CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

Similar documents
CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

CUSTOMER: 12038III (CeraDyna Fan) DATE : April 23, 2007 CUSTOMER APPROVAL

PREPARED 研發處 研發處 研發處 林佑亮 吳靜心 李群雪 AK1751HB DATE 研發處 P.S. AC FAN (RoHS) REV 發行章

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS BLOWER. DIMENSIONS : 45X45X9 mm M O D E L : GB0545AFV1-8

Product Data Sheet 4184 NXHH

Product Data Sheet DV5214 NU

Product Data Sheet 4118 N/ The engineer's choice

Product Data Sheet 4184 NXHH

Product Data Sheet 4184 NGX

Product Data Sheet 4414/2H

Product Data Sheet 8412 NHU-519

Product Data Sheet 632 NU-006

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 3214 JH3-195

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet ACi 4420 MLR

Product Data Sheet DV4118 N

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 8414 NGH

Product Data Sheet 8314 HR-197

Product Data Sheet 4184 N/17X. The engineer's choice

product specification

4314/17T. Product Data Sheet INDEX

Product Data Sheet ACi 4420 HHR

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Brushless DC Axial Fans

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

IN-LINE CENTRIFUGAL DUCT FANS VT Series

HXBR / HXTR Series PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

Specification Approval Sheet

Energy-saving motors (ESM)

PLATE MOUNTED SICKLE BLADE AXIAL FANS WITH EXTERNAL ROTOR MOTOR HXBR / HXTR Series. Plate mounted axial flow fans HXBR/HXTR. Corrosion resistance

CENTRIFUGAL IN-LINE FANS VENT Series

Specification of Soneil Battery Charger

SOLSTART Instruction Manual

CBM Series LOW PRESSURE CENTRIFUGAL FANS CBM. Low pressure centrifugal fans. Impeller dynamically balanced. Anti-vibration mounts

MPPB Series. Metallized Polypropylene Film Capacitor Box type. Metallized Polypropylene Film Capacitor - Box type Features. Typical Applications

MB Series AC Centrifugal Blowers

PSC Thermal Solutions. size 273 x 220 x202mm

56 mm sq. (2.20 inch sq.)

SPECIFICATION FOR APPROVAL

DC2-Wire Unshielded Cylindrical Proximity Switches

SPECIFICATION FOR APPROVAL

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

size Unit:mm

Rotron NANOS Small Vaneaxial Fans

DC Brushless Cooling Fan Behavior Or What Your Fan Data Sheet Isn t Telling You

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

Technical Specifications

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

Company Introduction Construction & Specific Parts and Illustration Appliation For Blowing Application for Suction...

Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY CHARGER

Hinged Safety Door Switch

Non-Spring Return EconoDrive Floating Actuator

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Model Number Structure

ECP180 Series. Low 1 Profile. High Power Density. 2.0 by 4.0 Footprint. 120W Convection-cooled Rating. 180W Force Cooled Rating

Hammond Electronic Rack Packaging

CENTRIFUGAL DIRECT DRIVE FANS CMT-CMB

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

Climate Control Products

Rotron MIL-80 Tubeaxial Fans

UNA SERIES Embedded Power Supply Features Model naming method UNA 350P / Applications UNA Conformity to RoHS Directive Product Line-up

Model Number Structure

Eco Mixed Flow (emf) Energy Saver. Terminal Box. Performance. Quality Assurance. Impellers. Accessories. Motors

AC Fans. AC Fans Overview 117. AC Axial Fans 118. AC Radial Fans 138. Technology. DC Axial Fans. DC Radial Fans. Specials. ACmaxx Axial Fans.

Subminiature Basic Switch

CVAB / CVAT Series ACOUSTIC CABINET FANS CVAB / CVAT. Acoustic cabinet fans. Backward curved centrifugal impellers.

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Luzchem Solar Simulator SolSim2 Updated September 2018

WK25S WK20S WK10S WK12S WK08S WK06S. Thick Film Power Surge Chip Resistors AEC Q-200 Qualified Size 2512, 2010, 1210, 1206, 0805, 0603

CBM Small Series LOW PRESSURE CENTRIFUGAL FANS. CBM Small. Low pressure centrifugal fans. Impeller dynamically balanced.

