1ZSE en, Rev. 4. On-load tap-changers, type UC User s manual

Similar documents
1ZSC ABH en, Rev. 1. Motor-drive mechanisms, types BUE and BUL2 Maintenance guide

On-load tap-changers, types UCG, UCL, UCC and UCD with motor-drive mechanisms, types BUE and BUL Spare Parts List

1ZSE en, Rev. 5. On-load tap-changers, type UBB Maintenance guide

1ZSE en, Rev. 5. On-load tap-changer, type UCG with motor-drive mechanisms, type BUE/BUL Maintenance guide

Motor-drive mechanisms, type BUL Spare parts list

Motor-drive mechanism, type BUL. Technical guide

MG Maintenance Guide. June 30, 1998 New Information. Maintenance Guide

1ZSC AAA en, Rev. 6. Resin impregnated paper bushing, oil to SF 6., type GSBK Technical guide

1ZSE en, Rev. 3. Wall bushings, type GSA-AA Technical guide

1ZSC AAV EN, REV. 4. Tap-changers for power transformers Product guide

1ZVN A. Application manual

INSTRUCTION MANUAL RELAY FOR ON LOAD TAP CHANGER APPLICATIONS OR-25 5COR OR25 REV03

1ZSE en, Rev. 9. Transformer bushings, type GOB Technical guide

Transformer bushings, type GOA 250. Installation and maintenance guide

On-Load Tap-Changer VACUTAP VV

Resin Impregnated Paper Bushing, Oil to SF 6. , Type GSBK

Type VRLTC load tap changer Installation and maintenance guide

Transformer bushings, type GOH. Technical guide

Tension Meter. Edition FT 03.E. FT Series. Instruction Manual. Valid as of: Please keep the manual for future reference!

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

EStrong-series Emergency Stop

201F Fuel Pump Valve Assembly Leakage

FMC-1/2 Tina Muting unit

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

EXCOUNT-I. User s manual

Installation Instructions For Motor Control Center (MCC) Units

Relay Retrofit Program Cutting Tool Safety Guide

IQL Helios Area-/Streetlight. User Manual

1ZSE en, Rev. 9. Transformer bushings, type GSA-OA Technical guide

OPERATING INSTRUCTION

Switching DC Power Supply

Bushings for High Voltage AC Applications

INSTRUCTION MANUAL BR 25 FOR RAILWAY APPLICATION 5COR BR25AT REV00

EJ212 Electric Jack 1 Ton (2,000 lbs) Assembly & Operating Instructions

HEAVY DUTY PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

1ZSE EN, REV. 4. Wall bushings type GSA-AA Technical guide

Effective March 2015 Supersedes S August 2012

Hand Held Pull Tester Instruction Manual Order No

M OTO R. The electric motor. DC - direct current voltage.

DIGITAL BATTERY TORQUE WRENCH (BC-RAD SELECT) USER GUIDE

abb SafeLink SF 6 Insulated Ring Main Unit Installation and Operating Instructions Switchgear Division Auckland, New Zealand SLMIO ver 2.

S&C Type FVR Substation Circuit Breaker

ELECTRICALLY OPERATED TORQUE WRENCH (VC-RAD) USER GUIDE

Tina 10A/B/C Adaptor unit

Sense7-series Non-contact coded safety switch

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

Product Specification

Relay Retrofit Program for REX 521 Cutting Tool Safety Guide

CITY OF LOMPOC UTILITIES DEPARTMENT ELECTRICAL DIVISION SPECIFICATION NO. ELE-112 SUBSTATION CLASS VACUUM CIRCUIT BREAKERS OCTOBER 2008

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

MOTOR. The electric motor. DC - direct current voltage.

