Concealite Life Safety Products Model: F5000 Series. Save These Instructions. Read and Follow All Safety Instructions

Similar documents
Concealite Life Safety Products Model: R4000 Series (120/277 VAC Powered R4000 Remote Fixtures) Save These Instructions

Installation Instructions Central Battery Units

Self-Testing Industrial Series

Spectron Industrial Series

MIRRORLITE RECESSED EMERGENCY LIGHTING

IMPORTANT SAFEGUARDS

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS FOR NEW YORK 18 WATT SERIES

DeSoto EMERGENCY LIGHTING UNIT. U.S. Versions: 12V- DM (P2 & P3) / DM / DM INSTALLATION INSTRUCTIONS

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

GUARD-LITE SERIES EMERGENCY UNIT EQUIPMENT

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE LMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation Instructions & Users Manual IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Installation Instructions and User Manual For. 100 Watt Inverter Power System

EMIU 720W Mini Inverter

INSTRUCTION MANUAL IMPORTANT SAFEGUARDS. When using electrical equipment, basic safety precautions should always be followed, including the following:

CODE MANDATED INTERIOR EMERGENCY LIGHTING:

STEP-BY-STEP INSTALLATION GUIDE

Installation And Operation Instructions

KT-EMRG-1400-SL /B. 3. Please ensure the electricity connections conform to the National Electrical Code and local regulations if applicable.

Sure-Lites. Installation Instructions for the Sure-Lites UX Self Powered Exit Sign with Self Diagnostics. IB505037EN Important Safeguards

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

Installation And Operation Instructions

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS. SAVE THESE INSTRUCTIONS!

Prestige Series Edge-Lit LED Sign IMPORTANT SAFEGUARDS READ AND FOLLOW ALL SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

The Da-Lite Difference.

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

BALT5-800 LOW-PROFILE FLUORESCENT EMERGENCY BALLAST

DeSoto NEMA 4X EMERGENCY LIGHTING UNIT. U.S. Versions: 6V- DM90X618 / DM90X654 12V- DM90X1254 / DM90X12100 INSTALLATION INSTRUCTIONS

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Installation and Operation Instructions 10/04/13

EXP-EMG-2L-LE6. Explosion Proof Bug Eye Emergency LED Fixture Instruction Manual

INSTRUCTION MANUAL. IMPORTANT SAFEGUARDS When using electrical equipment, basic safety precautions should always be followed, including the following:

Installation And Operation Instructions For FHSCP-UNV Series Emergency LED Drivers Models: FHSCP-UNV-5WL, 7.8WL, 10.7WL, 13.

SURE-LITES FBP140XLP Instruction Manual

SAVE THESE INSTRUCTIONS

Installation And Operation Instructions

Deep Cycle Battery Safety. First. Battery Handling, Maintenance & Test Procedures

Installation Instruction

2603 Battery Pal 3 AMP, 1 2 VOLT BATTERY CHARGER

Cruising Charger Series OWNER S MANUAL

SAVE THESE INSTRUCTIONS

RUFNEX Series Low Profile Wrenches Operation and Maintenance Manual

Low Profile Wrenches Operation and Maintenance Manual

INSTRUCTION MANUAL. 12-Station HD Shop 12V Portable Battery Charger

Nova UAC (NV-UAC-M) Modified Sine Wave 650W 800W 1000W

MaxLite LED UTILITY WRAP FIXTURES

HexPro Series Low Profile Wrenches

SP6. Automatic Battery Charger. Model

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

BoostPak2 Instruction Manual

Deltran Battery Tender 6V/12V 4Amp 5 & 10 Bank Battery Management System TABLE 1. Length of Cord, Feet AWG Size of Cord

INSTRUCTION BOOK FOR. Dual Masking Electrol

IBT Series Square Drive Torque Wrenches

Lumencia. LLMPS SERIES Micro Power Systems. Multi-Unit Residential Lighting. Job Name: Type:

