Flow Characteristics of Air in Square Channel Using Perforated Ribs

Similar documents
Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Experimental Investigation on Turbulent Flow Heat Transfer in a Horizontal Circular Pipe using Coil and Twisted Tape Inserts

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

Pressure Drop Distribution in Smooth and Rib Roughened Square Channel with Sharp 180 Bend in the Presence of Guide Vanes

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

Experimental Analysis of Heat Transfer and Friction Factor Characteristics in Turbulent Flow through a Tube Fitted with Screw Tape

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

Experimental Study of Heat Transfer Enhancement in Tube in Tube Heat Exchanger using Rectangular Wing Type Vortex Generator

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

ADVANCES in NATURAL and APPLIED SCIENCES

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

Optimization of Fluid Coupling performance for Hybrid Power Transmission System

International Journal of Advance Engineering and Research Development

Design and experimental analysis of pipe in pipe heat exchanger

DESIGN AND ANALYSIS OF UNDERTRAY DIFFUSER FOR A FORMULA STYLE RACECAR

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

Thermal Stress Analysis of Diesel Engine Piston

Impacts of Short Tube Orifice Flow and Geometrical Parameters on Flow Discharge Coefficient Characteristics

Heat transfer enhancement of a single row of tube

CFD ANALYSIS OF PRESSURE DROP CHARACTERISTICS OF BUTTERFLY AND DUAL PLATE CHECK VALVE

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

Comparison of Velocity Vector Components in a Di Diesel Engine: Analysis through Cfd Simulation

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

Forced Convection Heat Transfer Analysis through Dimpled Surfaces with Different Arrangements

Heat Transfer Enhancement In Pipe With Passive Enhancement Technique

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

Study of Inlet Guide Vanes for Centrifugal Compressor in Miniature Gas-Turbines

Heat Transfer Augmentation Technique Using Twisted Tape Insert

Flow Behavior and Friction Factor. in Internally Grooved Pipe Wall

HEAT TRANSFER ENHANCEMENT IN A CIRCULAR TUBE FOR TURBULENT FLOW OF WATER USING PERFORATED RECTANGULAR STRIPE INSERT

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Vibration Measurement and Noise Control in Planetary Gear Train

PERFORMANCE ANALYSIS ON DOUBLE PIPE HEAT EXCHANGER USING WIRE COILED AND PIN WIRE COILED TURBULATOR INSERTS

CFD analysis of triple concentric tube heat exchanger

SWIRL MEASURING EQUIPMENT FOR DIRECT INJECTION DIESEL ENGINE

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

Numerical Investigation of Convective Heat Transfer and Pressure Loss in a Round tube Fitted with Circular-Ring Turbulators

CFD ANALYSIS ON LOUVERED FIN

Thermal Analysis of Laptop Battery Using Composite Material

Effect of Helix Parameter Modification on Flow Characteristics of CIDI Diesel Engine Helical Intake Port

An Experimental Investigation for the Rate of Heat Transfer in Double Pipe Heat Exchanger with Fins on Inside Surface of Internal Tube

FLOW CONTROL THROUGH VORTEX SHEDDING INTERACTION OF ONE CYLINDER DOWNSTREAM OF ANOTHER. Jonathan Payton 1, and *Sam M Dakka 2

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

Performance Evaluation Of A Helical Baffle Heat Exchanger

Exhaust Gas Waste Heat Recovery and Utilization System in IC Engine

CFD Analysis for Designing Fluid Passages of High Pressure Reciprocating Pump

Redesign of exhaust protection cover for high air flow levelling valve

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR AND NANOFLUID

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

TEMPERATURE APPROACH OPTIMIZATION IN THE DOUBLE PIPE HEAT EXCHANGER WITH GROOVE

Analysis of External Aerodynamics of Sedan and Hatch Back Car Models Having Same Frontal Area by Experimental Wind Tunnel Method

CRITICAL ASSESSMENT OF LITERATURE IN THE FIELD OF ENHANCED HEAT TRANSFER TECHNIQUES

Experimental Study on Heat Enhancement of Helixchanger with Grooved Tubes

Research Article Thermohydraulic Analysis of Shell-and-Tube Heat Exchanger with Segmental Baffles

Experimental Investigation on Forced Convection Heat Transfer Augmentation Using Annular Blockages

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

A Study on Performance Enhancement of Heat Exchanger in Thermoelectric Generator using CFD

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

Back pressure analysis of an engine muffler using cfd and experimental validation

