MCW Application Notes 24 th August 2017

Similar documents
TRIPS AND FAULT FINDING

Grundfos MP1 Manual.

AC drive has detected too high a Check loading

RVS-DN Digital Reduced Voltage Motor Starter

APPLICATION NOTE AN-ODP March 2009

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

690+ Series Integrator

Overvoltage Suppression F7 Drive Software Technical Manual

HIB Enclosed Inverter User Guide

RVS-DX Digital Reduced Voltage Motor Starter

USERS MANUAL MCD REMOTE OPERATOR

GS2 Series - Introduction

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Parker AC10 Frequency Inverter (to 22kW) Easy Start Guide

RVS-AX Instruction Manual

Presentation Soft starters 0 Altistart 48 soft start - soft stop units

1333 (SERIES B & C) TROUBLESHOOTING GUIDE

SD700FR. Regenerative Active Front End VARIABLE SPEED DRIVES POWER ELECTRONICS / SD700 SERIES 4 QUADRANT. icool

VLT Soft Starter MCD 100, MCD 201, MCD 202, MCD 3000

Unidrive M400 Fast set-up and diagnostics with real-text display, integrated PLC and safety inputs

Number 1 in efficiency

Unidrive M700 Class leading performance with onboard real-time Ethernet

List of Tables: Page # Table 1: Emerson Commander SK VFD parameter settings 2. Table 2: Allen Bradly Power Flex 4M VFD parameter settings 3

Product Brochure. The motor speed control experts. AC motor speed control products and peripherals for the motion and automation control industries


Varispeed E7. Varispeed E7. Varispeed. Varispeed E7. Varispeed E7. Varispeed E7 INVERTER SERIES

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

HPS2DB Serial Softstarter Operation Manual

Unidrive M600 High performance drive for induction and sensorless permanent magnet motors

VLT Soft Starter. Remote operation. Serial communication 24 V AC/DC V AC. Constant effort to improve MCD 100, MCD 201, MCD 202, MCD 3000

Softstarters. Softstarters Type SSM Medium voltage ,800V 1

ARM V FDBK ENSURE MOTOR IS NOT ROTATING DURING POWER UP STILL FAULTS? YES ENSURE ARMATURE WIRING IS ISOLATED FROM ANY OTHER POWER LEADS STILL FAULTS?

Kelly HSR Series Motor Controller with Regen User s Manual V 3.3. Kelly HSR Opto-Isolated Series Motor Controller with Regen.

SMS PRODUCT CATALOGUE

Shenzhen Sine Electric Co., Ltd.

Kelly KDHA High Voltage Series/PM Motor Controller User s Manual

RS232 Communications cable with PC ER M. RJ-45 / USB Adapter Remote Operator Extansion Cable. Communication Unit. Mounting Accesories

Drive Electronics \ Drive Automation \ System integration \ Services MOVITRAC LTP. Catalog. Edition 03/ / EN

BBC-3140 USER MANUAL DC-DC CHARGER / BATTERY EQUALIZER / VOLTAGE REDUCER

Stock Drives Catalogue. Variable Speed Drives & Accessories

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

The smd frequency inverter Compact, powerful, without compromise simply smart

High performance Vector Control. Ratings. System configuration

Regenerative DC Common Bus Supply

ABB Softstarter Benefits Charnchanok Thongprad

MAKING MODERN LIVING POSSIBLE. Design Guide VLT MCD 100 Soft Starter the single speed drive

EDB6032_G/GB Antriebstechnik. Operating Instructions. Brake chopper 6032/6033/6034

Number 1 in efficiency

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

LG Air conditioning CAC and Multi Split unit Fault code sheet Universal and Multi Split Units

Design Guide. VLT Soft Start Controller MCD 100

Open Chassis Star-Delta Starter User Guide

CTi Automation - Phone: Fax: Web:

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

8 Troubleshooting and Maintenance

1332 TROUBLESHOOTING GUIDE. Remarks: If this function is not appropriate for the application, it can be eliminated by turning off DSWl, switch 3.

