PART NO: FD1212-A2251G2AL. DATE : June 9, 2010 CUSTOMER APPROVAL

Similar documents
PART NO: FD2460-C0151E2AL CUSTOMER APPROVAL

CUSTOMER: MODEL NO: 4020II (CeraDyna Fan) NO: FD2440-C0151D2AL. DATE : September 3, 2007 CUSTOMER APPROVAL

CUSTOMER: ARCERA EU MODEL NO: 5115 (CeraDyna Fan) PART NO: FW2451-A1051C2AL DATE: CUSTOMER APPROVAL. Taiwan

CUSTOMER: MODEL NO: 4020III (CeraDyna Fan) PART NO: FD1240-A0241D0AL DATE: CUSTOMER APPROVAL. Taiwan. Approved QC Checked Checked Prepared

CUSTOMER: PART NO: FD1212-A1051E2AL. DATE : January CUSTOMER APPROVAL. Taiwan. Mainland China(F1)

CUSTOMER: 12038III (CeraDyna Fan) DATE : April 23, 2007 CUSTOMER APPROVAL

PREPARED 研發處 研發處 研發處 林佑亮 吳靜心 李群雪 AK1751HB DATE 研發處 P.S. AC FAN (RoHS) REV 發行章

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 40X40X10 mm M O D E L : KD1204PFS2-8

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 92X92X25 mm M O D E L : KD1209PTB1 P/N : (2).H

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS FAN. DIMENSIONS : 120X120X25 mm M O D E L : KD2412PTB1-6A

Product Data Sheet 4184 NXHH

Product Data Sheet 4414/2H

SUNON SPECIFICATION FOR APPROVAL DESCRIPTION : DC BRUSHLESS BLOWER. DIMENSIONS : 45X45X9 mm M O D E L : GB0545AFV1-8

Product Data Sheet 4184 NGX

Product Data Sheet 3214 J/2H3F-191

Product Data Sheet 4184 NXHH

Product Data Sheet DV5214 NU

Product Data Sheet 4118 N/ The engineer's choice

4314/17T. Product Data Sheet INDEX

Product Data Sheet DV4118 N

Product Data Sheet 8314 HR-197

Product Data Sheet 4184 N/17X. The engineer's choice

product specification

Product Data Sheet 3214 JH3-195

Product Data Sheet 624 NR. The engineer's choice

Product Data Sheet 632 NU-006

TF037C MICRO BLOWERS FEATURES STANDARD SPECIFICATIONS

Product Data Sheet 614 N/2HH-169 The engineer's choice

Product Data Sheet 8412 NHU-519

Product Data Sheet 8412 N/ The engineer's choice

Product Data Sheet 8414 NGH

High-force: 230 g. Projected 7.3 mm General-purpose: 160 g. High-force: 230 g. Flat 4.3 mm General-purpose: 200 g.

Brushless DC Axial Fans

Product Data Sheet ACi 4420 MLR

Specification Approval Sheet

Specification of Soneil Battery Charger MODEL: 5807SR 60V5A BATTERY CHARGER

Product Data Sheet ACi 4420 HHR

Specification of Soneil Battery Charger

Rated load current (resistive load) SRP. Min. 0.9 (max. 25 of difference between voltage phase and current phase)

100W Single Output Switching Power Supply NO TEST ITEM SPECICATION TEST CONDITION RESULT VERDICT

UNA SERIES Embedded Power Supply Features Model naming method UNA 350P / Applications UNA Conformity to RoHS Directive Product Line-up

Insulation method Zero-cross function Indicators Applicable output load Model number Phototriac coupler Yes Yes (See page 6) Main Circuit

Model Number Structure

PHOTOELECTRIC S300 PA MAXI SENSORS APPLICATIONS.

Inductive Proximity Sensor

Pressure Drop (Reference (typical)) 0.19 kpa 0.48 kpa Operating Temperature

Switching Power Supply

PSC Thermal Solutions. size 273 x 220 x202mm

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

350W Slim Type with PFC Switching Power Supply

Model Number Structure

2: A, B 3: A, B, Z 4: A, A _, B, B _ 6: A, A _, B, B _, Z, Z _

SAFETY INTERLOCK SWITCH CONSTRUCTED WITH DUAL RESTORATION SPRINGS FEATURES

Description General-purpose models Timer-function models Output NPN PNP NPN PNP Part number E3X-NH11 E3X-NH41 E3X-NH21 E3X-NH51 Appearance

