EG3000. Generator Electronic Governor Controller Operation Manual

Similar documents
ESC2301. Universal Electronic Governor Controller Operation Manual

EG1069X. Generator Electronic Governor Controller Operation Manual

EG1065X. Compatible with Barber Colman* Dyn1-1065X series * Use for reference purpose only and not a genuine Barber Colman product.

EG3002. Electronic Engine Governor Controller User Manual

DYNA Power Control Manual For Plus 1, Plus 2, Plus 4 and Plus 6 Ft. Lb. Systems

ESD5500E Series Speed Control Unit

ESD5550 / 5570 Series Speed Control Units

ENGINE GOVERNING SYSTEMS

ESD5100 Series Speed Control Unit PART NUMBER ESD5120 ESD (127)

PRODUCT SERIES: DPG-2100

DYNA 8000 DYNA 8200 DYNA

Application Information

ESD-5550/5570 Series - Speed Control Unit

with discrete output (Overspeed) with auxiliary input (Synchronizer and Load Sharing)

Product Manual (Revision E) Original Instructions. Min/Max Control Systems. Installation and Operation Manual

IGA225 Integrated Governor & Actuator

ESD-5550/5570 Speed Control Unit. Manual

Product Manual (Revision B) Original Instructions. EPG Electrically Powered Governor Models 501 and Installation and Operation Manual

INSTRUCTION MANUAL FOR VOLTAGE REGULATOR APR P/N

EDG6000 Electronic Digital Governor

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

10V. the rack of the oil pump must be on the

ESD-5500E Series - Speed Control Unit

ADVR-12. Hybrid Universal Analog Digital Voltage Regulator Operation Manual

EDG5500 Electronic Digital Governor With Quikset Display

MX431 Generator Automatic Voltage Regulator Operation Manual

INSTRUCTION MANUAL FOR. VOLTAGE REGULATOR Model: APR Part Number:

Product Manual (Revision C) Original Instructions. EPG (Electric Powered Governor) with Position Feedback. Installation and Operation Manual

2301A Load Sharing & Speed Control with Dual Dynamics. Product Manual (Revision NEW, 1990) Original Instructions

4024 EPG (Electrically Powered Governor) Product Manual (Revision B, 3/2008) Original Instructions

Product Manual (Revision D, 5/2015) Original Instructions. 2301A Speed Control. Installation and Operation Manual

PM300 VOLTAGE REGULATOR INSTRUCTION MANUAL

EA07. Generator Automatic Voltage Regulator Operation Manual

ENGINE GOVERNING SYSTEMS LSM672 LOAD SHARING MODULE. GOVERNORS AMERICA CORP. 720 Silver Street Agawam, MA , USA MEMBER

AVR Hybrid Universal Analog Digital Voltage Regulator Operation Manual

TRAC-3 TENSION READOUT AND CONTROL

Application Note. Controllers for Stanadyne Pumps Using DC Integrated Actuators. Calibration Instructions. Manual 36579

Application Information

ES52. Auto Start Engine Controller. Full Version. Installation and User Manual for the ES52 Auto Start Engine Controller.

PED 5000 ELECTRIC ACTUATOR

EPG Electrically Powered Governor. Installation and Troubleshooting Manual. Models 1712/1724 and 512/524 without Position Feedback

UNIVERSAL VOLTAGE REGULATOR Manufactured in the USA by

UG-5.7, UG-8, UG10 Governor

PM300E Voltage Regulator Instruction Manual

Installation & Operation Manual

EA16. Generator Automatic Voltage Regulator Operation Manual

MAGNAMAX DVR DIGITAL VOLTAGE REGULATOR

GS10 Series MODELS: GS10 GS10-R NEMA 4X SCR MOTOR CONTROLS. User s Manual

ES52 Auto Start Engine Controller Installation and User Manual for the ES52 Auto Start Engine Controller.

EEG6500 Enhanced Electronic Governor

CN0055 & CN0055B DC to DC NEGATIVE RESISTANCE SPEED CONTROL

500 Series Troubleshooting Guide for C520 Alternators

Troubleshooting Guide

PRODUCT INFORMATION BULLETIN

ELECTRONIC MANUAL VOLTAGE CONTROL Model: MVC 300. Part Number:

SPECIFICATIONS ATTENTION OPERATION DESCRIPTION

DC Variable Speed Drive Panel

ECU. Speed Switch Manual. Contents. ECU is a registered trademark of Engineering Concepts Unlimited Inc.

