Linear Luminaire for Fluorescent Lamps Series EXLUX 6401

Similar documents
Linear Luminaire for Fluorescent Lamps Series EXLUX 6001

Emergency Light Fitting for Fluorescent Lamps Series 6009

Linear Luminaire with LED Series EXLUX 6002

Linear Luminaire with LED Series EXLUX 6402/2

Linear Luminaire with LED Series EXLUX 6002/2 Version IIC

Emergency Luminaire with LED Series EXLUX 6409/1

LED Linear Luminaire Series EXLUX 6402

Linear luminaire with LED Series EXLUX 6002

Emergency Luminaire with LED Series EXLUX 6009/1 Version IIC

Linear Luminaire for Fluorescent Lamps Series ECOLUX 6600

Linear Luminaire for Fluorescent Lamps Series ECOLUX METAL 6010/1

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Light Fittings for Fluorescent Lamps Series EXLUX 6000 / 6400

Compact Sheet-Steel Light Fittings Series 6114/1

Emergency Light Fitting for Fluorescent Lamps Series ECOLUX 6608 Economy

Emergency Light Fitting for Fluorescent Lamps Series EXLUX 6008 / 6408

7 Lighting Technology

Light Fitting for Fluorescent Lamps Series ECOLUX 6600

Compact Sheet-steel Emergency Light Fitting Series 6118/1

Linear Luminaire for Fluorescent Lamps

Sheet-Steel Light Fittings Series 6014 / 6414

Floodlight LED Series 6525

Floodlight LED Series 6125

Floodlight LED Series 6525

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Compact Emergency Light Fittings Series C-LUX 6108 / 6508

Emergency Light Fittings for Fluorescent Lamps Series ECOLUX 6608

Compact Sheet-Steel Light Fittings Series 6114

Floodlight Series 6121

Linear Luminaire with LED

Sheet Steel Emergency Light Fitting Series 6018

7 Lighting Technology

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Floodlight Series 6521/4

Plug and Socket Devices SolConeX 16 A Series 8570

7 Lighting Technology

Terminal Boxes Series 8125

Ex UPS standard Series 8265

Plugs and Sockets SolConeX & CES Series 7570, 7571, 7575, 7579, 7581

Load disconnect switch Series 8146/5-V11

Position Switches Series 8074/2

Zone 1 and Zone 2. Lighting Technology. Emergency Light Fittings Series EXLUX 6008

Position Switches Series 8060/2

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8581

Position Switches Series 8070/2

Terminal Boxes Series 8125

Control Buttons / Switches for Panel Mounting Series 8003

Tubular Light Fitting with LED Series 6036

Load and Motor Switches, Load-Break Switches Series 8549

2.4. Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps

Control switch/load disconnect switch Series 8008

Plugs and Sockets SolConeX & CES Series 8570, 8571, 8575, 8579, 8581

7 Lighting Technology

Load and Motor Switches, Load-Break Switches Series 8544

Zone 1 and Zone 2. Lighting Technology. Compact Emergency Light Fittings Series C-LUX 6108

7 Lighting Technology

Operating Instructions

Operating Instructions

Linear fluorescent luminaire LED V-CG-S

4.6. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 / FZD EN. (Zone 1, 2, 21, 22)

1/122 Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

Load and Motor Switches, Load-Break Switches Series 8544

E II 3 (1) G Ex na [ia Ga] IIC/IIB T4 Gc

Control Buttons Series 8082

Battery Boxes Series 8316

Safety Switches Series 8537

J: Emergency lighting (optional) L: pole type X: ceiling type Mounting

4.7. Ex-Floodlights for high-pressure discharge lamps, series FZD 04 (Zone 1, 2, 21, 22)

Pendant Light Fitting IEC

5.1. GHG 26 / EXKO 2.. Ex-Safety Switches Rated current from 10 A A

2.15. Ex-Linear luminaires for T5 HE fluorescent lamps. nllk W - 35 W (Zone 2 and 22)

Linear fittings EVDL LED fitting - zones 21, & 22

Linear fittings EVNL LED fitting - zones 2, & 22

HTSB system System overview

Tank Inspection Lights Series 6122

Wellglass fittings EVH, EVX Wellglass fitting all zones - zones 1, 2, 21 & 22

EX-REPAIR AND MAINTENANCE RECEPTACLES

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

EXENC-L. - Zone 2, Zone Low installation costs - Locking system operated by hexagonal-head tool - High quality electrical components