TDBU Series Dynamic brake unit user manual

J1000 D E F I 1000 J1000 J1000 J1000 J1000

AuCom - Soft Starters

Honeywell CORE Drive FEATURES APPLICATION SPECIFICATION DATA

SDS Enclosed Star-Delta Starter User Guide

MULTI LANGUAGE KEYPAD

PowerOhm Installation Manual for LG ATV Series Braking Modules

ATOTH-G Series BLDC Motor Controller. User s Manual

Stock Drives Catalogue. Variable Speed Drives & Accessories

HIGH PERFORMANCE VECTOR CONTROL DRIVE

MSC VAC. Variable Speed Drive. Proudly 100% Australian Owned Australian Manufacturers & Distributors of Variable Speed Drives & Soft Starters

9.1.4 Troubleshooting of Faults in LCD Screen

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Experience & Innovation

User s Manual: SMARTSTART Series. Models: 6R15 6R830 6V400 6V630

1/2 thru 1.5 Hp 1/2 thru 3 Hp 2 thru 5 Hp 1 thru 10 Hp

Application example of a motor controlled by MCD100 and protected by a circuit breaker

SSW07. Soft Starters. Applications. Standard Features

Section 8. MAINTENANCE & TROUBLESHOOTING

Kelly KDC Series/PM Motor Controller User s Manual

Devices Supported: KEB48220 KEB48221 KEB48300 KEB48301 KEB48400 KEB48401 KEB48600 KEB48601 KEB72330 EB KEB72450 KEB EB KEB72600 KEB

sinamics SINAMICS G110 Variable Speed Drives 0.12 kw to 3 kw SINAMICS G110 Short Form 2004

Table of Contents. 2 Installation and Start-up Instructions for AF-600 Bypass, NON Bypass & Disconnect Drive Panels - DEH40600

5.1 Errors (Alarms) Error (alarm) definitions PROTECTIVE FUNCTIONS. (1) Major faults

1B filter, RFI 1 B/LC filter. VLT 2800 Motorcoil, RFI

L300P Inverter Specifications

A problem with the motor windings. A phase loss on mains terminals L1, L2, or L3 during run mode. Parameter 2-3 Current Imbalance Delay.

Symbol Input rating Symbol 2 Three-phase, 200 ~ 230V N 4 Three-phase, 380 ~ 480V. None. Loader. Graphic. Loader

IP 20/NEMA 1 & IP 66/NEMA 4X Compact Vector Control Drive

V1000. Inverter Series.

V1000 Inverter Series

Delta Products VFD CP2000 Bypass Control Packages.

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

A. Provide variable frequency drives to operate variable torque loads as shown on the Drawings and as specified herein.

Frequency Inverters SJ Series Type P1

Description 1/8-7.5HP

Quick Reference Guide. For NFX9000 Adjustable Frequency Drives. February 2006 NQ00. MN E February 2006

Variable speed drives Altivar 78. Catalogue May

BR Second Position Voltages. AA Fourth Position

Hitachi America, Ltd.

SMD10 SMD11 SMD15 SMD30

SINUS PENTA 2T/4T SINUS PENTA 2T/4T

A. Danfoss VLT Soft Starter The single speed drive. For any soft start situation MAKING MODERN LIVING POSSIBLE

Transcription:

MCW Application Notes 24 th August 2017 www.motorcontrolwarehouse.co.uk Document number MCW-E3-051 Revision 0.0 Author Gareth Lloyd Product Optidrive E3 Title Summary Optidrive E3 Fault Finding This document gives information on fault finding on Optidrive E3 Note: Please read in conjunction with the Optidrive E3 User Guide Overview The Optidrive E3 has various trip codes which are shown on the display to indicate a fault. This document lists all of the trip codes and also gives possible causes and corrective actions. This document also gives details on the display and what it will show depending on the set up and the status of the drive. Motor Control Warehouse Page 1

Optidrive E3 Trip Codes O1-B - Instantaneous over current on dynamic brake output (+BR) OL-BR - Braking resistor overload O-1 - Instantaneous over current on drive output 1.T-TRP- Accumulated overload trip 0-Uo1T- Over voltage on DC bus U-Uo1T- Under voltage on DC bus O-T- Heat-sink over-temperature U-T - Drive under temperature P-DEF - Factory default parameters loaded (Press the Stop/Reset button) E-TRiP - External trip S(-OBS - Optibus serial communications loss trip FLT-Dc - DC bus ripple too high P-LO55 - Input phase loss trip ho-1 - Fast over-current trip on drive output Th-FLT - Faulty thermistor on heat-sink data~f - Internal memory fault (IO PCB processor) 4-20%F - 4-20mA analogue input signal loss data~e - Internal memory fault (Power PCB processor) F-PTc - Motor PTC thermistor trip Fan~F- Internal cooling fan fault (IP66 units only) O-hEaT - Drive internal temperature too high ATF-O1 to ATF-OS - Autotune fault S(-FO1 - Modbus serial communications fault S(-FO2 - CANOpen serial communications fault OVT-F - Drive output fault, output stage trip FAULTY - Internal drive communication issue between control and power processors Motor Control Warehouse Page 2

