COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Similar documents
Effective November 2016 Supersedes September 1998 (S )

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

COOPER POWER SERIES. Current-Limiting Type NXC (C-Rated) Fuse Installation Instructions. Fusing Equipment MN132014EN

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

Effective June 2016 New Issue

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

COOPER POWER SERIES. RTE EL-BAY-O-NET FUSE Re-Fusing Instructions. Fusing Equipment MN132024EN

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Effective March 2015 Supersedes S August 2012

Effective November 2016 Supersedes February 2012 (S )

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

COOPER POWER SERIES. Dielectric grease application to recloser cable instructions. Reclosers MN280070EN

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. Pad-mounted Switchgear MN285019EN. Effective March 2017 Supersedes February 2007 (S )

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

High-voltage primary bushings installation instructions

COOPER POWER SERIES. Expulsion fuse installation instructions. Capacitors MN230005EN. Effective November 2016 Supersedes November 2001 (S )

COOPER POWER SERIES. KA662R tank-lifting windlass assembly and installation instructions. Recloser Mountings MN280071EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Type NR oil switch installation and operation instructions

COOPER POWER SERIES. Surge arrester interchangeable fuse cutout combination installation instructions. Surge Arresters MN235004EN

COOPER POWER SERIES. Types 4H single-phase and 6H three-phase vacuum interrupter conversion kits. Reclosers MN280014EN

COOPER POWER SERIES. KA716L7001 adjustable control valve kit for Types L, E, 4E, V4E, and V4L reclosers installation and adjustment instructions

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

Effective May 2017 Supersedes December 2004 (S )

COOPER POWER SERIES. Quick Connect Assembly (QCA) Retrofit Kit, General Electric Installation Instructions. Voltage Regulators MN225075EN

COOPER POWER SERIES. Mercury switch to microswitch retrofit kit KA349WE installation instructions. Reclosers MN280022EN

Effective May 2017 Supersedes January 2003 (S )

S Voltage Regulators GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage. Standards

COOPER POWER SERIES. KA146W5 single pole-mounting hanger; KA146W2 tank lifting windlass assembly and installation instructions. Reclosers MN280039EN

COOPER POWER SERIES. Fused loadbreak elbow connector installation instructions. Loadbreak Apparatus Connectors MN650014EN

COOPER POWER SERIES. 600 A 15 kv and 25 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650004EN

COOPER POWER SERIES. 600 A 15/25 kv class BOL-T and separable splice connector assembly installation instructions

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. Manually-Operated M-Force Switch Installation and Operation Instructions. Switches and Disconnects MN008003EN

COOPER POWER SERIES. Types D and DV recloser installation instructions. Reclosers MN280030EN

COOPER POWER SERIES. 600 A 35 kv class BT-TAP connector system installation instructions. Deadbreak Apparatus Connectors MN650003EN

Figure 1. Kearney Type HX cutout.

COOPER POWER SERIES. Metal-enclosed capacitor banks installation instructions. Power Capacitors MN230010EN

Factory Authorized Mechanism Enhancement (FAME)

COOPER POWER SERIES. Instructions for oil-filled, single-phase overhead distribution transformers. Distribution Transformers MN201003EN

COOPER POWER SERIES. Metal-enclosed, pad-mounted capacitor banks installation instructions. Power Capacitors MN230009EN

S Voltage Regulators GENERAL. PRODUCT INFORMATION Introduction. Contents. Acceptance and Initial Inspection. Handling and Storage.

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage.

Removal/installation instructions for Series NRX (IZMX) drawout levering (racking) mechanism

Installation Instructions for Interlocking Trip Indicator with Remote Reset for Magnum Low Voltage Circuit Breakers

S Voltage Regulators PRODUCT INFORMATION GENERAL. Contents. Acceptance and Initial Inspection. Handling and Storage

Reprogramming guide. Power Defense ICCB. Instructional Leaflet IL EN WARNING WARNING. Instructions apply to:

3-way multi-family drawout cable interlock kit - type 32 - RF

This Kit Is for Use with Types RE, RVE, WE, WVE, VWE, VWVE27, and VWVE38 Reclosers.