Troubleshooting Guide

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

RODIX, INC. FC-40-PLC Plus Series Control Troubleshooting Guide for Circuit Board P/Ns and

Servo and Proportional Valves

715B CONTROL SERIES. Instruction Manual Line Voltage DC Brushless Motor Control CONTROLS. Phone (317) Fax (317)

Tachometer, Ametek Electronic 54.21

EEG6550 Enhanced Electronic Governor

Fincor Series 2230 MKII/2240

5001TCP SPEED CONTROLLER

Controlled Ferroresonant Ballast (CFB) Generation #3. Manual

USER MANUAL MODELS NRG02-D240AC-4Q NRG02-D240AC-4Q-PCM NRG05-D240AC-4Q NRG05-D240AC-4Q-PCM NRG10-115AC-4Q NRG10-115AC-4Q-PCM

Product Manual (Revision D, 3/2000) Original Instructions. UG-5.7, UG-8, UG10 Governor. Installation Manual

th Street, Surrey, B.C. Canada V3W 0A6 Telephone Fax July 2012

DPD72PG1 BILEVEL STEP MOTOR DRIVER PACK With RAMPING PULSE GENERATOR

USER'S MANUAL MODEL DPS32PG1 DRIVER PACK

5001TCP SPEED CONTROLLER

Tachometers and Tach/Hourmeters

Installation Instructions

N1240/N1243 Series Troubleshooting Guide for N1240-3/N Alternators

POWER SUPPLY MODEL XP-800. TWO AC VARIABLE VOLTAGES; 0-120V and 7A, PLUS UP TO 10A. Instruction Manual. Elenco Electronics, Inc.

Operation and Installation Manual

ATB Series - Integral Throttle Body Actuators

17429X.00 SERIES MODELS:

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

BLDC SPEED CONTROL INSTRUCTION MANUAL Line voltage Brushless DC control

Filtered PWM Speed Control for Permanent Magnet DC Motors

225 SERIES ELECTRIC ACTUATOR

Tri-Spark Ignition System Installation Triple Cylinder TRI-0001

oubleshooting Guide diesel - gasoline - LPG electric P.O. Box 1160 St. Joseph, MO Fax:

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

INSTRUCTION MANUAL FOR

Installation and Operating Instructions Electro-Pneumatic Rotary Positioner SP-21. Description of Device. Part Number System

R81EAA-2 Economizer Circuit Board

Damper Actuator Installation

DENISON HYDRAULICS Jupiter 500 Driver Card Series S

12 Series Linear Actuators. Operation & Maintenance Manual, Analog Positioner Installation

CUMMINS SPEED CONTROLLER DATASHEET

Product Manual (Revision A, 8/2015) Original Instructions. ProAct II Digital Speed Control System. Technical Supplement

Model No. SB1B-14 Linear Standby Regulator. B & C Specialty Products P.O. Box B Newton, KS (316)

MDC Series

Flowrite EA 599 Series SKD Electronic Valve Actuator 24 Vac Proportional Control

System 350 S350P Proportional Plus Integral Temperature Stage Module

Transcription:

EG3000 Generator Electronic Governor Controller Operation Manual Smoke Limit Control, Idle Speed Control, suitable for Builtin, Non-Built-in and PT Pump Type Actuator. SP POWERWORLD LTD Willows, Waterside, Ryhall, Stamford, Lincs, PE9 4EY, UK Tel: +44 1780 756872 - Email: info@sp-powerworld.com www.sp-powerworld.com

1. SPECIFICATIONS 1.1 Electronic Specifications Operating Voltage 12 or 24 VDC ±20% Output Current 0.5 ~ 15 A Run Speed Adjustment range Speed adjustment Potentiometer (30 turn) 4 Segment Dip Switch Adjustable From 600 ~ 9500 Hz. Idle Speed Adjustment Range Run Speed 30 ~ 85% Ramp Time 3 ~ 20 Sec Remote Speed Pot Ext. Remote speed pot terminal 6, 7, 8 (ILS) and 6, 7, 9 connect a 5KΩ potentiometer ±5% adjustment range. Temp. Stability <0.01% Run Speed Stability ± 0.25 % at steady state MPU input signal 1 ~ 120VAC RMS Droop 4% Adjustment Run Speed, Idle Speed, Ramp Time, Droop, Gain, Integration, DIF Mechanical Vibration 1G @ 18 ~ 30 Hz, 2.5G @ 48 ~ 70 Hz Relative Humidity < 95% Operating Temperature -40 ~ 85 Storage Temperature -40 ~ 85 Dimensions 147mm L * 114mm W * 50mm H Weight 690g ± 2% 2 Function Descriptions The EG3000 provides both an adjustable Idle Speed and ramp, for controlling engine smoke, vibration and warm-up. With the correct DIP SW setting, the governor will achieve stable operation for external, built-in and PT pump type actuators. 2.1 Controller Together, the EG3000 Controller, Actuator and MPU (Magnetic Pickup) form the electronic engine governor assembly. The EG3000 receives the signal from the MPU and, depending on the engine RPM, the actuator controls the fuel intake on the engine. The EG3000 receives its power from the engine batteries or an AC to DC power supply rated from 12 or 24 VDC ±20% matching the Actuator voltage. The average operating current is around 2.5 to 3.5 amps, but it may reach 15 Amps during engine start or sudden load changes. 2.2 Installation Descriptions 1. Protect the EG3000 by installing it inside the engine instrument control panel. 2. Mount the Actuator close to the engine fuel system. See actuator manufacture instructions. 3. Always choose a point on the actuator control arm in which it can rotate freely, providing minimum and maximum fuel (But do not bottom out the actuator; leave 2 to 3 degrees before the off and on position). 4. Use a Non-Linear link on Gas engines to get low Gain at light loads and high Gain at heavy loads and a linear link on diesel ejection pumps. 2 EG3000