Ordering Information. Text PCB Power Relay G5RL. Low-profile Relay with Various Models. Power Relays

SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005

(with Class-1 AC resistive load) 3. G3PB-215B-2N-VD kW max. (25 A) G3PB-225B-3N-VD 2. G3PB-225B-2N-VD kw max. (35 A) G3PB-235B-3N-VD 2

Climate Control Products

Specification of Soneil Battery Charger

VENT Series CENTRIFUGAL IN-LINE FANS VENT. In-Line duct fans. Mounting foot

PCB Relay. Contact form Terminals Coil terminals Rated voltage Model SPST-NO #250 tab terminals PCB terminals 5, 12, 24 VDC G4A-1A

High Accuracy Eddy Current Type Displacement Sensor GP-A SERIES. Resolution 0.04 % F.S., Linearity ±0.5 % F.S., IP67G environment resistance

Advanced Battery Charger 0 ~ 15A 0 ~ 25A 0 ~ 35A 0 ~ 50A 0 ~ 80A. 3 - stage charging capability (IUOU) 90 ~ 264VAC (refer to de-rating curve)

18091-PS. Preliminary General Specification PSM (AC) PES REV: PAGE. 1 of 8

Metal Oxide Varistor:TVR Series

UHP-350 series. 350W Slim Type with PFC Switching Power Supply

IN-LINE CENTRIFUGAL DUCT FANS VT Series

Single-pole 10A35VDC 0.8mm Contact Gap Power Relay : G5LE-G Single-pole 16A250VAC Power Relay : G5LE-E. Contact Form 10A 35VDC

Metal Oxide Varistor:TVR-M Series

WK25S WK20S WK10S WK12S WK08S WK06S. Thick Film Power Surge Chip Resistors AEC Q-200 Qualified Size 2512, 2010, 1210, 1206, 0805, 0603

FBA08A (80 X 25.5 L )

Metal Oxide Varistor Thermally Protected Type. TPV Series FEATURE PART NUMBERING SYSTEM LEAD CONFIGURATION SURGE CURRENT STANDARD WAVEFORM

DC2-Wire Unshielded Cylindrical Proximity Switches

SOLSTART Instruction Manual

MB Series AC Centrifugal Blowers

B3F. Miniature, Space-saving Switch

Type Contact form Enclosure ratings Model Standard SPST-NO (Class A) Flux protection G5LA-1A Sealed

Energy-saving motors (ESM)

Subminiature Basic Switch

BP- A Series Switch-Mode 3 Stage Battery Charger User s Manual

Metal Oxide Varistor:TVR-M Series

Non-Spring Return EconoDrive Floating Actuator

TC-500PD8. Switching Power Supply ( PS2 A T X 500W 8 0+ ) SPECIFICATION. Revision: 2.0

Motorized Butterfly Valve Actuated Wafer type butterfly valves

PG-30 PRESSURE GAUGES P G R - N FEATURES MODEL NUMBER DESIGNATION

UHP-500 series. 500W Slim Type with PFC Switching Supply

UHP-200 series. 200W Slim Type with PFC Switching Power Supply. File Name:UHP-200-SPEC GB4943 EN EN UL IEC

DC 2-Wire Unshielded Cylindrical Proximity Sensors. Operation mode. Setting indicator N.O. N.C. N.O. N.C. N.O. N.C. N.O. N.C. 20mm N.O. N.O. N.O.

Ordering Information. Text PCB Power Relay G5LE

韩国 Autonics 进口固态继电器型号模拟固态继电器 SRPH1 SRPH1 Series SSR 比例控制继电器选型说明书 pdf Single phase, Analog input type SSR Features Power control/ Cycle control/phase c

Advanced Battery Charger. 3 - stage charging capability (IUOU) 4.1 A / 100VAC 1.8A / 240VAC

Model Number Structure

Specification of Battery Charger

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

CENTRIFUGAL IN-LINE FANS VENT Series

D R C- 4 0 s e r i e s

POWER-WIN TECHNOLOGY CORP.