BRAVO Inverter/Battery Charger. Table of Contents

Installation and Operation Instructions SERVICE BY QUALIFIED PERSONNEL ONLY


Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Model: PSC AP

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

Safety, Installation And Operating Instructions For The Following Battery Charger Models: i2412, i3612, i4809, i2425, i3625, and i4818

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

INSTRUCTION BOOK FOR. Cosmopolitan Electrol For Sizes Up To 9' x 12'

10 AMP ON BOARD BATTERY CHARGER


model ps600 Address all communications and shipments to: FEDERAL SIGNAL CORPORATION

POWER TILT ACCESSORY FUZE T50 STELLAR GL STELLAR LEAP OWNER S OPERATION AND MAINTENANCE MANUAL

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

MODEL ELC-12/40-CVM-D BATTERY CHARGER

DURABLE DEPENDABLE PROVEN. IOTA Engineering tel:

Installation Instructions and User Manual For

Installation and Operating Instructions (for chargers shown below)

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

The Da-Lite Difference.

PowerLevel s e r i e s

Sure-Lites LPXC SERIES. Input Voltage Input Power 19 3/4" " /8" /8" 54 13" /2" 191

600 Amp Battery Jumper with Air Compressor

The Da-Lite Difference.

EMERGENCY ONE-LED TM SOLO TM NON MAINTAINED LED LAMP AND DRIVER KIT

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

Sentry Battery Charger. Installation and Operations Manual Section 75

LC BATTERY CHARGER OPERATION & MAINTENANCE GUIDE

OutdoorXUPS-600AHV-8364

Powerware Vdc Extended Battery Cabinet User s Guide.

24 VOLT AUTOMATIC BATTERY CHARGER PART NO

FLUORESCENT EMERGENCY BALLAST Lumens. When using this lighting device safety precautions should be followed at all times

TANK MONITOR SYSTEMS DTM04 TANK MONITOR DTM08 TANK MONITOR DTM12 TANK MONITOR INSTALLATION AND OPERATION MANUAL

EEQ SERIES COMPACT FLUORESCENT EMERGENCY FACTORY SEALED LIGHTING FIXTURES

MODEL ELC-12/60-D BATTERY CHARGER

Models: SP3, SPSS3 Automatic Battery Charger

OWNER'S MANUAL POWER BOOSTER. Rechargeable 12 Volt DC power supply. Item # Enclose copy of original sales receipt

Model: SE-4020-CA Automatic Battery Charger

OPERATION AND MAINTENANCE MANUAL

Operator s Manual Version 1.21 TR-200. Peristaltic Pump. Durham Geo Slope Indicator 2175 West Park Court Stone Mountain, GA USA

CRS1, CRS2 and CRS3. For additional information please call our. PRO CHARGING SYSTEMS, LLC 1551 Heil Quaker Boulevard, LaVergne, TN

Transcription:

