Sanitary Yard Hydrant Installation Instructions

Similar documents
Sanitary Roof Hydrant Installation Instructions

TERMS OF USE TERMS AND CONDITIONS. Plumbing and Heating Products (PL-WR)

Series 957, 957N, 957Z, 957RPDA, 957NRPDA, 957ZRPDA

Watts Series CSM-61. Flow Measurement/Balancing Valves Sizes: 1 1 4", 1 1 2", 2", 2 1 2", and 3" (32, 40, 50, 65 and 80mm) Installation Instructions

4000SS. For other repair kits and service parts, send for Ames Repair Parts Price List, PL-A-RP-BPD.

Watts Series CSM-91. Grooved/Flanged Flow Measurement/Balancing Valves. Installation and Operating Instructions. Table of Contents. 1.

Installation, Operation and Maintenance Manual

Colt Series C400, C500

Installation, Maintenance, & Repair Series 919 and LF919

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Installation Service Repair Kits Maintenance RP/IS-774/774DCDA/774X/774XDCDA

THIS WARRANTY IS IN LIEU

Series 867 Reduced Pressure Zone Assemblies

Maintenance Manual Double Check and Double Check Detector Assemblies Series 850, 856, 870V & 876V 2 1 /2" - 10" (65 250mm)

Series 990/990RPDA. Reduced Pressure Zone Backflow Preventer. Sizes: 4", 6", 8" (100mm, 150mm, 200mm)

Installation, Maintenance, & Repair Series 995 Reduced Pressure Zone Backflow Preventers

Installation, Operation and Maintenance Manual

Installation Instructions

INSTALLATION GUIDE. Rainier Coil Pull Down Kitchen Faucet PB-K01

Series 007. Double Check Valve Assembly. Installation Service Repair Kits Maintenance. Sizes: 1 2" 3" Watts 3 4" 007M3QT RP/IS-007

Digital Print-out Test Kit for Backflow Preventer Assemblies

Float Level Control Kits

SAVE FOR CONSUMER INSTALLATION / OWNER'S MANUAL. Single Handle Kitchen Faucet Model # LK2500. Important! You choose the flow rate!

Aplos Single Lever Basin Faucet

FOR TECHNICAL ASSISTANCE

SAVE FOR CONSUMER INSTALLATION / OWNER S MANUAL. Includes: Tools: Mystic - Pull-Out Kitchen Faucet LKMY1041CR LKMY1041NK LKLFMY1041CR LKLFMY1041NK D 1

INSTALLATION GUIDE. Tenino Retro Pot Filler Hi-Rise Kitchen Faucet PB-K05

Installation Instructions / Warranty

PFS Rotameter. Variable Area Flowmeter. Instruction Manual PFS-RM200, RM230, RM250

Product Recovery Canister

Series 009. Reduced Pressure Zone Assemblies. Installation Service Repair Kits Maintenance. Sizes: 8 80mm. 80mm 009LF RP/IS-009-AUS

Hydro-Park High-end Four Post Parking Lift PROFESSIONAL PARKING SOLUTION PROVIDER!

Scale Feeder Manifold Water Filtration System Instruction Manual

TALCO FIRE SYSTEMS. LSF Start-Up Instructions. 1) IMPORTANT: Inspect the unit for damage. Report any damage to the freight carrier immediately.

6-12 WIDESPREAD 6-12 W. Cleopatra Series INSTRUCTION GUIDE SAVE THIS INSTRUCTION GUIDE

Dual/Triple Manifold Water Filtration Systems Instruction Manual

Pre-Installation 4 Point Checklist. Return Policy

Dual Flow Manifold Systems Instruction Manual

FIGURE 310AM, 310AMSW & 311AM 3-PIECE BALL VALVE

FIGURE 310A & 311A 3-PIECE BALL VALVE

Dual Port Manifold Water Filtration Systems Instruction Manual

Pressurized Bead Filters

Read this entire manual before operation begins.

Aquila Single Lever Vessel Faucet

Single Lever Pull-Out Kitchen Faucet

PCC O P E R A T I O N S. Pump Cycle Counter M A N U A L. Environmental Systems

ALITA LINEAR AIR PUMP OPERATION & MAINTENANCE MANUAL. AL- Model Number Date Code / Serial Number Date of Purchase

Manufacturing Facility is ISO9001:2000. Welded Steel Pipe Conform to ASTM A53. Threads Conform to ASME B1.20.1

Read this entire manual before operation begins.

Installation and Maintenance Instructions

Installation, Maintenance, & Repair Series 4000CIV

THE WARRANTY SET FORTH HEREIN IS GIVEN EXPRESSLY AND IS THE ONLY WARRANTY GIVEN BY THE COMPANY WITH RESPECT TO THE PRODUCT.