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

Study on Flow Fields in Variable Area Nozzles for Radial Turbines

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

ECH 4224L Unit Operations Lab I Fluid Flow FLUID FLOW. Introduction. General Description

Generation of Air Swirl through Inlet Poppet Valve Modification and To Enhance Performance on Diesel Engine

Chapter 7: Thermal Study of Transmission Gearbox

A Study on the Optimum Shape of Automobile Air Cleaner Diffuser

AUGMENTATION OF TURBULENT FLOW HEAT TRANSFER IN A HORIZONTAL TUBE WITH VARYING WIDTH TWISTED TAPE INSERTS

Familiarize yourself with the pressure loss phenomenon. The Discussion of this exercise covers the following point:

ANALYSIS OF SURFACE CONTACT STRESS FOR A SPUR GEAR OF MATERIAL STEEL 15NI2CR1MO28

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

ENHANCEMENT OF HEAT TRANSFER RATE AND REDUCTION OF SHELL SIDE PRESSURE DROP IN HELIX HEAT EXCHANGER WITH CONTINUOUS HELICAL BAFFLES

Manufacturing Elements affecting the Performance & Durability Characteristics of Catalytic Converter

Analysis of Parametric Studies on the Impact of Piston Velocity Profile On the Performance of a Single Cylinder Diesel Engine

Heat Exchangers (Chapter 5)

Numerical and Experimental Investigations of Heat Transfer in Double Pipe Heat Exchangers with Inner and Annular Twisted Tape

THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER

Load Analysis and Multi Body Dynamics Analysis of Connecting Rod in Single Cylinder 4 Stroke Engine

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

Aerodynamically induced power loss in hard disk drives

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

International Journal of Scientific & Engineering Research, Volume 5, Issue 3, March ISSN

Experimental Analysis on Minor Head Loss for Flow through Locally Manufactured Ball Valve for Supplying Fluid in Bangladesh

Transcription:

IOSR Journal of Mechanical and Civil Engineering (IOSR-JMCE) e-issn: 2278-1684,p-ISSN: 2320-334X, Volume 13, Issue 1 Ver. II (Jan. - Feb. 2016), PP 106-112 www.iosrjournals.org Flow Characteristics of Air in Square Channel Using Perforated Ribs Abhishek.R.H 1, Anand kumar S Malipatil 2 1 (Department of Thermal Power Engineering, VTU,RO/PG Kalaburagi, India) 2 (Department of Thermal Power Engineering, VTU,RO/PG Kalaburagi, India) Abstract: The present experiment is conducted to study and analyse the effect of perforated ribs vortex generator having the aspect ratio (A.R) of 2, 3 and 5 on friction factor ratio of air flow through a square channel having the aspect ratio (A.R) of 1.0.The friction factor ratio and pressure drop characteristics in a square channel with different geometrical configurations of perforated ribs vortex generators are studied. Geometrical configurations in a square channel are symmetrically varied at different pitch to height ratio and at different aspect ratio of vortex generator. Perforated ribs vortex generators are inserted in a square channel. The experiment is repeated for different configurations of perforated ribs vortex generators and the results are reported for aspect ratio (A.R) of vortex generator 2,3,5 and pitch to height ratio (p/h) of 4, 8, 12, 16 for the corresponding Reynolds number (Re) ranges from 8000 to 24000. Keywords: Square channel, perforated ribs, pressure drop, vortex generator, Aspect ratio, smooth duct, Friction factor ratio. I. Introduction The process of improving the performance of heat transfer system is referred to as heat transfer enhancement. There are varieties of heat exchanger devices that are used to carry out these applications. Heat exchanger techniques are used in process industries, refrigerators, automobile radiators, air conditioning equipments, thermal power plants etc. Performance improvement in terms of improvement of heat transfer rate and reduction in the pressure drop becomes essential in such applications. In many such applications of heat exchanger, gas turbines and electronic equipment convective heat transfer plays a very important role. Many methods are available to increase heat transfer rate. Vortex generators are often used to increase thermal performance by manipulating flow field. This project presents experimental results of flow analysis of air inside a square channel. Square channels are mainly preferred to cool turbine blades effectively and also to achieve more compactness. There are large number of methods available to increase the heat transfer coefficient which may be classified as, 1.Active method: It requires external power such as twisted tapes, rough surfaces, extended surfaces, helical screw tape inserts, mechanical devices or surface vibration. 2. Passive method: This method does not require electric power such as electric or acoustic fields, mechanical devices or surface vibration instead it make use of special surface geometry. It is inexpensive compared to the other methods. In this method the inserts are placed in the direction of flow passage in order to increase heat transfer rate. It is more beneficial than active method since manufacturing of inserts is very simple and can be used in heat exchanger. 3. Compound method: Enhancement that uses more than one method is referred as compound method. This method includes both active and passive techniques to obtain heat transfer enhancement. The heat transfer enhancement by this method is greater than the heat enhancement produced by active method and passive method. Here we are discussing about passive methods and are based on two stages one is by disturbing thermal boundary layer and the other one is by using bulk fluid mixing. The process of destruction as well as restarting of the boundary layer in the presence of roughness elements causes increase in heat transfer rate by producing a boundary layer which is thinner on an average than that of uninterrupted boundary layer. Vorticity in the flow can increase the heat transfer through bulk fluid mixing which reduces temperature gradients concentrating thermal gradient in the near wall region II. Experimental Set-Up The schematic representation of the experimental set up of Flow analysis of air in a square channel using perforated ribs is as shown in the figure given below, DOI: 10.9790/1684-1312106112 www.iosrjournals.org 106 Page

