Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E3_F_-L_WC-HL 1.0

Similar documents
Round or Square Type Non-IC Adjustable Housing with Toroidal Transformer for Flangeless Trims E3_L_-HANM_ 1.7

Round or Square Type Low-Profile Housing with Toroidal Transformer for Flangeless Trims E3_LF-HDSM-WR_ 1.0

4" LED SPECIFICATIONS LOW-PROFILE ADJUSTABLE DOWNLIGHT

D3 INSTALLATION GUIDE

Outdoor Installation Using an Electronic LED Power Supply (TE-60L-12)

2" LED SPECIFICATIONS ADJUSTABLE DOWNLIGHT & WALL WASH

MULTIPLES SPECIFICATIONS 1 X 2 TRIMMED

MULTIPLES SPECIFICATIONS 1 X 4 TRIMMED

CITIZEN CITIZEN WARM DIM XICATO MAX OUTPUT HIGH OUTPUT LOW OUTPUT HIGH OUTPUT LOW OUTPUT STANDARD SERIES ARTIST SERIES

MULTIPLES SPECIFICATIONS 1 X 1 OPEN

3" LED SPECIFICATIONS ULTRA SHALLOW FIXED DOWNLIGHT

2" LED SPECIFICATIONS ADJUSTABLE DOWNLIGHT & WALL WASH

Ivalo Finiré 3 LED Recessed Lighting Installation Instructions

BYOM ELEMENT SPECIFICATIONS BUILD-YOUR-OWN MULTIPLES

Section One: Install the Constant Current DMX Driver

WARM COLOR DIMMING ARTIST SERIES 21º º º º - N/A 43º - N/A 60º K, 3000K or 3500K*** 3000K-1800K Warm Dim

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

Installation Instructions MX LED Enhanced Color Adjustable

A CHANNEL. Installation Instructions for Tie Stix Wall 2-Light. Section One: 4SQ Version

800 TO 9000 LUMEN 8 LED SILENT CEILING DOWNLIGHT HYPERBOLIC OPEN APERTURE L8 SERIES

Avenue B. Grid Mount (Regress Trim Shown) Flush Lens. Drywall Flange (Regress Trim Shown) Narrow 3" slot LED with frosted satin lens.

id + 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

1718 W. Fullerton Ave Chicago, IL Tel: Fax:

id + 4.5" x 4.5" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

Installation Instructions for Monorail 2 Circuit 2 X 250 Watt Sloped Surface Mount Magnetic Transformer 120 Volt Input to 12 Volt Single Feed Output

INSTALLATION INSTRUCTION Aether 2 Shallow Recessed Housing

id + 6" x 6" Downlight mm Trim ChromaSure: Color consistency resulting in a 2-step MacAdam ellipse across the entire ID+ product line.

Customer service: or Upper mounting ring. Canopy

Installation Instructions for Sun 3 RGB LED. Section One: Install the Constant Current DMX Driver

Square Trim Style Reflector Finish Flange Style / Finish Environmnet Ceiling Installation. Available for 3SQD, 3SQWW only. 5

Luminaire PROFILE-SPOKE 15 UP 85 DN LED (PS1-D) Type. Notes. Performance Summary D OPTIONS 3S A 28 W B 34 W C 44 W D 57 W

Installation Instructions 4 Gravity Enhanced Color Adjustable

Project. Comments. Prepared by

SERIES 6VLFL2X Lensed LED Downlight Lumen Flex

Jandy Pro Series WaterColors LED Lights Underwater Large and Small Light

MIRRORLITE RECESSED EMERGENCY LIGHTING

NIOB-2 2" BWF IOLITE TRIMS

INSTALLATION INSTRUCTION Oculux 3.5" Architectural Downlight R3CRN-11, R3CSN-11

TOPAZ 12 WALL PACK INSTALLATION & MAINTENANCE GUIDE (Part # LIT A)

E E VDC COOLEDGE TILE INTERIOR INSTALLATION INSTRUCTIONS. Caution: Observe precautions for handling electrostatic sensitive devices.