1. Do not use outdoors. Concealite Life Safety Products Model: F5000 Series (Standard, SD & RT) Save These Instructions Important Safeguards When using electrical equipment, basic safety precautions should always be followed: Read and Follow All Safety Instructions 2. Do not let power cords touch hot surfaces. Do not mount units where they will be exposed to direct sunlight, radiators, gas or electric heaters. Prolonged exposure to temperatures exceeding 95 degrees Fahrenheit may reduce battery life and void warranty. 3. Failure to fully charge the batteries within 120 days from receipt will void the warranty on the batteries 4. Use caution when servicing batteries. Battery acid causes burns to skin and eyes. If acid is spilled on skin or in eye, flush with fresh water and contact a physician immediately. 5. Equipment should be mounted in locations and at heights where it will not readily be subjected to tampering by unauthorized personnel. 6. CAUTION: Halogen or LED lamps are used in this equipment. To avoid shattering, do not operate lamp in excess of rated voltage, protect lamp against abrasion, scratches and liquids when lamp is operating. Dispose of lamp with care. 7. Halogen or LED lamps operate at high temperatures. Do not store or place flammable materials near lamps. 8. The use of accessory equipment not recommended by the manufacturer may cause an unsafe condition, and void all warranties. 9. Do not use this equipment for other than intended use. 10. Qualifed service personnel should perform servicing of this equipment. Model: F5000 Series AC Supply Voltage: 120/277 Volts (+/- 10%) Power Consumption: Battery Type: Maximum 23 Watts Sealed Maintenance Free Storage Battery Battery Float Voltage: See Unit Model Label Discharge Duty Cycle: 90 Minutes - Example: F5-20-90 1.5 Hours of illumination to 87.5% of battery voltage. 2 Hours - Example: F5-20-2 2 Hours of illumination to 87.5% of battery voltage 4 Hours - Example: F5-35-4 4 Hours of illumination to 87.5% of battery voltage Recharge Duty Cycle: Charger Type: Transfer Means: Status Indication: Test Means: Lighting Head 48 Hours for full charge from 87.5% battery voltage. Continuous automatic float-charge after full charge is restored. Solid state full wave silicone diode rectifcation, integrated circuit voltage regulation. Transfer circuit energizes lamps on loss of AC. Pilot light shows AC is available and charger is in operation. Pushbutton switch simulates AC failure to test transfer function, battery and lamp readiness and charger response to battery discharge. 345 degrees universal swivel rotation. 180 degree tilt position adjustment. Concealite Life Safety Products Phone: 605-542-4444 202 Elk Street - PO Box 160 Fax: 605-542-3333 Elkton, SD 57026 Website: www.concealite.com TROUBLE SHOOTING QUESTIONS? Go to - http://www.concealite.com/contact.html

Instructions for Installation Operation Service Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. This unit is designed for recessed mounting in gypsum board or plaster wall or ceiling. (Surface mounted is designated with suffix SM). Locate unit within area to best maximize lighted area under anticipated conditions. FMS (Frameless Mounting System option) STOP RIGHT HERE AND REVIEW FMS INSTUCTIONS! Step #1: Backbox Installation The recessed backbox is standard. If your installation requires the Surface Mount or Retrofit Backbox, please refer to the separate instructions for backbox installation. Backbox is designed for recessed mounting in gypsum board or plaster wall or ceiling. The mounting contact area of the wall or ceiling must be straight, without deformity. When used in plaster wall or ceiling, install plaster trim option. (See plaster trim instructions). PLASTER TRIM IS USED ONLY ON PLASTER. NOT NEEDED FOR SHEETROCK INSTALLATION. 1. Securely fasten back box to stud, joist or blocking material using tabs at top and bottom of backbox with screws (not furnished). ChargerBoard Secton 2. For Wall Mounting Mount with knockouts at top end. 3. For Ceiling Mounting Mount with opening of backbox downwards. When mounting in grid ceiling see T-Bar installation instructions. 4. Route branch circuiting in metallic raceway. Securely terminate into enclosure by KO s provided. 5. Install tinnerman clips over oblong holes in sides of backbox. 6. Install gypsum board or plaster wall or ceiling material. 7. Provide a 6.75 wide by 7.25 opening in wall or ceiling material to accept fixture head assembly. Dimension matches opening area of back box enclosure. Attach Tinnerman ClipHere Fixture Head Secton Battery Section (length will vary) Minimum 5/8" wall or ceiling material required for flush mounting Plaster Trim Mounting Detail Total Depth of 4.1/8" required for flush mounting Note: Plaster trim is only needed for actual plaster material installation. Back Box Side View Provide 6.75 wide by 7.25 high area opening in wall or ceiling material to accept fixture head assembly. Dimension matches opening area of back box enclosure. 6.75"wide by 7.25"high fixture head opening Backbox Interior Back Box Front View Slide plaster trim into back box opening