Control Device System NEC Series ConSig 8040

Linear fittings EVS fluorescent fitting with easy disconnect - zones 1, 2, 21 & 22

Ex-Floodlight PXLED. (Ex-Zone 1, 2, 21 and 22)

10 Load and Motor Switchgear

Versions. Version with K VS Version with K VS 2.0. Fig. 1: Type 3967 Solenoid Valve

Tubular fittings Tubular fluorescent fitting with automatic switch off XFP - Zones 1, 2 & 21, 22

Tubular fittings Tubular fluorescent fitting XFF - Zones 1, 2 & 21, 22

Linear fittings EVN Fluorescent fitting - zones 2 & 22

I 16A 2-pole up to 50 V I I 16A 3-pole up to 50 V I

I Ex-safety switches I

L: pole type. X: ceiling type. Lamp number Lamp wattage(w) Explosion-proof light fittings for fluorescent lamp BAY51-18 x 1L

4 Remote I/O. Enclosures for Fieldstations Series 8126 (Customer-Specific)

Power (W) Tamb 40 o C LX1GAM4LB57 5,700 10, T3 T100 o C T4 T85 o C 13

WELLGLASS EV.. Series - H.I.D. well glass lighting fixture. Aluminium with low content of copper. O-ring made of Nitrile Rubber (NBR)

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NE-HT / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

FHL. Ex d. Body in aluminium

EXEL-L. Detail of the internal side. Transparent polycarbonate

11 Control Panels, Distribution Panels and Components

Operating Instructions

ATX FE Series Nonmetallic Fluorescent Luminaires Standard and Emergency Battery Back-Up. Increased Safety

Transcription:

> As wall, ceiling and pendant light fitting or pole mounted light fitting > Version with 2 lamps: 18 W, 36 W and 58 W > Central locking > All-pole disconnection by means of an N/C switch when the lamp is opened (optional) www.stahl.de 15454E00 The luminaires of the series EXLUX 6401 can be used for general lighting as well as emergency lighting which is supplied with current via a group or central system. ATEX / IECEx Zone 0 1 2 20 21 22 For use in: x x x Explosion Protection Global (IECEx) Gas and dust IECEx PTB 14.0035 Ex na IIC T4 Gc Ex na d IIC T4 Gc Ex tb IIIC T80 C Db Ex tc IIIC T80 C Dc Europe (ATEX) Dust PTB 14 ATEX 2016 E II 2 D Ex tb IIIC T80 C Db Gas and dust PTB 14 ATEX 2017 E II 3 G Ex na IIC T4 Gc E II 3 G Ex na d IIC T4 Gc E II 3 D Ex tc IIIC T80 C Dc Certifications and certificates Certificates IECEx, ATEX WebCode 6401A Lighting /1