Fig 1. Experimental set-up It consists of a square channel of size 900*30*30mm length, breadth and height of the square channel respectively. Two pressure taps are provided for the measurement of pressure across the test section. Variable speed blower having power of 6600watts is used. No load speed of the blower is 0-1600rpm.Air volume ratio is 3.5m 3 /min and the weight of the blower is around 1.7kg.An U-tube manometer is used for the measuring differential pressure head across venturimeter. Differential manometer with a combination of water and benzyl alcohol (sp.gravity=1.046) as manometer fluids is connected to two pressure taps to measure the pressure drop across test section. A gate valve is used to regulate the air flow rate. Perforated ribs are glued on bottom surface of square channel with strong adhesives for roughening the channel. III. Methodology In this, the blower sucks the air. The air enters into the test section which is made up of acrylic sheet. The rate of air flow is controlled by using gate valve. Using venturimeter and U tube manometer, the air flow rate in the test section can be measured. When air flows in the test section, there is friction between the air and square channel surfaces. Thus pressure drop takes place. This pressure drop is measured by noting down the values of differential head of the benzyl alcohol in the micro differential manometer. By noting down the pressure drop values we can calculate the friction taking place in the duct. Then the perforated ribs are placed in main direction of flow passage in the test section. As air flows in the test section, the air collides with the vortex generators as a result of which pressure drop takes place which can be measured by micromanometer. Perforated ribs are used as vortex generators. This procedure is repeated to obtain friction factor values for different configurations of the perforated ribs glued on the bottom surface of square channel for different Reynolds number, different aspect ratio and different pitch. IV. Geometry And Computational Details Axial pitch (p): The axial distance between the adjacent vortex generators is the axial pitch of the vortex generator configuration. Vortex generator height (h): The distance between the perforated rib vortex generator top and bottom surface of the square channel upon which it is glued is the vortex generator height. Vortex generator base (b): The base width dimension of the perforated rib vortex generator at which it is glued to the bottom surface is the vortex generator base. Pitch to height ratio(p/h): It is ratio of the axial distance between two identical points of the adjacent vortex generators to the vortex generator height. Aspect ratio (AR):The measure of the shape and size is known as aspect ratio of the vortex generator. The aspect ratio for perforated ribs vortex generator is given as AR=W/h. Friction factor ratio(f/fs): The ratio of frictional factor of the rough duct to the frictional factor of smooth duct where, f-friction factor of square channel with vortex generator and fs-friction factor of square channel without vortex generator or smooth duct. Reynolds number(re): It is defined as the ratio of inertia force to viscous force., Re=ρνDh/µ Where v is velocity of air in duct, Dh hydraulic diameter, ρ - air density,µ - dynamic viscosity of air. DOI: 10.9790/1684-1312106112 www.iosrjournals.org 107 Page

