As ept i c I s olator s

Similar documents
PHARMACY Products. Compounding Aseptic Containment Isolator (CACI) A level of safety that is built in, not bolted on. Underwriter Laboratories Listed

PHARMACY Products. Compounding Aseptic Isolator (CAI) Positive pressure sterility assurance barrier isolator for complete product protection.

A viewscreen top hinge allows full opening for loading of instrumentation or equipment.

SterilSHIELD. Designed for Aseptic Compounding of Non-Hazardous Pharmaceuticals. SterilSHIELD Barrier Isolator (positive pressure)

BioPROtect III. and BioPROtect III Jr. Class II Style Walk-In Clean Air and Containment Enclosures.

PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR

SterilGARD. Meets NSF Standards. Underwriter Laboratories Listed

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

VERSAFLOW SERIES UNIDIRECTIONAL LAMINAR AIRFLOW COMPOUNDING ASEPTIC ISOLATOR (CAI)

BioChemGARD. Meets NSF Standards. Underwriter Laboratories Listed

PHARMAGARD 797 CREATING A SINGLE SOURCE SOLUTION TO ENSURE THE ACCURACY AND STERILITY OF COMPOUNDED PHARMACY PRODUCTS

NU-430/435 CLASS II, TYPE B2 BIOLOGICAL SAFETY CABINETS

GloveFAST Cyto Pharma GloveFAST Cyto Aseptic Isolators PROTECTION, SAFETY, RELIABILITY AND MORE.

GloveFAST Cyto/Aseptic. Isolators PROTECTION, SAFETY, RELIABILITY. AND MORE.

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

SterilGARD III Advance Sets the Industry s Highest Standard for Comfort, Performance and Safety.

The better choice for an optimum balance of energy efficiency with performance. Class II, Type A2 Biological Safety Cabinet, Vertical Flow

Best Products. Best Performance. Best Protection.

PCR Laminar Flow Cabinets

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Thermo Scientific 1300 Series A2. Class II, Type A2 Biological Safety Cabinets. Good for you good for the environment

High Performance Ductless Balance Enclosures

Hospital Pharmacy Isolator (Positive Pressure) The Premium Solution for Sterile Drug Compounding. Esco Hospital Pharmacy Isolator, Model HPI-4P_.

PRECISE. Glove Boxes

USP 800: Quick Summary

Hospital Pharmacy Isolator (Negative Pressure, Recirculating) The Premium Solution for Sterile Drug Compounding

Hospital Pharmacy Isolator (Negative Pressure, Recirculating) The Premium Solution for Sterile Drug Compounding

Biological Safety Cabinet

LABGARD FEATURES

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

BSC-1100IIA2-X is designed to meet the operating principles:

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Compounding Aseptic Containment Isolators (Recirculating and Total Exhaust) The Premium Solution for Sterile Hazardous Drug Compounding

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

convenience. containment. comfort. Thermo Scientific Class II, Type A2 Biological Safety Cabinets

Protector Glove Boxes.

AS , EN12469 (Microbiological Testing Method)

Protector Controlled Atmosphere Glove Boxes

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

USP 800: Now What Do We Have To Do?!

Compounding Aseptic Containment Isolator (Recirculating) The Premium Solution for Sterile Drug Compounding

<800> Hazardous Drugs Handling in Healthcare Settings. Jeanne Sun, PharmD

6/18/2015. USP <800> Update. USP <800> - What is it? What are HDs? John Voliva, R.Ph. Director of Legislative Relations PCCA

CG2010 Cytogard Cytotoxic Drug Safety Cabinets

Ventilated Balance Enclosures

LAMINAR FLOW HORIZONTAL FLOW BENCH (LF) OPERATION & MAINTENANCE MANUAL

High protection against allergens and contaminants Spacious working area High cleanability and visibility Microprocessor controls and safety alarms

SafeFAST Elite. Class II Microbiological Safety Cabinets PROTECTION, SAFETY, RELIABILITY. AND MORE.

LAMINAR AIRFLOW EQUIPMENT

OmniAire 2200C Operations and Maintenance Manual

Polypropylene Total Exhaust Fume Hoods

Compounding Safety Solutions.