Sample Pro 3/4" Portable MicroPurge Pump. User's Guide P/N REV The World Leader in Air Powered Pumps

Installation Instructions / Warranty

Product Recovery Canister

RSV16 Retro-Fit Cartridge Acorn Controls SV16 Valve Cartridge

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

A S S E M B L Y I N S T R U C T I O N S

PRO JACK 4500 ROLLING BRIDGE JACK 4,500 POUND CAPACITY. PARTS MANUAL P/n NRJ450BK

INSTALLATION INSTRUCTIONS, PARTS LIST AND CONFIGURATION GUIDE FOR THE CARBONATOR. Large Model No

Straight-Bore Clutch LSCC-32, 44, 54

INTRODUCTION INSTALLATION

GM 2500,3500 Nerf Bar Installation Instructions

INSTALLATION INSTRUCTIONS. Automatic Sensor Retrofit Kit For Urinals and Toilets ZERK-CP Chrome-Plated Cover ZERK-CPM Chrome-Plated Metal Cover

TPHK Series Immersible Pump

Medi-Flow. Model M101 & M101D Medicator Instructions GETTING TECHNICAL ASSISTANCE

Installation & Operating Instructions for Zone Valve Boxes & Ball Valves

Single-Position Detent Clutch DC Series. (i) MTY (81) MEX (55) QRO (442)

INSTRUCTIONS AND SERVICE MANUAL WITH PARTS LIST

This manual is valid for the valve ordering numbers: E01/ E01/ E01/ E01/08

GLYCOL SYSTEM MONITOR (GSM)

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Bertolini Sprayer Operator s Manual

September 2012 / M&H C502 / Model 129

Installation and Maintenance Instructions

ESE Series Cast Iron Sewage Pumps

Strainer and Check Valves

Universal Hand Pump. Instructions D EN. - For transferring grease to Grease Jockey and G3 Systems - Part No Hand Operated - 35# Pump

INSTALLATION, OPERATION AND MAINTENANCE MANUAL

Installation Instructions / Warranty

Pump/Manifold Kits. Instructions F ENG. To convert E-Flo 4-Ball Piston Pumps to a different size lower. For professional use only.

Val-Matic 1-4 Combination Air Valve (Single Housing Type)

Pre-Installation 4 Point Checklist

MODEL 900 IMPELLER-TYPE FLOW METER

Artec Pro Single Handle Commercial Kitchen Faucet

Ball Valves. Quality Valves at Low Cost

Full Flow Drinking Water System Model: 3MFF100

Installation Instructions / Warranty. Citterio 39115XX1

BC Brake Caliper. (i) MEX (55) QRO (442) MTY (81) DIST. AUTORIZADO

Oletto Single Lever Bar/Prep Faucet

Single Lever Pull-Out Kitchen Faucet

AMES 2016 Price List. Backflow Prevention Products and Repair Kits and Parts. Effective February 29, 2016

TBM Series 3-Way Ball Valve

USE AND CARE GUIDE TIERED POTS FOUNTAIN

All products subject to this warranty must be returned for examination, repair or replacement to:

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

www. hydrofuse.com Installation Manual Fertilizer Machine V1.3

STAINLESS STEEL FORGED FITTINGS 3000lb 304/304L & 316/316L Forged Stainless Steel Fittings Product Specifications

PARTS DIAGRAM INSTALLATION INSTRUCTIONS

Elgin Hydraulic Clutch-Brake ECB-240, Product Number FORM NO. L F FORM NO. L F-0704

Transcription:

Installation Instructions Freeze Flow hydrants are designed for heavy-duty commercial use where safe potable water is needed. This hydrant drains into the canister below the frost line to prevent freeze ups and cross contamination with the soil bacteria INSTALLATION 1.) 2.) Hydrant canister must be placed below existing frost line. Figure1 No ground preparation is required for the Freeze Flow Sanitary Yard Hydrant; therefore it can be placed in any soil condition. Hydrant canister is stainless steel and pipes are all galvanized steel, which meet ASTM specs. It is still the responsibility of the installer to know his/her soil condition and to ensure that proper corrosion protection is administered to the hydrant. The application of paint or rubber tape may be needed to protect against some soil conditions. 3.) Flush supply lines BEFORE installing hydrant. 4.) Attach hydrant to existing supply line using an approved thread sealant. 5.) BEFORE back filling with soil, perform a Shut Off Valve Leak Check to make sure shut off valve does not leak due to debris in supply line or damaged o-ring. A leaking seat can cause hydrant to fill with water and possibly freeze. Shut Off Valve Leak Check: Remove backflow preventer at quick disconnect (Figure 2) Operate hydrant at partial flow with thumb over outlet until the water pressure forces past thumb. (Figure 3). At this point shut off hydrant. [ With hydrant full of water it is easier to detect if hydrant is leaking. Hydrant should not drip from outlet once hydrant is full of water. ] If hydrant leaks from outlet, remove operating rod and replace o-ring on stopper tip. (Figure 4) 6.) If no leaks are detected then replace backflow preventer and proceed to back fill hydrant with soil. 27 FROST LINE GROUND LEVEL BURY DEPTH Figure 1 SEAL, O-RING 21O17OOO2 Figure 2 Figure 3 Figure 4