V. Data Reduction Mass Flow Rate: m= ρq ρ= air density Reynolds Number: Re= ρvd h /µ µ=absolute viscosity of air v=average velocity of air through the duct Pressure Drop: It is calculated by measuring pressure at the two pressure taps provided in test section which are connected to differential manometer. The equation is, p x p y 1 a a 2hg 2[1 (1 ) ] A A 2 Friction Factor Ratio(f/fs): The friction factor ratio is determined in terms of pressure drop across test section, f/fs p [(4L/ h)( v 2 / 2)] 2 Smooth Duct Friction Factor (ff) : It is calculated by using the Blasius equation. Friction factor for fully developed turbulent flow, ff=0.046(re) -0.2 VI. Results And Discussion Fig 2 shows the graph obtained from plotting friction factor (ff) versus Reynolds number (Re) for a smooth square channel. Where fa is the actual friction factor obtained from the experiment and ft is the theoretical friction factor obtained from the Blasius correlation. From the graph, actual friction factor fa agree well within range of ±7% and ±4% of the theoretical frictional factor ft obtained from Blasius correlation Fig 2.Result obtained from smooth Duct Effect of Reynolds number (p/e) on Friction Factor Ratio (f/fs) Figure 3 to 5 shows the effect of Reynolds number (p/e) on Friction Factor Ratio (f/fs).it can be observed from graph that friction factor ratio increases as Reynolds number increases. The rate of vortex generation depends on the flow velocity in the square channel and the velocity of the fluid flow inside the square channel is directly proportional to Reynolds number. With increasing velocity, pressure drop increases automatically friction factor ratio increases. In fig 3,the friction factor ratio at Reynolds number 24000 is 35.52% greater than the friction factor ratio at Reynolds number 8000. Due to perforations laminar boundary layer gets disturbed as a consequence of which high turbulence is produced. Friction factor in perforated ribs is more than solid ribs due to turbulence and resistance against flow. DOI: 10.9790/1684-1312106112 www.iosrjournals.org 108 Page

Fig 3.Variation of f/fs with Re (AR=5, h=6mm, Perforated ribs with 2mm dia. holes) Fig 4. Variation of f/fs with Re (AR=3, h=10mm, Perforated ribs with 2mm dia. holes) Fig 5. Variation of f/fs with Re (AR=2, h=15mm, Perforated ribs with 2mm dia. holes) Effect of Pitch to Height Ratio (p/e) on Friction Factor Ratio (f/fs) Figures 6 to 8 shows the effect of pitch to height ratio on friction factor ratio (f/fs) for different Reynolds number with ribs having aspect ratios AR=2,3 and 5.The axial distance between the two perforated ribs vortex generators plays an important role here. If the axial pitch of the perforated rib is small than the flow gets disturbed by the next perforated rib vortex generator resulting into high pressure drop. If the distance between the two adjacent perforated ribs vortex generator is high then pressure drop decreases and as a result of which friction factor ratio also decreases. Here the number of holes is 3 and all the 3 holes are of 2mm diameter. In fig 6 we can observe that friction factor ratio increases upto (p/h)=8 and then it gradually decreases upto (p/h)=12 and then again it starts (p/h)=16.this fluctuation is mainly due to the breakdown of vortices in the test section.if the axial pitch is small then flow gets disturbed by next perforated rib vortex generator resulting in breakdown of vortices.for the rest of the flow pattern is nearly the same.the flow collides the ribs and enters the perforations and leaves the ribs from the other side. DOI: 10.9790/1684-1312106112 www.iosrjournals.org 109 Page

Fig 6. Variation of f/fs v/s p/h (AR=5, h=6mm, Perforated ribs with 2mm dia. holes) Fig 7. Variation of f/fs v/s p/h (AR=3, h=10mm, Perforated ribs with 2mm dia. holes) Fig 8. Variation of f/fs with p/h (AR=2, h=15mm, Perforated ribs with 2mm dia. holes) Effect of Vortex Generator Aspect Ratio (ar) on Friction Factor Ratio (f/fs) Figures 9 to 12 shows the variation of friction factor ratio with change in aspect ratio of perforated ribs vortex generator for different Reynolds numbers. Friction factor ratio increases with aspect ratio upto optimum value of p/h ratio. The size of the vortex generator plays an important role in generating vortices. When aspect ratio is less the height of vortex generator is high, hence vortices generated overlaps one over the other due to lesser axial pitch and hence laminar boundary layer gets disturbed because of which high turbulence is produced which causes blockage of air as a result of which pressure drop increases and hence friction factor ratio (f/fs) also increases. If aspect ratio increases then height of vortex generator decreases thus the size of the vortex generator decreases hence blockage of the flow is very less compared to the vortex generator having lower aspect ratio. Therefore friction factor ratio decreases dramatically as height decreases due to less deflection and less bulk flow blockage. This can be noticed from graph friction factor ratio at aspect ratio 3 to aspect ratio 5. From the above graph, friction factor ratio increases upto aspect ratio 3 and then it decreases steeply upto the aspect ratio value of 5.Friction factor ratio (f/fs) at aspect ratio 5 is 33.34% lower than that of the (f/fs) value at aspect ratio of 2 for corresponding (p/h) value of 16 at the Reynolds number of 8000. DOI: 10.9790/1684-1312106112 www.iosrjournals.org 110 Page