1ZSE en, Rev. 7. Transformer bushings, type GOB Technical guide

Tina 4A Connection block

B BASIC HEAT TREATMENT CONSOLE

Typical Specification

CEMLINE CORPORATION P. O. BOX 55 CHESWICK, PENNSYLVANIA Phone: (724) FAX (724)

en, Rev. 10. Transformer bushings, type GOH Installation and maintenance guide

University of Houston Master Construction Specifications Insert Project Name

IMPORTANT SAFETY NOTICE

PNEUMATIC TORQUE WRENCH (C-RAD) USER GUIDE

Extended Battery Cabinet for Nfinity

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Installation and operating manual Quick closing valve (Bellow sealed) LK product no:

SHOCK RELAY R INSTRUCTION MANUAL WARNING

Installation and Operation Manual

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Shanghai Huaming Power Equipment Co.,Ltd.

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Resin Impregnated Paper Bushing, Oil to Air, Type GSB Technical guide

Tina 11A Connection block

Smile 41 Push-button box with/without emergency stop

V. Design, Application, Maintenance & Operation Technical Requirements

Smile 11 RA/-B Smile 12 RF/-G Reset button

Innovation in soft start technology HFE-2 USER MANUAL. MAN-HFE-002. Version 01

Electrobar Elite. Instruction Manual. Conductor Bar System. ELITE-03A October 2011 Part Number: R3 Copyright 2011 Electromotive Systems

nual k Voltage Stabilizer N) manual New Brunswick Voltage Stabilizer Operating manual

NECO Pumping Systems

Operating instructions

2 TONNE TROLLEY JACK

1ZSC AAR EN, REV. 2. Oil filter unit, type OLU, for on-load tap-changers Manual

MKey9-series Safety Interlock Switch with Guard Locking

RENA AF371Feeder Operating Manual. Feeder. Operating Manual. Manual Part #: M AF371 Operations Rev

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

Information Bulletin. Fire Pump Battery Failures. Version 1.1 Approved for release August 2011

INSTALLATION GUIDE. Universal System for Zero Turn Mowers

HOME CHARGER MODE 2. Series to /32A single phase CONTENTS. Manual IMPORTANT SAFETY INSTRUCTIONS 3 SAFETY INFORMATION 4 INSTALLATION 5

Instruction Manual. ThinkTop D30 ESE02248-EN Patented Sensor System Registered Design Registered Trademark. Original manual _1

OPERATING INSTRUCTION

SecoVac * Ground & Test Device

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

COOPER POWER SERIES. ELSG Full-Range Current-Limiting Fuse Re-Fusing Instructions. Fusing Equipment MN132017EN

Battery Charger. Series EASY Charger. User s manual

Metrohm E3640 FLASH TESTER INSTRUCTION MANUAL. Martindale Electric Co Ltd.

HST-BL-2830MS & HST-BL-2830MS-USA

Single-phase step voltage regulators

Electrical network protection VIP30, VIP35. User s manual 12/2008

Submersible Effluent Pump

Transcription:

1ZSE 5492-155 en, Rev. 4 On-load tap-changers, type UC User s manual

Original instruction The information provided in this document is intended to be general and does not cover all possible applications. Any specific application not covered should be referred directly to ABB or its authorized representative. ABB makes no warranty or representation and assumes no liability for the accuracy of the information in this document or for the use of such information. All information in this document is subject to change without notice. This document must not be copied without our written permission, and the contents thereof must not be imparted to a third party nor be used for any unauthorized purpose. Contravention will be prosecuted.

The manufacturer Hereby declares that The products Manufacturer s declaration ABB AB Components SE-771 80 LUDVIKA Sweden comply with the following requirements: On-load tap-changers, type UC with motor-drive mechanisms, types BUE and BUL By design, the machine, considered as a component of a mineral oil filled power transformer, complies with the requirements of Machinery Directive 89/392/EEC (amended 91/368/EEC and 93/44/EEC) and 93/68/EEC (marking) provided that the installation and the electrical connection are correctly realized by the manufacturer of the transformer (e.g. in compliance with our Installation Instructions) and EMC Directive 89/336/EEC regarding the intrinsic characteristics to emission and immunity levels and Low Voltage Directive 73/23/EEC (modified by Directive 93/68/EEC) concerning the built-in motor and apparatus in the control circuits. Certificate of Incorporation: The machines above must not be put into service until the machinery into which they have been incorporated has been declared in conformity with the Machinery Directive. Date 2013-02-15 Signed by... Hans Linder Title Manager Tap-Changers, Local Product Group Unit Components