Installation and removal instructions for Series NRX RF fixed breaker three-way Type 32 cable interlock kit

Two-way cable interlock kit for Magnum drawout circuit breakers

Two-way cable interlock kit for Magnum fixed circuit breakers

Installation and Operation

SIEMENS. XJ-L Busway Systems. Storage, Installation and Maintenance Instructions for... Piece No. 32-J Rev 3

CCP2-FLR1-21_ flange-rod operating mechanism

COOPER POWER SERIES. Externally fused block banks installation instructions. Capacitors MN230004EN

O & M Manual for the EATON Generator Ready Loadcenter

Installation Instructions for KPS and KPH Circuit Breakers and Molded Case Switches

INSTRUCTIONS For Field Assembly, Installation, and Maintenance

CMU medium voltage power fuses

Installation Instructions For Motor Control Center (MCC) Units

Instruction Booklet IB E. Contents

Instruction Booklet for the Installation, Operation and Maintenance of Type 5-15 kv VCP-WG Vacuum Circuit Breaker 4000A MiniMod

INSTRUCTIONS Ç CAUTION. S&C Power Fuses Types SMD-1A, SMD-2B, SMD-2C, and SMD-3. For Field Assembly and Installation NOTE INSTRUCTION SHEET

ELB ELB

Instructions for VCP-W Simple Electrical Ground & Test Device (SEG&TD) with simplified interlock scheme - bottom terminal set version

COOPER POWER SERIES. VFI tester operating instructions. Underground Distribution Switchgear MN285001EN

COOPER POWER SERIES. RVAC Fluid-insulated Vacuum Switchgear; Installation, Operation, and Maintenance Instructions. Switchgear MN285005EN

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Vacuum Circuit Breaker (Vehicle)

INSTRUCTIONS Ç CAUTION Ç IMPORTANT

Effective October 2016 Supersedes January 2014 (S )

Installation, Operation, and Maintenance

5/15/27 kv, 25/31.5/50/63 ka Manual Ground & Test Devices Installation, Operations and Maintenance Manual

Vacuum Circuit Breakers (Vehicle)

COOPER POWER SERIES. Types VWE, VWVE27, VWVE38X, WE, WVE27, and WVE38X; threephase electronically controlled; installation and operation instructions

DANGER. See Wiring Diagrams on page 7 for illustrations of both internal and connection wiring diagrams. WARNING

Raychem CSJA Safety Instructions. Safety Instructions. Customer Service. Kit Contents. Installation Instructions

COOPER POWER SERIES. Type MOST Fluid-Insulated Switchgear; Installation, Operation, and Maintenance Instructions

Magnum Breaker Remote Racking Device (MRR1000)

Installation Instructions for R-Frame G-Series (RG) 310+ Trip Unit

TVSS Installation for RLCM/CHGENLC, RLCU, and CHGEN ATSs

Manual Transfer Switch

COOPER POWER SERIES. Three-phase pad-mounted compartmental type transformer installation and maintenance instructions

Installation Power Management Unit Battery Cables and Battery Harness

ELB ES. Product Installation Instructions

S Contents. Applicable to Serial Numbers A101 and above or beginning with CP57.

CM52 Network Protector with Arc Flash Reduction Module

Edison modular fuse, vault application products

Transcription:

Fusing Equipment MN132032EN Effective September 2018 Supersedes November 2016 COOPER POWER SERIES CMU Medium voltage power fuse installation instructions

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The information, recommendations, descriptions and safety notations in this document are based on Eaton Corporation s ( Eaton ) experience and judgment and may not cover all contingencies. If further information is required, an Eaton sales office should be consulted. Sale of the product shown in this literature is subject to the terms and conditions outlined in appropriate Eaton selling policies or other contractual agreement between Eaton and the purchaser. THERE ARE NO UNDERSTANDINGS, AGREEMENTS, WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE OR MERCHANTABILITY, OTHER THAN THOSE SPECIFICALLY SET OUT IN ANY EXISTING CONTRACT BETWEEN THE PARTIES. ANY SUCH CONTRACT STATES THE ENTIRE OBLIGATION OF EATON. THE CONTENTS OF THIS DOCUMENT SHALL NOT BECOME PART OF OR MODIFY ANY CONTRACT BETWEEN THE PARTIES. In no event will Eaton be responsible to the purchaser or user in contract, in tort (including negligence), strict liability or other-wise for any special, indirect, incidental or consequential damage or loss whatsoever, including but not limited to damage or loss of use of equipment, plant or power system, cost of capital, loss of power, additional expenses in the use of existing power facilities, or claims against the purchaser or user by its customers resulting from the use of the information, recommendations and descriptions contained herein. The information contained in this manual is subject to change without notice. ii

