LGH-8RX3 VOLUME SIGN Control signal Heat recovery system Heat recovery module material Cladding Heat insulating material Motor Blower Filter material Operating environment (Supply air) Functions Weight Serial single communication (M-NET transmission) Air-to-air total heat (sensible heat + latent heat) recovery Partition, spacing plate-special treated paper Galvanized steel sheet Self-extinguishing urethane foam Totally enclosed capacitor permanent split-phase induction motor, 4 poles, 2 units 245 mm dia.centrifugal fan Non-woven fabrics filter (Gravitational method 82%) - C to 4 C, RH 8 % or less (-5 C (*) to +4 C, RH 8 % or less) Lossnay ventilation/bypass ventilation ()- switching 6 kg Power supply Single phase 22-24 V/5 Hz Single phase 22 V/6 Hz Ventilation mode Lossnay ventilation Bypass ventilation Lossnay ventilation Bypass ventilation Fan speed Current [A].8-.8.7-.7.4-.4.7-.7.6-.6.4-.4 2..9.5 2..8.4 Power consumption [W] 392-48 368-396 34-332 37-394 348-374 298-33 455 45 35 425 39 35 Air volume [m 3 /h] [mmh2o] 8 4.3 8.2 67 7. 8 4.3 8.2 67 7. 8 23.5 8 2.2 66 8.2 8 23.5 8 2.2 66 8.2 [L/s] [Pa] 4 86 7 4 86 7 23 2 83 8 23 2 83 8 Temperature recovery efficiency [%] 78 78 8.5 - - - 78 78 8 - - - Heating 7 7 73 - - - 7 7 73.5 - - - efficiency (%) Cooling 64.5 64.5 68 - - - 64.5 64.5 68.5 - - - Noise (db) Measured at.5 m under the center of panel 33.5-34.5 32-33 3-3 34.5-35.5 33-34 3.5-3.5 35 3 29 36 32 29.5 Air outlets 44.5-45.5 43-44 4-4 45.5-46.5 44-45 4.5-4.5 46 42 39 47 43 39.5 Starting current Insulation resistance Dielectric strength Under 3.8/3. A or less MΩ or more (5 V megger) AC 5 V minute Characteristic Curves Recovery efficiency (%) 9 Recovery efficiency (%) 5 Hz 6 Hz 9 8 Temperature recovery efficiency efficiency (Heating) 8 Temperature recovery efficiency efficiency (Heating) 7 5 5 7 5 5 efficiency (Cooling) 6 5 (mmh2o) 4 3 2 (Pa) 4 3 2 efficiency (Cooling) 2 4 6 8 2 (m 3 /h) 25 mm dia pipe length m 8 m 6 m 4 m 2 m 5 5 2 25 3 35 Air volume (L/s). The defrosting mode must be operated under - C or below. (Air supply fan drives 6 min. ON/ min. OFF) 2. The current, power consumption and efficiency are based on the above air flow rate. 3. The noise at the air outlets is the values at a 45 angle,.5 meters in front of the unit. 4. Fan speed can be switched between high and low. The main unit switch must be used to select the fan speed. 6 5 (mmh2o) 4 3 2 (Pa) 4 3 2 2 4 6 8 2 (m 3 /h) 25 mm dia pipe length m 8 m 6 m 4 m 2 m 5 5 2 25 3 35 Air volume (L/s) SPECIFICATIONS 7-Jun.- LGH-8RX3 NUMBER No. ND66 /4
Drawings and Dimensions Position where duct direction is changed 49 Air exhaust fan Damper plate 3 Ceiling suspension fixture EA (exhaust air) RA (return air) OA (outside air) SA (supply air) 9 Maintenance space for heat exchanger, air filters, and fans 6 or more 5 to 25 Air supply fan Control box 398 Maintenance cover Heat exchanger (Lossnay core) -performance filter (sold separately attachment position) 79 64 79 Position where Ceiling suspension 49 ( fixture is changed ) φ 242 φ 258 4 69 36 49 Inspection opening 22 Power cord opening Ceiling suspension fixture Air filters UNIT mm SCALE N.T.S. If condensation is expected to form, heat up the fresh outside air using a duct heater, etc. 2. An inspection port (45 45 6 6 mm) must be installed on the filters and Lossnay cores removing side. 3. The two outdoor ducts must be covered with heat-insulating material in order to prevent condensation from forming. The two indoor ducts may be covered with heat-insulating if Lossnay is to be installed in the circumstance of higher temperature in summer. 4. Installing the duct damper is preferred also to prevent the outdoor air introduced to room if there has strongthern wind, when the unit operates or stops. 5. The outside ducts must be tilted at a gradient (/3 or more) down toward the outdoor area from Lossnay unit. DRAWINGS AND DIMENSIONS 7-Jun.- LGH-8RX3 NUMBER No. ND66 2/4