Introduction The UC range of on-load tap-changers manufactured by ABB has been developed over many years to provide maximum reliability. The simple and rugged design gives a service life equal to the service life of the transformer. Minimum maintenance is required for trouble-free operation. The only parts requiring maintenance are contacts that might need replacement during the service, the insulating oil and the motor-drive mechanism. The design allows ready access to all parts, making inspection and maintenance quick and simple. The tap-changers are housed in the transformer tank. The motor-drive mechanism, type BUE or BUL, is attached to the transformer tank and connected to the tap-changer by means of drive-shafts and a bevel gear. The same motor-drive can operate one, two or three units on the same transformer. Those units are then considered as one tap-changer. Safety warnings The following warnings and notes are used in the manual: Safety precautions Personnel operating and inspecting the tap-changer must have good knowledge of the apparatus and must be aware of the risks pointed out in this manual. Personnel making electrical connections in the motordrive mechanism have to be certified. Small amounts of explosive gases might come out from the breathing devices (dehydrating breather or one-way breather). Make sure that no open fire, hot surfaces or sparks occur in the immediate surroundings of the breathing devices. CAUTION After a trip from a supervisory device, an inspection must be made by a specialist. The diverter switch housing must be drained and the diverter switch lifted and carefully investigated before the transformer is reenergized. indicates an imminently hazardous situation, which if not avoided will result in death or serious injury. This signal word is to be limited to the most extreme situations. also indicates a potentially hazardous situation, which if not avoided could result in death or serious injury. CAUTION CAUTION indicates a potentially hazardous situation, which if not avoided may result in minor or moderate injury. It may also be used to alert of unsafe practices. CAUTION may also indicate property-damage-only hazards. INFO provides additional information to assist in carrying out the work described and to provide trouble-free operation. 4 User's manual UC 1ZSE 5492-155 en, Rev. 4

Operation The handcrank must not be inserted during electrical operation. If the tap-changer is not in the exact position and the handcrank is pulled out, the motor-drive mechanism will start and go to the exact position if the power supply is on. If a failure in power supply occurs during operation, the operation will be completed when the power returns. The position indicator shows the actual tap-position. The draghands show the max. and min. tap-position between which the tap-changer has been operating since last resetting. For BUE: The tap-change in progress indicator shows POSITION in service position, RAISE when operating in a raise operation and LOWER when operating in a lower direction. For BUL: The tap-change in progress indicator shows RED during operation and WHITE when the tap-changer is in service position. For resetting of the emergency stop, turn the knob clockwise and switch on the motor protective switch. The LOCAL/REMOTE switch. In position LOCAL the tapchanger can be operated by the RAISE/LOWER switch. In position LOCAL remote operation is rendered impossible. In position REMOTE the tap-changer is operated from the control room or by a voltage regulator. Local operation is not possible in remote position. In case of a failure in power supply for the motor-drive mechanism, it is possible to handcrank the tap-changer. Put the handcrank on the shaft. Make sure it has entered the slot in the shaft. Crank in the desired direction as per the information plate above the shaft. The number of turns for one step is also shown on the rating plate. When the handcrank is inserted all electrical operations are impossible. Continue cranking until the tap-changer in progress indicator shows POSITION for BUE or white colour for BUL. Thermostat for extra heater (option). We recommend a setting at +5 C. Hygrostat for extra heater (option). We recommend a setting at approximately 60 %. Outlet (option) with earth fault protector. Normally the tap-changer is controlled by a voltage regulator and no manual operation of the tap-changer and the motordrive mechanism is needed. 1ZSE 5492-155 en, Rev. 4 User's manual UC 5

