This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows:

Similar documents
2 Unit Petrol Engine Spare parts kits for 4 WD Nissan Patrol

Schedules 1 to 4, Lot B: Extension of the Lessos Substation

NEPAL ELECTRICITY AUTHORITY (A Government of Nepal Undertaking)

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Operation and maintenance of 11kV, 33kV and 220 kv Substation.

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

SF 6 gas insulated RMU SafePlus 24 kv. ABB SafePlus 24 kv SF6 gas insulated RMU 1

COMPACT SUBSTATION GUIDE

Burns & McDonnell ISU Senior Design Project 2010/2011

Distribution transformers Efficiency over life-cycle

ABB Ltda. HEADOFFICE - OSASCO Av. dos Autonomistas, 1496, Vila Campesina Osasco/SP Brazil (Sites in Annex) Standards.

UniPack compact secondary substations (CSS) upto 36 kv For safe, reliable and space saving power distribution solutions

University of Houston Master Construction Specifications Insert Project Name

INESING srl. MOBILE SUBSTATIONS Energy Solution. Energy Innovation. INESING srl Energy Innovation

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

SWITCHGEAR DIVISION PRODUCT PROFILES

SUBSTATIONS. Energy Storage System

INVITATION TO TENDER MR 84/2016. SUPPLY and Install 110V DC BATTERY BANKS and CHARGERS for Rarawai, Sabeto and Lautoka Switching Station

September 2008 TEC, INTELLIGENT MONITORING SYSTEM

132/11 kv, 25 MVA MOBILE SUBSTATION

Modular medium-voltage switchgear. NorMax

Key features. DESIGNS: - Conservator type - Hermetically sealed

(A Government Company) CENTRAL WORK SHOP KOTHAGUDEM

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

GUIDE TO MAINTENANCE PRACTICES FOR DISTRIBUTION NETWORKS IN THE DISTRIBUTION SECTOR OF THE NAMIBIAN ELECTRICITY SUPPLY INDUSTRY

Metal Clad Switchgears

MESG 12 / 17.5 / 24 / 36 KV

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

PRAGATI ENGINEERING COLLEGE

CGMCOSMOS. Reliable innovation. Personal solutions. Fully gas insulated modular and compact (RMU)system.

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal) Project Management Directorate

V. Design, Application, Maintenance & Operation Technical Requirements

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

NEXT STEP B) SAFETY :

ZX-Family Gas-insulated medium voltage switchgear

Product Specification Guide. Title: Southern States 362 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

Low-voltage switchgear MNS Light W. Installation, handling and operation. ABB LV Systems

CLIENT: PROJECT: PO#: ESTIMATOR:

Horns Rev 3 & Kriegers Flak Platform Interfaces

ELECTRIC TRACTION.

SECTION V SWITCHBOARD I 4 Engine/Gen Control Cubicles II 1 Synchronizing System III 1 Ground Detection Network IV 1 600V Feeder Section V 2

TECHNICAL SPECIFICATIONS OF PCC PANEL

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

SPECIFICATION FOR BATTERY & BATTERY CHARGER (D.C. SYSTEM)

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

CPG.0 Single busbar gas-insulated cubicles

Publication No.: PSG

Medium Voltage Metal-Enclosed Switches

Product Specification Guide. Title: Southern States 72 kv RLSwitcher Vertical Interrupter Style Reactor Switcher

B kv Gas-insulated Substations

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

PUB NLH 174 Island Interconnected System Supply Issues and Power Outages Page 1 of 4

NEPAL ELECTRICITY AUTHORITY (An Undertaking of Government of Nepal)

Air-insulated switchgear UniGear type ZS1

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

Power Products Division. Power Services Service underpins everything we do

36kV Gas Insulated Medium Voltage Switchgear

LIST OF EDD DESCRIPTION/ SPECIFICATION AS 19 TH OCTOBER 2016

Product catalogue. ABB AS, Power Products Division SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus 36

