Technical data. Standards: IEC/EN EN 574 EN 418. powder-coated Protection class: IP 65. Cable section: max. 1.5 mm V I the :

Similar documents
Solenoid interlocks AZM 190 range. 128 Schmersal ,3 4,5 M20 17,5 23,5

Solenoid interlocks AZM 170 range. 98 Schmersal 22 8,2 60. ø4,2. ø Pg 11

Solenoid interlocks AZM 161 range Schmersal. a 5,5. Pg11/M16x1,5

PROTECT SRB s Safety relay modules with intrinsically safe monitoring circuits Ex i L-protection for ATEX zones 1, 2, 21 and 22.

Technical data. Standards: IEC/EN ; EN ISO ; EN 1088; BG-GS-ET-19

Technical data. Standards: IEC/EN BG-GS-ET-15

Safety Switches with Separate Actuator SKC

Safety technique. Emergency Stop Module BH 5928, BI 5928

AZM 161SK 12/12RKED/TU 024

Safety door-handle system STS

SEPK 02.0 / SEPG 05.3 / SEP 01.0 / SEP 01.4 / SEPLC 05.2 / SEP 07.0 / SEP Operating instructions Two-hand control panel

Single foot switches PX and PA series

Ordering details. Approval. Classification. Global Properties :18:33h. Solenoid interlock / AZM 161

Solenoid interlocks AZM 415 range. 134 Schmersal 29,5 6,5 24,7. 8,6 Pg 13,5 46,5 24,5

Recommended use With its standard enclosure, the ENM2 limit switch can be used universally in all industrial and safety applications.

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

Installation and Operating Instructions

L1 = Solder terminal 2.8 x 0.5 mm Ø Behind panel

Single foot switches PX and PA series

Datasheet - AZ ZUEK Safety switch with separate actuator / AZ 3350

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Electronic Braking Systems

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

SFS-UFS Single Foot Switches

Installation and Operating Instructions

Floor and fine adjustment switches

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Safety switches with solenoid and separate actuator

Safety switches with solenoid and separate actuator

Datasheet - TV8S /20Z Safety switch for hinged guards / Hinge safety switch / TV8S 521

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

Command devices Pull-wire emergency stop switches One-side operation ZS 71 range Schmersal Industrial Switchgear.

Scheda prodotto Relè Series B

DEVICE STATE/BYPASSED FAILURE OVERLOAD

Standard Rope Pull Switches. With and Without Latching Function SIEM2 SID SIN SGC SI88. The field of application for these rope pull switches includes

Safety switches for hinged doors

Solenoid interlock AZM 200 The non-contact interlock.

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Limit Switch - Safety Type with pull button reset Plastic Body IP65 and Metal Body IP66

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

NR2 Thermal Overload Relay. 1. General. 2. Type Designation. 3. Features. Relays. EU Germany Ukrain Russia South Africa USA

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Load disconnect switch Series 8146/5-V11

Thermal Overcurrent Circuit Breaker 3120-F...

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Technical data. Rated operating current/voltage I e /U e : AC-15: 2 A / 24 VAC DC-13: 1 A / 24 VDC Thermal test current I the : 2.

Guard locking systems for the protection of man and machine

Safety switches / Position switches / Command devices

Micro Contactor MA Series

AF40... AF96 3-pole contactors Technical data

Magnetic and Hydraulic-Magnetic Circuit Breaker

Control Equipment. ATHEX bvba Tel: +32 (0) Fax: +32 (0) Alpenroosbaan 2, 2900 Schoten, België

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

General Purpose Relays Accessories. Accessories Industrial Power Relay RT

Motor protective circuit breakers

Thermal Overcurrent Circuit Breaker 3120-F...

3RT14 Contactors with 3 Main Contacts

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

V REG.-Nr. 6106, Z E SCHRACK. Accessories Industrial Power Relay RT. General Purpose Relays. pinnings 3.5mm / 5mm; relay height 15.

Safety switches with separate actuator

Technical Information

Magnetic and Hydraulic-Magnetic Circuit Breaker

Power distribution. RiLine fuse elements. NH fuse-switch disconnectors, size 000. For mounting plate assembly

Emergency stop without emergency switching off/emergency stop function. Locking facility Lockable in the 0 (Off) position N/O 0 B 0

Application Mini Contactors for Motors and Resistive Loads

D509E. Manual Motor - Starters

Technical data. Standards: IEC/EN chromated and painted Protection class: IP 67 to EN 60529

TMC 91H is now TMC 60 C Series

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Thermal Overcurrent Circuit Breaker 3120-F...