Maintenance schedule CAUTION To maintain the high reliability of the tap-changer it is important that the rules for maintenance given below are followed. The maintenance schedule given on the rating plate should always be followed. The statement on the rating plate is maintenance after a certain amount of operations or after a certain time, whichever comes first. In addition to that, an annual inspection should be carried out. Maintenance of the tap-changer consists of three steps: Inspection to be carried out by the site personnel once a year. Overhaul to be carried out by a specialist at intervals stated on the rating plate. Contact replacement to be carried out by a specialist. The possible need for replacement is decided during overhaul. In addition to these three steps, oil samples according to IEC 60422, 2005-10, should be taken at regular intervals of 2-6 years for those tap-changers having a maintenance interval exceeding 7 years. Breakdown voltages according to IEC 60156, 1995-07, should be carried out. The test should be performed as soon as possible after sampling in order to do the test at almost the same oil temperature as in the tap-changer. The following values should be fulfilled: Tap-changer 1) All star point and all BIL 380 kv Others Dielectric strength 30 kv/2.5 mm 40 kv/2.5 mm 1) Star point is denoted N, the fifth letter in the type designation. The BIL value is the first numerical digit in the type designation on the rating plate. For instance: UCGRN 380/700. In case the dielectric strength of the oil is lower than the values given above, proceed as follows: Make sure the sample is analysed immediately after sampling in order to do the test at approximately the same oil temperature as in the tap-changer Measure at least five times and take an average. If the values still do not fulfill the requirements, the oil needs to be treated by filtering. For procedure, see the Maintenance guide. A specialist is a service engineer from ABB or an authorized person trained by ABB for maintenance work on UC tapchangers. 6 User's manual UC 1ZSE 5492-155 en, Rev. 4

Inspection CAUTION Approval should be given by the site engineer in charge for inspection as well as for operating the tapchanger. It is recommended to inspect the tap-changer once a year. This principally concerns the motor-drive mechanism and refers to a visual inspection inside the BUE/BUL cabinet to check that nothing is loose, and that the heater is functioning. In the motor-drive mechanism a counter registers every tapchange operation. During inspection the counter is read and noted. If possible, motor and counter are to be tested by operating one step and then back. If the tap-changer has its own oil conservator, the breather and the oil level indicator on the oil conservator are to be checked according to the instructions from the transformer manufacturer. The inspection is to be carried out while the transformer is in service. On the conservator the following are to be checked: Oil level Breather In the motor-drive mechanism the following items are to be checked: Motor and counter Emergency stop Heater Earth fault protector for the outlet (option) If the tap-changer is equipped with an oil filter unit, the pressure drop over the filter is to be checked. Required tools The following eq uipment is required for the inspection: Set of screwdrivers Pen and note pad Procedure Checking of the breather and the oil level must be carried out from ground level since the transformer is energized. 1. Checking of the breather The breathers and the tube from the conservator might contain explosive gases. No open fire, hot surfaces or sparks may be present when removing the breather. Check the breather according to the instructions for the transformer. 2. Checking of the oil level in the conservator The oil level in the conservator should be according to the instructions in the transformer documentation. 3. Checking of the motor and the counter Open the motor-drive cabinet door and turn the selectorswitch to the LOCAL position. Then turn the control switch to the RAISE (LOWER) position. Check that the motor works properly, the position indicator increases (decreases) one step, and the counter advances one step for each operation. Record the counter s value. The counter shows the number of operations performed by the tap-changer (the overhaul schedule can be determined with the help of this information). Turn the control switch to the LOWER (RAISE) position. Check that the motor also works properly in that direction, the position indicator decreases (increases) one step and the counter advances one step more. Reset the draghands. Read the counter and note the reading. 4. Checking of the emergency stop Press the emergency stop and the protective motor switch shall switch off. Reset the emergency stop by turning the knob clockwise and set the protective motorswitch to ON. 1ZSE 5492-155 en, Rev. 4 User's manual UC 7

