S.C.C. Syllabus. Note 3 : A candidate qualifying in part 5 need not qualify further in part 12. SYLLABUS FOR SUPERVISORS. Part-1

Similar documents
SYLLABUS FOR ELECTRICAL SUPERVISOR CERTIFICATE OF COMPETENCY (SCC MV) Electrical Engineering Paper (Written Test)

Chapter 14:08 Factories and Works (Electrical) Regulations, Chapter 14:08 Factories and Works (Electrical) Regulations, 1976

Comparison of Indian Electricity Rules, 1956 Vs CEA (Measures relating to Safety and Electric Supply) Regulations, 2010

INTERACTIVE SCIENCE 2A

Electrical Measuring Instruments

Syllabus for the Trade of Electrician Duration : Six Month Second Semester Semester Code: ELE: SEM II

Chapter Assessment Use with Chapter 22.

COURSE: Power Generation and Economics DEPARTMENT: Electrical and Electronics Engineering ACADEMIC YEAR: COURSE CODE: 15EE42 SEMESTER: IV TOTA

ELECTRIC POWER AND HOUSEHOLD CIRCUITS

Unit AE01K Knowledge of Locating and Correcting Simple Electrical Faults in the Automotive Workplace

ELECTRICAL MAINTENANCE

Scale of Inspection Fees of Electrical Inspectorate Schedule. I. Fees for Initial Inspections:

Electrical Energy and Power Ratings

SSC-JE STAFF SELECTION COMMISSION ELECTRICAL ENGINEERING STUDY MATERIAL. Estimation and Costing & Utilization of Electrical Energy

CHAPTER 6.3: CURRENT ELECTRICITY

ES5 Security Theory/Regulations Answer Schedule

2. DEFINITIONS. 2.3 APPROVED Acceptable to the authority enforcing the National Electric Code

Higher National Unit Specification. General information for centres. Electrical Motors and Motor Starting. Unit code: DV9M 34

Electrical Circuits Discussion Questions:

Electrical Controls. Syllabus

Electricity Unit Review

Conceptual Physics Electricity and Circuits Practice Exam 2011

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

POWER METER. my2010 (c)

ELECTRICIAN S THEORY EXAMINATION 11 September 2010 QUESTION AND ANSWER BOOKLET

KAUAI ISLAND UTILITY COOPERATIVE KIUC Tariff No. 1 Lihue, Kauai, Hawaii Original Sheet 5 RULE NO. 2 CHARACTER OF SERVICE

FOR SUPW CLASSES IN KENDRIYA VIDYALAYAS

Syllabus. For the trade of. Under Apprenticeship Training Scheme In the Informal Sector. Designed in 2002

Current Electricity. 3 rd Years

NZQA registered unit standard version 3 Page 1 of 5. Demonstrate and apply knowledge of electrical machines

: HOUSE WIRING. Attendance : 90% attendance is must to appear for the examination COURSE THEORY PRACTICAL TOTAL HOUSE WIRING

NATIONAL CERTIFICATE (VOCATIONAL) ELECTRICAL SYSTEMS AND CONSTRUCTION NQF LEVEL 2 NOVEMBER 2009

The Knowledge Bank at The Ohio State University. Ohio State Engineer. Electrolysis in Underground Structures

Electrical Equipment and Terminology

Volume 2 Charts, Formulas, and Other Useful Information

Electrical Tech Note 106

Syllabus for the Trade of Wireman Duration : Six Months

45 Current Electricity. February 09, Current Electricity. What we will learn, Arc Attack. Electric Man. 1

Chapter: Electricity

WORKSHOP MANUAL ELECTRICITY

CLIENT: PROJECT: PO#: ESTIMATOR:

Total duration of course = 3 Months (12 weeks) Total training hours = 400 hrs.

UNIT 1 ELECTRICIAN S MATH AND BASIC ELECTRICAL FORMULAS...1 Introduction...1. UNIT 2 ELECTRICAL CIRCUITS...49 Introduction...49

CCE RR KARNATAKA SECONDARY EDUCATION EXAMINATION BOARD, MALLESWARAM, BANGALORE G È.G È.G È.. Æ fioê, d È 2017

EE069: Electrical Engineering for Non-Electrical Engineers

THE AUXILIARY EQUIPMENT OF THE CHICAGO, MILWAUKEE AND ST. PAUL LOCOMOTIVES

CENTRAL ELECTRICITY AUTHORITY (MEASURES RELATING TO SAFETY AND ELECTRIC SUPPLY) REGULATIONS, 2010

SQA Advanced Unit specification: general information

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION

This standard covers the requirements of lighting chains. This standard covers only the safety requirements.