GETZ EQUIPMENT INNOVATORS SYSTEM DUST 120V ECONOMY PART NUMBER: 4G59542 OPERATING AND INSTRUCTION MANUAL

Envirco BIOLOGICAL SAFETY CABINET

Precise Glove Boxes & XPert Weigh Boxes

Ductless Nanoparticle Containment Enclosures

Class II biological safety cabinets

Safety, Installation and Service Manual Models 1952, 1953 & 1972

Envair Lab SCS Evo Comfort+ Class II Microbiological Safety Cabinets

Controlled Environment Equipment Solutions for the Lab

LFBC - LATERAL FLOW BIO CONTAINMENT FOR HPAPI PROCESSING FLOW SCIENCES, INC.

Safe Handling of Hazardous Drugs in the Pharmacy and

CDC F RANGE NEGATIVE PRESSURE ISOLATORS

Contamination Control Laboratories (CCL) Pty Ltd

MODEL 950C-NP-UV Installation and Owners Manual

NOTE: The color of the actual product may differ from the color pictured in this catalog due to printing limitation.

Ductless Nanoparticle Containment Enclosures

Smart design has its rewards. NEW! Thermo Scientific MSC-Advantage Class II Biological Safety Cabinet. Part of Thermo Fisher Scientific

A Thermolab Group Company. HyZone. Class II Microbiological Safety Cabinets. for operator, environment and product protection.

Advanced PCO System. Installation Instructions & Consumer Information. Section I. Important Installer Information WARNINGS

Class II Biological Safety Cabinets The World's Most Energy Efficient, Quiet, and Compact Biosafety Cabinet

Series EuroFlow Biological Safety Cabinets Class II

Pharmagard Negative Pressure Total Exhaust Sterile Isolator. Models NU-NTE /600 Bench/Console. Operation & Maintenance Manual

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Techlab - Matériaux de Référence certifiés et Equipements de Laboratoire -

Turbine Submersible Pumps

PRYCO, INC. P. O. BOX 108 Mechanicsburg, IL OPERATIONS AND MAINTENANCE MANUAL For PUMP SETS

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

September 2012 / M&H C502 / Model 129

(Class II Type A2 & B2)

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Dual Phase Extraction Inlet. Patent No Installation Manual. P/N Rev

Cytotoxic Safety Cabinet The Premium Solution for Cytotoxic Drug Processing. Esco Cytoculture Cytotoxic Safety Cabinet Model CYT-4A_

CLASS II BIOSAFETY CABINET

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

Blue Air. Commercial Refrigeration Inc. Installation & Operation Manual Glass Door Countertop Refrigerator

Reach ins, Freeezers & Refrigerators Installation & Operation Manual

Revolutionizing Clean Environments Containment. Comfort. Convenience

Healthcare Solutions Room Pressure Monitors and Controls

Mega-Flow External Damper Fans

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

Further information: Berriman Associates Model 850P.2 Owners Manual

21", 33", 45", & 61" Installation & Operation Manual

Low Profile Service Jack Jack Stand Combo

AVK SERIES 41 SWING CHECK VALVE FIELD MAINTENANCE AND INSTRUCTION MANUAL FOR SWING CHECK VALVES 3" - 12"

OPERATOR S MANUAL. Class II, Type A2 Biological Safety Cabinet MODELS:

Class I Microbiological Safety Cabinets The Leading Energy Efficient, Quiet, and Ergonomic Biosafety Cabinet

Transcription:

As ept i c I s olator s Underwriter Laboratories Listed

Compounding Aseptic Isolators A level of safety that is built in, not bolted on, to provide both personnel and product protection Offers a contained, pressurized work area for pharmacy applications One of the most comfortable isolators in the industry, with oval gloveports that offer easy reach to interior surfaces, and adjustible height stand Slanted, top-hinged viewscreen allows for full opening for loading and unloading of pharmacy instrumentation or equipment HEPA-filtered, unidirectional airflow with better than ISO Class 5 (Class 100) air cleanliness conditions to prevent contaminants from entering the work area Combines industry-leading airflow technologies with exceptional design and ergonomic features to improve worker comfort and increase productivity