5. Checking of the earth fault protector (option) If the motor-drive mechanism is equipped with an outlet, the earth fault protector should be tested by pressing the test knob on the outlet on BUE or on the separate earth fault protector on BUL. 6. Checking of the heater Before starting any work inside the motor-drive mechanism the auxiliary power must be switched off. N. B. The motor, contactors and heating element may be energized from separate sources. Disconnect the incoming auxiliary power. Open the control panel (BUE only). Check by feeling with a finger on the protection plate that the heater has been functioning. Close the control panel (BUE only). Reconnect the incoming auxiliary power. Complete the inspection by turning the selector-switch to the REMOTE position and close the cabinet door. 7. Checking of the oil filter unit (option) If the tap-changer is equipped with an oil filter unit from ABB: Read the pressure gauge. Check according to the oil filter manual. Note the reading so the change from year to year can be seen. If moisture is suspected to have come into the tap-changer compartment, the filter insert should be replaced. If a filter insert replacement is needed, call a specialist. 8. Trip or alarm from supervisory devices A tap-changer might be equipped with several different supervisory devices, such as pressure relay, oil flow relay and pressure relief device. Every tap-changer will be equipped with at least one of these devices. Even two or all of these might be installed. The pressure relay and/or the oil flow relay will trip the transformer in case their set points are reached. The pressure relief device might be set to an alarm only or trip as well. In case of an alarm but no trip, we recommend blocking the tap-changer for further operations and call a specialist for consultation as soon as possible. Plan for a possible outage to check the diverter switch. In case of a trip of the transformer, immediately call a specialist and do not try to energize the transformer again until a proper inspection of the diverter switch has been carried out. Prepare for a diverter switch lift. In both scenarios, collect the following information before calling the specialist: Serial number of the tap-changer Counter reading of the motor-drive mechanism If the trip/alarm came during switching. If so, between which positions. The load at the time of the trip/alarm Which devices have given the trip/alarm In case there are more than one tap-changer unit, try to figure out which one has tripped/alarmed. Any special service conditions at the time of the trip/alarm, such as overload, thunderstorms, etc. Before a specialist arrives, prepare for a lift of the diverter switch by making sure that a safe disconnection and grounding of the transformer is done. In case no local specialist is available, contact the after sales department. The contact information is found on the last page of this manual. Also check for leakages. All leakages should be repaired! 8 User's manual UC 1ZSE 5492-155 en, Rev. 4

1 2 1 3 4 5 6 9 7 10 8 Layout of on-load tap-changer. 1. Bevel gears 2. Horizontal drive shaft with protective tubes 3. Oil valve 4. Pressure relay 5. Top section 6. Vertical drive shaft with protective tubes 7. Rating plate 8. Motor-drive mechanism 9. Diverter switch housing 10. Tap selector 1ZSE 5492-155 en, Rev. 4 User's manual UC 9

1 3 2 8 4 6 5 7 9 10 11 8 12 15 14 13 16 Cabinet layout of motor-drive mechanism, type BUE. 1. Locking device prepared for padlock 2. Emergency stop 3. Air vent 4. LOCAL/REMOTE switch 5. RAISE/LOWER switch 6. Outgoing shaft 7. Lamp (40 W socket E27) 8. Lifting eye 9. Counter 10. Tap-change in progress indicator 11. Position indicator with drag hands for max. and min. position 12. Shaft for hand crank 13. Protective motor switch 14. Door-operated switch for lamp 15. Hand crank 16. Descriptions and circuit diagram 10 User's manual UC 1ZSE 5492-155 en, Rev. 4

1 2 14 4 3 5 12 8 6 7 16 9 10 11 13 15 6 Cabinet layout of motor-drive mechanism, type BUL2. 1. Position indicator with drag hands for max. and min. position 2. Tap-change in progress indicator (Red: in progress, White: in position) 3. Counter 4. Outgoing shaft with multi-hole coupling half 5. Shaft for hand crank 6. Locking device prepared for padlock 7. (Option) Outlet 8. Emergency stop 9. RAISE/LOWER switch 10. LOCAL/REMOTE switch 11. Protective motor switch 12. Air vent 13. Door-operated switch for lamp 14. Lamp 15. Descriptions and circuit diagram 16. Hand crank 1ZSE 5492-155 en, Rev. 4 User's manual UC 11

Contact us ABB AB Components SE-771 80 Ludvika, Sweden Phone: +46 240 78 20 00 Fax: +46 240 121 57 E-Mail: sales@se.abb.com www.abb.com/electricalcomponents Copyright 2013 ABB, All rights reserved. 1ZSE 5492-155 en, Rev. 4, 2013-04-15