Selection Table Version Length Lamps Spring clamp terminal up to 4 mm Screw-type terminal Cable glands Art. no. Order number Weight mm kg EXLUX 6401 700 2x 18 W x Plastic M25 239552 6401/522-8508-1511 3.200 Metal M20 239555 6401/522-8508-1522 3.200 x Plastic M25 239558 6401/522-8508-2511 3.200 Metal M20 239561 6401/522-8508-2522 3.200 1310 2x 36 W x Plastic M25 239553 6401/542-8508-1511 5.500 Metal M20 239556 6401/542-8508-1522 5.500 x Plastic M25 239559 6401/542-8508-2511 5.500 Metal M20 239562 6401/542-8508-2522 5.500 1610 2x 58 W x Plastic M25 239554 6401/562-8508-1511 7.900 Metal M20 239557 6401/562-8508-1522 7.900 x Plastic M25 239560 6401/562-8508-2511 7.900 Metal M20 239563 6401/562-8508-2522 7.900 Order Number Supplement Through wiring without 6401/5..-.0..-... with 5 conductors 6401/5..-.5..-... ECG 220... 240 V 2-lamps AC, 1-lamp DC 6401/5..-...0-... 220... 240 V 2-lamps AC, 2-lamps DC 6401/5..-...1-... 110... 240 V 2-lamps AC, 1-lamp DC (only 18 W and 36 W) 6401/5..-...2-... 110... 240 V 2-lamps AC, 2-lamps DC (only 18 W and 36 W) 6401/5..-...3-... 220... 240 V 2-lamps AC, 2-lamps DC (standard) 6401/5..-...8-... Connection terminal Spring clamp terminal type WAGO 0.5... 4 mm 2 6401/5..-...-1... Screw-type terminal type STAHL 1.5... 6 mm 2 6401/5..-...-2... Cable glands Plastic 3 x M25 entries 6401/5..-...-..11 2 x M25 x 1.5 cable glands and 2 x M25 x 1.5 stopping plugs (enclosed) Plastic Metal Metal Metal 4 x M25 entries 2 x M25 x 1.5 cable glands and 2 x M25 x 1.5 stopping plugs (enclosed) 3 x M25 entries Cable gland and stopping plug Please order as accessories 4 x M25 entries Cable gland and stopping plug Please order as accessories 3 x M20 entries Cable gland and stopping plug Please order as accessories 6401/5..-...-..31 6401/5..-...-..12 6401/5..-...-..32 6401/5..-...-..22 Metal 4 x M20 entries Cable gland and stopping plug Please order as accessories Note The lights are delivered without fluorescent lamps and assembly parts. These parts must be ordered separately! 6401/5..-...-..42 /2 Lighting

Technical Data Electrical data Ballast 6401/...-...0-... 6401/...-...1-... Lamp start Cold start Cold start Voltage 220... 240 V AC 220... 240 V AC DC voltage in 198 264 V DC 198 264 V DC case of ignition DC voltage 176 264 V DC 198 264 V DC during operation Frequency 0 / 50 60 Hz 0 / 50 60 Hz Lamp operation 1-lamp 2-lamp DC Lamp standard IEC 60081 IEC 60081 Lamp power 18, 36, 58 W 18, 36, 58 W Nominal current 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma 1 x 18 W, 85 ma 2 x 18 W, 170 ma 1 x 36 W, 160 ma 2 x 36 W, 320 ma 1 x 58 W, 250 ma 2 x 58 W, 500 ma 6401/...-...2-... 6401/...-...3-... 6401/...-...8-... Lamp start Cold start Cold start Cold start Voltage 110... 240 V AC 110... 240 V AC 220... 240 V AC DC voltage in 104 264 V DC 104 264 V DC 198 264 V DC case of ignition DC voltage during 104 264 V DC 104 264 V DC 176 264 V DC operation Frequency 0 / 50 60 Hz 0 / 50 60 Hz 0 / 50 60 Hz Lamp operation 1-lamp 2-lamp 2-lamp DC Lamp standard IEC 60081 IEC 60081 IEC 60081 Lamp power 18, 36 W 18, 36 W 18, 36, 58 W Nominal current 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma 1 x 18 W, 85... 175 ma 2 x 18 W, 170... 345 ma 1 x 36 W, 155... 330 ma 2 x 36 W, 310... 660 ma 1x18W 80mA 2x18W 150mA 1x36W 160mA 2x36W 300mA 1x58W 250mA 2x58W 480mA Power factor cos p Disconnection of the light End of life switch Luminous characteristics Lamps cos p ) 0.97 capacitive; no additional compensation required When opening the luminaire Switch with safety lock (optional); when opening the central lock all poles of the voltage supply to the ballast are disconnected; contacts of the switching element are positive opening, they can only be switched on again when the translucent cover and the central locking system are closed. in case of a lamp failure, the electronic ballast disconnects the defective lamp from the power supply. If the 2-channel EB is used the channel of the defective lamp is switched off, but the channel using the intact lamp remains operational. 18 W 60081-IEC-2220 G13 36 W 60081-IEC-2420 G13 58 W 60081-IEC-2520 G13 Please use cold start lamps. Lighting /3