Schematic NOTE M2 Supply fan motor M Exhaust fan motor Operation monitor output MAX MIN AC 24 V 2A AC 22 V ma DC 24 V 2A DC 5 V ma Malfunction monitor output MAX MIN AC 24 V A AC 22 V ma DC 24 V A DC 5 V ma. TM, TM2, TM3, TB5 shown in bold lines are field work. 2. Breaker should be provided by the customer. 3. Be sure to connect the grounding wire. CN BLACK YELLOW CN9 5 SW3 C 9 8 7 5 SW4 C TM3 X7 X8 TM2 CN8- X3 X4 X X2 2 3 4 5 6 A B S 2V or 24V DC Mr.Slim (non-polar) 3 Uncharged a-contact RED SW2 SA External control input CN8-2 SW5 SA2 PZ-4SLB ZNR2 DSA Fuse S 25V 6.3A ZNR SW CN32 Transmission cable Lossnay unit MAX 5 units C GREEN/YELLOW CN X5 TB5 3 CN7 6 CN2 CN5 CN6 S2 PZ-52SF RED TM PE N L YELLOW CN6 TR Shield wire TH(OA) TH2(RA) CN6 Breker M-NET-transmission cable N L Power supply 22-24 V ~5Hz 22 V ~6Hz LS GM Unchaged a-contact / select connector. This must be used with Mitsubishi Electric Air-Conditioner Network System. (MELANS) 2. External control input (TM2) is impossible to use on the Lossnay addressed to Sub (SW) unit. 3. PZ-4SLB and PZ-52SF cannot be used simultaneously. Symbol explanation M : Motor for exhaust fan M2 : Motor for supply fan C : Capacitor GM : Motor for Bypass movement LS : Microswitch TH : Thermistor for outside air TH2 : Thermistor for return air SW : Switch (Main/Sub change) SW2, 5: Switch (Function selection) SW3 : /E.high select switch (Exhaust fan) SW4 : /E.high select switch (Supply fan) TM : Terminal block (Power supply) TM2 : Terminal block (Transmission cable and external control input) TM3 : Terminal block (Monitor output) * TB5 : Terminal block (M-NET Transmission cable) S, S2 : Connector (Power supply) TR : Control circuit transformer X7 : Relay contact (For operation monitor output) X8 : Relay contact (For malfunction monitor output) CN : Connector (Transformer primary) CN2 : Connector (Transformer secondary) CN5 : Connector (Thermistor) CN6 : Connector (Microswitch) CN7 : Connector (Motor for Bypass operation) CN8- : Tab connector (Fan motor) CN8-2 : Tab connector (Fan motor) CN9 : Connector (Fan motor) CN : Connector (Fan motor) CN6 : Connector (/ switch) CN32 : Connector (Remote control selection) * SA * SA2 : Address setting rotary switch ( digit) : Address setting rotary switch ( digit) MARK : Indicates terminal block : Connector : Board insertion connector or fastening connector of control board SCHEMATIC 7-Jun.- LGH-8RX3 NUMBER No. ND66 3/4
NC Curves 5Hz Background noise : 25dB or less (A range) Measurement site : Anechoic chamber Operation conditions : Lossnay ventilation.5m Measurement point Octave band sound pressure level (db) 9 8 7 6 5 4 3 2 Extra-high NC-7 NC-6 NC-5 NC-4 NC-3 NC-2 62.5 25 25 5 k 2k 4k 8k Octave band centre frequency (Hz) 6Hz Background noise : 25dB or less (A range) Measurement site : Anechoic chamber Operation conditions : Lossnay ventilation.5m Measurement point Octave band sound pressure level (db) 9 8 7 6 5 4 3 2 Extra-high NC-7 NC-6 NC-5 NC-4 NC-3 NC-2 62.5 25 25 5 k 2k 4k 8k Octave band centre frequency (Hz) NC CURVES 7-Jun.- LGH-8RX3 NUMBER No. ND66 4/4