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Limit Switch - Prewired Type Metal Body

Electronic overload relays EF205 and EF370

Emergency stop As an emergency switching off/emergency stop device. Standards According to IEC/EN , VDE 0113 Part 1

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

Installation Contactors RIC, RAC

Technical data. Standards: IEC/EN , EN ISO , IEC 61508, IEC

Position switches FR series

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

Safety switches with separate actuator

General technical data: CONTACTOR, AC-3, 11KW/400V, 1NO+1NC, AC110V 50HZ, 120V 60HZ 3-POLE, SZ S0 SCREW TERMINAL. product brand name

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

Prewired position switches FF series

Ex UPS standard Series 8265

General Purpose Relays Power Relays. T9G series, DC coil 30A PCB Relay

Power Electronics. Motor brake relay GA 9031 ministop

Crimpmate Range pitch 5.00

Essential equipment for all your requirements

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Thermal-Magnetic Circuit Breaker M1-...

Magnetic and Hydraulic-Magnetic Circuit Breaker

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

General technical data: CONTACTOR, AC-3, 4KW/400V, 2NO+2NC, DC 24V, 3-POLE, SZ S0 SCREW TERMINAL REMOVABLE AUX. SWITCH. product brand name

Safety switches for hinged doors

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

RockStar HighPower. Contents. RockStar HighPower Introduction C.2 C.1

Fuse switch disconnectors

Transcription:

55 Two-hand control panels SEP System components 460 240 190 30 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 Cable section: max. 1.5 mm 2 U i : 440 V I the : 10 A I e /U e : 8 A / 250 VAC 5 A / 24 VDC Mechanical life: 10 million operations 460 x 160 x 140 mm 95 140 60 108 114 160 400 11,5 Aluminium enlosure 2 black operating push buttons Ø 55 mm each with 1 NC and 1 NO contacts according to EN 574 1 Emergency-Stop button in metal version, EDRRZ 50 RT, with 1 NC and 1 NO contact Protection class IP 65 Standard: SEP 01.0.1.0.22/95 (1NO/1NC per button 1NO/1NC for Emergency-Stop) Empty enclosure: SEP 01.0.L.22 (with 3 mounting holes) Other product variants: List ZHS/03 ELAN, Wettenberg Customer-specific designs (also entirely pre-wired, special colours, etc.) available on request Safety monitoring modules for two-hand control circuits: refer to page 2-24 refer to page 2-26 2-21

SEPK System components 464 410 137 Standards: IEC/EN 60947-5-5 EN 574 EN 418 thermoplastic (Lexan 503 R) Protection class: IP 64 to EN 60529 Cable section: max. 1.5 mm 2 U i : 440 V I the : 10 A I e /U e : 8 A / 250 VAC 5 A / 24 VDC Mechanical life: 10 million operations 469 x 185 x 140 mm ø11,5 469 220 130 60 125 185 125 237 Thermoplastic enclosure 2 black operating push buttons Ø 55 mm each with 1 NC and 1 NO contacts according to EN 574 1 Emergency-Stop button in thermoplastic version, KDRRT 40 RT, with 1 NC and 1 NO contact 8 knockouts for additional operating devices Ø 22.3 mm Stand and wall mounting possible 2 part enclosure Protection class IP 64 Standard: SEPK 02.0.4.0.22/95 (1NO/1NC per button 1NO/1NC for Emergency-Stop) Empty enclosure: SEPK 02.0.L.22 (with 3 mounting holes) Other product variants: List ZHS/03 ELAN, Wettenberg Customer-specific designs (also entirely pre-wired, special colours, etc.) available on request Safety monitoring modules for two-hand control circuits: refer to page 2-24 refer to page 2-26 2-22

SEPG System components 465 205 205 133 Standards: IEC/EN 60947-5-5 EN 574 EN 418 cast aluminium, powder-coated Protection class: IP 65 to EN 60529 Cable section: max. 1.5 mm 2 U i : 440 V I the : 10 A I e /U e : 8 A / 250 VAC 5 A / 24 VDC Mechanical life: 10 million operations 494 x 184 x 160 mm 136 127 86 494 228 66 118 184 160 82 130 237 Aluminium enlosure 2 black operating push buttons Ø 55 mm each with 1 NC and 1 NO contacts according to EN 574 1 Emergency-Stop button in metal version, EDRRZ 50 RT, with 1 NC and 1 NO contact Control panel suitable for mounting 8 supplementary signalling and command devices Stand and wall mounting possible 2 part enclosure Protection class IP 65 Standard: SEPG 05.3.4.0.22/95.23 (1NO/1NC per button 1NO/1NC for Emergency-Stop) Empty enclosure: SEPG 05.3.L.22 (with 3 mounting holes) Other product variants: List ZHS/03 ELAN, Wettenberg Customer-specific designs (also entirely pre-wired, special colours, etc.) available on request Safety monitoring modules for two-hand control circuits: refer to page 2-24 refer to page 2-26 2-23