Sanitary Yard Hydrant Operation and Maintenance Instructions OPERATION AND MAINTENANCE 1.) 2.) 3.) Packing Nut Leak Hydrant is designed to use clean water at 20 psi to 100 psi. Should leakage occur at packing nut, simply tighten nut until leakage stops. If tightening nut does not stop leakage, remove nut and replace with packing. Figure 5 To Change Seal, O-ring Unscrew packing nut from under handle. Unscrew handle and operating rod from hose bib. Lift out operating rod and change o-ring seal on tip. Replace operating rod and tighten packing nut. Leakage from float valve Leakage from float valve is typically due to not flushing supply lines properly. To clean, unscrew Hex Cap from round base. Remove ball and o-ring. Replace ball and o-ring after cleaning. Reassemble Float Valve. packing nut Figure 5 Float Valve Assembly 4.) Handle/operating rod adjustment No adjustment is necessary. 5.) To prevent unauthorized use, the hydrant wheel handle can be removed. 6.) NOTE: If the hydrant has not been used for a long period of time, it is advisable to flush the hydrant for 60 seconds when water is used for drinking.

Winterizing Instructions 1.) 2.) NO RESTRICTIONS, REMOVE HOSE AND BACKFLOW PREVENTER IF USED To prevent freezing during the winter months, it is essential that the hydrant reservoir be evacuated to ensure proper drainage of the standpipe. Any restriction downstream of the factory supplied hose bib will prevent the hydrant reservoir from emptying. Therefore, for winter use, remove the hose and backflow preventer, if used, using the quick disconnect supplied. FULLY OPEN 30 SECONDS SOLID Empty the reservoir by operating the hydrant at full flow for 30 seconds to prevent hydrant freeze-ups. 3.) 4.) WATER FLOW BECOMES AERATED FINISHED, SHUT OFF HYDRANT AERATED During this time you should notice the water flow is solid and then becomes aerated. Reservoir is empty when water exiting outlet is aerated. Shutting off hydrant at this point will permit the water in the standpipe to drain back into the empty reservoir. More Winterizing information is available at www.freezeflow.com

Parts Diagram ( X = BURY DEPTH) BULK (X = BURY DEPTH) (X = BURY DEPTH) Patent# 4,854,339 5,033,500 other patents pending

MANUFACTURER S LIMITED ONE YEAR WARRANTY Hoeptner Perfected Products warrants this product to be free from defects in material or workmanship for a period of one year from date of original shipment. Hoeptner Perfected Products will, at its option, repair or replace any part of this product that proves, upon our inspection, and within one year from date of shipment, to be defective in material or workmanship. Transportation costs or charges incidental to warranty service are to be borne by the purchaser-user. This warranty does not apply to goods or parts not manufactured by Hoeptner Perfected Products, instead Hoeptner Perfected Product s obligation for these parts is limited to the actual warranty extended to Hoeptner Perfected Products by the manufacturer. This shall constitute the exclusive remedy for breach of warranty, and Hoeptner Perfected Products shall not be responsible for any incidental or consequential damages, including without limitation, damages or other costs resulting from labor charges, delays, vandalism, negligence, fouling caused by foreign material, damage from adverse water conditions, chemicals, or any other circumstances over which Hoeptner Perfected Products has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or improper installation of the product. Hoeptner Perfected Products makes no other warranties express or implied of any kind with respect to the goods, parts and materials, including but not limited to, any implied warranty as to merchantability or as to the fitness of the merchandise for a particular use and shall not be liable for any loss or damage, directly or indirectly, arising from the use of such merchandise or for consequential or incidental damages RETURN POLICY All products returned must be in new, perfect condition in their original packaging. We will not accept returns after 30 days. All returns are subject to a 25% restocking fee. Shipping charges will not be refunded. All returns must be authorized in advance and be issued a Return Authorization Number - please call or e-mail us before sending returns. Returns sent to us without prior authorization will be refused delivery. IMPLIED WARRANTY There is no warranty other than the Manufacture s Limited One Year Warranty. HOEPTNER PRODUCTS