Class X Chapter 09 Electrical Power and Household circuits Physics

MILLWRIGHT. Learner Program Content:

Œ æ fl : GΔ»ÊflMmÈ A±È BMf æ fl MVÈ

Training & Didactic Systems. Fundamentals of Electrical Engineering

Modern Auto Tech Study Guide Chapter 8 Pages Electricity & Electronics 37 Points. Automotive Service

Dev Bhoomi Institute Of Technology LABORATORY Department of Electrical And Electronics Engg. Electro-mechanical Energy Conversion II

Single Phase Induction Motor. Dr. Sanjay Jain Department Of EE/EX

Building Operator Certification Level I

Ohm s Law. 1-Introduction: General Physics Laboratory (PHY119) Basic Electrical Concepts:

INDIAN MARITIME UNIVERSITY KOLKATA CAMPUS

Revised December, Copyright reserved (NVTI Testing Division)

ELECTRICIAN S THEORY EXAMINATION 19 June 2010 QUESTION AND ANSWER BOOKLET

Question 2: Around the bar magnet draw its magnetic fields. Answer:

Full file at

PHYSICS 6 EXTENDED PHYSICS

4 Electric Circuits. TAKE A LOOK 2. Identify Below each switch, label the circuit as a closed circuit or an open circuit.

Direct-Current Circuits

NCCER Progress Blvd. Alachua, FL

OSHA Update. Electric Power Generation, Transmission and Distribution Standard (Part 1910 & 1926)

18.5. Electrical Circuits and Safety

to allow a current in one circuit to operate a switch in another circuit to protect a circuit by melting if the current becomes too large

2014 ELECTRICAL TECHNOLOGY

CLP POWER HONG KONG LIMITED. SUPPLY RULES March 2001

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET

Basic Electrical Engineering

L E A R N I N G O U T C O M E S

AFTER GAZETTING (WORKING DOCUMENT FOR A 3 YEAR PERIOD) DATE PAGE PARAGRAPH DESCRIPTION ORIGINATOR APPROVED

Unrestricted. S.Mukhopadhyay

Model Volt-Amp-Wattmeter INSTRUCTION MANUAL

Institute of Technology, Nirma University B. Tech. Sem. V: Electrical Engineering 2EE305: ELECTRICAL MACHINES II. Handout: AC Commutator Motors

TABLE OF CONTENTS CHAPTER 1 ELECTRICAL THEORY About This Textbook...xi. Passing Your Exam...xiv. How to Use the National Electrical Code...

Digital Multimeter AHMAD FOUAD ALWAN

ELECTRICAL SERVICE TECHNICIAN EXAMINATION 25 November 2017 QUESTION AND ANSWER BOOKLET

TESCO THE EASTERN SPECIALTY COMPANY Date: 05/04/15 Canal Street and Jefferson Avenue Bristol, PA 19007

ELECTRICAL TECHNOLOGY 3 March 2008


TABLE OF CONTENTS. About the Mike Holt Enterprises Team... xviii CHAPTER 1 ELECTRICAL THEORY... 1

CSDA Best Practice. Hi-Cycle Concrete Cutting Equipment. Effective Date: Oct 1, 2010 Revised Date:

Periodic comprehensive review of the CEA (Measures relating to Safety and Electric Supply) Regulations, 2010 (as amended)

"Accredited Test Laboratory" (ATL) means an organisation that is accredited by the South African National Accreditation System (SANAS).

