CITY OF NEWPORT NEWS - WATERWORKS APPLICATION FOR HYDRANT METER ASSEMBLY & SERVICE PERMIT

Similar documents
DIVISION VI FINANCIAL MATTERS HYDRANT METER ACCOUNTS

City of Durango Hydrant Use Policy

SACRAMENTO REGIONAL SOLID WASTE AUTHORITY (SWA)

ORDINANCE NO

LCWSD Fax Number - (803) Hydrant Use Policy

Environmental Health Department

GENERAL PLAN APPROVAL AND GENERAL OPERATING PERMIT BAQ-GPA/GP 2 STORAGE TANKS FOR VOLATILE ORGANIC LIQUIDS

SYNOPSIS OF PROPOSED GEORGIA DEPARTMENT OF PUBLIC SAFETY RULES CHAPTER TRANSPORTATION NETWORK COMPANIES AND TAXI SERVICES

COMMISSIONERS OF PUBLIC WORKS. of the CITY OF CHARLESTON, SOUTH CAROLINA

PARKING RULES & REGULATIONS 1201 WILSON AVENUE, TORONTO, ONTARIO

DRIVER QUALIFICATION FILE CHECKLIST

CITY OF DENTON TRANSPORT TRUCK DISCHARGE PERMIT AGREEMENT. January 1, 2019 through December 31, 2019

Parking Regulations. General Provisions

Dealer Registration. Please provide the following:

Instructions for Submittal of a Annual On-Street Valet Parking Permit

If no, please give name, address & phone number of the operator:

REQUEST FOR PROPOSALS FIRE HYDRANT MAINTENANCE SERVICES

Instructions for Submittal of a Annual On-Street Valet Parking Permit

Policies and Procedures Handbook Procedure No.: T.2 Illinois Institute of Technology Date of Issue: 7/11

City of Ely Golf Cart/ATV Registration

Vehicle Make/Model Vehicle Year/VIN # Vehicle Color

CHARLES RIVER POLLUTION CONTROL DISTRICT. Requirements for Septage Receiving

COUNTY OF RIVERSIDE, CALIFORNIA BOARD OF SUPERVISORS POLICY. Policy Subject: Number Page OVERNIGHT RETENTION OF COUNTY VEHICLES D-10 1 of 5

TITLE 15 MOTOR VEHICLES, TRAFFIC AND PARKING 1 CHAPTER 1 MISCELLANEOUS

CITY OF STURGIS TITLE 37-1 TITLE 37 CITY TRANSIT

GREATER VANCOUVER SEWERAGE AND DRAINAGE DISTRICT BYLAW NO. 307, A Bylaw to License Commercial Waste Haulers

CHAPTER 1-7 ARTICLE V AN ORDINANCE PERMITTING AND REGULATING THE OPERATION OF GOLF CARTS ON PUBLIC STREETS

GENERAL ASSEMBLY OF NORTH CAROLINA SESSION 2017 H 2 HOUSE BILL 469* Committee Substitute Favorable 4/24/17

APPLICATION for BUSINESS LICENSE Licensing & Permits City of Williston PO Box 1306, Williston, ND

Forensic Sciences Chapter ALABAMA DEPARTMENT OF FORENSIC SCIENCES ADMINISTRATIVE CODE CHAPTER IGNITION INTERLOCK RULES

CHAPTER 12 TOW TRUCKS

ORDINANCE NO. AN ORDINANCE AMENDING CHAPTER 75 ALL-TERRAIN VEHICLES AND SNOWMOBILES

City of Gainesville Public Utilities Department Backflow Prevention Program

Parking Regulations. Responsibility

APPLICATION FOR EMPLOYMENT

SANDAG Vanpool Program Guidelines as of February 2018

New Jersey Motor Vehicle Commission

CHAPTER 37. BE IT ENACTED by the Senate and General Assembly of the State of New Jersey:

IGNITION INTERLOCK SERVICE CENTER RENEWAL LICENSE

CYPRESS FALLS HIGH SCHOOL

Regulation for the organization and functioning of the paid underground parking system of the commercial center BĂNEASA SHOPPING CITY PREAMBLE

IC Chapter 6. Commercial Driver's License

CITY OF PLACENTIA RESIDENTIAL PERMIT PARKING PROCEDURES AND GUIDELINES 2017

PERU STATE COLLEGE Parking and Traffic Regulations 2017/2018 School Year (Subject to change due to construction projects)

CHAPTER 20.1 WASTEWATER HAULING. Section Definitions. For the purposes of this article, the following definitions shall apply:

SECTION ONE: ADMINISTRATION AUTHORITY PARKING REGULATIONS DISABLED PARKING PARKING CITATION AUTHORITY...

