Reservoir oil filler/breather

Similar documents
Check valve cartridge Type M-SR

2-way flow control valve

Double throttle check valve Type Z2FS 10

2/2-way poppet valves with solenoid operation Type KSDER1

Pressure reducing valve, pilot operated

Return line filter for direct tank mounting Type ABZFR

Pressure reducing valve, pilot operated Type DR

Throttle check valve. RE 27518/10.07 Replaces: Type Z2FS

Check valve. RE 21536/07.05 Replaces: Type Z1S. Size10 Component series 3X Maximum operating pressure 315 bar Maximum flow 100 l/min 1/6

Throttle and throttle check valve

Pressure relief valve, pilot operated

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Check valve. Type S. Contents. Features. RE Edition: Replaces:

Throttle check valve. RE 27526/04.08 Replaces: Type Z2FS

Pressure relief valve, pilot operated

Pressure relief valve, direct operated. Type ZDBY D, Z2DBY D. Features. Contents. RE Edition: Replaces: 01.09

Check valve, pilot operated

Pressure reducing valve, pilot-operated. Type Z3DR. Contents. Features. RE Edition:

Throttle check valve. Type Z2FS. Contents. Features. RE Edition: Replaces: 10.07

Pressure reducing valve, direct operated. Type ZDR. Contents. Features. RE Edition: Replaces:

Pressure relief valve, direct operated. Type DBD..K. Contents. Features. RE Edition:

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 10.05

Supply pressure compensator, direct operated

Pressure relief valve, pilot operated

Pressure reducing valve, direct operated

Pressure reducing valve, direct operated

Pressure sequence valve, direct operated

2-way flow control valve

Proportional pressure relief valve, directly operated, rising characteristic curve

迅捷 PDF 编辑器. Supply pressure compensator, direct operated RE 29231/ Type ZDC

Proportional flow control valve, with integrated pressure compensator

Pressure relief valve, pilot-operated. Type ZDB and Z2DB. Contents. Features. RE Edition: Replaces: 05.11

Pressure relief valve, pilot operated

Pressure reducing valve, direct operated

Directional spool and seat valves with electrical actuation and M12x1 plug-in connection

Meter-in pressure compensator, direct operated

Pressure sequence valve, direct operated

Twin throttle check valve

Pressure reducing valve, pilot operated. Type DR. Features. Contents. RE Edition: Replaces: 02.03

Pressure relief valve, direct operated, with DC motor actuation. Type DBGT. Features. Contents. RE Edition:

Bourdon tube pressure switch with infinitely variable switching pressure differential

3/2 directional spool valve, direct operated with solenoid actuation

Throttle and throttle check valve

Check valve, pilot operated

Pressure reducing valve, direct operated

Throttle and throttle check valve

2-way flow control valve. Type 2FRM, 2FRH, 2FRW. Contents. Features. RE Edition: Replaces: 07.04

2/2 directional seat valve, direct operated with solenoid actuation

Pressure relief valve, directly operated

Hydro-electric pressure switch

Check valve, pilot operated

Check valve, pilot operated

Bourdon tube pressure switch with infinitely variable switching pressure differential

RC /

Block mounting filter, lateral flange-mounting possible

Pipe burst safety valve

Block mounting filter, for sandwich plate mounting

Block mounting filter, for lateral flange-mounting

Throttle check valve. Type Z2FS. Features. Content. RE Edition: Replaces: 04.08

Pressure reducing valve, direct operated, with pressure monitoring

Block mounting filter, for lateral flange-mounting

Inline filter with filter element according to DIN 24550

Block mounting filter, for vertical flange-mounting

Proportional pressure reducing valve, pilot operated

Check valve, pilot operated

Inline filter with filter element according to DIN 24550

Inline filter with filter element according to DIN 24550

Accumulator shut-off block. Type ABZSS. Contents. RE Edition: Replaces: 05.13

Hydraulic inch power brake valve LT 31

Proportional pressure reducing valve, pilot operated

Pressure reducing valve, direct operated

Line filter. Features. RE 51400/01.09 Replaces: Types 40/100 LEN 0040 to 0400; 40/100 LE 0003, 0015, 0018

Pressure relief and feed valve, pilot operated. Type MHDBN. Features. Contents. RE Edition: Replaces:

Fixed displacement vane pumps Types PVV and PVQ

3/2 and 4/2 directional seat valves with solenoid actuation

Filter elements, two-stage for installation in wind turbines with Hydac filter housings. Type 65. Filter elements. Contents.