Basics of Control Components

PHYSICS MCQ (TERM-1) BOARD PAPERS

Contents. Chapter No. Title Page No. 1 Overview of a Ship s Electrical System 1. 2 Electrical Safety 41

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

University of Houston Master Construction Specifications Insert Project Name

Electricity Course. Part B Course Outline

Valliammai Engineering College

ELECTRICITY & MAGNETISM - EXAMINATION QUESTIONS (4)

Surface Regulations and Policies

9. Effects of an electric current

Transcription:

S.C.C. Syllabus Certificate For :- Parts Compulsory Wiring for systems not exceeding 650 Volts. : 1 & 2 D.C. Apparatus not exceeding 650 Volts. : 1, 2 & 3 A. C. Apparatus not exceeding 650 Volts. : 1, 2 & 4 Installations exceeding 650 Volts : 1, 2, 3, 4 & 5 Aerial lines exceeding 250 Volts. : 1 & 6 Underground cables : 1 & 7 Mining : 1, 2, 4 & 8 Lifts : 1, 2, 3, 4 & 9 Electric Signs : 1, 2, 3, 4 & 10 Wring for system not exceeding 250 Volts. : 1 & 11 only Transformer installation exceeding 650 Volts. : 1, 2 & 12 only Note 1 Note 2 : Part 1 is compulsory to all candidates. The passing of the parts stated above are cumulative and progressive. That is the candidate must pass in all parts and the sequence shown. : Certificates endorsed for underground cable work and for work serial lines exceeding 250 Volts will be divided into sections A, B and C which are progressive and cumulative. Certificates granted to successful candidates will be endorsed to denote the section or sections in which they have qualified. Note 3 : A candidate qualifying in part 5 need not qualify further in part 12. Explanation : Part 12 is included in the syllabus in part-5. SYLLABUS FOR SUPERVISORS Elementary Principals : Part-1 Electrical properties of material - Conductors and insulators. The effect of commonly occurring conditions such moisture, heat, etc. Conditions which hasten deterioration. Magnetic properties of materials - Magnetization by electric currents, electro-magnets and their application. Conductors, bare and insulated. Their resistance and safe current carrying capacity, calculation of size of conductors for connected load with due regard to heating and voltage drop. Electrical measurements - Application of Ohm's Law to simple method of ascertaining resistance, voltage and current. The use of ammeters, voltmeters, ohmmeters, wattmeters, ampere-hour meters, kilowatt-hour meters and their connections. Electric shock - Action to be taken, method and duration of treatment in case of persons suffering from electric shock. Drawing - Making and reading drawings of power and lighting circuit diagrams. Grades and classes of cables - Their suitability for different kinds if installation work. The installation and systematic testing of cables for continuity. leakage, insulation-resistance and the testing of connections. Indian Electricity Rules - A general knowledge, particularly of chapters V and VI of the rules. Page 1 of 5

Part-2 Wiring of systems up to but not exceeding 650 volts. Connection of low pressure installations to medium pressure supply mains. Wring installation including connections work specifications for power and other purposes but excluding the installation work specifically covered by parts 3 & 4. Indian Electricity Rules - A working knowledge of the Indian Electricity Rules as applicable to installation work of this part. Part-3 DC Apparatus exceeding 250 volts and not exceeding 650 volts. Generators - D.C. Series, shunt and compound wound, elementary theory, installation, operation, parallel running of machines, balancers. Motors - D. C. Series, shunt and compound wound, elementary theory, their uses, installation, operation and speed control. Control Gear - The various type of switches, fuses, starters, controllers, regulators, their uses and installation. Installations in general including portable appliances but work specifically covered by parts 4, 5 & 6. Indian Electricity Rules - A working knowledge of the provisions of the Indian Electricity Rules as applicable to the installation work of this part. Part-4 A.C. Apparatus exceeding 250 volts and not exceeding 650 volts. Generators - A.C. single and poly phase, elementary theory, Installation, operation, parallel running of machines, rotary converters, power meters frequency meter, and synchroscopes. Motors - A.C. single and poly phase, induction synchronous machines, elementary theory, their uses, installation, operation and speed control. Control gears - The various types of switches, fuses, starters, controllers, regulators, their uses and installation. Installation in general including portable appliances but excluding that installation work specifically covered by parts 5 & 6. Indian Electricity Rules - A working knowledge of the previsions of the Indian Electricity Rules as applicable to installation work of its part. Installation exceeding 650 volts. Part-5 Note :- A candidate must pass in parts 1, 2, 3 & 4 before appearing in an examination for part 5 : Provided that they appear for all the parts at the same examination but will not be granted certificate in part 5 should they fail in either part 1, 2, 3 and 4. Generators - Motors and their control gear as in part 3 and 4 but exceeding 650 volts and also rectifiers and other high pressure apparatus. Page 2 of 5