INSTALLATION INSTRUCTIONS

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

University of California, San Diego Cal (IT) 2 Technical Assignment #2. Brian Smith

Title Electrical Technical Maintenance Coding System. Reference Number PMP 01 (RIC Standard: EP SP)

IEEE Guide for the Design of Low Voltage AC and DC Auxiliary Systems for Substations

Transformers for Power Applications

CENTERLINE 2500 Low Voltage Motor Control Centers and Switchgear Assemblies

SF 6. -insulated Ring Main Unit, SafeRing 36 and -insulated Compact Switchgear SafePlus kv ABB

Fuji Electric. Oil immersed. Transformer FTU08A1-E-0024

BHARAT HEAVY ELECTRICALS LIMITED, JHANSI

Section S7 - DC and AC auxiliary services installations

Circuit Breaker Prepared By :

56-SDMS-07 REV. 01 SPECIFICATIONS FOR

USN. Metal-clad type switchgear. Technical information

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

Motor-drive mechanisms, type BUL Spare parts list

TECHWARE is partner of CONSORZIO ITALIA 2000 (CI2000) Leader in the world for the HHV/HV overhead lines TCW and CI2000 a global

General Specification and Technical Requirement of 45 MVA 132/33kV Mobile Substation

SF 6 Gas Insulated Switchgear Type SDH714 for 72.5 to 145 kv

Unified requirements for systems with voltages above 1 kv up to 15 kv

TENDER DOCUMENT. (TENDER No: NRO/CON/696/660) FOR

Neart na Gaoithe Meet the buyer event. Chris Whitehead Facilitator

Section 7 Technical Specification of "Design, Supply, Erection, Installation, Testing and Commissioning 33/11KV AIS Substation on Turnkey Basis Under

SPECIFICATIONS FOR 220KV OUT DOOR CIRCUIT BREAKERS. The networks are mainly of outdoor type. The basic parameters are set out below:

Transformer Protection

IM /2017 REV01 POWER WAVE S700 CE

500 kva Pad Mount Transformer V Delta Primary - 208Y/120 Secondary - NEMA 4X - Oil Cooled

voltage switchgear ZX ABB ZX Family 1

Medium Voltage Metal-Enclosed Switches

A 500kV AIS Switchyard Rejuvenation in British Columbia using Hybrids

Syllabus for the Trade of Electrician Duration : Six Month Second Semester Semester Code: ELE: SEM II

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

Single-Phase Step Voltage Regulators

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

AN ISO 9001 & COMPANY TENDER DOCUMENT. TENDER No: DLI/CON/696/411 FOR

MESP TECHNICAL SPECIFICATION FOR A STATIONARY CONTROL BATTERY AND CHARGER SET FOR USE IN A SUBSTATION

ATR-MIX. METAL ENCLOSED SWITCHGEAR kV A ka

Transcription:

This tender addendum and clarification forms part of the Request for Proposal and Contract documents, and modifies them as follows: I. ADDENDUM Isinya Mandatory Spares list Description Quantity A AIS 400kV Circuit breaker 1 Single phase breaker pole 1 2 Operating mechanism 1 3 Density switch 1 4 Trip coils 1 5 Closing coils 1 6 Set of O rings for gas circuit 1 7 Gaskets 1 set 1 B AIS 220kV Circuit breaker 1 1 Single phase breaker pole 1 2 Operating mechanism 1 3 Density switch 1 4 Trip coils 1 5 Closing coils 1 6 Set of O rings for gas circuit 1 7 Gaskets 1 set 1 C Power transformers 1 Buchholz relay 1 2 Silica gel breather 1 3 Primary side phase bushing complete with gaskets 1 4 Secondary side phase bushing complete with gasket 1 5 Primary and secondary neutral bushing complete with gasket 1 6 Replacement for each part likely to be damaged upon operation of the pressure relief relay operation of each transformer 1 7 Motor for each on load tap changer 1 8 Set of contact for each load tap changer 1 9 Dial type thermometer 1 10 Thermostat 1 11 Winding temperature indicator 1 12 Oil temperature indicator 1 D Disconnectors and Earthing switches 1 400kV Complete unit with earthing switch 1 2 220kV Complete unit with earthing switch 1 3 400kV operating mechanism 1 4 220kV operating mechanism 1 2

