RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE

Similar documents
Residual current circuit breakers with conditional shortcircuit

RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLFE (6 ka)

Basic function. Rated current. Appropriate for three-phase motors of output 2) [kw] I n. = 400 V a.c. 2) Appropriate for three-phase motors

Devices for switching and control

max pole for t=15 ms

Varius SUMMARY OF MODELS

RESIDUAL CURRENT CIRCUIT BREAKERS OFE (6 ka)

RESIDUAL CURRENT CIRCUIT BREAKERS OFI (10 ka)

IP20 degree of protection; IP40 degree of protection after installation in a distribution box

Technical Data Accessories MCBs Ex9B.

MOULDED CASE CIRCUIT BREAKERS BC160N

Varius SUMMARY OF MODELS

Varius SUMMARY OF MODELS

Modeion MOULDED CASE CIRCUIT BREAKERS BL1600S

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Protection Equipment

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

MOULDED CASE CIRCUIT BREAKERS BC160N

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

MOULDED CASE CIRCUIT BREAKERS BL1600S

Miniature Circuit-Breakers (MCBs)

MOULDED CASE CIRCUIT BREAKERS BH630N, BH630S

Selective main circuit breakers S 750 series Technical Data

AF40... AF96 3-pole contactors Technical data

Overcurrent releases - description, specifications, characteristics specifications specifications description...

Fuse switch-disconnectors

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

Residual current devices

Miniature Circuit-Breakers (MCBs)

MS25, MST25, MS20, MST20

Connecting sets CS-FS CS-FS123-WD. Connecting space covers OD-FS00-.. OD-FS123-KP. Adapter for parallel outlet - HP-SE/K

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

3VU13, 3VU16 Circuit-Breakers

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Miniature Circuit Breaker

MS25, MST25, MS20, MST20

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

D509E. Manual Motor - Starters

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

DX³ RCCBs - ID 4P up to 100 A

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Technical data. Miniature Circuit Breakers. System pro M. System pro M

SIRIUS 3RU2 Thermal Overload Relays

TAE pole Contactors

Low Voltage A GE Power Controls Company. General catalogue

Technical Information

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Electronic overload relays EF205 and EF370

Protection Equipment. 5/2 Introduction

Electronic Circuit Breaker ESS20-0..

Residual Current Protective Devices / Arc Fault Detection Devices (AFDDs)

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

Fuse switch-disconnectors

RCBOs - Residual current circuit breakers with integral overcurrent protection KZS

Control Circuit Protection

Phone: Fax: Web: -

Varius SUMMARY OF MODELS OF FUSE-BASE AND FUSE HOLDERS. Type SPB S3PB SPF SP4.. SP50

Modular contactors and relays

and other modular devices for low voltage installation

ASL09..S 3-pole Contactors - Spring Terminals

Jtec 10kA Miniature Circuit Breaker

3VT Kompaktleistungsschalter bis 630A

Modular contactor for installation into distribution boards

W DATA SHEET: COMBINED FAULT-CURRENT PROTECTIVE SWITCH, SERIES BOLF, 3P+N

TX³ RCCBs 2P up to 100 A

Electronic overload relay EF65, EF96 and EF146

Thermal-magnetic Miniature Circuit Breaker 4230-T...

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Motor Protection Circuit Breakers 3VU13 and 3VU16

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

Short form catalogue. Motor protection & control

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

Miniature circuit breakers

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

MS General Information Extended Product Type: MS

BETA Switching Switches and Light Indicators

AE 9... AE 40 Contactors NE... Contactor Relays

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Thermal overload relay TF65 and TF96

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

TM12 Series CIRCUIT BREAKERS FOR EQUIPMENT. Thermal magnetic release Positively trip-free Reset or manual actuation

3VT1 Molded Case Circuit Breakers up to 160 A

3 - Protection components Motor circuit-breakers

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Motorized switch-disconnectors OTM 40 to 125 Amperes

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Thermal-Magnetic Circuit Breaker 201/-WA