Instructions for Installation Operation Service Failure to follow published installation instructions or any modifications to the product may damage the unit and will void the warranty. Step #2: Branch Circuit Installation Determine the fixture type (Standard, SD or RT) Verify primary input voltage as either 120VAC or 277VAC. NOTE: The BLACK and ORANGE wires are NEVER used together in the same application. Always cap the unused wire. Provide each unit with a single unswitched supply from (normal power) 120 VAC/277 VAC branch circuit used for normal lighting in the area to be illuminated. The wiring should be a permanent installation using metal enclosed wiring raceway. A 13/16 diameter knockout is provided on the top of the recessed or retrofit backbox. If unit is a Remote Test (RT) version, review voltage drop table to determine appropriate wire gauge requirements for the distance between switch plate and fixture. Run wires from Remote Test Switch Plate through the top of the back box and make connections to the corresponding wires on the charger board cradle. Each Remote Test Switch will control only one emergency lighting unit. Note: remote test switch is a normally closed switch if you have an erratic connection the fixture will not CHARGE. Verify all connections. 4 Pin Connector to fixture head (SD Option) Charger Board Cradle 4 Pin Connector to fixture head (All versions) 2 Pin Connector to battery Pack Primary Input Wires White-Common Black-Primary120vAC Orange-Primary277vAC NOTE: The Black & Orange wires are NEVER used together in the same application Always cap the unused wire RT Charger Board Cradle (To RemoteTest Switch Plate) Charge LED PTT Switch 4 Pin Connector to fixture head (All versions) 2Pin Connector to battery Pack Primary Input Wires White-Common Black-Primary120vAC Orange-Primary277vAC NOTE: The Black & Orange wires are NEVER used together in the same application Always cap the unused wire Each Remote Test Switch will only control one emergency lighting unit

Verify Primary input voltage prior to termination Step #3: Charger Board Installation Carefully slide charger board into the top of the backbox. Provide Grounding RTWires (if applicable) NOTE: The Black & Orange wires are NEVER used together in the same application. Always cap the unused wire. Primary Input Wires White-Common Black-Primary120vAC Orange-Primary277vAC Place tab in backbox lance. Step #4: Battery Installation Slide the battery pack into the bottom of the back box enclosure. ALWAYS USE HANDLE ON BATTERY BACKING to move & install battery pack. On a multiple battery pack, with the sheeting toward you grip the handhold and flex sheeting outward to assist in placing the battery pack into the back box enclosure. Connect the 2-pin connector (labeled battery) from the charger board to the battery pack. To SD Option (if applicable) Charger Board Cradle Carefully place charger board cradle in back box. Make primary AC connections & RT connections, if applicable Push charger cradle into positionand and place lance in tab. To Battery Pack To Fixture Head Battery leads from charger cradle Insert battery pack into bottom of back box. Connect 2 pin connector (labeled battery) from charger cradle to battery pack Battery Pack(s) Leads from battery to charger cradle Connect 4 pin Fixture Head connector to charger board connector (labeled Fixture Head) Step #5: Fixture Head Installation Connect the 4-pin Molex connector from the charger board to the connector on the Fixture Head. Slide Fixture Head onto the two(2) #10-24x3/8"bolts installed on the back box enclosure. Fixture Head Assembly Push to Test AC On Integral LED Pilot Light IntegralTest Switch (Use a STRAIGHTENED paper clip or stylus to test). Step #6: Fixture Head Mounting Screw the socket head bolts partially into the tinnerman clip on the side of the backbox. Slide fixture head onto the heads of the two socket head bolts until flush with wall or ceiling surface. With the door in a half open position; securely tighten the socket head bolts evenly to each side of the backbox with the allen wrench provided. Step #8: Energize primary branch circuit. Step #7: Lamp Installation Insert the locking bi-pin lamps by inserting the lamp into the lamp socket and rotate clockwise until locks in place. Verify Lamps are properly turned into sockets. Step #9: Allow the fixture to charge for a minimum of 48 hours (longer for multiple battery packs) prior to testing. Verify that the branch circuit supply to the fixture is not interrupted.