Fault Finding Fault Code Possible cause and corrective actions O-1 Drive software instantaneous over current trip. Usually caused by accelerating or decelerating the motor/load too quickly or by shock loads on the motor/load. Check motor star/delta connection correct for drive output voltage. Check motor not seized and motor brake is releasing (if used). Make sure motor brake is not connected to drives output. Incorrect drive set up. Check motor nameplate parameters P-07, P-08 & P-09 are correct for the motor. Check torque boost setting in P-11 and reduce if necessary. If an autotune has been carried out and then the motor and/or motor cable has been changed, re-autotune the drive to the motor. Check correct setting of Motor Control Mode P-51. If multi-motor application or motor choke fitted, make sure P-51 = 1 (V/f mode). Check connections between inverter output and motor for loose connections etc. Disconnect motor to check that drive runs without motor connected. ho-1 Drive hardware instantaneous over current trip. Usually caused by a phase to phase or phase to earth fault on the drive output. Check motor cable and motor for faults. Disconnect motor to check that drive runs without motor connected. Make sure motor brake is not connected to drives output. Check connections between inverter output and motor for loose connections etc. See information for O-1 trip. OVT-F Drive output fault. Usually indicates that one output phase is missing or motor phase currents are not balanced. Check drive output connections, motor cable, motor connections and motor. Disconnect motor to check that drive runs OK without motor connected. 1.T-TRP Motor thermal overload trip. The drive has tripped after delivering >100% of the value in P-08 for a period of time to prevent damage to the motor. Load to large for motor/drive rating. Check actual motor current and compare to setting of P-08. Check motor star/delta connection correct for drive output voltage. Check motor not seized and motor brake releasing (if used). Incorrect drive set up. Check motor nameplate parameters P-07, P-08 & P-09 are correct for the motor. (Check P-09 is correct if high frequency/speed motor) Increase acceleration and deceleration ramps in P-03 and P-04. Check torque boost setting in P-11 and reduce if necessary. If an autotune has been carried out and then the motor and/or motor cable has been changed, re-autotune the drive to the motor. Check correct setting of Motor Control Mode P-51. Check setting of P-54 Current limit. If multi-motor application or motor choke fitted, make sure P-51 = 1 (V/f mode). NOTE: The O-I and ho-i trips cannot be reset for at least 4s after a trip occurs. Motor Control Warehouse Page 3

0-Uo1T Over voltage on drives DC bus. Check mains supply voltage is within tolerance. If trip occurs during deceleration, increase deceleration ramp time in P-04. Install a suitably rated braking resistor to dissipate regenerated energy. Makes sure braking resistor function is enabled in P-34. U-Uo1T Under voltage on drives DC bus. An under voltage trip will occur normally when the mains power supply is removed from the drive. Check the mains supply voltage is within tolerance. Check all components in the mains power supply to the drive. FLT-Dc Voltage ripple on drive DC bus above allowable level (See P00.06) Check that all mains supply phases are preset and balanced. Check all components in the mains power supply to the drive. P-LO55 Mains supply input phase loss. Only measured on input phase L1. Check that all mains supply phases are preset and balanced. Check all components in the mains power supply to the drive. O-T Heatsink over temperature (See P00.09 <95 o C). Check drive cooling fan is working and that the fan/heatsink air path isn t blocked. Check ambient air temperature around drive. Ensure sufficient cooling and ventilation in enclosure. U-T Heatsink under temperature (See P00.09 <-10 o C). Occurs when heatsink temperature is <-10 o C. Heatsink temperature must be raised above -10 o C in order to run the drive. E-TRiP External trip requested on digital input 3 (terminal 4). Normally open contact between 24V and terminal 4 has opened for some reason. Check correct setting of parameter P-15. If motor thermistor is connected to terminal 4 (check setting of P-47) check motor is not too hot. Th-FLT Faulty heatsink thermistor. 4-20%F 4-20mA signal lost (<3mA)(See P-16 and P-47). When current (ma) analogue input signal is used on terminals 4 or 6 and P-16 or P-47 is set to a ma trip mode, signal has fallen below 3mA. Check control cabling. Check analogue input signal (See P00.01 and P00.02) F-PTc Motor PTC thermistor trip (See P-15 and P-47). Excessive motor temperature. Check thermistor wiring. Check motor wiring (drive is correctly connected in star/delta) O-hEaT Drive internal ambient temperature too high (See P00.20). Check ambient air temperature around drive. Ensure sufficient cooling and ventilation in enclosure. P-DEF Factory default parameters loaded. Initiated by pressing the UP, DOWN & STOP keys for >2s. Press the STOP key and this will reset thep-def trip. Motor Control Warehouse Page 4