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

Technical data for manual motor starters Type MS325

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

Transcription:

OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE OLE-10B-1N-030AC The device is a combination of residual current circuit breaker and circuit breaker. Breaking capacity 6 ka. For building, housing and similar installations up to 16 A, AC 230 V. For protection: against dangerous contact with live parts (I Δn 30 ma) against dangerous contact with dead parts against fire against overload against short-circuit. Tripping characteristics B, C according to EN 61009-1. Double terminal with a fixed barrier in the middle enables comfort connection of conductors and interconnecting busbar from both sides of the device. It enables connection of: conductors of various cross sections up to 4 conductors in the terminal conductor of cross section up to 35 mm 2. Double terminal enables easy check of conductors at simultaneous connection of interconnecting busbar - the interconnecting busbar does not cover the conductor connecting place - see the LTN terminal on page B3. Wide range of accessories auxiliary and signal switches, undervoltage releases and shunt trips, interconnecting busbars. Possibility of locking and sealing in off or on position. Residual current circuit breakers with overcurrent protection, type AC They react to sine-wave residual current (type AC). 6 000 3 I Δn I n Characteristic B Characteristic C Number Weight Package [ma] [A] Type Order code Type Order code of modules [kg] [pcs] OD-LT-VP01 30 6 OLE-6B-1N-030AC OEZ:38313 OLE-6C-1N-030AC OEZ:38320 2 0.25 1 10 OLE-10B-1N-030AC OEZ:38314 OLE-10C-1N-030AC OEZ:38321 2 0.25 1 16 OLE-16B-1N-030AC OEZ:38315 OLE-16C-1N-030AC OEZ:38322 2 0.25 1 20 OLE-20B-1N-030AC OEZ:38316 OLE-20C-1N-030AC OEZ:38323 2 0.25 1 25 OLE-25B-1N-030AC OEZ:38317 OLE-25C-1N-030AC OEZ:38324 2 0.25 1 32 OLE-32B-1N-030AC OEZ:38318 OLE-32C-1N-030AC OEZ:38325 2 0.25 1 40 OLE-40B-1N-030AC OEZ:38319 OLE-40C-1N-030AC OEZ:38326 2 0.25 1 OD-LT-VU01 SS-LT PS-LT Accessories Auxiliary and signal switches PS-LT, SS-LT page B36 Shunt trips SV-LT page B37 Undervoltage releases SP-LT page B37 Interconnecting busbars S2L, S2L+N, S3L+N page B45 Terminal extensions AS-50-S-AL01 page B47 Locking inserts OD-LT-VU01 page B38 Sealing insert OD-LT-VP01 page B39 Installation requires OD-OL-NR01 handle adapter. SV-LT S2L+N AS-50-S-AL01 OD-OL-NR01 OL SP-LT Specifications Type OLE Standards EN 61009-1 Approval marks Number of poles 2 Tripping characteristics B, C Type AC Rated current I n 6 40 A Rated residual current I Δn 30 ma Rated operating voltage U e AC 230 V Min. operating voltage U min AC 100 V Max. operating voltage U max AC 255 V Rated frequency f n 50 60 Hz Surge resistance (8/20 μs) 1 ka Rated short-circuit breaking capacity I cn 6 ka Rated residual making and breaking capacity I Δm 6 ka Rated impulse withstand voltage (1.2/50 μs) U imp 6 kv Mechanical endurance 10 000 operating cycles Electrical endurance 10 000 operating cycles Energy limitation class 3 Degree of protection IP20 Mounting on U rail according to EN 60715 type TH 35 Connection Conductor Cu see table Connection range on page C19 Torque 2.5 3 Nm Top or bottom connection top/bottom Operating conditions Ambient temperature -5 40 C Working position arbitrary arbitrary For preserving the function of the test push-button C18

