Routine Burner Service

Similar documents
VAL6 KBE5S. Service Manual

Service Manual. Contents. Names of components. 3. Specifications Wiring Diagam Sequence Time Chart

PAGE 1. TES Operation & Testing Guidelines: Tes Trouble shooting

HVF110, 210, 310, 410HD

Troubleshooting Guide

VAL6 Infrared Heater KBE5S & KBE5L. (2-step) Maintenance Manual

EC 200 EC 300 GE 360 GE 400 GE 600 L-S BM

CHALLENGER Propane to Natural Gas Instructions

SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION

Oil - kerosene burner

M-SERIES DIAPHRAGM COMPRESSOR REBUILD KIT

Heating and Gas Installations - December 2014

Installation Manual. English. French

Preventative Maintenance Tune-ups

TROUBLESHOOTING. 1. What is the model and serial number? If you don t know, how old is it? Give description.

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev V

Light oil - kerosene burner

Replacement Parts List. Armor Condensing Water Heater. AW 151 thru 801. AWII-RP_ _ _Rev W

LIBERTY APPROVED OIL BURNERS AND SPECIFICATIONS. Supplemental Installation and Operating Instructions OIL-FIRED WATER AND STEAM BOILERS / NO.

Hydraulic Pumping System

Legacy Combustion Chamber Replacement Kit

Figure 1-1(d) Tft Installation Kit

LA11 Tail, Parking, And Back-Up

CODE MODEL TYPE G3BF 490T G5BF 492T G5BF 489T53

Heater Parts. LXi Low NOx. See Detail on next page Zodiac Pool Systems, Inc. Product Catalog. Heater Parts. After. July Before.

N-084M and N-069M-DV Series Heat Exchanger Replacement

Replacement Parts List. Armor Condensing Water Heater. AW 150 thru 800

SER'IICING. CORlJAIR HEATER. the

CHEM-TEX POWER MAX 25 GOLD EDITION TRUCK MOUNT MANUAL

OPERATION MANUAL MCX-2F Multiple Coolant Exchanger

COLT 2310, 2510, AND 2712 COM PACT TRACTORS CHAPTER 9 TROUBLESHOOTING AND ANALYSIS

OWNER'S MANUAL WARNING DANGER. Propane cylinders sold separately. The propane cylinder must be disconnected when this firebowl is not use.

Kerosene - oil burner

NSGV PT-1000 PORTABLE WELDING STATION I, O & M MANUAL

TECHNICAL INSTRUCTIONS

Installation- and maintenance instruction ST120 S75/21

Troubleshooting:Passenger Car

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

HVF110, 210, 310, 410HD

INSTALLATION OPERATION/ MAINTENANCE INSTRUCTIONS AND PARTS LIST

Webasto Product North America North Road Fenton, MI Phone: Fax:

Voltmaster Centrifugal Trash Pumps

SECTION 4 - FUEL SYSTEMS AND CARBURETION

Jeep Wrangler TJ 4.0 LITER Installation instructions

Installation Instructions

OPERATION MANUAL MCX-2HD Multiple Coolant Exchanger

SERVICE MANUAL. K Series Gas Kettles 2/3 Jacketed Stationary and Tilting - NOTICE - K40GL Shown

Instructions. Certifications Chrome less spray Chrome with spray 10-K82-WNCH-AD-Z Chrome less spray 10-K82-WYCH-AD-Z Chrome with spray

AEROMOTIVE Part # Mustang 5.0L Fuel System Kit INSTALLATION INSTRUCTIONS

RAYPAK ILLUSTRATED PARTS LIST

SPARE PARTS EXPLODED VIEW GAS WALL BOILERS

Section 7 - Troubleshooting Guide

AIR CLEANER GENERAL REMOVAL. 1CAUTION Do not run engine without filter element in place. Debris could be drawn into the engine causing damage.

THIS GUIDE IS INTENDED FOR DEALERS AND SOLAR COMFORT TECHNICIANS ONLY AND IS NOT MEANT OR INTENDED TO BE REPRODUCED OR DISTRIBUTED TO THE CONSUMER

Part List: Jandy LXI Series Heaters

MAINTENANCE SCHEDULE

High Pressure Abrasive Blast Cabinet 42000

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin LowNOx Commercial Gas Electronic Spark Ignition Sequence

Instant Chat off the main page of Or simply call our tech team at

COMMERCIAL MODELS: XTHERM 1005A THROUGH 2005A

BEFORE BEGINNING INSTALLATION

Operator s Manual. Table of Contents

CIRRUS AIRPLANE MAINTENANCE MANUAL

DISPLACEMENT PUMP INSTRUCTIONS-PARTS LIST Rev. K. Model , Series A Model , Series B Model , Series A

Retro it Steering Column

Installation- and maintenance instruction BENTOFLEX ST 108 PL

Installation- and maintenance instruction B20KA/K

Installation- and maintenance instruction B20KAV/KV

BBK Intake Manifold Kit ( L) - Installation Instructions

SPARE PARTS LIST. for. Infrared oil heater. Model. Type. EPX5 for 120V 60Hz. May, 2017