5. Mount the magnetic pickup on the flywheel bell housing to count the teeth on the ring gear. The teeth are converted to an electrical pulse by the MPU. These pulses are cross referenced with the original setting on the EG3000. Any difference is used by the actuator to change engine RPM to maintain the same pulse count. 3. CONNECTION Terminal 1, 2 DC Power Input 2, 3 IDLE Terminal 4, 5 For ACT, Max @ 15A 6, 7, 8 Remote speed control. Connect 5KΩ potentiometer approx. 6, 7, 9 ±5% adjustment range. 10, 11 MPU input, Ground Terminal No. 10 1. Terminal 1 & 2 used for DC power input. Terminal 1 for Positive (+) and Terminal 2 for Negative ( ) input -Voltage can be 12/24VDC ±20%. 2. Terminal 2 & 3 are the IDLE SW. Terminal when 2 & 3 open normal Run Speed, When Terminal 2 & 3 shorted engine in Idle. 3. Terminal 4 & 5 is the output terminal for the actuator, providing a maximum of 15A. 4. Terminal 6 and 7-8 and terminal 6 and 7-9 are two sets of remote speed control. Referring to figure 4, connect a 5KΩ potentiometer, and turn the knob to central position. Let engine run on Run Speed to adjust to the rated engine speed, the adjustable range is ±5%. Users can also series a resistor to the potentiometer variable point to either terminal 8 or 9 to narrow the adjustable range. The wirings used to connect to terminal 6, 7-8 and 6, 7-9 must use the 3-wire shielded cable. The drain shield wire is to be connected to terminal 10 and the other end of the drain shield wire must cut off and taped. 5. Terminal 10 and 11 is the MPU signal input terminal. The wiring used to connect to the terminals must use a 2-wire shield cable. The drain shield wire is to be connected to Terminal 10 and the other end of the drain shield wire must cut off and taped. 6. Harness used to connect to Terminal 1, 2, 4 and 5 must use the 2.0mm twist pair harness. 4. OPERATION 4.1 Idle Speed and Smoke Limiting Adjustment The EG3000 has two settings used for smoke limiting : 1. Idle Speed The setting of the lowest engine operating speed. Before firing the engine, adjust the Idle Speed to the maximum, and Ramp Time to the minimum. Adjust Run Speed to minimum and let Terminal 2 & 3 be Open Circuit. Start engine. The engine speed may rev to Run Speed right away. Slowly adjust Run Speed to the rated generator RPM. Short Terminal 2 & 3 the engine speed should drop, slowly set Idle Speed to a comfortable engine idle. Stop engine and adjust Ramp. Time to it center setting then restart engine. At this time, the engine speed will stay in Idle and slowly Ramp up to normal engine speed. Adjust to preferred Ramp speed. Refer to Figure 1. When operating at normal RPM closing the IDLE SW, decreases engine RPM back to idle RPM according to preset Ramp Time. To ensure positive engine starts every time follow step (4) and turn the Idle Speed potentiometer an additional 3 to 5%. 2. Ramp Time. On hot engines, a specific fuel limit setting will control start-up smoke, but not completely. A hot engine does not need the same fuel limits to start as a cold starting engine. Ramp Time can be set from 3 up to 20 seconds. The Ramp Time is the length of time from Idle to the rated Run Speed. Figure 1 EG3000 3