ChemoSHIELD and SterilSHIELD Designed for aseptic pharmaceutical compounding Industry-Leading Airflow Technology Provides Superior Sterility Ergonomic Features Maximize User Comfort and Ease of Use Construction and Craftsmanship of the Highest Standard Plenum Design Optimizes Protection and Extends Filter Life Microprocessor-Based Control Board Simplifies Operation* A viewscreen top hinge allows full opening for loading of instrumentation or equipment. StediVOLT Motor Speed Controller Maintains Precise Airflow* Utilities Designed for Convenience, Practicality, and Safety A viewscreen top hinge allows full opening for loading instruments or equipment. The viewscreen is locked to prevent unauthorized opening. *Not available on ChemoSHIELD PAGE 1

ChemoSHIELD A Compounding Aseptic Containment Isolator (CACI) designed for the containment of hazardous chemotherapy and other agents and IV admixtures ChemoSHIELD negative pressure compounding aseptic containment isolators offer a contained, leak-tight (tested to AGS standard), negative pressure work area suitable for hazardous pharmaceutical compounds, chemotherapy agents or IV admixtures that can be harmful to pharmacy personnel. ChemoSHIELD creates a unidirectional HEPA-filtered airflow of better than ISO Class 5 (Class 100) air cleanliness conditions within the negative pressure chamber to prevent migration of hazardous contaminants to the outside and to minimize cross-contamination across the direct compounding area. ChemoSHIELD has no onboard motor/blower to maintain and service. All static pressure and airflow is supplied by the building exhaust system. Uncompromised Safety and Performance The industry-leading design features of ChemoSHIELD allow it to provide sterile interior conditions while also increasing personnel protection from exposure. A spacious, negative pressure pass-through chamber allows safe and easy transfer of materials into or out of the main chamber. Supplied gloves and glove sleeves are ASTM D6978 tested for use with chemotherapy drugs. A hinged viewscreen allows for easy loading of instruments and equipment. Ambidextrous gloves are positioned in the main chamber to allow total access to the interior. The pass-through door also includes one ambidextrous glove to permit manipulation of contents or surface decontamination of items moved to or from the main chamber. HEPA-Filtered Interlock Permits Secure Pass-Through In and Out of the Work Area Pass-through door to the main work area swings open for easy transfer of materials between the interchange and main chamber. The clear-view outer interlock door is left-hand swinging. The door seals against peripheral gaskets to maintain internal negative pressure. This door opens only when inner chamber door is closed. The pass-through door to the main work area swings open while under negative pressure. This door opens only when the outer door is closed. PAGE 2

Cabinet Containment, Personnel and Product Protection The isolator pass-through and main chamber pressure are negative to the room. In the standard configuration, the pass-through is slightly more negative than the main chamber to prioritize cleanliness in the main chamber while ensuring containment of hazardous compounds throughout the isolator. The pass-through door and inner chamber door are mechanically interlocked to prevent both doors from being opened simultaneously. Individual supply and exhaust HEPA filters service the main chamber and interchange. Exhaust filters are safely and easily removed via bag-out provision to contain hazardous compounds prior to disposal. A stainless steel air diffuser in the main chamber and pass-through offers additional protection to supply filters. Key lock on cabinet front prevents unauthorized opening of fully-hinged front viewscreen that may compromise containment capability or aseptic environment. Mass airflow monitor audio/visual alarm system warns the user when the exhaust system has inadequate airflow. Optimized Interior Work Space, Plus Simplified Cleaning All interior surfaces of the main chamber and pass-through are made of durable stainless steel for superior corrosion resistance. Back and side walls are polished to a non-glare, easy-to-clean finish. Interior surfaces can be accessed via glove ports for sanitization. The interior cabinet s radius corners permit easy wipe down. The sectional work surface trays are fully removable. Trays stack easily to either side to simplify cleaning and filter changes. Exterior, scratch-resistant, powder coat finish provides the durability required in pharmacy environments. The isolator pass-through and main chamber pressure are always negative to the room, providing superior containment. Pharmacy Resource Center Over a decade ago, the United States Pharmacopeia issued Chapter 797 "Pharmaceutical Compounding Sterile Preparations" (USP <797>), which provides the guidelines, procedures and compliance requirements for compounding sterile preparations and sets the standards that apply to all settings in which sterile preparations are compounded. With the addition of USP <800> "Hazardous Drugs Handling in Healthcare Settings," our resource center has been prepared to help you stay current on the latest issues about aseptic preparation of hazardous and non-hazardous drug products. Scan the QR code to learn more or click here. PAGE 3