NRM2-511 / NRM2-512 / NRM2-518

DMXR DALI. Must specify 120 or 277 volts. Available on EZ1 and EZB only 5. Available on 4ABV and 4DBV only 6. Available on 4AC, 4AC20, 4DP, 4WW only

Asymmetrical Installation Instructions. Components: i2cove Asymmetrical LED Light Fixtures. 12 [305mm] [918mm] 48.

Luminaire PROFILE-SPOKE Ind. Up Dn Control (PS3-B) Type. Project. Notes. Performance Summary OPTIONS 4S D 76 W 3S D 57 W

LIGHTPLANE 1 RECESSED - LP1R

13 3/4" Will expand to 24 3/8" (Reduces to 10 3/4" with breakaway feature) 19 5/8"

32LM 3200 Lumens ECOS2 Lutron Hi-Lume A series 2-wire forward phase, 1% dim. Must specify 120 or 277 volts 5. Available on 24D only 6

SERIES 6LB79V-NF LENSED Lumen Bridgelux LED Recessed Downlight

DIMENSIONS. 13 3/4" Will expand to 24 3/8" (Reduces to 10 3/4" with breakaway feature) 8 15/16" 15 1/8" 19 5/8" IC43N

PROFILE 50 Up 50 Dn PF1-E. Luminaire PROFILE - 50 UP 50 DN LaED (PF1-E) Type. Project. Product. Notes. Performance Summary

INSTALLATION INSTRUCTION W Track Recessed 120V Flangeless

INSTALLATION INSTRUCTION Aether 3.5 Color Tunable LED Downlight

Elle Surface Mounting Instructions

Avenue A. Grid Mount (Open Shown) Drywall Flange (Open Shown) louver lens mr16

Trim Style Reflector Finish Flange Style / Finish Environment Ceiling Installation

QUICK START INSTALLATION GUIDE ANALOG - INTELLIGENT POWER CENTER (IPC)

Project. Comments. Prepared by

ID+ 3.5" x 3.5" 60 cut-off reflector. 50 cut-off reflector. Less than 2.64" low profile housing available.

2000 LUMENS A3-LED. Submittal form is Tel: Fax:

NRM-511 / NRM-512 / NRM-518

Installation Instructions BLTR and 2BLTR Relight Assembly

nissan patrol birfield kit

HIGHBAY RAIL 400W INSTALLATION INSTRUCTIONS

Luminaire PROFILE-SPOKE 40UP 60 DN LED (PS1-A) Type. Notes. Performance Summary OPTIONS CONTROLS

Project name. Qty. Output (nominal lumens) Colour and colour temperature. Optics (nominal distribution) Narrow spot 10, Narrow 20, Medium 40

General Installation Instructions LED

Reflectors are compatible with respective Marquise II series housings manufactured by Nora Lighting.

Avenue B. Narrow 3" slot LED with frosted satin lens. Shielding options include corrugated or solid regressed trim or flush lens.

Installation Instructions MX LED Downlight Remodel

ELS Electronic Lighting System

AquaLumin III - Nicheless Light Installation Guide IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Essenza. Round Downlights

Elle Surface Mounting Instructions

INSTALLATION INSTRUCTIONS

READ AND FOLLOW ALL SAFETY INSTRUCTIONS! SAVE THESE INSTRUCTIONS AND DELIVER TO OWNER AFTER INSTALLATION.

Skydome. 2', 3' and 4' diameter recessed direct LED with lens. Frosted acrylic diffuser provides high transmission and uniform distribution.