OLE Residual current circuit breakers Minia RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE Connection range Type and cross-section of conductor for rear side of the terminal Front side of the terminal Barrier Rear side of the terminal Type and cross-section of conductor for front side of the terminal Interconnecting busbar 0.75 10 mm 2 16 mm 2 1x conductor rigid 25 mm 2 0.75 6 mm 2 2x conductor rigid 1 6 mm 2 10 mm 2 1x conductor flexible 16 mm 2 1 2.5 mm 2 2x conductor flexible 4 mm 2 0.75 6 mm 2 10 mm 2 1x conductor flexible with a sleeve 16 mm 2 0.75 2.5 mm 2 4 mm 2 2x conductor flexible with a sleeve 0.75 16 mm 2 1x conductor rigid 25 mm 2 35 mm 2 2x conductor rigid 0.75 10 mm 2 1 16 mm 1x conductor rigid 2 25 mm 2 2x conductor rigid 1 6 mm 2 0.75 16 mm 1x conductor flexible with a sleeve 2 25 mm 2 2x conductor flexible with a sleeve 0.75 6 mm 2 The conductor must be twisted before insertion to a terminal; individual conductor fibres must not stick out of the terminal. Conductors of the same type and cross-section must be used for connection of two conductors to the same level of a terminal. Internal impedance Z and powers losses P Characteristic B Characteristic C I n L-Pole N-Pole Power loss L-Pole N-Pole Power loss [A] Z [mω] Z [mω] P [W/pole] Z [mω] Z [mω] P [W/pole] 6 72.0 2.1 2.7 52.0 2.1 1.9 10 15.4 2.1 1.8 13.4 2.1 1.6 16 9.6 2.1 3.0 8.7 2.1 2.8 20 7.1 2.1 3.7 6.1 2.1 3.3 25 6.1 2.1 5.1 6.0 2.1 5.1 32 4.1 1.5 5.7 4.1 1.5 5.7 40 3.4 1.5 7.8 3.4 1.5 7.8 Correction of rated currents I n 2) Correction of rated currents for ambient temperature -25 C up to + 40 C [A] [A] -10 C 0 C 10 C 20 C 30 C 40 C 6 6.8 6.7 6.4 6.2 6 5.7 10 11.4 11.2 10.7 10.4 10 9.5 16 18.2 17.9 17.1 16.6 16 15.2 20 22.8 22.4 21.4 20.8 20 19.0 25 28.5 28.0 26.8 26.0 25 23.8 32 36.5 35.8 34.2 33.3 32 30.4 40 45.6 44.8 42.8 41.6 40 38.0 2) Reference temperature: 30 C Dimensions Diagram 73.3 1 N 90 45 90 2 N 36 7 44 64 70 C19

OLE Residual current circuit breakers RESIDUAL CURRENT CIRCUIT BREAKERS WITH OVERCURRENT PROTECTION OLE Characteristics 10 000 120 5 000 60 30 1.13 In 1.45 In At ambient temperature 30 C Characteristic B: for protection of line of electrical circuits with equipment, which does not cause current surges (lighting and socket circuits etc.). The short-circuit release is set to (3 5) I n. Characteristic C: for protection of line of electrical circuits with equipment, which causes current surges (light bulb groups, motors etc.). The short-circuit release is set to (5 10) I n. min 10 1 000 500 5 2 1 t v [s] 100 50 10 5 1 0.5 0.1 0.05 0.01 B C 1 1.5 2 3 4 5 6 7 8 9 10 20 30 40 Tripping characteristics of circuit breakers according to EN 61009-1 Thermal release Tripping characteristic type B, C Conventional non-tripping current I nt for t 1 hr I nt = 1.13 I n Conventional tripping current I t for t < 1 hr I t = 1.45 I n Current I 3 for 1 s < t < 60 s and I n 32 A I 3 = 2.55 I n t - break time of the circuit breaker Electromagnetic release Tripping characteristic type B C Current I 4 for 0.1 s < t < 45 s (for I n 32 A) I 4 = 3 I n 0.1 s < t < 15 s (for I n 32 A) I 4 = 5 I n Current I 5 for t < 0.1 s I 5 = 5 I n I 5 = 10 I n t - break time of the circuit breaker xln Characteristics I 2 t 100000 80 000 60 000 OLE-..B-.. 100000 80 000 60 000 OLE-..C-.. 40 000 20 000 10 000 8 000 6 000 25/32/40A 16/20 A 10 A 6A 40 000 20 000 10 000 8000 6000 20/25/32/40 A 16 A 10 A 6A 4 000 4000 I t [A s] 2 2 2 000 1 000 800 600 I t [A s] 2 2 2000 1000 800 600 400 400 200 200 100 100 100 200 400 600 800 100 200 400 600 800 1 000 2 000 4 000 6 000 1 000 2 000 4 000 6 000 I [A] p I [A] p C20