5 Year / 160,000 km (100,000 mi) ** 1 Year / 30,000 km (19,000 mi) 3 Year / 100,000 km (62,000 mi)

Rancho Villas Community Association Vehicle & Parking Rules and Regulations

As Introduced. 132nd General Assembly Regular Session S. B. No

Bevill State Community College Transportation Policy

Chapter 257 VEHICLES AND APPLIANCES, ABANDONED AND JUNKED

To facilitate the extension of departmental services through third party testing organizations as provided for by CRS (b)

City of, Kansas Electric Department. Net Metering Policy & Procedures for Customer-Owned Renewable Energy Resources

Please answer all questions. If the answer to any question is "No" or "None", do not leave blank, but write "No" or "None.

GENERAL ASSEMBLY OF NORTH CAROLINA 1991 SESSION CHAPTER 530 HOUSE BILL 516

CITY OF SAN GABRIEL ALL-NIGHT PARKING APPLICATION

ABANDONED VEHICLES; DEFINITIONS.

H 7790 S T A T E O F R H O D E I S L A N D

DRAFT CITY OF LONSDALE NEW PROPOSED ORDINANCE CHAPTER 73: MOTORIZED GOLF CARTS

RULES OF THE DEPARTMENT OF PUBLIC SAFETY. Chapter Non-Consensual Towing

APPLICATION FOR USE OF GOLF CART AND UTILITY-TERRAIN VEHICLE. Owner s Name: Physical Address: Mailing Address: Phone #: Driver s License #:

Policy Resolutions #5 (Amended 4/3/13)

TERMS AND CONDITIONS

AIR QUALITY PERMIT. 7 Foundation Drive Savannah, Georgia (Chatham County)

Santa Rosa City Code. TITLE 11 VEHICLES AND TRAFFIC Chapter RESIDENTIAL PARKING PERMITS Legislative purpose.

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

CITY OF ESCONDIDO Planning Division 201 North Broadway Escondido, CA (760) Fax: (760)

RESTRICTIONS ON PARKING; POSTED LIMITATIONS.

Colt Series C400, C500

A P P L I C A T I O N F O R

Louisville Gas and Electric Company

BUSINESS POLICIES AND PROCEDURES MANUAL Revised 9-17 Accounts Payable

HOUSE BILL NO. HB0128

MANUAL OF ISSUANCE OF SPECIAL HAULING PERMITS ON WARREN COUNTY HIGHWAYS. Effective March 17, 2015 Revised January 2, 2018

DRIVER QUALIFICATION FILE CHECK LIST

CITY of ALBUQUERQUE TWENTY-FIRST COUNCIL

Electric Vehicle Charging Station Incentives PROGRAM HANDBOOK

West Virginia Motor Vehicle Laws

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

BUSINESS POLICIES AND PROCEDURES MANUAL Revised 9-17 Accounts Payable

Owner s Manual GLASSLINED PUMP TANK

(a) Administrator means Clearwater's Public Works Administrator or his or her designee.

Prospector Square Property Owners Association Parking Rules & Regulations SECTION 1- GENERAL

Los Angeles County Metropolitan Transportation Authority Permit Parking Terms and Conditions

Municipality Generator Interconnection Application Single Meter Application Part I

Public Service Company of Colorado THE SOURCE TO WHICH THIS PERMIT APPLIES IS DESCRIBED AND LOCATED AS FOLLOWS:

City of Washington, Kansas Electric Department. Net Metering Policy & Procedure For Customer-Owned Renewable Energy Resources

CHAUTAUQUA COUNTY DISTRICT ATTORNEY S TRAFFIC SAFETY PROGRAM

The Premcor Refining Group, Inc. Delaware City Refinery 4550 Wrangle Hill Rd. EXHIBIT A Delaware City, DE 19706

Frazeysburg Police Department

CHAPTER 22 SOLID WASTE AND RECYCLABLE COLLECTION. (with amendments through )

The APR Plus limited powertrain warranty has coverage that matches the term of your factory powertrain warranty.

