N Daily Weekly Monthly Every 3 months. Every 6 months 1 Remove any materials not related

GENERALITIES TECHNICAL FEATURES

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

MODEL ELC-12/40-CVM-D BATTERY CHARGER

LESTRONIC II BATTERY CHARGER TAYLOR-DUNN MODEL TYPE 24LC25-8ET

ST Charger. Industrial Battery Charger

MULTIVOLTAGE PORTABLE BATTERY CHARGER MVM

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 1672 Triple Output Power Supply

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

BATTERY CHARGER-STARTER

USER MANUAL GEBRUIKSAANWIJZING GEBRAUCHSANWEISUNG SKYLLA 24/100 3-PHASE CE

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

XENON POWER SUPPLY for 10 kw Britelight Lamphead

User Manual Rittal PMC UPS 6kVA

Switching DC Power Supply

Compact System NRGS 11-2 NRGS Original Installation Instructions English

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

World Class Power Solutions. Rectifiers. For Stationary Battery Systems in Nuclear Power Plants

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Table of Contents Foreword I. Product Introduction II. Notice For Safety III. Main Technical Parameters IV.

XENON POWER SUPPLY 4000 Watt Gladiator IV

AIR COOLED RECTIFIER SPECIFICATION S-50-A

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

XENON POWER SUPPLY Watt

INSTALLATION, OPERATION & MAINTENANCE SERIES ABC11B-120-XX BATTERY CHARGERS

Electrical Energy and Power Ratings

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

Chargestar P24 / P32 Battery Charger Startmaster P300 Starter / Charger

OPERATING INSTRUCTION

Power System Solutions (PSS)

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

USE AND INSTALLATION HANDBOOK

PF Guard Power Factor Capacitor Bank Installation, Operation, and Maintenance Manual

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

Electronic Ballast EVG 2000-T

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

Operating Instructions Bedienungsanleitung Mode d emploi EWB EWB

LDG6000SA DIESEL GENERATOR OWNERS MANUAL

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

C.E. Niehoff & Co. C653/C653A and C625 Alternators Troubleshooting Guide NOTICE. Hazard Definitions. Battery Charge Volt and Amp Values

Ultra Sine Inverter (US) Generation 4 (G4) User Guide

OWNER S MANUAL Please read this manual before operating your power supply

VOLT POT 1K R220. OPEN FOR 60 Hz STAB A.V.R. R220. Installation and maintenance

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Solstice Electric Fryers SE Series Service Manual

Model 1693, 1694 Switching DC Power Supply

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

SMC BATTERY CHARGER USER S MANUAL SMC USER S MANUAL

Atlas ESR and ESR + Equivalent Series Resistance and Capacitance Meter. Model ESR60/ESR70. Designed and manufactured with pride in the UK.

Yaskawa Electric America Unit Troubleshooting Manual Section One: Introduction & Checks Without Power GPD 506/P5 and GPD 515/G5 (0.

SMT-BM 20 A BMM 05 F BMM 05 AF

Matrix AP 400V 690V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 20 ❷ Startup/Troubleshooting Pages WARNING

AC/DC Converter MBP250-2A13D13M

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

USER MANUAL. 10 January Certification of constancy of performance CNBOP No CPR-0454 Certificate of admittance CNBOP No.

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

User s Manual. Automatic Switch-Mode Battery Charger

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

QSSE, QSSEX INDUSTRIAL Battery Chargers

Manual for Inverter system type PCI05

BellMega BM-510. Operation Manual Ver: 1.0 Rev: 1

DC POWER SUPPLY ALIMENTATION C.C.

XENON POWER SUPPLY Watt

EVS RP6020. Instruction Manual

LS200 Series Instruction Manual

CP Automatic capacitor bank

MODVAR Low voltage reactive power compensation modules Installation manual

THREE PHASE AND SINGLE PHASE ASYNCHRONOUS ELECTRIC MOTORS OPERATION AND MAINTENANCE BOOKLET Rev

Owner s Manual. PowerVerterDC-to-AC Inverter

MODEL ELC-12/60-D BATTERY CHARGER

Innovators in Protection Technology Moulded Case Circuit Breaker Instruction Manual

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

Phoenix Inverter

C.E. Niehoff & Co. C840D Alternator Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

OPERATING INSTRUCTION

MU MMMREV.2 09/01 UNI EN ISO ELECTRONIC POWER FACTOR REGULATOR type QR INSTRUCTION MANUAL PAG. 7

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

ELECTRIC FENCE ENERGIZER SERVICE MANUAL MODEL 950 SERVICE MANUAL FOR OLLI 950 FENCE ENERGIZERS

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

C.E. Niehoff & Co. C703/C703A and C706 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING.