Miniature circuit breakers Auxiliary switches PS-LT-0200-TE miniature circuit breakers: LTP, LTK, LTS, LVN, LTN-UC residual current circuit breakers: LFN, LFE residual current circuit breakers with overcurrent protection: OLI, OLE (installation on OLI/OLE requires handle adapter OD-OL-NR01 see page B38 except for PS-LT-1100-K) switches: MSO, MSN, AVN-DC. For signalling the position of contacts of the device in switching off by releases or manually, i.e. in switching off by overload, short-circuit, shunt trip or undervoltage release, residual current and manually by control lever. Mounting on the right side of the device. For the number of auxiliary switches connected to the device in combination with the other accessories see page B44. Width 9 mm. Auxiliary switch function can be checked by test lever on the front side of the device (version PS-..-TE). Variant for switching small direct current voltages up to DC 30 V. They are suitable for application in SELV and PELV circuits - sufficient insulation is provided between the circuit breaker and the auxiliary switch. PS-LT-0200 Design Arrangement Type Order Number Weight Package of contacts code of modules [kg] [pcs] 11 PS-LT-1100 OEZ:42297 0.5 0.065 1 Standard 20 PS-LT-2000 OEZ:42299 0.5 0.071 1 02 PS-LT-0200 OEZ:42298 0.5 0.065 1 11 PS-LT-1100-TE OEZ:42300 0.5 0.054 1 With test and reset lever 20 PS-LT-2000-TE OEZ:42302 0.5 0.058 1 02 PS-LT-0200-TE OEZ:42301 0.5 0.080 1 For small voltages standard 11 PS-LT-1100-MN OEZ:42303 0.5 0.075 1 For small voltages with test lever 11 PS-LT-1100-MN-TE OEZ:42304 0.5 0.054 1 With handle adapter OD-OL-NR01 2) 11 PS-LT-1100-K OEZ:42305 0.5 0.065 1 Each digit indicates successively the number of make and break contacts. 2) PS-LT-1100-K is a set for convenient ordering in installation on OLI/OLE. The other designs of the auxiliary switches installed on OLI/OLE require separate ordering of OD-OL-NR01. SS-LT-2000 SS-LT-2000-TE-RE Signal switches miniature circuit breakers: LTP, LTK, LTS, LVN, LTN-UC residual current circuit breakers: LFN, LFE residual current circuit breakers with overcurrent protection: OLI, OLE (installation on OLI/OLE requires handle adapter OD-OL-NR01 see page B38) switches: MSN. For position signalling of main contacts of the device in switching off by releases, i.e. in switching off by overload, short-circuit, shunt trip and undervoltage release or residual current. Mounting on the right side of the device. For the number of auxiliary switches connected to the device in combination with the other accessories see page B44. Auxiliary switch function can be checked by test lever on the front side of the device (version SS-..-TE). Signal switch can be reset by means of the red reset lever on the front side of the device without switching the device on by the control lever (version SS-..-RE). They are suitable for application in SELV and PELV circuits - sufficient insulation is provided between the circuit breaker and the signal switch. Reaction in switching off by releases: in switching off by releases the make/break contact will break/make for details see the table on page B44. Design Arrangement Type Order Number Weight Package of contacts code of modules [kg] [pcs] 11 SS-LT-1100 OEZ:42306 0.5 0.065 1 Standard 20 SS-LT-2000 OEZ:42307 0.5 0.075 1 02 SS-LT-0200 OEZ:42308 0.5 0.078 1 11 SS-LT-1100-TE-RE OEZ:42309 0.5 0.055 1 With test and reset lever 20 SS-LT-2000-TE-RE OEZ:42310 0.5 0.057 1 02 SS-LT-0200-TE-RE OEZ:42311 0.5 0.057 1 Each digit indicates successively the number of make and break contacts. B36