Nissan GTR Alpha Fuel System

ALTITUDE KIT FOR 79CC GASOLINE INVERTER - Westinghouse Part No

Typical Install Instructions

Installation Instructions

RAYPAK ILLUSTRATED PARTS LIST

Table of Contents. Safety Assembly Pre-operation / Starting. 7. Operation.. 8. Maintenance. 9. Storage 10

Installation- and maintenance instruction B20KA/K


Mobile Diesel Heaters GRY-D / GRY-I Service Training Course

RAYPAK ILLUSTRATED PARTS LIST

Troubleshooting 3Z8 038 Rev B

SOLO VACUUM OPERATING & MAINTENANCE

Pypes Polished Shorty Headers (05-10 V6):

Installation- and maintenance instruction BENTOFLEX ST120KAV

Heater Manifold REPLACEMENT INSTRUCTIONS. Sta-Rite Pool/Spa Group. 293 Wright Street, Delavan, WI 53115

QSSE, QSSEX INDUSTRIAL Battery Chargers

IMPORTANT INFORMATION

FABER BURNER ROUTINE MAINTENANCE

Prerequisites: Shop Manual (recommended) pages 3-9 through 3-13.

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

AEROMOTIVE Part # INSTALLATION INSTRUCTIONS

L Intake Manifold Part #

Replacement Parts List. Knight Fire Tube Boilers. KH 55 thru _ _Rev D

I Button Chemical Dispenser. Overview. Installation Instructions

PumpAgents.com - Click here for Pricing/Ordering Fuse Size (A) Open Flow GPM (LPM)

Catalytic Failures. Engine running too hot.

Motion System Components Diagram. Note: #2 Mirror Cover and X-Axis Motor Cover have been removed for visibility. Maintenance.

HALLMARK INDUSTRIES INC

Model &

Read all instructions carefully before attempting installation. 1633S-1JS Shown. Rev DSL

Transcription:

Routine Burner Service WARNING Rural Energy Enterprises, Inc. does not accept liability for the improper use of this information. Installation, service, and maintenance of heating equipment should be performed by a qualified technician. Improper installation, adjustment, alteration, service, or maintenance can cause property damage, personal injury, or loss of life. Applies to models Oil Miser 148, 180 and Toyotomi BS36UFF: 1. Unplug the unit and shut off the oil supply line. 2. Inspect the filter at the oil tank and fuel lines. (Filter should be changed annually.) 3. Remove the front panel and the circuit board cover on left hand side. 4. Remove and inspect the fuel strainer cartridge. Replace cartridge if signs of water and/or sludge are present. Part numbers for the cartridges are as follows: BS-36UFF (Type A) BS-36UFF (Type B) & OM-148/180 part# 20476484 (fuel strainer cartridge) part# 17185384 (fuel strainer cartridge) 5. Unplug the following connections from the main circuit board: Blower Motor (G), Ignition Transformer (H), Fuel Pump (F) and Flame Sensor (D). On the OM-148 & OM-180 also unplug the Temperature Fuse (Q) 6. Remove the 2 screws holding the pressure switch to the cabinet (right hand side) and the ground wire from the base of the unit. (right hand side)

7. Remove the oil line section going between the fuel strainer and the fuel pump. (17mm on pump, 14mm on strainer, & 12mm on fuel line). Use a backup wrench as pictured. 8. Remove the 3 short screws holding the combustion air intake tube from the burner assembly. There are 3 large nuts holding the burner assembly to the heat exchanger. Loosen the one at 3 o clock. Remove the other two (at 7 o clock and 11 o clock). With your left hand holding the top of the burner assembly (top of blower motor), remove the remaining loose nut. 9. Pull burner assembly from unit. (Be careful of the wires.)

10. Lay burner on a work station. 11. Remove the 3 screws holding the burner top and pull off. 12. Mark the bottom burner top holder with a felt pen/marker from the ring to the faceplate. Remove the 4 screws on the faceplate edge and the 3 screws (not all models had this) to bracket of the nozzle assembly. 13. Clean burner top, paying special attention to the combustion air holes. Make sure they are free of carbon, soot and dust. Replace burner top if necessary. 14. Remove and replace the fuel nozzle. BS-36UFF OM-148 & OM-180 part# 20476426 Delavan 1.10 gph, 60-degree, type A part# 20476626 Delavan 0.85 gph, 60-degree, type XA 15. Inspect the electrodes, if pitted or worn, replace. Electrodes can be bent a little bit to close the gap, but if a lot of bending is required, replace the electrodes. To help ensure the best gap possible use electrodes setting tool part # 10005027 only for models OM-148 & OM-180 BS-36UFF OM-148 & OM-180 part# 20476425 electrodes (set of 2) part# 20476625 electrodes (set of 2).