O1-B OL-BR FAN-F S(-OBS S(-FO1 S(-FO2 data~f data~e ATF-O1 to ATF-OS FAULTY Brake channel over current. Brake resistor too small an ohmic value or short circuit. Check that the braking resistor value is greater than the recommended minimum value. Check brake resistor condition and cabling. Brake resistor overload (See P-34). The drive will trip on OL-BR if P-34 = 1 or 3 and the 200W Invertek brake resistor has been overloaded. Increase the deceleration ramp in P-04. The resistor power rating is too small for the regenerated energy. Increase resistor power rating and set P-34 = 2 or 4. Internal cooling fan fault (IP66 units only). There is an internal cooling fan on the IP66 units. This fan is monitored to make sure that it is rotating. If the fan stops rotating, the drive will trip on FAN-F. Optibus serial communications loss. Check the communications link between the drives RJ45 connector and external devices. Make sure each drive has its own unique serial comms address (See P-36) Modbus RTU serial communications loss. Check the Modbus RTU cable connections. Check that at least one register is being polled cyclically within the timeout limit set in P-36 index 3. CANopen serial communications loss. Check the CANopen cable connections. Check that cyclic communications takes place within the timeout limit set in P-36 index 3. Internal memory fault (Control PCB processor). Try setting default parameters. Internal memory fault (Power PCB processor). Try setting default parameters. Autotune fault (See P-52). The motor parameters measured during an autotune are incorrect. Check the motor cable and connection between the drive and motor. Check the motor cable for continuity between drive and motor. Check all 3 motor phases are present and balanced. Drive communications fault between control and power microprocessors Power cycle the drive to see if this clears the fault. Motor Control Warehouse Page 5

Other possible issues and solutions Motor runs at low speed when high speed requested When drive is powered up with a connection between control terminals 1 & 2, drive remains in SToP Not enough starting torque for application Has a RPM value been set in P-10 which changes the frequency parameters to RPM and then a low RPM value been set in P-01 Maximum speed. The drive is in current limit which will hold the drives output frequency at a low value. Check actual output current compared to 1.1 X P-08 (fan/pump) or 1.5 X P-08 (industrial). See 1.T-TRP trip information above. Check value of P-30. As default, P-30 is set to edge~r so the drive is expecting a signal transition between 0V and 24V to allow it to run. If a hardwire connection is between control terminals 1 & 2, the drive will not run. Either open and close the connection between terminals 1 & 2 or change P-30 to AUTo-0. With P-30 at AUTo-0, the drive will enable and run as soon as power is applied to it. See Knowledge Base document MCW-E3-044 Increase P-11 Torque boost voltage in small increments. NOTE: The default value of P-11 is suitable for starting the majority of loads and therefore does not need adjusting. Parameter P-11 (low speed torque boost) should be increased with caution and only in small increments. Increasing P-11 will increase the voltage applied to the motor at low speed to help increase motor starting torque. On heavy starting torque loads: Too low a value of P-11 can cause the motor to stall due to lack of starting torque. Too high a value of P-11 can cause the motor to stall because it is over fluxed. If P-11 is set to a very high value, this can cause the drive to trip on O-I or ho-i (over current). The drive does not react to signals on the analogue or digital inputs The drive trips on 0-Uo1T (over voltage) on a fan/high inertia load applications See Knowledge Base document MCW-E3-037 Analogue inputs Check P00.01 (AI 1 terminal 6) and P00.02 (AI 2 Terminal 4). These should go from 0 to 100% = 0 to 10V/4-20mA etc. Digital inputs Check P00.04 (Digits should change from 0 to 1 when digital inputs are connected to 24V. Set P-10 (motor rated speed) to 0 RPM. If it is required to see RPM on the display, set P-10 to the synchronous speed of the motor (3000, 1500, 1000, 750 RPM) Increase acceleration or deceleration times on P-03 & P-04 A braking resistor maybe required if trying to stop a high inertia quickly. Motor Control Warehouse Page 6

Display indications Display shows STOP to indicate that no enable/run signal has been applied to the drive. Display shows output frequency in Hz Display shows output current in Amps Display shows output power in kw Display shows output speed in RPM Display shows customer defined units. See parameter P-40 Drive is in overload. Motor current is greater than current value set in parameter P-08 Fire mode is active. See parameters P-15 = 15, 16, 17 & 18 Motor Control Warehouse Page 7

Mains loss is active. The voltage applied to L1 input phase is low or has been lost. When mains loss is active, the drive will remain in STOP mode. Drive is in Standby mode. See parameter P-48. Motor Control Warehouse Page 8