ture circuit breakers Minia Shunt trips miniature circuit breakers: LTS, LVN, LTN-UC residual current circuit breakers: LFN, LFE residual current circuit breakers with overcurrent protection: OLI, OLE (installation on OLI/OLE requires handle adapter OD-OL-NR01 see page B38) switches: MSN. They are used for device switching off by applied voltage. Mounting: on the right side of the device one shunt trip can be connected to one device in combination with the other accessories - see page B44. SV-LT-X400 Rated voltage Type Order Number Weight Package U c code of modules [kg] [pcs] AC/DC 24 60 V SV-LT-X060 OEZ:42312 1 0.106 1 AC 110 415 V / DC 110 220 V SV-LT-X400 OEZ:42313 1 0.098 1 Undervoltage releases miniature circuit breakers: LTS, LVN, LTN-UC residual current circuit breakers: LFN, LFE residual current circuit breakers with overcurrent protection: OLI, OLE (installation on OLI/OLE requires handle adapter OD-OL-NR01 see page B38) switches: MSN. They are used for tripping the device at loss of voltage as well as at gradual decrease of voltage. They are used for elimination of closing of circuit breaker if voltage is lower than 35 % U c (switching is possible at voltage higher than 85 % U c ). They are often used for protection against device restart following mains failure. Mounting: on the right side of the device one undervoltage release can be connected to one device in combination with the other accessories - see page B44. SP-LT-A230 Rated voltage Arrangement Type Order Number Weight Package U c of contacts code of modules [kg] [pcs] AC 230 V - SP-LT-A230 OEZ:42315 1 0.109 1 20 SP-LT-A230-2000 OEZ:42317 1 0.123 1 DC 24 V - SP-LT-D024 OEZ:42319 1 0.113 1 20 SP-LT-D024-2000 OEZ:42321 1 0.117 1 DC 110 V - SP-LT-D110 OEZ:42320 1 0.105 1 20 SP-LT-D110-2000 OEZ:42322 1 0.128 1 Each digit indicates successively the number of make and break contacts. B37

Miniature circuit breakers OD-OL-NR01 Handle adapter OD-OL-NR01 OLI, OLE. It enables installation of the following accessories on residual current circuit breakers with overcurrent protection OLI, OLE auxiliary switches (PS-LT) signal switches (SS-LT) undervoltage releases (SP-LT) shunt trips (SV-LT). Special auxiliary switch PS-LT-1100-K contains the handle adapter OD-OL-NR01. So it is not necessary to order it separately. Type Order Weight Package code [kg] [pcs] OD-OL-NR01 OEZ:38270 0.02 5 Example of installation 2 OD-OL-NR01 3 1 3 5 4 5 6 5 Locking insert OD-LT-VU01 miniature circuit breakers: LTK, LVN, LTN-UC residual current circuit breakers: OLI, OLE switches: MSN, AVN-DC. For safe locking of the control lever in off or on position. The protective function of the devices is functional even in locked position. Maximum diameter of lock rod - 3 mm. The lock is not included in the package. Type Order Weight Package code [kg] [pcs] OD-LT-VU01 OEZ:42324 0.012 1 OD-LT-VU01 B38