16. Reinstall the burner top holder, matching the mark on the base faceplate with the felt pen mark, then the burner top. 17. Turn over burner assembly to access flame sensor. 18. On the BS-36UFF pull the flame sensor from housing and clean lens. On the OM- 148/180, the ignition transformer and backing plate will need to be removed for access to the sensor. Remove (snaps out) and clean the flame sensor, reinstall, (note the ridge on the sensor) to make sure it snaps into place properly, reinstall the back plate and ignition transformer. 19. Vacuum out the burn chamber; inspect the inside to make sure it is clean, no warping or leaking of the heat exchanger. If there is heavy soot and carbon inside burn chamber area, the top of the heat exchanger and baffles will need to be inspected. See page # 44-45 of the service manual for instructions. Pull out and inspect baffles; if ends are burned off or broken, replace the baffles. If the muffler assembly (top of heat exchanger) needs to be removed, the heat exchanger gasket (part# 20476393) will have to be replaced, and high temperature silicone sealant used to complete the seal. If servicing a BS-36UFF or an older OM-148, now is a good time to shut off the water and drain about 1 gallon of water. Pull the empty burning preventive electrode. Clean probe with cloth (do not use sandpaper, steel wool, or other abrasive material) and wire connection. Reinstall and turn water back on. If probe is pitted or wire connection is corroded replace the electrode. Part# 20476407

Setting the Electrodes BS36UFF, OM-148, OM-180 Observing the Spark The best way to ensure proper electrode setting is to watch the spark in action. After removing and servicing the burner assembly, remove the combustion air intake from top of unit and place the complete burner assembly on top of the unit with the burner top facing the front-left corner of the unit. With the air intake removed, the assembly can lean back stably at an angle. Ensure that the burner assembly is stable before continuing you don t want it to fall. Plug the following wires into the main circuit board: Blower Motor (G), Ignition Transformer (H), Thermal Fuse (Q). ENSURE THAT THE FUEL PUMP (F) IS DISCONNECTED. Plug the unit in and press the power button. The blower motor and ignition transformer should now engage, allowing you to observe the spark. WHEN THE BLOWER ENGAGES, DEBRIS MAY BE BLOWN OUT OF THE BURNER. WEAR EYE PROTECTION. ALSO, BE CAREFUL TO PREVENT ANYTHING FROM BEING SUCKED INTO THE INTAKE OF THE BLOWER. ALWAYS UNPLUG THE UNIT BEFORE ANY ADJUSTMENTS ARE MADE. If the spark is a bright whitish/blue with only a little purplish color, the electrodes are spaced too closely together, and should be adjusted. The spark should have a nice light purple hue to it, and it should blow out towards the fuel spray. However, if the electrodes are set too far apart, the spark will lick out and touch the fuel

nozzle and/or burner top, and the electrode spacing will have to be reduced. There are metal rings on the electrodes that prevent them from being set too close to the fuel nozzle. In most cases, sliding the electrodes down until these rings touch is the proper spacing from the fuel nozzle. However, in some cases you may need to raise the electrodes a bit to prevent the spark from touching the fuel nozzle. Good spark nice light purple color :

Too close less purple, more of the bright blue-white arc: Too wide arcing to nozzle and/or burner top: 20. Reinstall the burner assembly. Be careful not to pinch any of the wires between the burner assembly and heat exchanger. 21. Reconnect wires to the proper circuit board connections.

22. Reinstall the oil line. 23. Remove the union and put fuel pump pressure gauge (part #10005089) in oil line after the pump. Open a hot water faucet. Plug in the unit and turn on. Unit should fire right away. 24. Set pump pressure as follows: BS-36UFF (Type A) (Chimney or Flue Pipe Vent) Altitude Range 0-4,992 FT 5,250-5,577 FT 5,578-6,233 FT 6,234-6,561 FT 6,562-6,890 FT Fuel Pump Pressure 95 PSI 91 PSI 85 PSI 81 PSI 77 PSI Notes Some BS-36 (A) have been set at 99 PSI before being shipped out from the manufacturer, this will cause no problems. BS-36UFF (Type B & C) (Chimney or Flue Pipe Vent) Altitude Range 0-4,992 FT 5,250-5,577 FT Fuel Pump Pressure 107 PSI 101 PSI Notes Some BS-36 (B, C) have been set to 114 PSI before being shipped out from the manufacturer, this will cause no problems.

5,578-6,233 FT 6,234-6,561 FT 6,562-6,890 FT 97 PSI 91 PSI 87 PSI OM-148/180 (Flue Pipe Vent) Altitude Range Fuel Pump Pressure 0-1,640 FT 192 PSI 1,641-3,280 FT 171 PSI 3,281-4,920 FT 149 PSI OM-148/180 (Chimney Vent) Altitude Range Fuel Pump Pressure 0-3,280 FT 192 PSI 3,281-4,920 FT 171 PSI 25. While unit is still burning, perform smoke test. Smoke test should read zero smoke. If smoke test is higher than zero, then adjust pump pressure down to decrease smoke. Fuel pump pressures listed above are approximate values to get close to zero smoke point test. Actual fuel pump pressure with zero smoke may vary depending on chimney or flue pipe length, and installation conditions. Turn off hot water faucet.

26. Turn off hot water faucet. 27. Remove pump pressure gauge and reinstall union. 28. Install front panel and circuit board cover. 29. Clean water heater cabinet and area.