OPERATION INSTRUCTIONS

Assembly instructions

OutdoorXUPS-600AHV-8364

FC/FCA 12, 24, 32 & 48 VOLT, 6 & 10 AMP BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC185N & BC205N OPERATING INSTRUCTIONS

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

MODEL No s: PP3, PP3K

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

DC Master 24/ A

BASIC TROUBLESHOOTING START / STOP PUSHBUTTONS, PILOT LIGHTS, RELAYS, TIMER LIMIT SWITCHES, FLOW SWITCHES, THERMAL SWITCHES, AND OVERLOAD RELAYS.

Transcription:

Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema projection and film handling, with no warranties nor obligations from the authors, for qualified field service engineers. If you are not a qualified technician, please make no adjustments to anything you may read about in these Adobe manual downloads. www.film-tech.com

RECTIFIER POWER SUPPLIES INSTALLATION AND OPERATION MANUAL IREM SpA Sede / Headquarters Via Abegg 75-10050 Borgone (TO) ITALY Tel.++39 011 9646213 - Fax ++39 011 9646385 Sede Legale / Registered Office Via Rocciamelone, 58-10050 S. Antonino (Torino) ITALY Tel. ++39 011 9631313 Fax ++39 011 9649933 UNI EN ISO 9001 UNI EN ISO 14001 Cap. Soc. EUR 1.080.000 int. vers. Registro imprese TO C.F. e P.IVA 00389630013 - VAT No. IT00389630013 E-mail: irem@irem.it - http://www.irem.it

Warning! You should read this manual before attempting any intervention inside the unit. The noncompliance with the instructions given in this manual can lead to serious damage to the unit which in this case will invalidate the warranty. No compensation or indemnity under any kind will be acknowledged for injury or damage due to use or misuse of the product, for poor operation of the appliances connected to IREM product or for immediate or indirect damage caused to the powered equipment. During the warranty period the replacement of defective parts and maintenance procedures will be exclusively carried out at IREM servicing centre. Keep this manual along with the unit. CE declaration is available on request. This manual aims to give some operating instructions to the user in order to grant a safe and optimal use of the unit. Keep this manual along with the unit. You should read it carefully both for installation, starting-up and maintenance procedures. This manual is composed by the following sections:. description (product and application fields). rectifier component layout. connection and operating information (directions for connection, start-up and use). technical characteristics (technical specifications). 2

Table of contents GENERAL PURPOSES Description... 4 Block diagram... 5 Characteristics... 6 RECTIFIER COMPONENT LAYOUT Component layout... 7 CONNECTION AND OPERATING INFORMATION Receiving the unit... 11 Delivery arrangement... 11 Storage... 11 Removing of package and handling... 11 Warnings... 12 Preliminary checks... 12 Installation-use... 13 Terminal board connection... 16 TROUBLESHOOTING Possible failures... 18 Preventive maintenance... 19 Checking and replacing the diodes... 20 TECHNICAL DATA Technical specifications... 22 Power factor correction... 23 Outline drawing... 24 3

General purposes These high quality rectifier power supplies have been expressly designed to ensure the correct operation and long life of short arc Xenon lamps. These units, developed to meet the recommendations of Xenon lamp manufacturers, are fitted with special IREM transformers with adjustable magnetic shunt for continuous output regulation over the entire operating range. The new and peculiar design guarantees a low acoustical noise, i.e. less than 55dB(A). The special design, including an auxiliary filter unit, ensures a low ripple with a negligible starting energy. A 230V AC 2A auxiliary outlet provides power to the igniter when the unit is on. N3 rectifiers are particularly suitable for: - standard film projection - special effects - theatre applications - architectural applications - solar simulations. 4

General purposes Block diagram 1. Main switch for remote control 2. Special transformer with magnetic shunt 3. Diode bridge rectifier 4. Filter and starting peak suppression circuit 5. Auxiliary filter (AFU) (only if present) 6. Voltmeter and ammeter (on request). 5