Contents DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY... II SAFETY FOR LIFE... IV SAFETY INFORMATION... IV Safety Instructions...iv PRODUCT INFORMATION.... 1 Introduction...1 Acceptance and initial inspection...1 Handling and storage...1 Quality Standards...1 Precautions...1 INSTALLATION FOR NEW APPLICATIONS... 2 Installation (fusing) in pad-mount/indoor applications with exhaust control device...2 Storage and re-use of end fittings...2 INSTALLATION (FUSING) IN OUTDOOR MOUNTINGS.... 3 REPLACEMENT FOR EXISTING APPLICATIONS.... 3 Replacement (re-fusing) in pad-mount/indoor applications with exhaust control devices...3 Replacement (re-fusing) in outdoor mountings...3 iii

! SAFETY FOR LIFE Safety for life! SAFETY FOR LIFE Eaton meets or exceeds all applicable industry standards relating to product safety in its Cooper Power series products. We actively promote safe practices in the use and maintenance of our products through our service literature, instructional training programs, and the continuous efforts of all Eaton employees involved in product design, manufacture, marketing, and service. We strongly urge that you always follow all locally-approved safety procedures and safety instructions when working around high-voltage lines and equipment, and support our Safety For Life mission. Safety information The instructions in this manual are not intended as a substitute for proper training or adequate experience in the safe operation of the equipment described. Only competent technicians who are familiar with this equipment should install, operate, and service it. A competent technician has these qualifications: Is thoroughly familiar with these instructions. Is trained in industry-accepted high- and low-voltage safe operating practices and procedures. Is trained and authorized to energize, de-energize, clear, and ground power distribution equipment. Is trained in the care and use of protective equipment such as arc flash clothing, safety glasses, face shield, hard hat, rubber gloves, clampstick, hotstick, etc. Following is important safety information. For safe installation and operation of this equipment, be sure to read and understand all cautions and warnings. Hazard Statement Definitions This manual may contain four types of hazard statements: DANGER Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury. Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. NOTICE Indicates a potentially hazardous situation which, if not avoided, may result in equipment damage only. Safety instructions Following are general caution and warning statements that apply to this equipment. Additional statements, related to specific tasks and procedures, are located throughout the manual. DANGER Hazardous voltage. Contact with hazardous voltage will cause death or severe personal injury. Follow all locallyapproved safety procedures when working around highand low-voltage lines and equipment. G103.3 Before installing, operating, maintaining, or testing this equipment, carefully read and understand the contents of this manual. Improper operation, handling, or maintenance can result in death, severe personal injury, and equipment damage. G101.0 This equipment is not intended to protect human life. Follow all locally-approved procedures and safety practices when installing or operating this equipment. Failure to comply can result in death, severe personal injury, and equipment damage. G102.1 Power distribution and transmission equipment must be properly selected for the intended application. It must be installed and serviced by competent personnel who have been trained and understand proper safety procedures. These instructions are written for such personnel and are not a substitute for adequate training and experience in safety procedures. Failure to properly select, install, or maintain power distribution and transmission equipment can result in death, severe personal injury, and equipment damage. G122.2 iv