Troubleshooting Symptom Unit does not operate when power is lost, or test switch is depressed Unit only operates for a short period Of time Lamp(s) does not energize when in Emergency mode, but door rotates open Possible Corrective Measure(s) Verify AC power is energized to the unit. Verify the battery is properly connected Verify the battery level is at or above 13.8 VDC Verify the unit has charged for 48 hours Allow the unit to fully charge to a nominal battery level of 13.8 VDC, then retest. Charge for 48 hours Remove lamp(s) and check lamp with resistance meter to verify condition. Resistance indicated good lamp. Open (no) resistance indicates bad lamp, replace lamp & retest. Routine Care The batteries used in this model are sealed and require no maintenance, but will benefit from certain procedures. During routine standby operation, charger output fluctuates only slightly in floating the battery at its full-charge voltage. But after an AC failure and subsequent battery discharge, charger output increases greatly to recharge the battery as quickly as cell temperature rise and gas cycling considerations permit. This vigorous charging action also agitates the electrolyte and tends to reverse physical and chemical changes that can slowly occur in a battery that stands for a long period without cycling. It follows that if power failures are infrequent, occasional deliberate cycling may extend battery life. Test Cycling Every month, if there has been no power failure, press the unit test switch for 15 seconds. Once the switch is released, the battery will recharge to full charge condition. Conditioning Cycles Once a year, if power failures have been infrequent or non-existent, perform a full battery conditioning cycle. De-energize the AC circuit to which the unit is connected and let the emergency lights operate for the period of operation for which the unit is listed. Then restore AC power. This puts the battery through a discharge/recharge cycle over its full-intended range, and provides a rigorous test of over-all unit operation. Taking a Unit Out of Service If a unit is to be deliberately taken out of service for an extended period, the battery lead should be disconnected from the charger so that the battery will go into storage in a fully charged condition. Warranty All Concealite fixtures are tested and are guaranteed to be free from defective materials and workmanship for a period of three years from date of shipment under normal operations and proper use. Correction of all defects shall be by replacement or repair (at our option) and shall constitute fulfillment of all manufacturer s obligations. We will not allow any charge for labor, materials, etc that does not have our written approval before the work is begun. Damage incurred in handling or in transit are not covered by this guarantee. Any other warranty, expressed or implied, is hereby void. Modifications to the product or failure to follow installation instructions will void the warranty. Batteries provided as part of this unit s equipment carry a three-year warranty. Failure to fully charge the batteries within 120 days from receipt will void the warranty on the batteries. On Site Painting Instructions 1. The door and frame of the unit have been factory painted with a powder-coated paint with a hard f nish. This finish should be roughened with a coarse steel wool or sandpaper before a new finsh is applied to ensure the paint adheres to the factory finish. 2. When the new finish is applied, extreme care should be taken that a seal is not formed between the door and the frame, which would prevent the door from opening. Also, assure that the paint is not so heavy that it runs into the gearing mechanism. This damage will void the warranty on the unit. 3. If the finish is sprayed on, we suggest that a thin cardboard or plastic strip be inserted between the door and the frame to prevent a paint seal from being formed. 4. After the new finish is applied, a sharp edge such as a single edge razor or utility knife may be inserted in the opening between the door and frame and run around the circumference of the unit to ensure that no seal has been formed. The finish should be completely dry before this step is performed. 5. If the unit is being covered with material (wallpaper, cloth, laminate, etc.), allow the mastic used to apply the covering to completely set up. Use a sharp edge such as single edge razor or a utility knife held at a 20 to 30 degree angle against the frame and run the blade around the frame. Repeat this procedure holding the edge against the door. This will provide a beveled edge that will prevent the material from fraying as the unit operates. Assure that the mastic adhesive does not run or be allowed to coat between door and frame. This will void warranty.