4.2 Isochronous Adjustment Isochronous operation is obtained by setting Droop potentiometer fully counterclockwise. EG3000 is normally operated in the isochronous mode; i.e., engine RPM is constant (±0.25%), under steady state load conditions, up to the engine s maximum capability, regardless of load on the engine. Please refer to Figure 2. 4.4 Remote Speed POT Adjustment EG3000 is equipped with 2 sets of Remote Speed Potentiometer adjustment. By adding a 5KΩ Potentiometer, user can adjust the engine speed from as far as 60 meters away from the engine. Please refer to Figure 4 for connection. To narrow the adjustment range, series a resistor on either Terminal 8 or 9 to reduce. Without the resistor the adjustment range is approximately 5%. 4.5 INT, GAIN, DIF Adjustment Figure 2 4.3 Non-isokinetic Operation When operated under Non- isochronous (Paralleled), Droop is used to distribute the actual power from the generators. Please refer to Figure 3. Droop operation is obtained by setting the Droop potentiometer. Moving Droop Pot clockwise increases the Droop. The amount of Droop for a given setting depends on the magnetic pickup frequency and no load to full load actuator shaft rotation. 1. Shutdown engine and DC input turned off. 2. Potentiometer original setting. 3. Adjust INT., Gain, DIF, and Ramp Time Potentiometer to minimum setting (Fully Counterclockwise) 4. Under Isochronous operation, set Droop potentiometer fully counterclockwise. 5. Set the MPU frequency range : Select the suitable frequency setting according to the highest engine frequency range Input Signal Frequency : SW-1 ON SW-2 ON SW-3 ON SW-4 ON RPM Flywheel teeth 60 sec Frequency Selection 600 ~ 1200Hz 1200 ~ 2500 Hz 2500 ~ 5000 Hz 5000 ~ 9500 Hz (If uncertain Set SW3-ON and the balance to OFF) Figure 3 6. Idle Speed set to maximum, Run Speed set to minimum 7. Adjust Remote Speed POT to central (If used) 8. Start Engine At this time the engine should rev to Run Speed, (If engine speed exceeds its rated speed, Stop engine and immediately choose a lower frequency setting) slowly adjust Run Speed pot clockwise to the rated engine speed. A Droop potentiometer setting of 10 o clock will give For Idle Speed, Ramp Time And Idle Sw Setting, about 4% Droop, no load to full load when the Reference To Paragraph 4.1 pickup frequency is 4600Hz and actuator shaft rotation is approximately 30 degrees from no load to 9. Slowly adjust Gain clockwise until the actuator full load. Lower pickup frequency or smaller shaft begins to oscillate. rotation results in less Droop for the system. 10.Slowly adjust Gain counterclockwise until it becomes stable. 4 EG3000

11.Manually move the linkage. If the linkage oscillates 3 to 5 times and then stabilizes, then the setting is correct. 12.If engine speed overly increases or decreases when adding load or reducing load, please adjust the Gain VR clockwise a little. 13.If engine speed recovers too slowly, adjust INT. (Integration) clockwise, in the same time decrease the GAIN setting. Observe the actuator linkage. If the linkage is stable, manually adjust the linkage. If the linkage slowly oscillates, then the response time is inadequate. Adjust INT. clockwise until the response is improved. 14.After completing the above steps, slowly adjust DIF clockwise until engine speed begins to oscillate then slowly adjust counterclockwise to stable critical point / knee point. * Knee point is the position where the adjustment is at the point of stable and edge of unstable. 5. DIMENSION AND TYPICAL WIRING DIAGRAM 15.Slowly adjust GAIN clockwise until engine speed reach the stable critical point / knee point. 16.Again manually adjust the linkage. If the linkage begins to oscillate 3 to 5 times and then stabilizes, then the setting is complete. 17.Set SW-5-ON will decrease the effect of GAIN and make suitable for PT-PUMP type actuator. Please reference from 4.2 and 4.3 for Droop setting. Note 1:If GAIN or DIF is over adjusted, it causes the engine speed to oscillate. Repetitively increasing and decreasing the GAIN and INT. arrangement can help to obtain the best performance. Note 2 : Due to different types of external and internal built-in type actuators, the adjustment of Gain is very important, together with INT. (Integration) adjustment. In PT pump type actuators, the movement is very limited, so Gain is set to the minimum using INT. (Integration),DIF to adjust engine speed compensation. DROOP DIF. INT. GAIN RAMP SW POWER : DC12/24V SW1-ON 600~1200HZ SW2-ON 1200~2500HZ SW3-ON 2500~5000HZ SW4-ON 5000~9500HZ SW5-ON PT-PUMP + IDLE 1 2 3 IDLE SPEED REMOTE SPEED POT RUN SPEED ~ ILS ACT 4 5 6 7 8 9 10 MPU 11 Idle switch Cable A Cable B + _ DC Power Actuator R Magnetic Pickup CCW 5K CW Wiring Drawing Figure 4 * Cable A, B - use a cable with a wrapped Mylar aluminum foil shield with a drain wire. * To connect the 5KΩ potentiometer, refer to paragraph 3. Connections. 1. To connect the DC power supply and actuator use a 12 AWG / 2mm twist pair harness. 2. Connect the MPU to the EG3000 using a 2-wire shielded cable. Anchor the drain shield wire to Terminal 10 and the other end cut and tape off. EG3000 5