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

Switching Power Supply

Limit Switch D4D- N. Small, Economical Switch Featuring a Positive Opening Mechanism and Conforming to the CE Mark

Axial fans 400ºC/2h and 300ºC/2h With soundproofed box. Extraction units with axial fans to work inside fire danger zones.

Specifications 2019-V AC-DC Din Rail Mounted Power Supply IS-70 Series, 70W

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

ACOUSTIC CABINET FANS CVAB / CVAT Series

Multifunctional roof fans for large flows. Multifunctional roof fans, highly robust construction, for large flows

Pump Specifications. ELV Series Submersible Sump Pump with OilTector Control. ELV250 1/3 hp ELV280 1/2 hp ELV290 3/4 hp

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

AC axial fan. blades with special design (K series) with guard grille for full nozzle

TD BRIC Application Specification. May not be distributed or reproduced without written permission Rev: 10-Apr-2018 Page 1/26

ROOF MOUNTED AXIAL FLOW FANS HCTB / HCTT Series

CMB / CMT Series CENTRIFUGAL SINGLE INLET FANS. Centrifugal direct drive fans CMB/CMT 80 C. Impeller dynamically balanced

IN-LINE DUCT FANS MIXVENT-TD Fan Systems

Transcription:

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: 2013.08.28 CUSTOMER APPROVAL Taiwan ACT-RX TECHNOLOGY CORPORATION TEL: 886-2-82421111 2F, No.192, Lian Cheng Road, Zhonghe Dist., New Taipei City 235, Taiwan (R.O.C.) FAX: 886-2-82452200 Approved QC Checked Checked Prepared Page 1 of 11 REV.:A00

CONTENTS 1. SCOPE 3 2. ELECTRICAL 3 3. MATERIAL 4 4. MECHANICAL..4 5. EXPECTED LIFE SPAN (MTTF)....4 6. NOISE MEASUREMENT.......5 7. RELIABILITY... 6-7 8. PRODUCT LABEL...7 9. PERFORMANCE CHART..8 10. ASSEMBLY DIAGRAM......9 11. ORDERING AND OPERATING REMARKS... 10 12. FAN PACKING DATA... 11. Page 2 of 11

1. SCOPE This document is a specification defining the electrical and mechanical characteristics of the product. 2. ELECTRICAL Standard operating condition is 25, 65%RH ambient, unless otherwise specified. Item Specification Test Condition 1 Rated Voltage 12V DC power supply 2 Rated Current 0.25 Amp (Typical) DC power supply at Rated Voltage This is for Safety Regulation. 3 Rated Power 3 W At Rated Voltage. 4 Starting Voltage 6V (Min.) DC power supply 5 Insulation Resistance 10MΩ (Min.) 6 Speed 9300 RPM ±10% Input 500V(DC) between Lead wire(+) and housing Measured at 5 minutes after starting under 25±5, 65± 5%RH ambient 7 Acoustical Noise 8 Static Pressure 9 Air Flow 41.5 db(a) (measurement tolerance ± 2 dba) 10.9 mm-h 2 O (0.43 inch-h 2 O ) 12.22 CFM (0.35CMM ) Measured at typical speed with an acoustic microphone 1 meter away from the fan intake in a test chamber with background noise level below 18dB(A) under ISO-3745 Standard, refer to NOISE MEASUREMENT ITEM 7. Refer to PERFORMANCE CHART ITEM 9 at zero airflow. This measurement is performed AMCA 210-99 Refer to PERFORMANCE CHART ITEM 9 at zero static Pressure. This measurement is performed AMCA 210-99 standard. 10 Direction of rotation Counter- anticlockwise DC power supply, viewed from impeller. Page 3 of 11

3. MATERIAL Impeller Frame Bobbin +:Red :Black Lead Wire :PWM O/P: White Yellow PBT UL94-V0 PBT UL94-V0 PBT UL94-V0 UL 1007 AWG 24 26 28 4.MECHANICAL Dimensions L * W * H =40*40*20 (mm) Weight 30 grams Standard operating temperature range -10 ~ 75 Standard storage temperature -20 ~ 80 Bearing system 5.EXPECTED LIFE SPAN (MTTF) Two Ball Bearing One Ball One Sleeve Bearing Sleeve Bearing Alloy Sleeve with Ceramic Shaft Ceramic Bearing with Ceramic Shaft At a standard operating condition of 25±5, 65±5%RH ambient, the expected life(expressed as Mean Time To Failure) of products are evaluated under MIL-STD-781 Standard as below : Two Ball Bearing:65000 hrs, Continuous operating under 25 65%RH One Ball One Sleeve Bearing:50000 hrs, Continuous operating under 25 65%RH Sleeve Bearing:30000 hrs, Continuous operating under 25 65%RH Alloy Sleeve with Ceramic Shaft:300000 hrs, Continuous operating under 25 65%RH Ceramic Bearing with Ceramic Shaft:500000 hrs, Continuous operating under 25 65%RH Page 4 of 11