Technical Data Ambient conditions Operating temperature range The lowest ambient temperature when used with breather is -20 C. Mechanical data Degree of protection IP66 (IEC 60598) Protection class I (with internal PE connection) Material Enclosure Enclosure Polyester resin, glass fibre-reinforced Colour colour grey, similar to RAL 7035 Translucent cover Polycarbonate Gasket Silicone foam gasket in the lamp cover Luminaire locking Central locking which can be opened/closed using a socket key M8 / wrench size 13, hinged lamp cover Mounting / Installation Cable glands Standard luminaire Plastic: 2 x M25 x 1.5 cable gland 8161 and 2 x M25 x 1.5 stopping plugs 8290 (enclosed) Metal: 2 x metal plates M20 x 1.5 connected by means of PE for metal cable entries Attention: cable entries must be ordered separately Special: max. 4 bores for M20, M25, NPSM ½ max. 2 bores for NPT ¾ Metal cable glands: M20 x 1.5, M25 x 1.5; earthing of the metal cable entries by means of metal plates Connection Through wiring Through wiring Type without with 6401/52.-...0-... -30 C... 60 C -30 C... 50 C 6401/52.-...1-... -30 C... 60 C -30 C... 50 C 6401/52.-...2-... -30 C... 45 C -30 C... 40 C 6401/52.-...3-... -30 C... 45 C -30 C... 40 C 6401/52.-...8-... -30 C... 60 C -30 C... 50 C 6401/54.-...0-... -30 C... 55 C -30 C... 50 C 6401/54.-...1-... -30 C... 55 C -30 C... 50 C 6401/54.-...2-... -30 C... 45 C -30 C... 40 C 6401/54.-...3-... -30 C... 45 C -30 C... 40 C 6401/54.-...8-... -30 C... 55 C -30 C... 50 C 6401/56.-...-... -20 C... 55 C -20 C... 50 C Standard: Special: Through wiring without Spring clamp terminals 5-pole: L1, L2, L3, N, PE Clamping range: 1 x 0.75... 4 mm 2 (solid / finely stranded) 4 mm 2 finely stranded without core end sleeve only (2 free clamping units for each pole available) Terminal block with covering 5-pole: L1, L2, L3, N, PE Clamping range: 2 x 1.5... 6 mm 2 (solid); 2 x 1.5... 4 mm 2 (finely and extra finely stranded) Standard luminaire Luminaires are equipped with internal through wiring. Ingoing and outgoing leads can be connected on the opposite sides. Terminals: see Techn. data Wiring cross-section: 2.5 mm 2 for max. 16 A Optional On the connection side, there are 2 bores M25 x 1.5 for cable entries for ingoing and outgoing wiring of the connection line (ingoing and outgoing leads on one side). Assembly For outdoor mounting, a breather is recommended Standard luminaire Standard: 2 x M8 insert nuts in the enclosure Special: Mounting grooves in the enclosure for the use of fastening and ceiling rails for variable luminaire mounting (variable mounting distances for luminaires 18 W: 320... 480 mm; 36 W / 58 W: 670... 930 mm) /4 Lighting

Light distribution curves 180 200 160 120 80 180 160 120 80 45 30 15 0 15 30 45 45 30 15 0 15 30 45 cd/klm 83% C0 - C180 C90 - C270 cd/klm 77% C0 - C180 C90 - C270 16697E00 16698E00 2x 18 W 2x 36 W 180 160 120 80 45 30 15 0 15 30 45 cd/klm 75% C0 - C180 C90 - C270 2x 58 W 16699E00 Lighting /5

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Fluorescent lamps 18 W 1350 Im 108952 0.100 04936E00 36 W 3350 Im 58 W 5200 Im 108951 0.200 108950 0.220 Bracket for wall mounting with tube Two-pin cap d 26 mm Light colour: universal white Pins made of brass for side entry lamp; with tube, length 400 mm, d 42 mm 108947 2.480 05460E00 Lamp cover for luminaire L=700 222427 0.639 for luminaire L=1310 222428 1.149 for luminaire L=1610 222429 1.450 Lamp-holder Lamp holder for two-pin cap lamps G 13 107275 0.008 Switch 05888E00 Switching element 8080/1-3-L, 2 normally closed contacts 132527 0.025 10809E00 Socket key M8 / wrench size 13; to open/close the central locking 222430 0.210 15507E00 Adapter plates 1 x M20 x 1.5 1 piece 115815 0.070 1 x M25 x 1.5 1 piece 115818 0.070 05755E00 1 x NPSM 1 / 2 1 piece 115821 0.070 1 x NPT 3 / 4 1 piece 115824 0.070 2 x M20 x 1.5 1 piece 115826 0.060 2 x M25 x 1.5 1 piece 115828 0.060 2 x NPSM 1 / 2 1 piece 115829 0.060 for use together with metal cable glands; the metal cable glands are integrated in the earthing system via adapter plates Mounting rail for a variable mounting distance 1 pair 222826 0.300 15584E00 Mounting bracket mounting clamp mounted on a mounting rail for a variable mounting distance 1 pair 222456 0.400 15585E00 /6 Lighting