General purposes Characteristics The N3 series rectifiers have been expressly designed to power Xenon lamps. The rectifier consists in a stray-flux transformer with adjustable magnetic shunt, a rectifying unit mounted on a heatsink and levelling filter. The transformer is formed by three identical single phase transformers "T1, T2, T3" (5) whose primaries are star-connected. The use of three single phase units "T1, T2, T3" (5) permits to get a balanced magnetic circuit such to reduce the ripple of the rectified output current. The magnetic shunt "MS" (16), operated by the hand-wheel "H" (13), permits to adjust the output current according to the lamp manufacturers' specifications, even in case of ± 10% input voltage variations. The transformer secondary windings, provided with central tap, power the diode assembly "D1, D2, D3, D4, D5, D6" (14), centre-tap connected, and protected by "C1, C2, C3, C4, C5, C6" capacitors (15). An electrolytic capacitor "C7" (4) is connected in parallel across the output, working as a filter to reduce the residual ripple down to 8% peak-to-peak. The "A1" ignition relay (3) limits the inrush current to the lamp, caused by the discharge of "C7" capacitor (4), and operates a resistor in series to "C7" at the ignition. The power relay "K1" (6) may be remotely operated by a push button connected to the "X1" remote control terminal board (9). On the "X1" terminal board, there are the "U V W" input terminals (8), "+ and -" output terminals (12), to be connected to the lamp, and the auxiliary terminals "B, H, A" (9), used to operate the power relay coil "K1" (6). On request, these rectifiers can be supplied equipped with voltmeter (21) and ammeter (20). On N3-150, N3-180 and N3-200 models, an additional filter unit (AFU) (19) has been added in order to reduce the output current ripple to a value lower than 3%. On demand, AFU filter unit may be assembled on N3-50, N3-80 and N3-100 models. Rectifier power supply protection and lamp faulty operation warning: These devices, mounted in conjunction with AFU filter, aim at:. warning the user in case of anomalies that, even if not affecting the film projection, could damage the lamp or shorten its useful life (e.g.: a diode failure).. protecting the rectifier against wrong wiring connections during installation. protecting the rectifier against severe line disturbances (up to a possible lack of phase).stopping a possible reignition of the rectifier if the failure has not been correctly detected or repaired. The cabinet, equipped with carrying handles, permits an easy inspection of the inside components. Remark: to reduce the risk of high frequency interference at lamp ignition, two capacitors have been added on the DC output. 6

Component layout N3-50 - N3-80 models 1) Auxiliary autotransformer (T) 12) Output terminals (+, -) (for input voltage exceeding 240Vac) 13) Adjustment hand-wheel 2) ON/OFF switch (S2) 14) Silicon diodes (D1 to D6) 3) Ignition relay (A1) 15) Protection capacitors (C1 to C6) 4) Output filter capacitors (C7-C8) 16) Magnetic shunt (MS) 5) Transformers (T1 to T3) 17) Magnetic shunt adjustment 6) Power relay (K1) 19) Auxiliary filter (AFU -L) (on request) 7) Ground terminal (PE) 20) Ammeter (on request) 8) Input terminals (U, V, W) 21) Voltmeter (on request) 9) Remote control and auxiliary 22) Auxiliary contact (S1)* outlet terminal board 23) Circuit breaker (QF)* 10) Fuse (F1) 24) Alarm ON/OFF terminals (X1)* 11) Fuse (F2) * with AFU only 7

Component layout N3-100 model 1) Auxiliary autotransformer (T) 12) Output terminals (+, -) (for input voltage exceeding 240Vac) 13) Adjustment hand-wheel 2) ON/OFF switch (S2) 14) Silicon diodes (D1 to D6) 3) Ignition relay (A1) 15) Protection capacitors (C1 to C6) 4) Output filter capacitors (C7-C8) 16) Magnetic shunt (MS) 5) Transformers (T1 to T3) 17) Magnetic shunt adjustment 6) Power relay (K1) 19) Auxiliary filter (AFU -L) (on request) 7) Ground terminal (PE) 20) Ammeter (on request) 8) Input terminals (U, V, W) 21) Voltmeter (on request) 9) Remote control and auxiliary 22) Auxiliary contact (S1)* outlet terminal board 23) Circuit breaker (QF)* 10) Fuse (F1) 24) Alarm ON/OFF terminals (X2)* 11) Fuse (F2) * with AFU only 8