Installation Manual DIAPHRAGM WELL TANK

Ports of Delaware and Virginia (DE-VA)* Dray Truck Replacement Program Application

WARRANTY REGISTRATION FORM

CITY OF SALEM, ILLINOIS ALTERNATIVE TRANSPORTATION APPLICATION AND INSPECTION REPORT (GOLF CARS) Applicant Name:

THE UNIVERSITY OF SCRANTON VEHICLE OPERATOR POLICY

Applicant Information All spaces must be filled in. Applications with blank spaces will be rejected.

CHAPTER 4. Abandoned or Junked Vehicles

MAIA and the Registry of Motor Vehicles May 12, 2017

Transcription:

CITY OF NEWPORT NEWS - WATERWORKS APPLICATION FOR HYDRANT METER ASSEMBLY & SERVICE PERMIT A Hydrant Meter Assembly (HMA) and Hydrant Meter Service Permit will be issued for water service not intended for ingestion only after [1] a genuine need has been established by completion of this form, [2] approval of proposed use is granted by Waterworks, and [3] applicant has paid all applicable fees & deposits. Subsequent to applicant s submittal of this form, Waterworks will determine approval or denial within three (3) business days and will then notify applicant of response. Applicant must be an officer (i.e., person authorized to approve financial commitments) of the requesting company or organization. PART I: TO BE COMPLETED BY APPLICANT Please Print, Except For Signature Applicant s Name Title Name of Company or Organization Street Address City or Town State Zip Code Federal Tax ID No. or SSN Telephone ( ) Fax ( ) Local Telephone ( ) Proposed Use of HMA (be specific) Location of HMA Use Vehicle-Mounted Anticipated Duration of Use (from) (to) (1 year max) [NOTE: Permit is valid for period of one (1) year beginning at date HMA is issued; use of HMA beyond this time frame will require application for a new permit.] I have read the Hydrant Meter Service Permit, agree to comply, and hereby apply for a Hydrant Meter Assembly and Hydrant Meter Service Permit for the stated purpose. Applicant s Signature Date PART II: TO BE COMPLETED BY WATERWORKS METER SHOP Application is: Approved for HMA size 1 3 or Denied Reviewer s Signature Date Form No. NNWW-HMA-01 July 2016

HYDRANT METER ASSEMBLY RECORD The data recorded herein is to document the approved use of a hydrant meter assembly. A copy of the approved application is attached. Hydrant Meter Service Permit: Permit No. Date Hydrant Meter Assembly Issue: Account No. Issue Date Meter Serial No. Meter Reading at Issue RPZ Serial No. Latest RPZ Test Date Vehicle-Mounted HMA: PART I: TO BE COMPLETED BY METER SHOP Approved Air Gap: Yes No Latest Insp Date Truck No. Waterworks Representative (Signature) Applicant s Representative (Signature) Hydrant Meter Assembly Return: Return Date Meter Reading at Return Condition of HMA is same as at issue: Yes No (describe below) Waterworks Representative (Signature) PART II: TO BE COMPLETED BY WATERWORKS ACCOUNTING Accounting Control No. Deposit Amount $ Cut-Off Date Vendor No. Date Final Bill Paid Remarks Form No. NNWW-HMA-02 July 2016

HYDRANT METER ASSEMBLY VIOLATIONS This document is a record of observed violations involving a hydrant meter assembly issued for use in accordance with the Hydrant Meter Service Permit identified on the other side. Permit No.: Meter Serial No.: 1 st Violation: Date: Time: Hydrant No. Location: Description: Action/Comment: Reported by: Recorded by: 2 nd Violation: Date: Time: Hydrant No. Location: Description: Action/Comment: Reported by: Recorded by: 3 rd Violation: Date: Time: Hydrant No. Location: Description: Action/Comment: Reported by: Recorded by: Form No. NNWW-HMA-02 July 2016