Check valve, pilot operated. Type SV and SL. Features. Contents. RE Edition: Replaces:

Rexroth Hydraulics. Pressure reducing valve, pilot operated, type 3DR 3DR 10 P 6X Y 00 RE /10.97

High-pressure inline filter, flangeable

Proportional pressure relief valve, directly operated, without/with integrated electronics (OBE)

Directional spool valves, direct operated, smoothly switching, with solenoid actuation

Hydraulic cylinder Type CDL1

Inline filter. Features RE 51401/ Types 40 FLEN 0160 to 1000; 40 FLE 0045, 0055, 0120 to 0270

Hydraulic drive power unit Low noise compact unit Wispering power unit

Filling valve sandwich plate

3/2 and 4/2 directional poppet valve with solenoid actuation

Accumulator shut-off block. Type 0532VAW. Contents. Features. RE Edition: Replaces: 07.10

Clamping and drive module

Proportional pressure relief valve with linear curve (Lvdt AC/AC)

Proportional pressure relief valve Types DBE(M) and DBE(M)E

Line filter with filter element according to DIN 24550

Type 400LDN0040 to 1000; 400LD0130, 0150

Proportional cartridge throttle valve, with inductive position transducer, pilot operated

Winch control block. RE 65051/08.04 Replaces: Type YM-WCB

Pressure limitation and feed valve, pilot-operated Type MHDBN...Y

Proportional pressure reducing valve, pilot operated, with inductive position transducer

Breather filter. RE 51414/02.09 Replaces: Types BF 7 SL ; BS 7 SL ; BE 7 SL ; B 7 SL

Filter cooler unit with inline filter according to DIN Type ABUKG. Contents. Features. RE Edition: Replaces: 50126

Proportional pressure reducing valve, direct operated, increasing characteristic curve Type MHDRE 06 SK (high-performance)

RK / HED 3 OA3X/.. with plug-in connector HED 3 OA3X/..K6.. HED 3 OA3X/..KL..Q with plug-in connector. with plug-in connector

Transcription:

Reservoir oil filler/breather RE 50070/10.05 Replaces: 01.03 1/10 Types ELF, BF and BL R 7802_2 Reservoir oil filler/breather with sieve type ELF 3... H_S_95 Reservoir breather type BF 7...K... Overview of contents Contents Page Features 1 Ordering details 2, 3 Technical data 4 Function, symbols, section 4, 5 Characteristic curves 5, 6 Unit dimensions 7 to 10 Features Resistant to mineral oil, fire resistant fluids (only build sizes 5 and 7) and bio-degradable fluids Good retention rate at low pressure drop Synthetic mesh filler sieve (metal mesh as standard in build size 5, also possible for build sizes 3 and 7) Larger filler sieve area Build size 7 with clogging indicator Bayonet joint between air filter and filler sieve (build sizes 5 and 7 with screwed joint) Air filter secured to filler sieve by means of a chain (build sizes 3 and 4) Build sizes 5 and 7 are fitted with replaceable elements (see table on page 3) Spin on filter cartridge type BL Welded joint in type BL Information on available spare parts: www.boschrexroth.com/spc

2/10 Bosch Rexroth AG Hydraulics ELF, BF, BL RE 50070/10.05 Ordering details Reservoir air breather with filling sieve with spin-on-cartridge = BF = ELF = BL Filter material paper fibre = P Build size 3 = 3 Build size 4 Only with = 4 Build size 5 ELF and BF = 5 Build size 7 = 7 Build size 162 Only withbl 62 Threaded connection, only with BF = G Flanged connection, only with ELF and BF = F Welded connection, only with BL = S Filter rating 3 µm absolute (only with ELF and BF) = 03 10 µm absolute 0 Clogging indicator Without connection possbilities for clogging indicators = W With pressure gauge, measuring range 1 to +0,6 bar = K (only with ELF7 and BF7) Connection sizes Filter type ELFP3... ELFP4... ELFP5... ELFP7... BFP3... BFP4... BFP5... BFP7... BLP162F... BLP162S... Threaded connection (G) G 2 1/2 G 3 G 2 G 1 1/2 G 3/4 G 3/8 G 1/2 G 1/4 G 2 1/2 G 1 = Available, also see pages 7 to 10 Preferred filter types FILTER P X * Flanged connection (F) Welded connection (S) Connection sizes 1; 2) 1) = 2 = 3 = 4 = 5 2) = 2 = 3 2) = 2 3) = 2 Further details in clear text Additional details AS = 4) Surge protection SO175 = 4) Metal filter sieve (100 mm long) SO148 = 4) Metal filter sieve (200 mm long) No code = NBR seals, filter suitable for use with mineral oil (HL, HLP) to DIN 51524 and fast bio-degradable pressure fluids HETG, HEES, HEPG to VDMA 24568 V = 5; 6) FKM seals, filter suitable for use with phosphate ester (HFD-R), polyglycol (HEPG) and synthetic ester (HE) seals, filter suitabale for use with oil-in-water or water-in-oil emulsions (HFA), water glycol (HFC) and vegetable oils (HETG) W = 5; 6) NBR X = Series Nos. 0 to 9 Filter type Filter rating in µm Type description Material No. 10 FILTER ELFP 3 F10W1.X/ R900011023 ELF 10 FILTER ELFP 4 F10W1.X/ R900011241 10 FILTER ELFP 5 G10W4.X/ R900005153 Further preferred types and standard components can be found in the EPS (Stan dard Price List). 1) Flange mounting with self tapping cap screws 2) Flange mounting to DIN 24557/T2 3) Weldabale joint, material: St 35 4) Only with ELFP 3 and 7 5) Suitable for use with fire resistant fluids Build size HFA HFC HFD-R 3 4 5 W W V 7 W W 162 6) Suitable for use with bio-degradable fluids Build size HETG HEES HEPG 3 + + 4 + + 5 + + 7 + + 162 + + + Unlimited use Not suitable Only limited use