SterilSHIELD A Compounding Aseptic Isolator (CAI) designed for aseptic compounding of non-hazardous pharmaceuticals SterilSHIELD positive pressure compounding aseptic isolators (CAIs) offer a contained, positive pressure work area suitable for non-hazardous pharmaceutical compounding. SterilSHIELD creates a unidirectional HEPA-filtered airflow of better than ISO Class 5 (Class 100) air cleanliness conditions within a positive pressure chamber to provide superior sterility and to minimize cross-contamination. Pressure Balance Ensures Product Protection The isolator main chamber pressure is positive to the room, ensuring no room contaminants can enter the work area. Additionally, the main chamber is slightly more positive than the pass-through to maintain aseptic conditions in the main chamber. Full-ceiling, front-loading HEPA supply filter is 99.99% efficient; provides better than ISO Class 5 (Class 100) air within the pass-through and main working chambers. Unidirectional downward airflow purges airborne particulates from the work area. Stainless steel air diffuser in the main chamber and passthrough provides unidirectional airflow and protects the HEPA filter. The Isolator main chamber pressure is positive to the room. The main chamber is slightly more positive than the pass-through interchange to ensure aseptic conditions within the main chamber. PAGE 4

Plenum Design Optimizes Protection and Extends Filter Life SterilSHIELD employs a unique, high performance airflow system that provides optimum protection from particulates, extends filter life and reduces cost of ownership. The filter configuration creates internal unidirectional airflow from top to bottom that sweeps particulates from work area. The filter cross section covers 100% of the work area. The unique plenum apportions and distributes air across, then through the HEPA supply filter, improving downflow uniformity, extending useful filter life and reducing noise. The filter mount provides a direct seal of the filter to the plenum and simplifies filter replacement. HEPA-Filtered Pass-Through In and Out of the Work Area The outer pass-through door is constructed of clear-view shatterproof acrylic plastic and opens with a left-hand swing. (SterilSHIELD 800 has doors on both ends; the left door swings left and the right door swings right.) A convenient lift-up sash opens to 8" to permit quick transfer of small items without opening the door. The outer door seals against peripheral gaskets to maintain internal positive pressure. The internal pass-through door lifts vertically for maximum use of space and permits easy transfer of materials in or out of the positive pressure work area. *NOTE: SterilSHIELD is not intended for use with biologically hazardous materials. Baker Aeseptic Isolators Performance Summary Pressure Sterility Containment Environmental Protection Downflow Exhaust ChemoSHIELD Negative to room Yes Yes Protects from particulates. Protects from vapors/gases if connected to a treated exhaust system. HEPA HEPA-filter to facility exhaust SterilSHIELD Positive to room Yes No No Vented to room PAGE 5

Technical Specifications ChemoSHIELD Summary Specification MODEL NUMBER CS500 CS600 Size 5' [1.5 m] 6' [1.8 m] Electrical Service Requirements 115V AC, 15A, 60Hz, 1 PH 115V AC, 15A, 60Hz, 1 PH 220V, 16A, 50/60Hz, 1 PH 220V, 16A, 50/60Hz, 1 PH Interior Dimensions (Pass-Through) 17 1/2" W x 24" D x 25" 3/8 H 17 1/2" W x 24" D x 25" 3/8 H [445 x 610 x 644 mm] [445 x 610 x 644 mm] Interior Dimensions (Main Chamber) 31" W x 24" D x 25" 3/8 H 46" W x 24" D x 25" 3/8 H [787 x 610 x 644 mm] [1168 x 610 x 644 mm] Exterior Dimensions, Nominal 60" W x 35 3/4" D 75" W x 35 3/4" D [1524 x 908 mm] [1905 x 908 mm] Net Weight 570 lbs [259 kg] 650 lbs [295 kg] Ship Weight 660 lbs [299 kg] 815 lbs [370 kg] Options and Accessories Many options, accessories and modifications are available and should be specified when ordering. Commonly requested options are listed below. For detailed information on accessories and modifications, contact us. Ergonomically adjustable footrest (field installed) Seismic restraints (field installed) IV bar ULPA filters Floor and wall anchors Hydraulic lift stand Airtight damper Black iron plumbing (voids UL) Replacement gloves/sleeves that meet ASTM D 6978 PAGE 6