5. TROUBLESHOOTING PROBLEM Actuator goes to full stroke when DC power is turned on (Engine is not operating) Governor is completely dead and actuator lever stays at minimum position when power is applied to governor. CORRECTIVE ACTION 1. Check magnetic pickup leads for proper shielded wire or open shield. Verify and correct wiring as necessary. Be sure there is no jumper between terminals 2 and 3. 2. Failsafe circuit in the controller may be damaged or defective. Replace with new controller. 3. With DC power OFF remove leads at actuator. Check continuity of conduction on each terminal to case. There should be no continuity of conduction between any terminal and case of EG3000. If conduction is measured, please replace the controller. 4. If remote speed potentiometer has been connected to terminals 6, 7 and 9 of the controller, disconnect these leads. Turn DC power ON to the governor if the actuator is now normal. Proceed to corrective actions for the next problem. 1. Check battery voltage at terminals 1 and 2 on controller. Terminal 1 is positive. Check battery connections and contacts for turning power ON to the controller. 2. Check for proper linkage setup. Correct and free linkage. 3. Magnetic pickup signal absent or too low. Measure AC voltage across terminals 10 and 11 while cranking the engine. Voltage should be min. 1.0 VAC. NOTE: The voltmeter should have an impedance of 5000 ohms / volts or higher. Check pole tip gap over gear tooth. Should be 0.037 mm ~ / - 0.127 mm. 4. Measure the resistance of the magnetic pickup coil. This should be above 50 ohm. If there is an open or shorted coil, replace the magnetic pickup. 5. Measure the resistance of each pin to the metal case of the magnetic pickup. No continuity should be evident. 6. If there is continuity of conduction to the case, replace with new magnetic pickup. 7. Measure actuator coil resistance: If actuator coil is open or shorted to case, replace the actuator. If governor still does not operate, continue with steps below. 8. Measuring the resistance of each coil lead to the actuator case should indicate an open circuit on a low scale of the ohm meter. If continuity is defected, replace the actuator. 9. With DC to the governor ON and the engine OFF, measure the DC voltage from terminal 6(+) to terminal 2(-). This should be approx. 4VCD. If 4 VCD is not present, replace the controller. 10.Between terminal 7(+) and terminal 2(-), the voltage should be approx. 4.6 VDC. If 4.6VDC is not present, replace the controller. 6 EG3000

PROBLEM Erratic governor operation Improper operation from remote speed potentiometer Slow, small amplitude hunting of speed or frequency Fast oscillation of governor linkage Engine will not start Actuator goes to full fuel during cranking CORRECTIVE ACTION 1. Measure DC voltage at 1 and 2 on controller terminal strip. Normal battery voltage should be indicated. If nominal voltage is present, wiring is correct. 2. Low battery voltage 20% below rated can cause erratic operation. Check battery and charging system. 3. RFI noise due to incorrect shielding. Correct wiring. 4. RFI noise fed through power supply leads. Connect power leads directly to the battery. 1. Investigate wiring to remote speed potentiometer for open or shorted circuits. Checking wiring. 2. If the leads at terminals 6 and 7 to the remote speed potentiometer are reversed, speed control by the remote speed potentiometer will be reversed. Correct wiring. 3. Lead wire to remote speed setting potentiometer should be 3-wire shielded cable. Verity that the drain shield wire is isolated from ground at the potentiometer. If terminal 6 lead to the remote speed potentiometer is open, engine speed will go high. Correct the wiring. 4. If lead 8 and 9 (wiper lead to remote potentiometer) is open, there will be no control by the remote speed potentiometer. Verify and correct wiring. 5. If lead 7 to the clockwise terminal of the remote speed potentiometer is open, speed will remain at the value set in EG3000. Jammed or very loose linkage. Correct linkage. Verity calibration setting of the controller. Readjust setting as necessary. 1. Make sure fuel is available. Check fuel to engine. Check for correct wiring to the automatic shutdown circuits. 2. Air may be trapped in fuel line. Check fuel lines for leaks. 3. Try to operate engine manually. Please accept our sincere apology if any modification in performance, specification or appearance is made without prior notice. EG3000 7