Self Diagnostic Option Features The SD (Self-Diagnostic) option makes routine maintenance as effortless as looking at the diagnostic panel. The SD option automatically provides battery exercise and extended testing. The LED panel indicates specif c component status. The self-diagnostic option provides the following features: Monthly battery exercise Battery monitoring Charger monitoring Replacement battery indication LED lamp status The SD self-diagnostic option allows maintenance personnel to monitor system status at a glance. This SD option automatically cycles the unit every 24-30 days. While it is cycling, the monitoring circuits check the battery to ensure that it will deliver the power needed to maintain the load for a 1Z/x hours. The SD option does not use the lamps to test the battery; rather there is a predetermined resistive load within the option, thus avoiding lamp life reduction. The SD option also recognizes problems while the unit is in a standby mode. During this period, the monitoring circuits check the charger voltage to see if an overcharge or undercharge is occurring. If either an overcharge or undercharge exists, the fault indicator will illuminate. The yellow LED indicates cycling and will only illuminate if the unit is self-testing. The LED stays lit for the duration of the test cycle, normally 15-20 minutes. The red LED indicates a fault condition. The LED will come on and flash when a fault condition exists. The unit does not have to go through a cycle test to indicate a fault. The circuits are monitoring the charger at all times. The green LED indicates charge and utility power. This LED is on during the standby mode. The test switch is used to test the unit at any time. When a fault condition occurs, the indicator will flash. Once the problem is corrected, the test switch is used to reset the SD circuit.

Concealite Self-Diagnostic (SD) System Operation and Troubleshooting Guide The Self Diagnostic (SD) system automatically monitors both battery performance and electronic functions of an emergency lighting unit. Not using the emergency lights during this test greatly improves lamp life, thus increasing the possibility of proper lamp operation. 1. SD System Operation (Refer to Chart 1 for LED Description) a) Upon initial power up, the SD system will indicate a bad or unconnected battery termination. A flashing fault LED will remind the installer to connect the battery. b) During normal operation of the emergency lighting unit, the SD system will monitor the battery charger for proper operation. An over or under charge will be indicated by a flashing fault LED. c) The SD system automatically exercises the battery every 24-30 days. This test is indicated by having the RX Mode LED on. A ten minute discharge is performed by using a Dummy Load. This exercise assures that the battery is performing properly. A fault LED will indicate if a battery is weak or dead. 2. Trouble Shooting Aid. The following is a guide to determine the cause of a flashing fault LED. The steps must be followed in sequence to properly determine cause. Note: After each step, depress the test switch for approximately two seconds to reset the SD system. If fault LED stays off the problem has been corrected. If not, proceed to the next step. a) Make sure battery connections are connected and free of corrosion; clean terminal if necessary. b) Measure battery voltage. It should be within the following limits: Battery Volts 12V Low 9.60+/-.10 High 14.40 +/-.10 If not within the limits. a) Make sure that the charge LED is on. If not, make sure that power is available to the unit. b) If the battery voltage is low and charge LED is on, replace the charger board. c) If the battery voltage is high, consult factory to determine if charger is out of tolerance or charger board is defective. Reset SD system before performing this test. Fault LED must be off. Discharge unit between ten to ninety minutes by removing AC input. If during this test the fault LED flashes, the battery is weak. Replace battery and repeat test. Chart 1 Yellow LED SD Mode Steady on when self-testing Red LED Fault Flashing when fault is determined Green LED Charge ON when charger is charging Test Switch To test & reset SD Board F5 & R4 12 VOLT MR 16 Maximum Mounting Height Watts 12W 13' 20W 15' 35W 32' 50W 49' 75W 50' 3W 30 DEGREE GU10 (14.25 VOLT) 32' 3W 45 DEGREE GU10 (14.25 VOLT) 23' Height