Safety Relay Unit. Ordering Information. Ideal for Safety Door and Emergency Stop Switch Circuits for Machines in European Countries

60W Constant Current Mode LED Driver. HBG-60 series. File Name:HBG-60-SPEC

Series AV. Pushbutton Switches NUT O-RING HOW TO ORDER

Transcription:

CUSTOMER: MODEL NO: 12038 (CeraDyna Fan) PART NO: FD1212-A2251G2AL DATE : June 9, 2010 CUSTOMER APPROVAL Taiwan ACT-RX TECHNOLOGY CORPORATION TEL: 886-2-82421111 2F, No. 192, Lien Chen Road, Chung Ho City, FAX: 886-2-82452200 Taipei, Taiwan, R.O.C. Approved by: Tiger 6/09 10 QC by: GuangYi 6/09 10 Checked by: Hua wei 6/09 10 Checked by: Zhi qiang 6/09 10 Prepared by: Hope 6/09 10 Page 1 of 11 REV.:X00

CONTENTS 1. SCOPE 3 2. ELECTRICAL 3 3. MATERIAL 4 4. MECHANICAL..4 5. EXPECTED LIFE SPAN (MTBF)..4 6. NOISE MEASUREMENT.....5 7. RELIABILITY. 6-7 8. PRODUCT LABEL...7 9. PERFORMANCE CHART..8 10. ASSEMBLY DIAGRAM....9 11. FREQUENCY GENERATOR (FG) SIGNAL OUTPUT..10 12. ORDERING AND OPERATING REMARKS 11 13.FAN PACKING DATA... 12. Page 2 of 12

1. SCOPE This document is a specification defining the electrical and mechanical characteristics of the product. 2. ELECTRICAL Standard operating condition is 25, 65%RH ambient, unless otherwise specified. Item Specification Test Condition 1 Rated Voltage 12V ±10% DC power supply 2 Rated Current 0.9 Amp (Typical) DC power supply at Rated Voltage 3 Max. Current 1.0 Amp(SafetyRegulation) DC power supply at Rated Voltage. This is for Safety Regulation. 4 Rated Power 10.8 W At Rated Voltage. 1 Sec. ON, 5 Sec. OFF At Rated Voltage when Rotor 5 Auto restart function cycling Locked 6 Starting Voltage 7V (Max.) DC power supply Input 500V(DC) between 7 Insulation Resistance 10 MΩ (Min.) Lead wire(+) and housing Measured at 5 minutes 8 Speed 3500 RPM ±10% after starting under 25±5, 65± 5%RH ambient Measured at typical speed with an acoustic microphone 1 meter away 61.7 db(a)(measurement from the fan intake in a test chamber 9 Acoustical Noise with background noise level below tolerance ± 2 dba) 18dB(A) under ISO-3745 Standard, refer to NOISE MEASUREMENT ITEM 7. Refer to PERFORMANCE CHART 11.31 mm-h 2 O ITEM 9 at zero airflow. 10 Static Pressure (0.45 inch-h 2 O ) This measurement is performed AMCA 210-99 Standard. Refer to PERFORMANCE CHART 170.78 CFM ITEM 9 at zero static Pressure. 11 Air Flow (4.84CMM ) This measurement is performed AMCA 210-99 standard. 12 Direction of rotation Counter-anticlockwise DC power supply, viewed from impeller. Page 3 of 12

3. MATERIAL Impeller Frame Bobbin Lead Wire 4.MECHANICAL PBT UL94-V0 PBT UL94-V0 PBT UL94-V0 +:Red :Black 24 UL 1007 AWG26 O/P: White Yellow 28 Dimensions L * W * H =120*120*38 (mm) Weight 200 grams Standard operating temperature range -10 ~ 75 Standard storage temperature -20 ~ 80 Bearing system 5.EXPECTED LIFE SPAN (MTBF) Two Ball Bearing One Ball One Sleeve Bearing Sleeve Bearing Alloy Sleeve with Ceramic Shaft Ceramic Bearing with Ceramic Shaft At a standard operating condition of 25±5, 65±5%RH ambient, the expected life(expressed as Mean Time Between Failure) of products are evaluated under MIL-STD-781 Standard as below : Two Ball Bearing:65000 hrs, Continuous operating under 25 65%RH One Ball One Sleeve Bearing:50000 hrs, Continuous operating under 25 65%RH Sleeve Bearing:30000 hrs, Continuous operating under 25 65%RH Alloy Sleeve with Ceramic Shaft:300000 hrs, Continuous operating under 25 65%RH Ceramic Bearing with Ceramic Shaft:500000 hrs, Continuous operating under 25 65%RH Page 4 of 12

6. NOISE MEASUREMENT: B & K 4190 Noise is measured under Rated Voltage in free air in the anechoic chamber with B & K Nexus 4350 conditioning amplifier, with B & K 4190 microphone at a distance of one meter from the fan intake. The background noise is 18dBA max under the ISO-3745 Standard. Page 5 of 12