Transformers :- general principal, elementary calculation various type and uses, installation, wiring connection, operation phasing out and parallel operation. A working knowledge of the India Electricity Rule as cable be installation work of this part. Aerial line exceeding 250 volts. For (A) Voltage upto 650 volts. (B) Voltage upto 33000 volts. (C) Voltage exceeding 33000 volts. Part-6 General practical knowing of erection under varying climatic conditions, passing of conductor, the uses of guys, struts, guard wires, safety devices, lighting conductors and arresters, testing of the installation and earthing. A working knowing of the Indian Electricity Rules as applicable to such aerial lines. Part-7 For (A) Voltage upto 1000 volts. (B) Voltage upto 1 1000 volts. UNDERGROUND CABLE (C) Voltage upto and exceeding 33000 volts. (Paper or-cambric) oil filled, gas filled or any other types. General practical knowledge of lying direct in ground, in troughs and in pipes, handling, bending, jointing, plumbing, under ground and above ground joint boxes, junction boxes and distribution boxes and pillars, joint box compound, melting of compounds, filling boxes with a compound. A working knowledge of the Indian Electricity Rules as applicable to such underground cable. Part-8 REGULATIONS AS REQUIRED BY THE DEPARTMENT OF MINES GOVERNMENT OF INDIA Mining installation (below ground) Candidates for this part must have had a minimum of one year practical experience in electrical installation work in mines below ground. This part will cover those features of installation work which are practicular and peculiar to installations (below ground in mines). Before a candidate will be granted a certificate for mining installation (below ground), I. E. (part-8), he must, in addition to satisfying the Board in part1, have qualified in parts 1, 2 and 4. general knowledge of cables used in mines : Joining, junction boxes, joint box compounds and testing. Page 3 of 5

Electric haulage and winders, mining and electrical machinery and apparatus, as applicable to mines. Portion of the Indian Electricity Rules specially applicable to mines. Note :(1) Those candidates who desire a certificates for supervising high pressure work below ground must also qualify in part-5. (2) Any person who holds a certificate for mining installation (below ground) shall also be entitled to supervise surface installations of the nature covered by the syllabus for the part in which he was qualified. Similarly if a person is required to supervise work of the nature covered by the syllabus in part6 and 11 must also qualify in those parts. (3) For the supervision of Electrical installation below ground in gassy mines, persons who hold certificates for supervising electrical installations in mines below ground shall have their certificate endorsed for supervising such installations in "Gassy Mines" if they can produce satisfactory evidence that they have a minimum of SIX months practical experience of electrical installation in gassy mines below ground. Part-9 ELECTRICAL LIFTS N.B :- The Indian Electricity Act and Rules do not extend beyond the electrical equipment installation and used in lifts. General principles :- Installation and connection of A.C. and D.C. motors p to but no exceeding 650 volts, controllers and safety devices as used in lifts. Part-10 ELECTRICAL SIGNS. Filament lamps, electric discharge lamps, luminous tubes, flashers, etc.their installation, connections, operation and precautions to be taken. A through knowledge of the special installation fur such signs as used under the Indian Electricity Rules. Part-11 Wiring for systems not exceeding 250 volts Cleat, Wood :- Casing, lead covered, cab-type sheathed, conduit and armoured cable together with main switches and out-cuts, distribution boards, and correct installation of switches. Low pressure electrical appliances - Such as heaters, cookers, small motors for pumps, refrigerators, electric bells and indicators worked off electric supply lines, Wither portable or otherwise. Low pressure serial lines general principles of construction, strength of posts, length of spans, spacing of conductors, height of conductors, cross arms, guard wire, safety devices, earthing, lightning conductors and arrestors, testing. Indian Electricity Rules :- A working knowledge of the Indian Electricity Rules as applicable to installation work of this part. Page 4 of 5

Part-12 TRANSFORMER INSTALLATION EXCEEDING 650 VOLTS. TRANSFORMER :- General principles, elementary calculations, various types and uses, installation, wring connections, operation, phasing out and parallel operations, earthings, tapchangings and safety precautions. A working knowledge of the Indian Electricity Rules as applicable to installation works of the part. Note :- A candidate must pass in parts 1 & 2 before appearing in an examinaation for part 12 provided that he may appear for all parts at the same time examination but will not be granted a certificate in part-12 (should he fail in either of parts 1 & 2). Page 5 of 5