ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

Similar documents
magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

EFFEKTA Power Supplies

D Series: UPS UPTO - 300KVA - Three / Three Phase

TECHNICAL DATA SHEET KVA UPS Systemss

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

MKN-DSP SERIES - THREE PHASE

True double-conversion online single-phase UPS. PowerValue 11 RT 1 10 kva Single-phase UPS for critical applications

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

Onfiniti. 1 Phase UPS

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

UPS SYSTEMS PDUs SURGE PROTECTORS POWER INVERTERS DATACENTER UPS. Product Catalog

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

On-line, Single Phase, Double Conversion UPS

Industrial PFC UPS System

Liebert NX TM. 250kVA kVA Transformer-free. High Efficiency, Scalable On-line UPS

PowerWave 33 Efficient power protection for today s IT and process-related work environments

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

PowerScale TECHNICAL SPECIFICATIONS

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Three-phase UPS system. DPA UPScale ST kw Best-in-class modular UPS for maximum availability

Technical data sheets

Liebert GXT-MT 1-3kVA UPS. Power Protection for Business Critical Continuity

Aurora Single Phase Emergency Lighting Inverters

PowerScale kva Technical Specifications

Standard 1000VA, 2000VA & 3000VA Universal Tower/Rack Mount LB Extended Models 900VA, 1700VA & 2500VA

Series 120/120VAC Universal Tower/Rack Mount

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

POWER kva

POWER kva

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

W Datasheet: UPS AVARA Modular kVA (1-8 x 15kvA)

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

YOUR POWER IN SAFE HANDS. E Series UPS

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

MGE TM Galaxy TM 7000 GFC

PowerValue 11/31 T kva

Master DIALOG INDUSTRY RANGE

» Sophisticated» Reliable» Intelligent

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Liebert. FP 50Z kva

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Est FlexiPower Mini UPS FPX Mini kVA

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Technical Data Sheets

POWER NEVER ENDS UPS SOLAR INVERTER STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY

MGE TM Galaxy TM 7000

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Three Phase UPS Systems Range: 10 to 500kVA

Features and Benefits

Technical Data Sheets

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheets

POWER UPS SOLAR INVERTER NEVER ENDS STANDBY UPS LINE INTERACTIVE UPS ONLINE UPS OFF-GRID INVERTER ON-GRID INVERTER WITH ENERGY STORAGE ACCESSORY

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TLE Series UPS 750/1000 kw With eboost Technology

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TLE Series UPS 400/500 kw With eboost Technology

Off-Grid Solutions (Solar Controller & Invertor)

Technical data sheets

TLE Series UPS 160/200/225/250 kw with eboost Technology

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

PRODUCT CATALOG (IEC) Low-power UPS. Low-power UPS

MGE Galaxy 5500 Marine

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

ConceptpowerTM Modular kVA

UPS Multi Power 1-28 x 42 kw up to 1MW

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

un I Jet ИБП ABB Conceptpower DPA 500 ( квт) - технические спецификации. Юниджет

DPA 250 S4 (50 kw 1,500 kw) The most energy-lean UPS on the market MODULAR THREE-PHASE UPS SYSTEMS. The most energy-lean UPS on the market

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

SmartOnline 120V 2.2kVA 1.8kW Double-Conversion UPS, 2U, Extended Run, Network Card Slot, LCD, USB, DB9

Standalone three-phase UPS system. PowerWave kw Unmatched power performance

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

Modular UPS «AGIL» Stay on! Changing the rules for critical business continuity :

Technical Data Sheets

Green Power 2.0 MASTERYS GP

Huawei Network Energy, Powering the Future. Huawei UPS Solutions HUAWEI TECHNOLOGIES CO., LTD.

Application. Battery. Public Grid GS HYBRID INVERTER

Technical Data Sheets

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

Phase Modular Finally the benefits of Modular ups are for all

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Three Phase UPS Systems

Transcription:

ELEKTRA SERIES I.T GRADE ONLINE DOUBLE CONVERSION UPS 10KVA ~ 500KVA (3/3) Mission Critical & I.T Grade UPS

Elektra Series (3/3, H.F) (10KVA~500KVA) Elektra Series I.T Grade On Line Double Conversion UPS represents the best solution that is both effective and environment friendly, it delivers and excellent integrated autonomy, reduced footprint and optimum input and output performances, guaranteeing reliable and flexible power. Elektra Double conversion pure on-line three phase input and output UPS adopt double conversion technology, able to provide solutions to conditions like voltage instantaneous drop-off or damping concussion, high-voltage plus, voltage pulsation, surge voltage, harmonic distortion, and frequency fluctuation, guarantees a safe and reliable power. UPS status can be monitored at a glance on an intuitive LCD screen. Elektra Series offer redundant and capacity parallel Ups, the right solution for all applications requiring a perfect and uninterrupted power supply. This is a green product that comply with the products pollution control management measures, the product under normal use, will not harm the environment and personals using it.