RE 50070/10.05 ELF, BF, BL Hydraulics Bosch Rexroth AG 3/10 Ordering details for replacement air filter elements (only possible for build sizes 5, 7 and 162) For types ELFP 5 and BFP 5 FILTERELEMENT 0005 L P V * Build size 5 = 0005 Element type L = P Filter rating 3 µm = 003 10 µm = 010 Filter material P = P V = Further details in clear text FKM seals, filter suitable for use with phospate ester (HFD-R), polyglycol (HEPG) and synthetic ester (HE) For types ELFP 5 and BFP 7 FILTERELEMENT 0007 L P V * Build size 7 = 0007 Element type L = P Filter rating 3 µm = 003 10 µm = 010 Filter material P = P V = Further details in clear text FKM seals, filter suitable for use with phospate ester (HFD-R), polyglycol (HEPG) and synthetic ester (HE) Ordering details for type BL 162: FILTERELEMENT 0160 MU010P Technical data (for applications outside these parameters, please consult us!) General Installation Vertical, max. 30 from vertical Filter cartridges and Build sizes 3, 4, 5 Paper fibre, depth filter (3, 10 µm) filter rating Build size 7 Impregnated paper, depth filter (3, 10 µm) Build size BLP 162 Phenol resin impregnated paper, filter rating 10 µm Weight Build size 3 4..5-..2.X/....5-..3.X/....5-..4.X/....5-..5.X/.. 7 Type ELF kg 0.25 0.10 2.7 3.1 2.7 2.6 0.38 Type BF kg 0.28 0.08 2.00 0.40 Type BLP 162 S kg 1.75 Type BLP 162 F kg 2.10 Hydraulic Pressure fluid Mineral oil (HL, HLP) to DIN 51524; Fast bio-degradable pressure fluids to VDMA 24568 (also see RE 90221); HETG (rape seed oil); HEPG (polyglycols); HEES (synthetic ester); Other pressure fluids on request Pressure fluid temperature range C 10 + 100 Filling sieve filter rating (only with type ELF) µm 500 Cleanliness class to ISO code Maximum permissible degree of contamination of the pressure fluid is to ISO 4406 (c) relates to the requirements for the entire hydraulic system 1) Pneumatic Air flow See characteristic curves 1) The cleanliness class stated for the components must be adhered too in hydraulic systems. Effective filtration prevents faults from occurring and at the same time increases the component service life. For the selection of filters see catalogue sheets RE 50070, RE 50076, RE 50081, RE 50086 and RE 50088.