7. RELIABILITY ACT-RX TECHNOLOGY CORPORATION Item Specification Test Condition Rotor locked for 72 hrs with Rated 1 Locked Rotor Test Flameproof and damage free Voltage 2 Reverse Voltage Test Protection 3 Balance Test 4 Drop Test 5 Vibration Test 6 High/Low Temperature Cycling 7 Low Temp. Storage 8 High Temp. Storage Yes No protruding beyond the circle within 10 seconds All specified characteristics remain unchanged All specified characteristics remain unchanged All specified characteristics remain unchanged All specified characteristics remain unchanged All specified characteristics remain unchanged Page 6 of 12 Reverse with Rated Voltage The fan runs in a circle, scaled by fan radius plus 10mm, on a perfectly smooth plate for 10 seconds under the ISO 1940 G6.3 grade Standard. Drop D.U.T.(The standard packing) from the test machine at 76cm below. Individual one angle, three diagonal corners and six planes under the ISTA-1A Standard. Ambient temp.:25 ºC±5 ºC with Rated Voltage Amplitude:0.4-2.5 mm Acceleration:14.7 S/m 2 Frequency:10HZ-60HZ Sweeping period:1 min 10HZ-60HZ:30 seconds 60HZ-10HZ:30 seconds Total:10 cycles This test is under the IEC 68-2-6 Standard. 20 minutes slew rate +75 ºC (1 hr), 10 ºC (1 hr) Total:36 cycles with Rated Voltage This test is under IEC 68-2-38 Standard. Tested under standard condition ;after 500hrs, -20 ºC storage, without power supply. This test is under IEC 68-2-1 Standard. Tested under standard condition ;after 500hrs, 80 ºC storage, without power supply. This test is under IEC 68-2-2

9 Dielectric Strength Max 1mA of leakage Current Standard. Input 500V(AC) for 1 sec between lead (+/-) and housing 8. PRODUCT LABEL Production monitored Type tested 26489 Page 7 of 12

9. PERFORMANCE CHART ACT-RX TECHNOLOGY CORPORATION This measurement is according to the AMCA 210-99 Standard. PQ curve for FD1212-A2251G2AL under Rated Voltage. Page 8 of 12

10.ASSEMBLY DIAGRAM ROTATION AIR FLOW *L General Dimension.Tolerances (Unit:mm) 0-3 ± 0.3 3-30 ± 0.4 31-60 ± 0.5 61-100 ± 0.6 101 and Over ± 0.6 Angles ± 2 Note : 1. L*:Lead wire length:60±10mm( 全長 250±10mm) (From frame edge) Page 9 of 12

11. FREQUENCY GENERATOR(FG) SIGNAL Output: 11.1 Output circuit:open collector mode Ic R Vcc (DC Vcc+10% Max.) Vce FG Signal 11.2 R=V/I (Out R value can be got by calculating) 11.3 Specification:Ic= 5mA Max. 11.4 Frequency Generator Waveform: 1 Rotation Vcc Vce (0.5V Max.) 5 Sec. 1 Sec. Shutdown Restart Driving Running Locked Rotor Running Page 10 of 12

12. ORDERING AND OPERATING REMARKS 12.1 Please indicate Part No. on every order. 12.2 For those not specified but vital to your requirement, ACT-RX is in full position to supply qualified substitutes. 12.3 ACT-RX does not guarantee the product if applications exceed specified limitations. 12.4 Please do not touch the impeller and never carry the fan the lead wires. The bearings and the lead wires may be damaged. 12.5 Please do not use the fan in the environment of corrosive gas or liquid. 12.6 Please do not store the fan in the environment of high humidity. Please avoid storage of the fan over 6 months. For long term storage, please connect power to the fan shortly every 6 months even through the fan is stored in room temperature. 12.7 Improper use may lead to malfunction. To ensure normal operation, avoid dipping the fan into watery and oily liquid, or exposing it to heat, etc. 12.8 Please do not lock the rotor for those fan models without Auto Restart function during operation to prevent over heating which may cause permanent damage. 12.9 Warrantee period is 12 months max. under the environment condition IP-20 specified in IEC60529. 12.10 All specifications subject to change without prior notice. Page 11 of 12

13.FAN PACKING DATA.4 P/N' Q'TY N.W G.W PCS KGS KGS MEAS 1.28 CUFT P/N' Q'TY N.W G.W PCS KGS KGS MEAS 1.28 CUFT Page 12 of 12