HYDRANT METER SERVICE PERMIT Permit No. Meter Size 1 3 Issue Date This permit is hereby issued to to allow use of a hydrant meter assembly for the purpose of. Vehicle-mounted General: Use of a hydrant meter assembly (HMA) and a hydrant meter service permit is pursuant to an applicant receiving approval, agreeing to the conditions of the permit, and complying with those conditions. An HMA is defined as a water meter, a reduced pressure principle backflow preventer (except for vehicle-mounted meters with a permanent air gap arrangement), appropriate fittings & valves, and a hydrant wrench. A hydrant meter service permit is valid for one (1) year beginning at date hydrant meter assembly is issued; use of the HMA beyond this time frame will require application for a new permit. Use & Restrictions: Water obtained from a fire hydrant is NOT intended for ingestion by humans or animals, and Waterworks assumes no liability for such use. A hydrant meter assembly must be used at all times whenever water is drawn from a fire hydrant, and all water drawn from a hydrant must pass through an HMA. Hydrant meter assemblies issued by Newport News Waterworks are to be used only on fire hydrants that are owned & maintained by Newport News Waterworks. They are not to be used on private fire hydrants or on hydrants in jurisdictions not served by Newport News Waterworks. NOTE: Fire hydrants that are owned & maintained by Newport News Waterworks are easily identified by an Arabic numeral or series of numerals stamped into the top surface of each hydrant s operating nut. In addition, these hydrants are painted red, with white paint on the bonnet and nozzle caps although, not all fire hydrants painted with this scheme are the Waterworks hydrants. Use of hydrant meter assemblies (or any portion thereof) obtained from a source other than Newport News Waterworks Meter Shop will not be allowed. Only wrenches specifically designed for use on fire hydrants are to be used for removing/replacing nozzle caps, and for operation of the hydrant s operating nut use of anything other than a hydrant wrench will be considered a violation of this permit. If a hydrant meter assembly is attached directly to a fire hydrant nozzle, a rigid means of support must be provided to minimize the weight borne by the nozzle and/or coupling on the HMA. The hydrant meter assembly must be disconnected from the fire hydrant from which water is being drawn at the end of each normal workday. No fire hydrant is to be left in a condition that would impede access for emergency use. Form No. NNWW-HMA-03 July 2016

In the event of a water supply emergency, as determined by the Waterworks Director, all hydrant meter service permits will be reviewed for possible suspension for an unspecified period of time. The period of validity for all suspended permits will be extended for an amount of time equal to the suspension. Use of an HMA during a permit suspension may result in confiscation of HMA. Deposits & Fees: Subsequent to approval of application for a hydrant meter assembly and prior to issuance of the HMA & hydrant meter service permit, the following financial obligations must be paid: NOTE: All applicable deposits & fees must be remitted in the form of a check or money order made payable to Waterworks 1. A non-interest bearing security deposit in the amount of $390.00 [1 meter with backflow preventer], $855.00 [3 meter with or without backflow preventer. 2. A turn-on fee (to initiate the account) in the amount of $50.00 A monthly service fee of $42.00 [1 meter] or $160.00 [3 meter with or without backflow preventer] will be assessed during time permit holder has possession of the HMA, regardless of consumption. Applicant s HMA account will be charged the applicable water consumption rate, in effect at time of use, for all metered water. A permit holder will be required to read the meter between the 1 st & 10 th of each month and report the reading to Waterworks Auditing [call: 926-1163 or fax: 926-1168 or e- mail: wwauditing@nnva.gov]. Meter dials register water consumption similar to a vehicle s mileage odometer read (left to right) & report ALL digits, including ALL ZEROS. A no-read fee in the amount of $25.00 will be assessed to each account for each month that a reading is not reported. The cost of any damage to the HMA and/or hydrant(s) as the result of misuse or improper care, whether incidental or intentional, will be charged directly to the applicant, and if not paid it will be deducted from the security deposit. All charges, including those for damage, assessed to the applicant must be paid in full before the security deposit will be returned to the applicant. All outstanding fees assessed to any account in the applicant s name, or the name of the company or organization requesting an HMA must be satisfied prior to issuance of this permit. Maintenance & Testing: It is the responsibility of the permit holder to maintain the hydrant meter assembly in the same condition that existed at time of issue. All HMA s (including vehicle-mounted air-gaps) are not to be altered or tampered with in any fashion; evidence of such will be a violation of this permit and could result in suspension of hydrant use privileges; this is not to preclude the addition of fittings downstream of the HMA. The HMA shall be returned to the meter shop when: a. It is no longer needed by the permit holder b. A period of one (1) year from issue date has passed Form No. NNWW-HMA-03 July 2016