Safety-monitoring module to monitor two-hand controls to EN 574-1 III C 2 enabling paths, Stop 0 1 auxiliary NC contact with antivalent functioning principle (auxiliary contacts are not to be used in safety circuits) Feedback circuit 4 LEDs to show operating conditions Control Category 4 to EN 954-1 Standards: IEC/EN 60204-1, EN 954-1, BG-GS-ET-20 Stop category 2x Stop 0 Control category: 4 glass-fibre reinforced thermoplastic Cable section: max. 2.5 mm 2 solid or multi-strand lead (incl. conductor ferrules) U e : 24 VAC, 115 VAC, 230 VAC 15%/+6%, 50/60 Hz I e : 0.1 A Protection class: terminals IP 20 enclosure IP 40 to EN 60529 Power consumption: max. 4.0 W Max. fuse rating: Si1 (internal): 125 mat Si2: 80 mat Feedback circuit: yes Drive circuits: S11/S23, S31/S43: max. 28 VDC Enabling contacts: 2 enabling paths enabling paths: 6 A/230 VAC, 6 A/24 VDC Fuse rating: enabling paths: 6 A slow blow Signalling contacts: 1 NC contact Indicating contact: 2 A/24 VDC Contact material: AgSnO, self-cleaning, positive action Contact resistance: max. 100 mω in new condition Pull-in delay: 20 ms Response time: 10 ms Air clearances and creepage distances: DIN VDE 0110-1 (04.97), 2.4 kv/2 Overvoltage category: III to DIN VDE 0110 Degree of pollution: 2 to DIN VDE 0110 Ambient temperature: 0 C + 40 C (Derating curve on request) Mechanical life: 10 million operations 4 LEDs Weight: 360 g 45 x 83 x 140 mm H ➀ No. Replace Description ➀ 24 VAC 24 VAC 115 VAC 115 VAC 230 VAC 230 VAC 2-24

Duties: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. If the feedback circuit S is not needed, the inputs X1 and X2 must be bridged. The NC contact of the buttons A and B must have opened before the NO contact closes. No contact overlapping, otherwise fuse Si2 would be triggered. Wiring diagram L1 A K B K A S A1 X1 X2 S23 S11 S12 A2 14 24 36 SRB 201TH N L1 B S24 S43 S31 S32 S44 13 23 35 Control logic K A K B N LED the integrated LEDs indicate the following operational states. Position relay Position relay Supply voltage U B Internal operating voltage U i The wiring diagram is shown with guard doors closed and in de-energised condition. 2-25

Safety-monitoring module to monitor two-hand controls to EN 574-1 III C 2 enabling paths, Stop 0 1 auxiliary NC contact with antivalent functioning principle (auxiliary contacts are not to be used in safety circuits) Feedback circuit With electronic fuse 2 LEDs to show operating conditions Control Category 4 to EN 954-1 Plug-in terminals Standards: IEC/EN 60204-1, EN 954-1, BG-GS-ET-20 Stop category 2x Stop 0 Control category: 4 glass-fibre reinforced thermoplastic, ventilated plug-in, Cable section: max. 2.5 mm 2 solid or multi-strand lead (incl. conductor ferrules) U e : 24 VDC 15%/+20%, residual ripple max. 10% I e : 0.08 A Protection class: terminals IP 20 enclosure IP 40 to EN 60529 Power consumption: max. 1.2 W Max. fuse rating: internal electronic fuse F1, F2 for monitoring the elements of the two-hand control: tripping current < 0.2 A internal electronic fuse F3: tripping current: < 0.6 A Feedback circuit: yes Drive circuits: S11/S12, S21/S22: max. 28 VDC Enabling contacts: 2 enabling paths enabling paths: 6 A/230 VAC, 6 A/24 VDC Fuse rating: enabling paths: 6 A slow blow Signalling contacts: 1 NC contact Indicating contact: 2 A/24 VDC Contact material: AgSnO, self-cleaning, positive action Contact resistance: max. 100 mω in new condition Pull-in delay: 50 ms Response time: 30 ms Air clearances and creepage distances: DIN VDE 0110-1 (04.97), 4 kv/2 Overvoltage category: III to DIN VDE 0110 Degree of pollution: 2 to DIN VDE 0110 Ambient temperature: 25 C + 45 C (Derating curve on request) Mechanical life: 10 million operations 2 LEDs Weight: 200 g 22.5 x 100 x 121 mm ➀ No. Replace Description ➀ 24 VDC 2-26

Wiring diagram Duties: Suitable for 2 channel control, for increase in capacity or number of contacts by means of contactors or relays with positive-guided contacts. If the feedback circuit S is not needed, the inputs X1 and X2 must be bridged. The NC contact of the buttons A and B must have opened before the NO contact closes. No contact overlapping, otherwise fuses F1 and F2 would be triggered. A1 A1.1 A2.1 S11 S12 S21 S22 X1 X2 13 F3 F1 F2 Control logic 23 L1 31 A2 SRB 201ZH KB 14 24 32 KA N 3 M LED the integrated LEDs indicate the following operational states. Position relay Position relay The wiring diagram is shown with guard doors closed and in de-energised condition. 2-27