Active Input Correction (Pfc) With digital control of active power factor correction technology, enables high input power factor 0.99 above as to avoid contamination of electrical network environment, saving energy and reducing system costs. Compatible With Generators Input voltage and frequency range is wide so it can effectively works on generator and thus provide pure, safe and stable power. 0.9 ~ 1 The 0.9 & 1 Output reaffirms your original Deutsche Power Elektra Series purchase by fully leveraging your existing UPS investment to accommodate today s and tomorrow s high power factor load requirements. High-efficient, Energy Saving, Green Environmental Protection The efficiency of the machine is as high as 94% and reaches over 98% in the ECO mode which can help to reduce the power loss of the UPS s IGBT, FM, intelligent rectifier and inverter technology, input power factor 0.99, & input current harmonic wave (THDi) is as low as 3%. Excellent Overload Capacity When higher protection required, the optional dust-proof accessories can help to increase the protection level in harsh environment and safeguard the UPS s security. Elektra series UPS provide a broader range of input voltage from 210VAC to 475VAC, which ensures to be applicable in the unpleasant grid environment of different power supply equipment like generator, with its extraordinary input frequency. Zero Switching Transfer time when UPS transferred to the battery or vice versa is zero, effectively guarantee the load operation security and reliability. Application Elektra range provide a combination of outstanding protection features and flexibility, making it the right choice for applications demanding optimum reliability and energy efficiency. Systems such as servers, networking devices, workstations, storage systems and various IT equipment find the right protection element in Elektra Series, especially, when combined with Elektra Powerful Connectivity suite. VolP equipment, railway control systems, medical laboratory instrumentation, and many other industrial applications may also benefit from the consistent and high quality power provided by the Elektra, thanks to the robustness, precision and high efficiency provided. Key Features Advance IGBT Rectifier technology, input power factor: 0/99 Powerful Extensibility Features Smart slot provides rich scalable features, USB can be selected, AS400 card, SNMP card, RS485 card and environmental monitoring card. Standards Input THDi <3% The efficiency of the machines is as high as 94%. Connect parallel for maximum flexiblity and compatible to battery share in the parallel mode, which helps the customers to extend the system capacity with low cost. Intelligent management of battery charging and discharging. Lightning and surge protection, short circuit and overload protection. Safety: IEC/EN62040-1, IEC/EN60950-1. EMC IEC/ EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 Noise Suppression Complies with EN62040~2

MODEL RANGE INPUT Principal of working Phase Bypass OUTPUT / Regulation Crest Factor Efficiency BATTERY Charge Current (A) (It can be set according to battery capacity installed) Battery SYSTEM FEATURES Transfer time Overload: Line Mode Bat. Mode LCD Display Communication Interface ENVOIRMENTAL Oprating Temperature Stroage Temperature Humidity Range Altitude Noice Level PHYSICAL Dimension D x W x H (mm) Net Weight (kg) STANDRADS Safety Noise Suppression TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT ESH1033 10KVA/9KW ESH1533 15KVA/13.5KW ESH 2033 20KVA/18KW ESH3033 30KVA/27KW ESH4033 40KVA//36KW ESH6033 60KVA/54KW ESH8033 80KVA/72KW True On-line, Double Conversion, Static Bypass Switch Three phase + N + PE 208~478V >0.99 40/70Hz 2% (100% non-linear load) Max.Volt.: 220V+25%(optional + 10%,+15%,+20%) 230V 20% (optional +10%, +15%) 240V 15% (optional +10%) Minimum volt.: -45% (optional -20%, _30%) Protection Range: ± 10% 380/400/415V (Adjustable), Three Phase + N + PE, ±2% 0.9 1.Line Mode: ±1% / ±2%/ ± 4%/ ± 5%/ ± 10% of the rated frequency (optional) 2.Battery Mode: (50/60±0.2%)Hz 3:1 <2% with linear load <5% with non linear load 94.5% Standrad unit: ± 216Vdc; Long run unit Optional: ± 192V\ ± 240V\ ± 216V\± 228V\ ± 240V 5.7A (Max./standard unit) 6.0A (Max./Long run unit) Advance Battery Management 12A 18A Utility to battery: 0ms; Utility to bypass:0ms Load<110%:last 60min, <125%: Last 10min, < 150%: Last 5min,>150% shutdown UPS Immediately Load<110%:last 10min, <125%: Last 1min, < 150%: Last 5S,>150% shutdown UPS Immediately Input &, Output & Load Percentage, Battery & inner Temp. RS232, RS485,Parallel,Intelligent slot,relay Card (Optional, SNMP) Card (optional) S:591 H;123 S:594 H;126 S:595 H;127 0 ~ 40C -25~55C 0~95% (non condensing) <1500m <55db 780 x 600 x 1200 S:595 H;127 158 158 195 Safety: IEC/EN62040-1, IEC/EN60950-1. EMC IEC/ EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4-4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 Complies with EN62040~2 DP Electronics e.k(deutsche Power Co. Limited) has a policy of continuous product development and improvement and therefore reserve the right to vary any information without prior notes.