i. Vehicles with mounted HMA s must be presented for air gap inspection c. The assembly is recalled by the Waterworks All hydrant meter assemblies must be returned to Waterworks meter shop at 425 Industrial Park Drive, Newport News upon notification by the meter shop. Enforcement & Penalties: The Waterworks meter shop will maintain a record of all reported violations observed in the field and will take appropriate action, as follows: The first violation will result in a verbal warning to the permit holder and to the applicant A second violation will result in a verbal warning to the permit holder and a written notification to the applicant informing him/her of the two (2) violations and the consequences of a third violation. A third violation will result in revocation of the hydrant meter service permit and recall of the hydrant meter assembly Revocation of a hydrant meter service permit, for any reason, will result in: Forfeiture of all deposits on the subject account Ineligibility of company or organization represented by permit holder to obtain another permit for a minimum of six (6) months, unless approval is granted by Waterworks Director or his representative. The revocation of a second hydrant meter service permit, within 24 months, issued to the same company or organization will result in permanent ineligibility. TO BE COMPLETED BY PERMIT HOLDER: Please Print, Except For Signature Name (Current Photo-Identification Required) Representing (company or organization) I have read and understand the above requirements, and hereby agree to comply with these requirements in the use of a Hydrant Meter Assembly and Hydrant Meter Service Permit for the stated purpose. Furthermore, I understand that violation of any of these requirements could result in penalties, loss of this permit and hydrant meter use privileges. Signature Date TO BE COMPLETED BY METER SHOP: Waterworks Representative (Signature) A COPY OF THIS PERMIT MUST BE ON SITE Form No. NNWW-HMA-03 July 2016

Report all problems with fire hydrants to 757-234-4913 Hydrant Meter Assemblies are issued to companies/organizations to accommodate their stated need(s) for water; however, you are reminded that the primary purpose of all fire hydrants is for emergency use please do not abuse this privilege by impeding access to any hydrant. NOTE: Only wrenches specifically designed for use on fire hydrants are to be used for removing/replacing nozzle caps, and for operation of the hydrant s operating nut Any fire hydrant to which a hydrant meter assembly will be connected shall be operated in the following manner: 1. Verify that the hydrant is closed before removing any nozzle caps 2. Remove and securely store nozzle cap 3. Flush hydrant by allowing a slow flow until clear 4. Attach hydrant meter assembly to hydrant nozzle and provide adequate support blocking DO NOT OBSTRUCT VENT PORT ON RP Maintain a minimum of 12 clearance between vent port and closest object/ground. 5. Verify outlet shut-off valve of hydrant meter assembly is closed 6. SLOWLY open (turning counter-clockwise) hydrant operating nut until hydrant is fully open 7. SLOWLY open hydrant meter assembly outlet shut-off valve use this valve to control flow during working hours At the end of each normal workday, the hydrant meter assembly shall be disconnected from the fire hydrant in the following manner: 1. Verify that hydrant meter outlet shut-off valve is closed 2. SLOWLY close (turning clockwise) hydrant operating nut until hydrant is fully closed 3. Open HMA outlet shut-off valve and drain HMA 4. Disconnect hydrant meter assembly from fire hydrant 5. Replace nozzle cap on fire hydrant nozzle 6. Secure hydrant meter assembly to avoid unauthorized use or theft DIAL 1 HMA DIAL 3 HMA Meter dials register water consumption similar to a vehicle s mileage odometer read (left to right) & report ALL digits, including ALL ZEROS. Form No. NNWW-HMA-03 July 2016

HYDRANT METER ASSEMBLY HMA 3 2a 2b 1 2 Do NOT Obstruct Vent Port on RP Min 12 Above Ground ITEM NO. DESCRIPTION 1 Water Meter 2 Reduced Pressure Principle Backflow Preventer 2a 2b Ball Valve (inlet) Ball Valve (outlet) Operate For Flow Control 3 Hydrant Wrench Furnished by Waterworks This diagram illustrates a 3 Hydrant Meter Assembly as issued by meter shop, and its proper installation. A 1 HMA is similar and is equipped with a male pipe thread x male garden hose thread adapter on the outlet valve.

TYPICAL PERMIT VIOLATIONS Violations of a Hydrant Meter Service Permit include, but are not limited to, the following: Hydrant Meter Assembly (HMA) attached directly to a fire hydrant without any support, or with inadequate support (e.g., support is present but HMA is not actually resting on support). Use of any tool other than a hydrant wrench to remove/install nozzle cap or to operate hydrant. HMA used for any purpose other than that specified on the application. Disassembly or alteration of the HMA. Piping attached to outlet of HMA that would prohibit or interfere with removal of HMA from hydrant. Obstruction of vent port on backflow preventer (non-mobile operations) or inadequate air gap (mobile operations). Obstruction of fire hydrant (e.g., box or barrel placed over hydrant). Any activity that has the potential of causing contamination of the Waterworks distribution system. Failure to comply with operating instructions (e.g., partially-opened hydrant) Leaking connections (waste of water and/or potential hazard to traffic/pedestrians) Unattended HMA (i.e., user should be within the general vicinity of the hydrant & HMA).