CMU Medium voltage power fuse Eaton s Cooper Power series CMU Expulsion Power Fuse is designed to be installed in accordance with normal safe operating procedures. These instructions are not intended to supersede or replace existing safety and operating procedures. READ ALL THE INSTRUCTIONS BEFORE INSTALLING THE CMU fuse. The CMU fuse should be installed and serviced only by personnel familiar with good safety practice and the handling of high-voltage electrical equipment. Product information Introduction Eaton s Cooper Power series CMU Power Fuse is a Boric Acid, expulsion-style fuse unit that is suitable for both indoor and outdoor applications. In comparison to the conventional distribution cutout that uses the fiber tube and fuse link design for fault interruption, the CMU far exceeds the cutout in interrupting rating, and considerably reduces the hazards and noise of the violent exhaust common to cutouts under fault interrupting conditions. Read this manual first Read and understand the contents of this manual and follow all locally approved procedures and safety practices before installing or operating this equipment Additional information These instructions cannot cover all details or variations in the equipment, procedures, or process described nor provide directions for meeting every possible contingency during installation, operation, or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for the user s purpose, please contact your Eaton representative. CMU Expulsion Power Fuses are designed with maximum operating voltage and interrupting ratings. Operations that exceed the fuse rating may cause the fuse to fail, resulting in death, bodily injury and/ or property damage. Refer to catalog section 240-94 for rated operating voltage and maximum interrupting capability. Figure 1. CMU fuse in indoor and outdoor fittings Acceptance and initial inspection Each fuse is completely assembled, inspected and tested at the factory. It is in good condition when accepted by the carrier for shipment. Upon receipt of a fuse, inspect the connector thoroughly for damage and loss of parts incurred during shipment. If damage or loss is discovered, file a claim with the carrier immediately. Handling and storage If the fuse is to be stored for an appreciable time before installation, provide a clean, dry storage area. Locate the fuse so as to minimize the possibility of physical damage. Quality Standards ISO 9001 Certified Quality Management System Precautions These instructions cover the safe installation, replacement and maintenance of Eaton s Cooper Power series CMU fuses with approved indoor or outdoor distribution fuse holders. Appropriate end fittings must be correctly attached to the fuse before it can be installed in a fuse holder. CMU fuses can be installed in any approved fuse holder as long as the correct end fittings for the particular type of fuse holder are used. There are three different types of end fittings for use in various types of fuse holder. 1

CMU Medium voltage power fuse The fuses described in this installation instruction are designed and tested to operate within their nameplate ratings. Though Eaton s Cooper Power series CMU fuses are sealed, we recommend that the fuse not be allowed to hang inverted in the open position. There is a remote possibility of seal damage that could cause moisture ingress into the fuse while in this position, which could adversely affect the performance of the boric acid arc-quenching solid filler. Store the fuses in the original shipping package with the internal packaging intact in an area free from excessive moisture. Installation for new applications Any and all applicable safety regulations must be strictly adhered to concerning the closure or possible closure of CMU fuses onto live circuits. Upper End Fitting Lower End Fitting CMU Fuse Unit Contact Rod Locating Pin (inside bore) Actuating Pin - extends through Upper Seal when Fuse Unit is blown and extends the Blown-Fuse Indicator Colored End Cap (remove and discard before installing Muffler) Muffler Blown-Fuse Indicator (in blown-fuse position)* Clamp Screw Locating slot (inside bore) Upper Seal Locating Slot Lower Ferrule Locating Pin Shoulder Fuse Unit with End Fittings and Muffler attached. End fittings should only be attached immediately prior to installation. Handle fuses with care do not drop them or throw them! Do not place hand over upper seal of fuse unit when handling. [There is a remote possibility that the current-responsive section of the fuse unit may have been weakened in shipping or handling. As a result, the springloaded latch-tripping pin may be unpredictably released and driven forcibly through the upper seal.] Do not remove or loosen the red lower seal, unless the fuse unit is to be used with an exhaust control device. In this case, remove the red cap immediately prior to installing the device. Installation (fusing) in pad-mount/indoor applications with exhaust control device Attach fuse end fittings (Figure 2) as follows: 1. The lower end fitting must be attached first. Remove and discard the red cap located on the lower end of the fuse. Next, slip the lower end fitting over the upper end of the fuse and slide it down until the locating slot is seated on the locating pin on the lower ferrule. Then thread the muffler on to the lower end fitting and tighten it firmly. The final fractional turn should be made with a bar or a wrench handle. 2. Slip the upper end fitting over the fuse. Align the locating pin (inside the upper end fitting) with the locating slot in the fuse and seat the upper end fitting firmly against the upper end of the fuse. Tighten the clamp screw firmly. Storage and re-use of end fittings Unused fuse end fittings A coating of oxidation-inhibiting grease was applied to the contact rod at the factory. Verify the presence of this oxidation-inhibiting grease, and that it is still free from contaminants. If necessary, clean the contact rod with a non-toxic, nonflammable solvent and apply a coating of oxidation-inhibiting grease. End fittings should be stored in the original shipping package (if possible) in an area free from excessive moisture. End fittings should only be attached to fuse immediately before installation. Figure 2. Indoor CMU fuse fittings Re-use of fuse end fittings Remove the existing coating of oxidation-inhibiting grease and dirt from the contact rod using a nontoxic, nonflammable solvent. Inspect the contact rod for evidence of pitting. If pitting has occurred, file down any projections, abrade the surface until smooth with an abrasive cloth or scratch brush, and wipe clean. Apply a new coating of oxidation-inhibiting grease to the contact rod. If the contact has been burned, the contact and its mating part should be replaced. 2

