESTART DELAY/ CALIBRATION knob is rotated out of the CAL position. Off Off OFF / MANUAL RESTART: The pump is not running. Either the PumpSaver has tripped on dry-run, dead-head, or overload while the RESTART DELAY/ CALIBRATION knob was in the RESET position or source power is not present. If knob is in the RESET position, rotate out of RESET If the CAL light blinks, check for an overload condition. If the RUN light blinks, look for a dry-run or dead-head condition. If no lights come on, check incoming power for adequate voltage. Blinking Off DRY RUN / DEAD HEAD: The PumpSaver has shut the pump off due to a dry run or dead head condition. The unit is timing through the restart delay and will try to restart. Check for restricted flow or inadequate supply of liquid. Off Blinking OVERLOAD: Check for low or high voltage or The PumpSaver has shut the pump off jammed pump impellers. If these due to an overload condition. The unit conditions do not exist, recalibrate is timing through the restart delay and the unit while it is drawing higher will try to restart if line voltage is at an current (amps should not exceed acceptable level. SFA). Blinking alternately with the CAL. LIGHT Blinking alternately with the RUN LIGHT VOLTAGE FAULT: The PumpSaver is preventing the pump from starting due to voltage problems. The voltage is being interrogated and the unit will remain in this mode until the voltage is at an acceptable level. If the unit remains in this state for more than 5 seconds, check for high or low voltage. Blinking in unison with the CAL. LIGHT Blinking in unison with the RUN LIGHT RAPID CYCLE: The PumpSaver has shut down on rapid cycling. Power must be removed and reapplied to reset the unit. Check for a broken bladder in the pressure tank (if used), or check for a defective pressure or float switch. 8 4/07

Single-Phase Line Voltage Load Range Frequency Operating Points Overload Underload (dry-well) Overvoltage Undervoltage MODEL 231-P-INSIDER SPECIFICATIONS Number of restarts allowed in a 60- second period (rapid-cycling) Trip Delay Times Overload Dry-well Restart Delay Times Over/undervoltage All other faults Output Contact Rating SPDT Electrostatic Discharge (ESD) Safety Marks UL Power Consumption Weight Operating Temperature 230VAC 1/3 to 1hp 50/60Hz Note: 50Hz will increase all delay timers by 20% 125% of calibration point Adjustable 265VAC 190VAC 4 5 seconds 4 seconds 2 seconds manual, 2-255 minutes 1hp, 240VAC (17 amps max.) IEC 1000-4-2, Level 2, 4kV contact, 6kV air UL508 5 Watts (max.) 10 oz. -40 to 70 C (-40 to 158 F) CSA LR 46510-12 SymCom warrants its standard products against defects in material or workmanship for a period of five (5) years from the date of manufacture except for Power Perfect which is warranted for twelve (12) months. All third-party products are warranted by their manufacturer and are handled as a pass-through warranty by SymCom. All custom and private labeled products are warranted for eighteen (18) months unless otherwise stated in writing. The liability of SymCom is limited, at its option, to replace, repair, or credit at the purchase price, for any devices which are returned during the warranty period that prove to be defective. 9 4/07

10 4/07

11 4/07

Visit us at www.symcom.com to see our complete product listing! Can t find what you re looking for? SymCom designs and manufactures custom control boards too. Call us for details! 2880 North Plaza Drive, Rapid City, SD 57702 (800) 843-8848 (605) 348-5580 www.symcom.com 12 4/07