Component layout N3-150 - N3-180 models 1) Auxiliary autotransformer (T) 12) Output terminals (+, -) (for input voltage exceeding 240Vac) 13) Adjustment hand-wheel 2) ON/OFF switch (S2) 14) Silicon diodes (D1 to D6) 3) Ignition relay (A1) 15) Protection capacitors (C1 to C6) 4) Output filter capacitors (C7-C8) 16) Magnetic shunt (MS) 5) Transformers (T1 to T3) 17) Magnetic shunt adjustment 6) Power relay (K1) 18) Axial fans (M1-M2) 7) Ground terminal (PE) 19) Auxiliary filter (AFU - L) 8) Input terminals (U, V, W) 20) Ammeter (on request) 9) Remote control and auxiliary 21) Voltmeter (on request) outlet terminal board 22) Auxiliary contact (S1) 10) Fuse (F1) 23) Circuit breaker (QF) 11) Fuse (F2) 24) Alarm ON/OFF terminal (X2) 9

Component layout N3-200 model 1) Auxiliary autotransformer (T) 12) Output terminals (+, -) (for input voltage exceeding 240Vac) 13) Adjustment hand-wheel 2) ON/OFF switch (S2) 14) Silicon diodes (D1 to D6) 3) Ignition relay (A1) 15) Protection capacitors (C1 to C6) 4) Output filter capacitors (C7-C8) 16) Magnetic shunt (MS) 5) Transformers (T1 to T3) 17) Magnetic shunt adjustment 6) Power relay (K1) 18) Axial fans (M1-M2) 7) Ground terminal (PE) 19) Auxiliary filter (AFU - L) 8) Input terminals (U, V, W) 20) Ammeter (on request) 9) Remote control and auxiliary 21) Voltmeter (on request) outlet terminal board 22) Auxiliary contact (S1) 10) Fuse (F1) 23) Circuit breaker (QF) 11) Fuse (F2) 24) Alarm ON/OFF terminal (X2) 10

Connection and operating information Receiving the equipment After receipt, check that the unit is in good condition. When necessary, contact the forwarding agent. Delivery arrangement The supply consists of: N3 rectifier power supply an installation and operation manual a warranty card. Storage If the unit is stored before installation, check that it is kept dry and cannot come into contact with water in any form. Do not expose the unit to the sun rays or other sources of heat. Package removing and handling Remove the packing and keep it in case of future transportation needs. Carefully lift the unit by means of its handles. Avoid any shock when moving. Four plaques with relevant anchoring bolts fix the unit during transportation. To remove the unit from the wooden base, unscrew the bolt screws. 11

Connection and operating information Warnings Caution : dangerous voltage inside the rectifier power supply. Disconnect the unit from the mains before checking the internal components. In case of failed ignition, wait 3 minutes at least for capacitor discharge. Prevent water, liquids in general and/or foreign objects from getting inside the appliance (do not open the unit, contact IREM servicing centre!). Check that a 100 mm (4 inch.) free space is left all around the unit to ensure the necessary ventilation and to prevent overheating. To prevent blockages caused by overheating, do not expose the unit to the sun rays or other sources of heat. Do not place anything on the upper side of the unit and ensure that the ventilation slots are unobstructed. Installation must only be carried out by trained personnel. Preliminary checks The connection must be carried out in compliance with the current safety standards. To ensure a correct operation of the unit, please strictly follow these recommendations: - the input powering has to be three phase and ground, withstanding current values as per unit dataplate - the earth of the installation and the protections against indirect contacts must comply with current safety standards. 12

Connection and operating information Installation - use Connect the input and output lines to the "X1" terminal board, input terminals "U V W" (8), output terminals "+ and -" (12), by means of wires having a proper section (max. current density: 4A per sq/mm) and the ground wire to "PE" terminal (7). If the remote operation is required, connect the wires of the ON-OFF push button (see relevant wiring diagram) to the terminals marked "B, H, A" located on the terminal board (9). On the same terminal board (9) and on the terminal (D) with fuse F1 (10), there is also a 230V 2A outlet to power the igniter. After connecting the unit, switch on the rectifier by means of the ON-OFF switch (2) or the remote control, if installed. When the lamp is on, adjust the current by means of the adjustment hand-wheel (13). On units equipped with meters, you can read the current value on the ammeter (20) and the voltage on the voltmeter (21). N3-50 and N3-80 without AFU 13

Connection and operating information Installation - use N3-50 and N3-80 equipped with AFU Check that the circuit breaker (23) protecting the ignition relay board is set to ON. If the circuit breaker is set to OFF, move to ON. The circuit breaker tripping is remotely signalled through two contacts (22) connected to the alarm ON terminals (X1-24). When the unit is properly operated and the circuit breaker (23) is set to ON the status of the contacts is: contact on terminals F-G: open contact on terminals I-L: closed If the circuit breaker trips, the status of the contacts is: contact on terminals F-G: closed contact on terminals I-L: open 14