CMU Medium voltage power fuse Installation (fusing) in outdoor mountings Attach the fuse end fittings (Refer to Figure 3) as follows: 1. The lower end fitting must be attached first. Slip the lower end fitting over the upper end of the fuse and slide it down until the locating slot seats on the locating pin on the lower ferrule of the fuse. Next, back off the locknut on the clamp screw and tighten the clamp screw firmly; secure it with the locknut. 1. Slip the upper end fitting over the fuse. Align the locating pin (inside the upper end fitting) with the locating slot in the fuse and seat the upper end fitting firmly against the upper end of the fuse. Tighten the clamp screw firmly. Do not remove the red outer cap from the bottom of the fuse. Replacement for existing applications Replacement (re-fusing) in pad-mount/indoor applications with exhaust control devices A Non-Loadbreak fuse holder does not incorporate live switching capacity. Therefore, an unblown CMU fuse in such a mounting must not be moved to the Open position without first opening an upstream interrupting and isolating switch or loadbreak device. 1. When the fuse operates, the fuse does not swing open, but the blown fuse indicator moves to the extended position, providing visual evidence that the fuse has operated. Move the fuse to the Open position and then remove it from the mounting. 2. Loosen the upper end fitting clamp screw, and loosen the clamp slightly using a screwdriver. Slide the upper end fitting off the upper end of the fuse. Then unscrew and remove the muffler. Slide the lower end fitting off the upper end of the fuse. (Refer to Figure 2) 3. Attach the end fittings and muffler to a new fuse, following the instructions in new installations on page 3. A fuse that has operated cannot be salvaged. Dispose of it properly. 4. To avoid the delay of transferring end fittings, spare sets of end fittings and mufflers may be kept on hand for attachment to new fuses immediately before re-fusing. 5. Unused or re-used end fittings should be handled as indicated in Storage and re-use of end fittings above. Any and all applicable safety regulations must be strictly adhered to concerning the closure or possible closure of CMU fuses onto live circuits. Upper End Fitting Lower End Fitting CMU Fuse Unit Clamp screw Clamp Locating Slot Upper Seal Locating Slot Lower Ferrule Locating Pin Locating Pin (inside bore) Locknut Clamp screw Actuating Pin extends through Upper Seal when Fuse Unit is blown and extends the Blown- Fuse Indicator Colored End Cap must not be disturbed when CMU fuse unit is used in CMU fuse mounting Figure 3. Oudoor CMU fuse fittings Fuse unit with end fittings attached. Replacement (re-fusing) in outdoor mountings 1. When the fuse operates, the fuse assembly swings to the Open position. Remove it from the mounting, using a hookstick. Examine the end of the fuse to determine that the actuating pin (Refer to Figure 3) extends through the upper seal, indicating that the fuse has operated. 2. Loosen the upper and lower end fitting clamp screws (if necessary, pry the upper end fitting apart slightly with a screwdriver), and slide both end fittings off the upper end of the fuse. 3. Next, attach the end fittings to a new fuse, following the Installation for new applications. A fuse unit that has operated cannot be salvaged. Discard it. 4. To avoid the delay of transferring end fittings, spare sets of end fittings may be kept on hand for attachment to new fuses immediately before re-fusing. (See Storage and re-use of end fittings) 5. Unused or re-used end fittings should be handled as indicated in Storage and re-use of end fittings above. 3

! SAFETY FOR LIFE Eaton 1000 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Power Systems Division 2300 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2018 Eaton All Rights Reserved Printed in USA Publication No. MN132032EN / Rev. 0 September 2018 Eaton is a registered trademark. All trademarks are property of their respective owners. For Eaton's Cooper Power series product information call 1-877-277-4636 or visit: www.eaton.com/cooperpowerseries.