Output (nominal lumens) 700 lm, 1000 lm, 1300 lm, 2000 lm, 3000 lm, 4000 lm, 5000 lm. Color and color temperature

LED IMPORTANT SAFETY INSTRUCTIONS

95+ CRI 90+ CRI 95+ CRI. Product Watts Color Temp CRI Version Driver Optional. 3G 3rd Gen

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

6" LED Downlight LC6LED 120 or 277V 0-10V Dimming Option

BLACK BODY DIMMING 800/1300/1500 LUMEN 6 LED NEW CONSTRUCTION/REMODEL

SERIES 6LCDB79V Low Voltage LED Downlight

UV8 & UV90 SERIES INSTALLATION INSTRUCTIONS

ID+ 6" x 6" trim. High ceiling downlight with a choice of beamspreads is ideal for lobbies, atriums and convention centers.

SERIES 4LBV-NF Flush Mount Lumen Bridgelux LED Lensed Downlight

avenue led features dimensional data performance Narrow 3" slot LED with frosted satin lens.

LED Flat Panel Installation Instructions For 1 x4, 2 x2, and 2 x4 LED Flat Panels (FP Series)

NOVA suspension up and down, end feed with remote power supply

Reflectors are compatible with respective Marquise I series housings manufactured by Nora Lighting.

NOTCH 2 Symmetric - NT1-B. Luminaire NOTCH 2 - Area 100 Dn Symmetric (NT1-B) Type. Project. Product. Notes. Performance Summary

IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

RECESSED WALL WASH MOUNT

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

Project. Comments. Prepared by

PROFILE 100 Dn PF1-B. Luminaire PROFILE DN LED (PF1-B) Type. Project. Product. Notes. Performance Summary

Cylindrix III. Recessed Multiples

MONORAIL KITS INSTALLATION INSTRUCTIONS SPOTS

Essenza. Dim-To-Warm Round Downlights

HBDBM High Bay Series

Transcription:

Installation Instructions for 90ELED-WHL-FL Round or Square Chicago Plenum Hi-lume Wall Wash Housing with LED Lamp for Flanged Trims E_F_-L_WC-HL.0 LED - ROUND/SQUARE FLANGED GENERAL PRODUCT I NFORMATION: This product is suitable for indoor locations. This product can be dimmed with a standard electronic dimmer. This instruction shows a typical installation. CAUTION - RISK OF FIRE This product must be installed in accordance with the applicable installation code by a person familiar with the construction and operation of the product and the hazards involved. Use minimum 90 c supply conductors. Install the Housing with Adjustable Bars A B INNER ADJUSTABLE BAR HOUSING NAIL LEAVE TAB IN PLACE BREAK OFF AND DISCARD ½ to ¾ ¾ or thicker HOUSING CLASP NOTE: Skip this section if installing the housing with butterfly brackets. OUTER ADJUSTABLE BAR STOP POINT Keep Tab for ceiling ½ to ¾ thick. When using adjustable hanger bars with ½ to ¾ thick ceilings, leave the tab of the hanger bars in place. Break off Tab for ceiling ¾ or thicker. When using adjustable hanger bars with ¾ or thicker ceilings, remove the tab by bending it at the perforation. TAB Slide the inner adjustable bar completely through the three housing clasps. Make sure the nail is on top. Slide and push the outer adjustable bar completely onto the inner adjustable bar so that the tab clicks into place behind the stop point.this will prevent the adjustable bars from coming apart. Repeat steps & for the other side of the housing.

C D 7 NAIL ADJUSTABLE BAR HOUSING NAIL JOIST TRIM HOLDER TRIM HOLDER NOTCH NOTCH NOTE: The adjustable bars can be mounted to joists that are spaced " - " apart. HOUSING Align the bottom of the end plates with the bottom of the ceiling joists. TRIM HOLDER Level the adjustable bars and, with a hammer, tap the nails completely into the joists to secure the adjustable bars in place. # SELF TAPPING SCREW 7 Adjust the trim holder position (horizontal position) by sliding the housing on adjustable bars. When the desired location is achieved, tighten the two # self tapping screws to lock the housing onto the adjustable bars. TIP: Notches in trim holder can be used to align multiple housings using a laser or string.