ture circuit breakers Minia OD-LT-VU02 Locking insert OD-LT-VU02 miniature circuit breakers: LTP, LTS residual current circuit breakers: LFN, LFE switches: MSO. For safe locking of the control lever in off or on position. The protective function of the devices is functional even in locked position. Maximum diameter of lock rod - 6 mm. The lock is not included in the package. In installation it is necessary to press the fixing springs of the insert by two fingers against each other, and then slide them in the holes in the circuit breaker. In case of pressing the insert against the circuit breaker body a part of the plastic cover could break off! Type Order Weight Package code [kg] [pcs] OD-LT-VU02 OEZ:42325 0.003 1 Sealing insert OD-LT-VP01 miniature circuit breakers: LTP, LTS, LVN, LTN-UC residual current circuit breakers: OLI, OLE switches: MSO, MSN, AVN-DC. For covering and sealing of terminal screws. OD-LT-VP01 Type Order Weight Package code [kg] [pcs] OD-LT-VP01 OEZ:42323 0.002 1 B39

Miniature circuit breakers Specifications of auxiliary and signal switches DC-13 2) Type PS-LT PS-LT-1100-MN SS-LT PS-LT-1100-MN-TE Standards EN 60947-5-1 EN 60947-5-1 EN 62019 EN 62019 Approval marks Arrangement of contacts 11, 20, 02 11, 20, 02 Rated operating voltage/current U e /I e 400 V 2 A - AC-13 230 V 6 A - AC-14 400 V 2 A - 230 V 6 A - 110 V 1 A/0.75 A - 60 V 3 A/1.5 A - 220 V 1 A/0.5 A - 24 V 6 A/3 A - Max. voltage/current - DC 30 V / 100 ma Min. voltage/current 24 V / 50 ma DC 5 V / 1 ma Backup protection - fuse / miniature circuit breaker 6 A gg / 6 A characteristic B, C 6 A gg / 6 A characteristic B, C Mechanical endurance 10 000 operating cycles 10 000 operating cycles Electrical endurance at I e 10 000 operating cycles 10 000 operating cycles Degree of protection IP20 IP20 Connection Conductor Cu rigid (solid, stranded) 0.5 2.5 mm 2 0.5 2.5 mm 2 Conductor Cu flexible 0.5 2.5 mm 2 0.5 2.5 mm 2 Torque 0.5 Nm 0,5 Nm Connection top/bottom top/bottom Operating conditions Ambient temperature -25 +55 C -25 +55 C Working position arbitrary arbitrary Climatic resistance according to IEC 60068-2-30 28 operating cycles 28 operating cycles Shocks (EN 60068-2-27) m/s 2 150 in 11 ms half-sine pulse 150 in 11 ms half-sine pulse Vibration resistance according to IEC 60068-2-6 m/s 2 50 at 10 150 Hz 50 at 10 150 Hz Each digit indicates successively the number of make and break contacts. 2) Value according to EN 62019 / according to EN 60947-5-1 Function of signal switch SS-LT Circuit breaker contact state The state of the MAKE signal contact SS-LT- * Initial position - contacts open switched off Switching on manually - contacts closed switched on Switching off manually - contacts open switched on Switching off by release - contacts open switched off * The break contact works in opposite way. B40