4/10 Bosch Rexroth AG Hydraulics ELF, BF, BL RE 50070/10.05 Function, symbol, section The reservoir oil filler/breathers, type ELF basically comprises of an air filter for filtering the air flowing into the reservoir and a filler sieve for retaining coarse dirt particles while filling. The reservoir breathers, types BF and BL are, however only air filters. Symbol With clogging indicator version "K" (only build size 7) Reservoir filler/breather type ELF Reservoir filler/breathers, type ELF are combined air filters for filtering air flowing into the fluid reservoir and filler sieves for retaining coarse dirt particles when filling. The large sieve area allows the pressure fluid to be rapidly filled. Types ELFP 3... and ELFP 4... These basically comprise of filter cap (1), air filter element (2), filler sieve (3) and security chain (4). Air enters via holes (5) on the underside of filter cap (1). In this way, only particles suspended in air may enter the air filter element (2), where they are separated according to the filter rating. Type ELFP 3... 2 5 4 3 1 5 Type ELFP 5... These basically comprise of an air filter housing (cover 1.1; lower component 1.2), air filter element (2) and filler sieve which is screwed onto the air filter (3). Air enters via the ring gap (5) between cover 1.1 and the lower component 1.2. In this way, only particles suspended in air may enter the air filter element (2), where they are separated according to the filter rating. They are fitted with replaceable air filter elements (2). Type ELFP 5... 1.1 1.2 5 2 3 Type ELFP 7... These basically comprise of an air filter housing (cover 1.1, lower component 1.2), air filter element (2) and filler sieve (3). Cover (1.1) and the lower component (1.2) are made of glass fibre reinforced plastic and connected to each other via threads. Air enters via openings (5) on the sides of lower component (1.2). In this way, only particles suspended in air may enter the air filter element (2), where they are separated according to the filter rating. They are fitted with replaceable air filter elements (2). For the monitoring of element contamination, the filters are available with a pressure gauge (6). Type ELFP 7...K... 1.1 5 1.2 6 2 3

RE 50070/10.05 ELF, BF, BL Hydraulics Bosch Rexroth AG 5/10 Function, symbol, section Reservoir breathers BF and BL Reservoir breathers, type BF are only designed as air filters and are screwed directly onto the reservoir. In principle, the function of these filters is the same as the ELF filler/breather. The difference is in that the filling sieve is not included. Build sizes 5 and 7 are equipped with replaceable air filter elements. Type BL breathers comprise of a mounting stud (6) which is fitted onto the reservoir and a filter cartridge (2). The filter cartridge screws onto the stud. 2 6 Type BFP 7...K... Type BLP 162 S... Characteristic curves (air flow in standard litres per minute. The characteristic curves are valid for all filter ratings!) Pressure differential in bar Pressure differential in bar Pressure differential in bar 0,04 ELFP 3 and BFP 3 0,03 0,02 0,01 0 200 400 600 800 1000 1200 0,04 ELFP 4 and BFP 4 0,03 0,02 0,01 0 50 100 150 200 250 300 0,04 BLP 162 0,03 0,02 0,01 Pressure differential in bar Pressure differential in bar 0,04 ELFP 5 and BFP 5 0,03 0,02 0,01 0 1000 2000 3000 4000 5000 6000 0,04 ELFP 7 and BFP 7 0,03 0,02 0,01 0 400 800 1200 1600 2000 2400 0 500 1000 1500 2000 2500 3000

6/10 Bosch Rexroth AG Hydraulics ELF, BF, BL RE 50070/10.05 Filter design Pressure differential at the air filter In the clean condition the pressure differential for each build size can be determined from the characteristic curves on page 5. Selection criteria We recommend that the air filter (with clean element) is selected using the filter selection diagram. Start-up - p = 0,01 bar Filter ELF and BF p = 0,01 bar 3000 2000 1000 500 100 50 ELFP 4/BFP 4 ELFP 3/BFP 3 ELFP 7/BFP 7 ELFP 5/ BFP 5 10 Filter selection diagram, example The filter selection diagrams are valid for the air filter types ELF and BF, build sizes 3, 4, 5, 7 and types BLP 162 S and BLP 162 F. The filter sizes are determined with the help of the selection diagrams, using a pressure differential of 0,01 bar. The following example explains the method of using the filter selection diagrams: Example: Air flow Q l (in standard litres per minute): 300 l N /min Filter type: ELF-Filter Recommended start-up- p : 0.01 bar Determination of the build size for Q l = 300 l/min using the filter selection diagram: Build size 3 Filter type: ELFP 3-..-... Filter BLP 162 p = 0,01 bar 3000 2000 1000 500 100 50 10 BLP 162

RE 50070/10.05 ELF, BF, BL Hydraulics Bosch Rexroth AG 7/10 Unit dimensions (dimensions in mm) Types ELFP 3... and ELFP 4... Ø Ød1 h3 Porting pattern ELFP 4 d4 d5 d4 d5 d6 d6 Type ELFP 3 ELFP 4 Ø d1 76 44 Ø 83 50 Ø d3 49 28 Ø d4 73 41,3 Ø d5 60 30 d6 M5 M5 159 135 96,5 81,5 h3 62,5 53,5 Ød3 Porting pattern ELFP 3 to DIN 24557/part 2 Type ELFP 5 SW 17 Ød1 h5 h3 1 h4 d3 Ø Type ELFP 5G..2.X/.. ELFP 5G..3.X/... ELFP 5G..4.X/... ELFP 5G..5.X/... Ø d1 177 177 177 177 Ø 68 68 49,5 39,5 d3 G 2 1/2 G 3 G 2 G 1 1/2 ISO 228 ISO 228 ISO 228 ISO 228 345 345 345 345 240 240 240 240 h3 105 105 105 105 h4 25 25 25 25 h5 90 90 90 90 Pos. 1 90 90 90 90 Across flats The air filter element is replaceable (see ordering details on page 3).