Technical Specifications SterilSHIELD Summary Specification MODEL NUMBER SS400 SS500 Size 4' 5' Electrical Service Requirements 115V, AC and 220V, AC 115V, AC and 220V, AC Amps (Total) 20 / 16 20 / 16 Interior Dimensions (Pass-Through) 14 1/2" W x 21 1/8" D x 26 1 2" H 18 1/2" W x 20 5 8" D x 26 1 2" H [368 x 537 x 673 mm] [470 x 537 x 673 mm] Interior Dimensions (Main Chamber) 31 3/8" W x 21 1/8" D x 26 1/2" H 39 3/8" W x 20 5/8" D x 26" 1/2 H [797 x 537 x 673 mm] [1000 x 524 x 673 mm] Exterior Dimensions, Nominal 53 3 4" W x 33 1/4" D x 59 11/16" H 65 3 4"W x 33 1/4" D x 59 11/16" H [1365 x 845 x 1516 mm] [1670 x 845 x 1516 mm] Net Weight (includes stand) 650 lbs [295 kg] 698 lbs [ 317 kg] MODEL NUMBER SS600 SS800* Size 6' 8' Electrical 115V, AC 115V, AC Amps (Total) 20 / 16 2x20, 2x16 Interior Dimensions (Pass-Through) 18 1/2" W x 20 5 8" D x 26 1 2" H 14 1/2" W x 21 1 8" D x 26 1/2" H (x2) [470 x 537 x 673 mm] [368 x 537 x 673 mm] Interior Dimensions (Main Chamber) 51 3 8"W x 20 5/8" D x 261 2"H 31 3/8" W x 20 5/8" D x 26" 1/2 H (x2) [1305 x 524 x 673 mm] [797 x 537 x 673 mm] Exterior Dimensions, Nominal 773 4"W x 33 1/4" D x 59 11/16" H 1091 2"W x 33 1/4" D x 59 11/16" H [1975 x 845 x 1516 mm] [2781 x 845 x 1516 mm] Net Weight 772 lbs [350 kg] 1444 lbs [655 kg] *SS800 is comprised of two SS400 models with a tunnel, is shipped in two pieces, and is assembled on site. Options and Accessories As with ChemoSHIELD, many options, accessories and modifications are available and should be specified when ordering. Commonly requested options are listed below. For detailed information on accessories and modifications, contact us. Waste / sharps chute Duplex outlet, ground fault circuit interrupter (GFCI), 115V, AC, with weatherproof cover (main working chamber); duplex outlets are standard on SS800 Single petcock located right wall, center (option for 2 on right-hand side) Ergonomically adjustable footrest (field installed) Floor and wall anchors IV bar ULPA filters Hydraulic ergonomic lift stand Stainless steel work trays to help organize work and facilitate ingress/egress Under drain pan bins Replacement gloves/liners/sleeves PAGE 7

NIOSH Alert NIOSH calls for cabinets used to prepare chemotherapy drugs to be exhausted to the outdoors because of the risk of vaporization of hazardous drugs. ChemoSHIELD is designed to comply with the NIOSH alert and requires connection to an externally vented exhaust system. Warranty The Baker Company, Inc., expressly represents and warrants all goods (a) to be as specified (and described) in The Baker Company catalogs and literature, and (b) to be free under normal use, service and testing (all as described in The Baker Company catalogs and literature) from defects in material and workmanship for a period of thirty-six months from the invoice date on units sold in the United States and twelve months for units sold internationally. The exclusive remedy for any breach or violation of this warranty is as follows: The Baker Company, Inc., will F.O.B. Sanford, Maine, furnish without charge repairs to or replacement of the parts or equipment that proved defective in material or workmanship. No claim may be made for any incidental or consequential damages. THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE UNLESS OTHERWISE AGREED IN WRITING SIGNED BY THE BAKER COMPANY. (THE BAKER COMPANY SHALL NOT BE RESPONSIBLE FOR ANY IMPROPER USE, INSTALLATION, SERVICE OR TESTING OF THE GOODS.) CS-SS-070116 P.O. Drawer E, Sanford, ME 04073 (207) 324-8773 (800) 992-2537 Fax: (207) 324-3869 bakerco.com 2016 The Baker Company. All rights reserved.