MODEL RANGE INPUT Principal of working Phase Bypass OUTPUT / Regulation Crest Factor Efficiency BATTERY Charge Current (A) (It can be set according to battery capacity installed) Battery SYSTEM FEATURES Transfer time Overload: Line Mode Bat. Mode LCD Display Communication Interface ENVOIRMENTAL Oprating Temperature Stroage Temperature Humidity Range Altitude Noice Level PHYSICAL Dimension D x W x H (mm) Net Weight (kg) STANDRADS Safety Noise Suppression TECHNICAL SPECIFICATION FOR THREE PHASE IN & THREE PHASE OUT ESH10033 100KVA 90KW/100KW ESH12033 ESH16033 ESH20033 ESH30033 ESH40033 ESH50033 120KVA 160KVA 200KVA 300KVA 400KVA 500KVA 108KW/120KW 144KW/160KW 180KW/200KW 270KW/300KW 360KW/400KW 450KW/500KW True On-line, Double Conversion, Static Bypass Switch Three phase + N + PE 208~478V >0.99~1 40/70Hz 2% (100% non-linear load) Max.: 220V+25%(optional + 10%,+15%,+20%) 230V 20% (optional +10%, +15%) 240V 15% (optional +10%) Minimum voltage: -45% (optional -20%, _30%) Protection Range: ± 10% 24A 380/400/415V (Adjustable), Three Phase + N + PE, ±1% 0.9/1(Customized) 1.Line Mode: ±1% / ±2%/ ± 4%/ ± 5%/ ± 10% of the rated frequency (optional) 2.Battery Mode: (50/60±0.2%)Hz 3:1 <2% with linear load <5% with non linear load 94.5% / 96% Customized Standrad unit: ± 216Vdc; Long run unit Optional: ± 192V\ ± 240V\ ± 216V\± 228V\ ± 240V 24A 36A 50A 80A Advance Battery Management Utility to battery: 0ms; Utility to bypass:0ms Load<110%:last 60min, <125%: Last 10min, < 150%: Last 5min,>150% shutdown UPS Immediately Load<110%:last 10min, <125%: Last 1min, < 150%: Last 5S,>150% shutdown UPS Immediately Input &, Output & Load Percentage, Battery & inner Temp. RS232, RS485,Parallel,Intelligent slot,relay Card (Optional, SNMP) Card (optional) 70db 0 ~ 40C -25~55C 0~95% (non condensing) <1500m 100A 73db 130A 780 x 600 x 1200 800x600x1600 850x600x1600 850 x 1200 x 2000 286 288 348 380 600 815 860 Safety: IEC/EN62040-1, IEC/EN60950-1. EMC IEC/ EN62040-2, IEC61000-4-2, IEC61000-4-3, IEC61000-4- 4, IEC61000-4-5, IEC61000-4-6, IEC61000-4-8 Complies with EN62040~2 DP Electronics e.k(deutsche Power Co. Limited) has a policy of continuous product development and improvement and therefore reserve the right to vary any information without prior notes.

DP ELECTRONICS (DEUTSCHE POWER CO., LIMITED) Germany Head Office DP electronics e.k (Deutsche Power Co., Limited) Klon, Germany. Phone: +49-221-26016266 Fax: +49-221-26016267 Email: enquiries@deutschepower.de Hong Kong Office RM 1701(057), 17/F, HeNan Building No90, Wan Chai, Hong Kong. Phone: +86-755-82610239 Fax: +86-755-82610233 helenlong@deutschepower.de