Install the Housing with Butterfly Brackets Connect Power to the Housing A BUTTERFLY BRACKET NOTCH TRIM HOLDER A TABS ELECTRICAL BOX COVER WING NUT NOTE: Skip to page if installing the housing with adjustable bars. Slightly loosen the wing nut to slide the butterfly bracket up or down. B Push up on the tabs on the electrical box and remove the electrical box cover. CONDUIT After achieving the proper location, tighten the wing nut to secure the butterfly bracket in place. Repeat steps and on for the other butterfly bracket. Utilize the butterfly brackets to install the housing in accordance with local electrical codes. TIP: Notches in trim holder can be used to align multiple housings using a laser or string. Install the conduit to the housing electrical box. Run the power line wires into the housing electrical box. WARNING: RISK OF FIRE: When using the housing electrical box for power feed through, use MAX - # AWG, or - # AWG branch circuit wires.

Install Drywall and Plaster Ring C A -7/" -7/" ROUND TRIM HOLDER SQUARE TRIM HOLDER Connect the neutral power line wire to the white transformer wire with a wire nut. Connect the hot power line wire to the black thermal protector wire with a wire nut. For round trims, mark a -7/" diameter circle on drywall. Cut out the marked section. For square trims, mark a -7/" square on drywall. Cut out the marked section. Make sure that housing is grounded in accordance with local electrical codes. B 7 Replace the electrical box cover. Make sure that the top edge of the cover snaps under both tabs. For wire dimming applications see diagram below. D Wire Dimming DRYWALL TRIM HOLDER JOIST Align the cut out section of drywall with the trim holder and install drywall. 9 9 9 WARNING: Risk of Fire: The housing is not intended to be in contact with or covered with combustible materials and insulation. Do not install insulation within inches of the housing sides or above in such a manner to entrap heat. 9 For wire driver applications, properly connect the orange (dimmed hot) and the two purple wires (dimming/digital bus).

Replacing the Lamp A Adjust the Lamp Housing A C AUTION:To reduce the risk of a burn or electric shock during relamping, disconnect the power to the fixture. Remove the trim from the fixture. Loosen all three screws from the front cover and pull the LED lamp out.. B FRONT COVER LAMP Ensure that the lens assembly is centered to the aperture by pulling the assembly to the center of the housing.when centered the locking pin will be engaged. B ROTATION LOCK NOTE: Lamp housing can rotate horizontally. Use ONLY WATT proprietary Element Lighting LED lamp. Line up the square and round pegs in the new lamp with the holes in the heatsink and push the new lamp into place. Replace the front cover. Reinstall the trim. Pull the rotation lock down to unlock the lamp housing. Rotate the lamp housing horizontally. When the desired position is achieved push the rotation lock up to lock the lamp housing in place. NOTE: If installing optional lenses, see page for instructions before reinstalling the lamp assembly.

Install the Lenses (Optional) 7A 7C ES HOLDER Place lenses (max., optional) inside the lens holder. 7B Line up the legs of the lens holder with the notches on the lamp holder and push the lens holder on. Vertical Alignment Guides Horizontal Alignment Guides Use the lens orientation guides to align linear spread lenses vertically or horizontally.

NOTES 7

STATEMENT OF WARRANTY Tech Lighting warrants all products manufactured by Tech Lighting to be free from defects in material and workmanship under normal use for a specified period after the date of original purchase as follows: years for LED products; years for Energy Star qualified products; year for all other products. For details, visit our website at: www.techlighting.com/aboutus#warranty SAVE THESE INSTRUCTIONS! 700 Linder Ave. Skokie, IL 0077 7.0.00 www.element-lighting.com 0 Tech Lighting, L.L.C. All rights reserved.the "Element" graphic is a registered trademark of Element. Element reserves the right to change specifications for product improvements without notification.