ture circuit breakers Minia Specifications of shunt trips and undervoltage releases Type SV-LT SP-LT Standards EN 60947-1 EN 60947-1 Approval marks Mounting on the right side of the device on the right side of the device Degree of protection IP20 IP20 Control circuit coil Rated voltage U c AC/DC 24 60 V AC 230 V AC 110 415 V / DC 110 220 V DC 24, 110 V Range of rated voltage 0.7 1.1 U c 0.85 1.1 U c Voltage range for switching off - < 0.35 0.7 U c Rated frequency f n 50/60 Hz 50/60 Hz Backup protection - fuse / miniature circuit breaker 6 A gg / 6 A characteristic B, C 6 A gg / 6 A characteristic B, C The length of impulse necessary for device switching off 15 ms Contact Arrangement of contacts - 20 Rated operating voltage/current U e /I e AC-1-230 V / 6 A Min. voltage/current - 24 V / 50 ma Backup protection - fuse / miniature circuit breaker - 6 A gg / 6 A characteristic B, C Connection Conductor Cu rigid (solid, stranded) 0.5 2.5 mm 2 0.5 2.5 mm 2 Conductor Cu flexible 0.5 2.5 mm 2 0.5 2.5 mm 2 Torque 0.8 Nm 0.8 Nm Connection top/bottom top/bottom Operating conditions Mechanical endurance 10 000 operating cycles 10 000 operating cycles Electrical endurance 2 000 operating cycles 2 000 operating cycles Ambient temperature -25 +55 C -25 +55 C Working position arbitrary arbitrary Climatic resistance according to IEC 60068-2-30 28 operating cycles 28 operating cycles Shocks (EN 60068-2-27) m/s 2 50 in 11 ms half-sine pulse 50 in 11 ms half-sine pulse Vibration resistance according to IEC 60068-2-6 m/s 2 50 at 10 150 Hz 50 at 10 150 Hz Each digit indicates successively the number of make and break contacts. B41

Miniature circuit breakers Dimensions PS-LT, SS-LT 73.3 SV-LT SP-LT 73.3 C1 D1 13 23 24 45 9 6 44 64 68.5 48.4 90 45.1 89.8 C2 D2 14 17.6 17.6 6.4 43 63.1 67.6 LTK, MSN, OLI, OLE, AVN-DC, LTN-UC, LVN + OD-LT-VU01 + OD-LT-VP01 OD-LT-VP01 4 OD-LT-VU01 61.5 17.6 69.8 19.6 LTP, LTS, MSO + OD-LT-VU02 17.6 68.3 7.7 B42

ture circuit breakers Minia Diagram PS-LT-1100, PS-LT-1100-K PS-LT-2000 PS-LT-0200 SS-LT-1100 SS-LT-2000 SS-LT-0200 13 21 13 23 11 21 13 21 13 23 11 21 14 22 14 24 12 22 14 22 14 24 12 22 PS-LT-1100-TE PS-LT-2000-TE PS-LT-0200-TE SS-LT-1100-TE-RE SS-LT-2000-TE-RE SS-LT-0200-TE-RE 13 21 13 23 11 21 13 21 13 23 11 21 TEST TEST TEST TEST TEST TEST 14 22 14 24 12 22 14 22 14 24 12 22 SV-LT-.. SP-LT SP-LT-..-2000 C1 C2 D1 A1 13 23 U< U< D2 D2 14 24 Installation of auxiliary switch, shunt trips or undervoltage releases For installation of an auxiliary switch, shunt trip or undervoltage releases on a circuit breaker, residual current circuit breaker or switch, the same procedure shall apply as described on the example of installation of the auxiliary switch on the circuit breaker in the following points. 1. In mounting the levers of auxiliary switch and of the circuit breaker are in ON position. 2. Tilt both fixing springs of the auxiliary switch to the right so that they do not get between the auxiliary switch and circuit breaker in installation. 3. Slide the auxiliary switch onto the circuit breaker from the right. 4. Lock the fixing springs in the circuit breaker body so that the auxiliary switch cannot release. 5. Check correct function by switching. 2 3 4 4 1 5 2 4 B43

Miniature circuit breakers Combination of accessories LTP, LTK Any combination of PS-LT and SS-LT, max. 2 units Any combination of PS-LT and SS-LT, max. 2 units or LTS, LFE, LFN, OLE, OLI* SV-LT * Installation of accessories on OLI/OLE requires handle adapter OD-OL-NR01 see page B38. SP-LT Any combination of PS-LT and SS-LT, max. 2 units Any combination of PS-LT and SS-LT, max. 3 units or LTN-UC, LVN, MSN* SV-LT * Installation of signal switches SS-LT on the MSN switch, only with SP-LT or SV-LT SP-LT Any combination of PS-LT and SS-LT, max. 3 units B44 MSO, AVN-DC PS-LT max. 3 units