Connection and operating information Installation - use N3-100*, N3-150, N3-180, N3-200 equipped with AFU Check that the circuit breaker (23) protecting the ignition relay board is set to ON. If the circuit breaker is set to OFF, move to ON. The circuit breaker tripping is remotely signalled through one contact (22) connected to the alarm ON terminals (X2-24). When the unit is properly operated and the circuit breaker (23) is set to ON the status of the contact is: contact on terminals 21-22: open If the circuit breaker trips, the status of the contact is: contact on terminals 21-22: closed. * AFU on demand. 15

Connection and operating information Terminal board connection Take off the terminal cover by unscrewing the two fixing screws (see picture no. 1) fixing screws PICT. NO. 1 Take off the chocks (see pict. no. 2) PICT. NO.2 16

Connection and operating information Terminal board connection Arrange the chocks and fix them to the leads before performing the connection (see pict. no. 3) PICT. NO.3 Connect the cables to the terminal board and take in place the chocks (see pict. no. 4) PICT. NO.4 PICT. NO.5 17

Troubleshooting Possible failures Caution : dangerous voltage inside the rectifier power supply. Disconnect the unit from the mains before checking the internal components. Then wait 3 minutes at least for capacitor discharge. A. Operating the ON/OFF switch, the rectifier is not powered: 1) check the connection; 2) check that the powering voltage is the proper one and that no phase is lacking; 3) check the efficiency of K1 power relay; if damaged, replace it. B. Operating the ON/OFF switch, the line protections blow: 1) check that there is no short circuit on the rectifier and, in particular, on the diodes "D1...D6", on the protection capacitors "C1...C6" of the rectifying heatsink and on "C7 or C8" capacitors. C. The lamp does not ignite: 1) the lamp is damaged, replace it; 2) there is no high voltage discharge into the lamp: check the proper operation of the igniter and verify that there is no discharge towards earth inside the lamphouse. 3) if igniter and lamp are not damaged, check the efficiency of the rectifier: the noload voltage must be 88V-130V approx. If the no-load voltage is low: - check that the powering voltage is the proper one and that no phase is lacking; - check the efficiency of the diodes; if some of them are damaged, replace them. 4) be sure QF circuit breaker is set to ON (closed). D. The output current has a too high ripple: 1) check that no phase is lacking; 2) check the efficiency of the diodes; should they be damaged, replace them; 3) check the efficiency of "C7 or C8" capacitors: if damaged, replace them; 4) check the efficiency of "A1" ignition relay : if damaged, replace it. 5) be sure QF circuit breaker is set to ON (closed). 18

Troubleshooting E. QF circuit breaker (protecting A1 board) trips. S1 contact closes down to warn the user. Check: 1) the presence of all the three input phases (U, V, W). Check the powering line upstream the rectifier and reset the lacking phase. Set QF circuit breaker to ON. 2) the efficiency of the diodes (the diodes could be short circuited or interrupted). When necessary, replace the faulty diode (see relevant instructions on this manual). Set QF circuit breaker to ON. 3) the efficiency of C7 and C8 capacitors. The capacitors could be short circuited (low Ohmic resistance between the terminals). When necessary, replace the faulty capacitor. Set QF circuit breaker to ON. 4) the continuity of K1 power relay contacts. If there is no continuity, replace K1. 5) the absence of overheating on the wiring joints to: primary and secondary coils, diodes, heat sinks and AFU filter. When necessary, reset the fault wiring joints. Set QF circuit breaker to ON. Preventive maintenance Some components must be periodically replaced. This is due to their particular constructive featuring (like ageing). So, schedule a preventive maintenance and/or replacement of components listed below: - electrolytic capacitors (C7-C8): schedule a replacement every 5 years - D1 to D6 diodes: replace every 10 years. Important note: diode lockage must be performed by means of a dynamometric wrench (torque wrench setting: 2.5N.m [22lb-in]). - K1 power relay: replace every 10 years - M1-M2 fans: dust and waste have to be removed once a year. Replace fans every 10 years. 19

Troubleshooting Checking and replacing the diodes The 6 diodes (in groups of 3) are mounted onto the two heat sinks placed on the side. Replace the damaged diodes as per picture and instructions below. 1) Take off the M6 retaining nut (6) and the washer (7) by means of an hexagon wrench (10 mm/13/32"). Pull out the flexible end (tail) (8) from the screw terminal. 2) Set the multimeter (DVM) reading to the diode symbol. 20