8/10 Bosch Rexroth AG Hydraulics ELF, BF, BL RE 50070/10.05 Unit dimensions (dimensions in mm) Type ELFP 7 h4 h3 Ød1 b1 3 2 Type ELFP 7 Ø d1 116 Ø 120 Ø d3 49 Ø d4 73 Ø d5 60 d6 M5 181 2 6 off slotted counter sunk screws M5 x 16 DIN 963 3 Optional pressure gauge as clogging indicator, measuring range 1 to + 0.6 bar The air filter element is replaceable (see ordering details on page 3). 97 h3 84 h4 60 b1 44 Ød3 d4 d5 ELFP 7... d6 Porting pattern to DIN 24557/part 2 Types BFP 3 and BFP 4 Ød1 Type BFP 3G..1.X/.. BFP 3G..2.X/... BFP 3G..3.X/... BFP 4G..1.X/... Ø d1 76 76 76 44 G 3/4 G 3/8 G 1/2 G 1/4 ISO 228 ISO 228 ISO 228 ISO 228 Ø d3 19 12 15 8 79 72 76 62 Ød3 1 16 12 14 13,5 Pos. 1 36 22 27 17 Across flats Type BFP 5 Ød1 SW 17 Type BFP 5G..1.X/... Ø d1 177 G 2 1/2 ISO 228 102 90 The air filter element is replaceable (see ordering details on page 3).

RE 50070/10.05 ELF, BF, BL Hydraulics Bosch Rexroth AG 9/10 Unit dimensions (dimensions in mm) Type BFP 7 Ød1 b1 Type BFP 7G..1.X/... Ø d1 116 G 1 ISO 228 Ø d3 120 108 d3 3 60 h3 18 h3 1 b1 44 Pos. 1 41 Across flats 1 41 mm across flats 3 Optional pressure gauge as clogging indicator, measuring range 1 bar to + 0.6 bar The air filter element is replaceable (see ordering details on page 3). BFP7... Type BLP 162 F h3 Ø d1 Type BLP 162 F Ø d1 127 Ø 83 Ø d3 73 Ø d4 60 d5 M5 h4 Ø d6 25 254 175 h3 90 h4 2 d3 d4 d5 4 Seal is included within the scope of supply The air filter element (cartridge) is replaceable (see ordering details on page 3). 4 Ø d6 Ø Porting pattern to DIN 24557/T2

10/10 Bosch Rexroth AG Hydraulics ELF, BF, BL RE 50070/10.05 Unit dimensions (dimensions in mm) Type BLP 162 S h3 Ø d1 Type BLP 162 S Ø d1 127 Ø 43 Ø d3 25 Ø d4 41 245 175 h3 90 h4 6 The air filter element (cartridge) is replaceable (see ordering details on page 3). Ø d4 h4 Ø d3 Ø Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de Bosch Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80/22 32 56 Fax: 0 14 80/21 90 52 E-mail: info@boschrexroth.co.uk This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

RE 50070/10.05 ELF, BF, BL Hydraulics Bosch Rexroth AG 11/10 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de Bosch Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80/22 32 56 Fax: 0 14 80/21 90 52 E-mail: info@boschrexroth.co.uk This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.

12/10 Bosch Rexroth AG Hydraulics ELF, BF, BL RE 50070/10.05 Notes Bosch Rexroth AG Hydraulics Zum Eisengießer 1 97816 Lohr am Main, Germany Telefon +49 (0) 93 52 / 18-0 Telefax +49 (0) 93 52 / 18-23 58 documentation@boschrexroth.de www.boschrexroth.de Bosch Rexroth Limited Cromwell Road, St Neots, Cambs, PE19 2ES Tel: 0 14 80/22 32 56 Fax: 0 14 80/21 90 52 E-mail: info@boschrexroth.co.uk This document, as well as the data, specifications and other information set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be reproduced or given to third parties without its consent. The data specified above only serve to describe the product. No statements concerning a certain condition or suitability for a certain application can be derived from our information. The information given does not release the user from the obligation of own judgment and verification. It must be remembered that our products are subject to a natural process of wear and aging.