Fig 9.Variation of f/fs with AR (p=4mm, Perforated ribs with 2mm dia. holes) Fig 10: Variation of f/fs with AR (p=8mm, Perforated ribs with 2mm dia. holes) Fig 11. Variation of f/fs with AR (p = 12mm, Perforated ribs with 2mm dia. holes) Fig 12. Variation of f/fs with AR (p=16mm, Perforated ribs with 2mm dia. holes) VII. Conclusions 1.The friction factor ratio decreases with increase in Reynolds number in case of smooth channel but from the graphs it is observed that square duct having perforated ribs vortex generators the friction factor ratio increases as Reynolds number increases because in these ducts better mixing of air takes place and the vortex generator blocks maximum amount of air in ducts at higher Reynolds number. For Aspect Ratio =5,h=6mm :The friction factor ratio at Reynolds number 24000 is 35.52% greater than the friction factor ratio at Reynolds number 8000. DOI: 10.9790/1684-1312106112 www.iosrjournals.org 111 Page

2. It is observed from the results that for a flow in square channel that friction factor ratio decreases with increase in pitch to height ratio.ar=5, h=15mm:friction factor ratio at (p/h) = 16 is 45.61% lower than that of the friction factor ratio (f/fs) at (p/h) = 4. 3. For Aspect Ratio =5 and h=6mm friction factor ratio increases upto (p/h)=8 and then it gradually decreases upto (p/h)=12 and then again it starts increasing upto (p/h)=16. This fluctuation is mainly due to the breakdown of vortices in the test section. 4.From the graph friction factor v/s aspect ratio friction factor ratio increases upto aspect ratio 3 and then it decreases steeply upto the aspect ratio value of 5. 5.For 4 holes the highest value of friction factor ratio is at p/h=8 and it is of value 12.52 and for 8 holes the highest value of friction factor ratio is at p/h=8 and it is of value 24.86. VIII. Nomenclature A = Area (m 2 ) A 1 = Area at inlet (m 2 ) A 2 = Area at throat (m 2 ) Q = Flow rate of air (m 3 /s) Cd = Co-efficient of discharge g = Acceleration due gravity (m/s 2 ) h = Height of perforated rib L = Channel length (mm) p = Pitch to height ratio Re = Reynolds number t = thickness (mm) V = Velocity (m/s) = Kinematic viscosity W = Channel width (mm) ρ = Density (Kg/m 3 ) ff = Friction factor ratio between channels. α = Angle of attack AR = Aspect ratio f/fs = Friction factor ratio P = Pressure References [1]. R.Tauscher, F.Mayinger Enhancement of heat transfer in a plate heat exchanger by Turbulence premotors Journal of Heat Transfer Enhancement of Heat Exchangers 1999,Pages 207-221. [2]. Ting Maa, Qiu-wang, WangMin Zeng, Yi-tung Chen, Yang Liu, Vijaisr Nagarajan Study on heat transfer and pressure drop performances of ribbed channel in the High temperature heat exchanger ELSEVIER Publication Applied Energy 99 (2012) 393 401. [3]. Giovanni Tanda, Heat transfer in rectangular channels with transverse andv-shaped broken ribs, International Journal of Heat and Mass Transfer 47 (2004) 229 243. [4]. S. Liu, M. Sakr, A comprehensive review on passive heat transfer enhancements in pipe exchangers, Renewable and Sustainable Energy Reviews 19 (2013) 64 81. [5]. Soo Whan Ahn and Kang PH Son, An Investigation on Friction Factors and Heat Transfer Coefficients in a Rectangular Duct with Surface Roughness, KSME International Journal, VoL 16 No.4, pp. 549-556, 2002. [6]. Monsak Pimsarn, Parkpoom Sriromreun, and Pongjet Promvonge, Augmented Heat Transfer in Rectangular Duct with Angled Z- Shaped Ribs PEA-AIT International Conference on Energy and Sustainable Development: Issues and Strategies (ESD 2010) The Empress Hotel, Chiang Mai, Thailand. 2-4 June 2010. 249 [7]. Caliskan, S. (2013). Flow and heat transfer characteristics of transverse perforated ribs under impingement jets, International Journal of Heat and Mass Transfer 66 (pp.244-260). DOI: 10.9790/1684-1312106112 www.iosrjournals.org 112 Page