Accessories and Spare Parts Designation Figure Description Art. no. Weight kg Pole mounting sleeve for the subsequent mounting on lights 18 W and 36 W, 227512 3.300 completely with assembly parts 16985E00 Pipe clamp R 1 1 / 2 222459 1.200 R 1 1 / 4 222458 1.250 R 2 222460 1.300 15583E00 with mounting rail for a variable mounting distance; Material: stainless steel 1 pair Ring bolt M8, direct mounting in insert nuts 1 pair 115736 0.120 05378E00 Breathing gland M25 x 1.5 in order to avoid condensate formation 115738 0.020 05703E00 Ceiling and wallmounting bracket 1 pair 222827 2.400 15586E00 mounted on a mounting rail for a variable mounting distance; Material: stainless steel Lamp can be swiveled in steps of 15 Dimensional Drawings (All Dimensions in mm [inch]) - Subject to Modifications b L1 L2 M25 x 1,5 L3 M25 x 1,5 h1 Dimensions Luminaire 17/18 W 32/36 W 40/58 W L1 700 [27.56] 1310 [51.57] 1610 [63.39] L2 1) 400 [15.75] 800 [31.50] 800 [31.50] L3 2) 320... 480 [12.60... 18.90] 670... 930 [26.38... 36.61] 670... 930 [26.38... 36.61] b 184 [7.24] 184 [7.24] 184 [7.24] h1 125 [4.92] 125 [4.92] 125 [4.92] 1) fixed mounting distance 2) variable mounting distance EXLUX 6401 Standard luminaire 15440E00 Lighting /7

Dimensional Drawings for Assembly Parts and Accessories (All Dimensions in mm [inches]) - Subject to Alterations 12 [ 0, 47 ] 18,50 [ 0, 73 ] 30 30,50 [ 1, 20 ] 215 [ 8.46] [1,18]. 9 [0,35] 193-198 [7,60-7,80] 124 [ 4, 88] 11 [ 0, 43] 86 [ 3, 39] 74 [ 2, 91] 32 [1,26] 6,10 [0,24] ø 6,10 ø 8,10 9 [ø. 0, 24] [ø 0,32] [0,35] 13 [0,51] 215 [ 8, 46] 193-198 [7,60. - 7,80]. 143 [5,63] 15778E00 15779E00 Mounting rail ø 20 [ø 0,79] 24 [0,95] ø 42 [ø 1 1/4] ø 48 [ø 1 1/2] ø 60 [ø 2] 162 [6,38] 172 [6,77] 180,50 [1 1/4] 187,50 [1 1/2] 200,50 [2] Ring bolt fitted in insert nut of the luminaire 15782E00 15781E00 15783E00 Mounting bracket fitted in mounting rail Pipe clamp fitted in mounting rail 10x15 A 296 [11,65] 42 [ 1,65] ø 10,50 [ ø 0,41] 15 400 [15,75] A [1,39] 34 65,50-74,50 [2,58-2,93] 110 [4,33] 8,50 [0,35] 8,50 [0,35] Wall mounting bracket fitted in mounting rail 15780E00 198 [7,80] 160 [6,30] 120 [4,72] 143 [5,63] 104 [4,09] 130 [5,12] 220 [8,66] SW 5 20 [0,79] 180 [7,09] Bracket for wall mounting with pipe section 03257E00 We reserve the right to make alterations to the technical data, weights, dimensions, designs and products available without notice. The illustrations cannot be considered binding. /8 Lighting