6. NOISE MEASUREMENT: B & K 4190 Noise is measured under Rated Voltage in free air in the anechoic chamber with B & K Nexus 4350 conditioning amplifier, with B & K 4190 microphone at a distance of one meter from the fan intake. The background noise is 18dBA max under the ISO-3745 Page 5 of 11

7. RELIABILITY Item Specification Test Condition 1 Locked Rotor Test Flameproof and damage free Rotor locked for 72 hrs with Rated Voltage Reverse Voltage Test 2 Protection 3 Balance Test 4 Drop Test 5 Vibration Test High/Low Temperature 6 Cycling 7 Low Temp. Test Yes No protruding beyond the circle within 10 seconds Reverse 15 min with Rated Voltage The fan runs in a circle, scaled by fan radius plus 20mm, on a perfectly smooth plate for 10 seconds under the ISO 1940 G6.3 grade Drop D.U.T.(The standard packing) from the test machine at 76cm below. Individual one angle, three diagonal corners and six planes under the IEC 68-2-31 Ambient temp.:25 ºC±5 ºC with Rated Voltage Amplitude:0.4-2.5 mm Acceleration:14.7 S/m 2 Frequency:10HZ-60HZ Sweeping period:11 min 10HZ-60HZ:10 min 60HZ-10HZ:10 min Total:10 cycles This test is under the IEC 68-2-6 20 minutes slew rate +75 ºC (12 hr), 20 ºC (12 hr) Total:25 cycles with Rated Voltage This test is under IEC 68-2-38 Tested under standard condition; after 500hrs, -25 ºC, with power supply. This test is under IEC 68-2-1 Page 6 of 11

8 High Temp. Test 9 Hi Pot Test Tested under standard condition; after 500hrs, 80 ºC, with power supply. This test is under IEC 68-2-2 Input 500V(AC) for 1 min between lead(+/-) and housing. This test is under CNS-C6013 8. PRODUCT LABEL Page 7 of 11

9. PERFORMANCE CHART This measurement is according to the AMCA 210-99 ACT-RX TECHNOLOGY CORPORATION PQ curve for FD1240-A0241D0AL under Rated Voltage. Page 8 of 11

10.ASSEMBLY DIAGRAM General Dimension.Tolerances (Unit:mm) 0-3 ± 0.3 3-30 ± 0.4 31-60 ± 0.5 61-100 ± 0.6 101 and Over ± 0.6 Angles ± 2 Note : 1. L*:Lead wire length:300±5mm (From frame edge) Page 9 of 11

11. ORDERING AND OPERATING REMARKS ACT-RX TECHNOLOGY CORPORATION 11.1 Please indicate Part No. on every order. 11.2 For those not specified but vital to your requirement, ACT-RX is in full position to supply qualified substitutes. 11.3 ACT-RX does not guarantee the product if applications exceed specified limitations. 11.4 Please do not touch the impeller and never carry the fan the lead wires. The bearings and the lead wires may be damaged. 11.5 Please do not use the fan in the environment of corrosive gas or liquid. 11.6 Please do not store the fan in the environment of high humidity. Please avoid storage of the fan over 6 months. For long term storage, please connect power to the fan shortly every 6 months even through the fan is stored in room temperature. 11.7 Improper use may lead to malfunction. To ensure normal operation, avoid dipping the fan into watery and oily liquid, or exposing it to heat, etc. 11.8 Please do not lock the rotor for those fan models without Auto Restart function during operation to prevent over heating which may cause permanent damage. 11.9 Warrantee period is 12 months max. under the environment condition IP-20 specified in IEC60529. 11.10 All specifications subject to change without prior notice. Page 10 of 11

12.FAN PACKING DATA Page 11 of 11