5 Three pole set of moving contact 400kV disconnector 1 6 Three pole set of fixed contact 400kV disconnector 1 7 Three pole set of moving contact 220kV disconnector 1 8 Three pole set of fixed contact 220kV disconnector 1 E Instrument transformers and Surge arrestors 1 Spare 400kV current transformer 1 2 Spare 220kV current transformer 1 3 Spare 400kV capacitor voltage transformer 1 4 Spare 220kV capacitor voltage transformer 1 5 Spare 400kV metering unit 1 6 Spare 220kV metering unit 1 7 Spare 400kV surge arrestor 1 8 Spare 220kV surge arrestor 1 9 Secondary fuses for 400kV and 220kV current transformers 6 10 MCBs for 400kV and 220kV voltage transformer 6 F Transmission cables 1 220kV cable 3 x 100m 2 Cable termination 2 3 Complete cable repair joint 2 G Post insulators 1 400kV post insulators 2 2 220kV post insulators 2 H SF6 gas accessories 1 Vacuum pump set for evacuation 1 2 SF6 gas cylinder 11kg 3 3 Trolley 1 4 Gas leak detector (portable type) 2 5 Gas filling equipment 1 I Protection relays 1 Distance protection relay 1 2 Line differential protection relay 1 3 Transformer differential protection relay 1 4 Transformer overcurrent protection relay 1 5 Trip circuit supervision relay 1 6 Busbar protection relay 1 J Control equipment 1 Indication lamps of each type 3 2 Ammeters 1 3 Voltmeters 1 4 Megawatt meter 1 5 Megavar meter 1 3

6 Current transducer 1 7 Voltage transducer 1 8 Watt transducer 1 9 Var transducer 1 10 Key operated discrepancy control switch for circuit breaker 2 11 Discrepancy switch for disconnector and circuit breaker 2 12 Annunciator/ alarm units 1 13 Digital display of transformer tap changer position indication 1 14 Push buttons 2 15 Two position selector switch 1 16 Energy meters 1 17 Bay control units 1 18 Ethernet switches 1 19 Operator workstation 1 K Auxiliary voltage accessories (LVAC) 2 Fuse and links of each type and ratings used 2 3 Auxiliary relays of each type used 1 4 MCCBs of each type used 2 7 Main incomer circuit breaker 1 L 110V distribution board 2 Indication lamps 1 3 Fuses and links pairs 3 4 Auxiliary relays of each type used 1 7 MCCBs of each type used 3 M 48V distribution board 2 Indication lamps 1 3 Fuse and links of each type and ratings used 3 4 Auxiliary relays of each type used 1 7 MCCBs of each type used 3 N Fibre optics equipment and Telephone exchange 1 Each type of STM cards used 2 2 Each type of Teleprotection equipment cards used 2 3 Telephone cable 20m 4 Fibre optic splicing kits and consumables 1 4

5 Telephone sets 2 6 SAS/ SCADA module for each of the different cards offered 1 7 Fiber optic approach cable drum 6km O Miscellaneous 1 DC lamps for control room emergency switching 6 2 Substation/ switchyard lighting which shall include: a. Lamps of each type and power used 6 b. Lamp fittings for each type of lamps used 6 3 Maintenance tools with: a. Electrical maintenance tool box 3 b. Mechanical maintenance tool box 3 4 Warehouse 1 Isinya Substation Warehouse At Isinya Substation a store with a usable space area of 1600 square metres will be built. The store shall be appropriately partitioned by the Contractor to the approval of the Employer. This partitioning shall take into consideration that a forklift shall be used for moving the material/equipment. The store should be well ventilated and with sufficient air circulation. 5