Troubleshooting 3) Connect the red probe to one of the two heat sinks. Remark: usually, the red probe is the positive pole of the DVM battery, whilst the black one is the negative. The test diagram is shown below. If the diode is OK, the reading range should be within 0.4 and 0.6 Ω. Reversing the probes will result in an infinite reading (out of scale). If the diode is interrupted, the measurement will result in an infinite reading (out of scale). If the diode is shorted (most common case) the DVM reads a value close to 0 Ω, even reversing the probes. If the probes of DVM battery have reverse poles, the measurement will result in infinite reading. The reverse polarity has no effect on interrupted or shorted diodes. 4) The damaged diode should be then replaced as follows: 1. lock the case (1) by means of an hexagonal wrench (17 mm type) 2. by means of an hexagonal wrench (11 mm type ) completely rotate counterclockwise the retaining nut (4) and the washer (3). Diode mounting directions a) spread some silicone compound onto the flat surface of the diode (2) (e.g.: Wacker silicone P12). b) insert the diode into the fixing hole. Lock the case (1) by means of a hexagonal wrench (17 mm type). Insert the spring washer (3) into the threaded tang and then rotate clockwise the retaining nut (4) by means of a dynamometric wrench (11 mm - 1/4") (wrenching torque: 3N M (26.8 lbf.in). c) insert the diode end terminal (tail) (8) into the M6 retaining nut, and fix it by means of the washer (7) and the M6 nut (6). f) clamp the M6 nut (6) (dynamometric wrench: 10 mm - 13/32") (wrenching torque: 5N M (45 lbf.in). 21

Technical specifications Model DC output V A Three phase input voltage (V) No-load voltage (V) Max. drained power (kva) Drained current (A) Current ripple (%) Efficiency Cooling N3-50 16 28 30 55 208-230V - 60Hz 220V - 50Hz 400V - 50Hz 415V - 50Hz 88 88 92 92 3 7.9 7.9 4.3 4.2 <8 >0.8 free convection N3-80 21 35 43 85 208-230V - 60Hz 220V - 50Hz 400V - 50Hz 415V - 50Hz 116 116 118 118 5.8 15.2 15.2 8.4 8 <8 >0.8 free convection N3-100 23 36 52 110 208-230V - 60Hz 220V - 50Hz 400V - 50Hz 415V - 50Hz 116 116 120 120 6.9 18 18 10 9.6 <8 >0.8 free convection N3-150 28 40 80 150 208-230V - 60Hz 220V - 50Hz 400V - 50Hz 415V - 50Hz 116 116 120 116 9.4 24.7 24.7 13.6 13 <3 >0.8 forced ventilation N3-180 28 48 110 165 208-230V - 60Hz 220V - 50Hz 400V - 50Hz 415V - 50Hz 128 128 128 128 13 34 34 18.8 18.1 <3 >0.8 forced ventilation N3-200 36 55 110 210 208-230V - 60Hz 220V - 50Hz 400V - 50Hz 415V - 50Hz 168 168 168 168 18 48 48 26 25 <3 >0.8 forced ventilation Marking: CE, UL (for US market) Operating temperature: 0 C to 40 C Storage temperature: -20 C to +60 C Degree of protection: IP20 22

Power factor correction Rectifier model Input voltage (V) Reactive power (VAr) Capacitor bank (µf) N3-50 400-415 208-230 - 60Hz 230-50Hz 2000 1800 3x15 3x35 3x40 N3-80 400-415 208-230 - 60Hz 230-50Hz 3000 2800 3x20 3x50 3x60 N3-100 400-415 208-230 - 60Hz 230-50Hz 4500 4300 3x30 3x80 3x100 N3-150 400-415 208-230 - 60Hz 230-50Hz 7500 7300 3x50 3x130 3x60 N3-180 400-415 208-230 - 60Hz 230-50Hz 8750 8500 3x60 3x155 3x190 N3-200 400-415 208-230V 60Hz 230V 50Hz 12000 11500 3x80 3x210 3x250 Capacitors are delta connected. They must be rated for the nominal voltage of the rectifier plus 10% at least. Capacitors have to be connected to the input terminals (U V W). For connection please refer to current safety standards. 23

Outline drawing Model Dimensions (mm) (A x B x H) Weight (kg) N3-50 N3-80 N3-100 N3-150 N3-180 N3-200 410x350x840 410x350x840 460x410x940 460x410x940 460x410x940 460x410x1040 84 101 127 154 175 207 24