DuraMACTM Booster Pumps

Similar documents
Installation Instructions Light Commercial & Irrigation Water Pressure Booster System

DuraMAC LIGHT COMMERCIAL & IRRIGATION WATER PRESSURE BOOSTER SYSTEM INSTALLATION INSTRUCTIONS

24000 Series. High Flow 4 Stainless Steel GPM 6/13

+\YH4(*;4 >H[LY 7YLZZ\YL )VVZ[LY :`Z[LT 0UZ[HSSH[PVU 0UZ[Y\J[PVUZ +\YH4(*

Pressure Master. SubDrive MonoDrive E-Z Pac 3/15

Jet Pumps. Convertible Shallow Well. 6/13 Rev (3/14)

Curb Stops. Regular & Minneapolis Pattern 12/12

MODEL 500S10HP86 B13 MODEL 300S10HP66 B13. 6 & 8 Pump Ends GPM Stainless Steel Pumps 6/13

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER SYSTEM

TW W-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

TW G-40 FLAG FRAME VARIABLE SPEED BOOSTER PUMP SYSTEM

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM

INLINE 1100 COMPACT, MULTI-PUMP SYSTEM. franklinwater.com

TW1000E-20W-70-DCA In Enclosure w/ Double Check Assembly VARIABLE SPEED BOOSTER SYSTEM

Duplex Commercial Pressurizer -DCP

Commercial Pressure Booster Systems

INLINE 1100 STAGED PALLET SYSTEM. franklinwater.com

BoosterpaQ Hydro MPC-ED Guide Specification

BoosterpaQ Hydro MPC-EF Guide Specification

VSPS PACKAGE BOOSTER SYSTEM (END SUCTION PUMP DESIGN) FEATURES T Y P E

21000 Series. 4 No-Lead Brass Submersible Pumps 5/15

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

Aquavar e-abii. TECHNICAL BROCHURE BAQUAeABII VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Wilo CO-Helix Pressure Boosting Systems. Engineering Specification

ITT. Goulds Pumps. 5GB, 7GB, 10GB, 18GB, 25GB, 33GB High Pressure Multi-Stage Booster Pump. Engineered for life. Residential Water Systems FEATURES

VERTICAL MULTI-STAGE PUMPS

5GB, 7GB, 10GB, 18GB, 25GB, 33GB

VERTICAL MULTI-STAGE PUMPS

Webtrol s Family of Pumps

GRUNDFOS PRODUCT GUIDE. Hydro Solo-E. Grundfos Hydro Solo-E booster sets 60 Hz

ITT. Goulds Pumps. AquaForce PRESSURE BOOSTING SIZING GUIDE. Engineered for life. Building and Municipal Applications.

VERTICAL MULTISTAGE PUMP SETS

Mizer Single Pump and Starter Box

DPS. The SSV Dual Pump System

AquaBoost Packaged Systems

RSV Series In-Line Vertical Multi-Stage, Ring Section Pump September 2013

SUBMITTAL DATA WATER PRESSURE BOOSTER SYSTEMS

1000 Series Neptune Booster Systems. Flows to: 20,000+ GPM Heads to: 700+ PSI Temperatures to: 250 F

Aquavar ABII TECHNICAL BROCHURE BAQUABII R2 VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

Variable Speed Product Line

Installation & Operating Manual

TECHNICAL BROCHURE B5-33GB R4 5GB, 7GB, 10GB, 18GB, 25GB, 33GB HIGH PRESSURE MULTI-STAGE BOOSTER PUMP

EZ SERIES BOOSTER PUMPS

CURTIS TOLEDO. AF Series Compressors VS models with VFD WARNING

Series. NV Vertical Multistage Booster Pump

GROUNDWATER PRODUCTS

Iron Gate Air Pump System Manual

General Catalog. A New Vision for Quality Pumps. General Catalog

D51 D61 D71 D91 Series

TECHNICAL BROCHURE BSPDDRIVE. Aquavar SPD (Single Pump Drive) SIMPLEX VARIABLE SPEED PUMP CONTROLLER FOR SUBMERSIBLE AND CENTRIFUGAL PUMPS

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS

TECHNICAL BROCHURE BSPMSPH R1 SOLD SEPARATELY OR BUILT IN. PrimeLine SP SPM & SPH SERIES

EZ SERIES BOOSTER PUMPS

EZ SERIES BOOSTER PUMPS

Design Envelope Booster Systems. Design Envelope Booster Systems. FILE NO: DATE: Feb. 05, 2010 SUPERSEDES: DATE: Jan.

RSV In-Line Vertical Multi-Stage, Ring Section Pumps

SECTION DOMESTIC-WATER PACKAGED BOOSTER PUMPS

EVMU. Model EVMU / EVMUG / EVMUL Contents. EBARA Stainless Steel Vertical Multistage

DETAILED EQUIPMENT SPECIFICATION MR SERIES WATER SOFTENERS

CONSTANT PRESSURE CONTROLLERS

HIGH CAPACITY CENTRIFUGAL & SPRINKLER PUMPS

MICROPUMP MAG-DRIVE GEAR PUMPS

EN. 850 Filtrate Pumps. Technical Specification Pages

GRUNDFOS PRODUCT GUIDE DMH. Dosing pumps

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

W4100, W4200 & W4300 Electric Pump

SUBMERSIBLE PUMPING SYSTEMS SUBMERSIBLE TURBINE PUMPS

High Capacity Centrifugal & Sprinkler Pumps

S P R AY E R VA L V E S AND C O N T ROL S C AT A L OG

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

Iron Gate Feed Pump Manual

245 W. Roosevelt Road Building 12, Suite 83 West Chicago, IL

TECHNICAL BROCHURE B36/3742 R2 3642/3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

STOP CITY PRESSURE BOOSTER PUMP INSTRUCTION MANUAL

Hydropak Booster Systems. Series motralec

DETAILED EQUIPMENT SPECIFICATION MHC SERIES WATER SOFTENERS

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

Intelligent Pump Drive

LEAD FREE * LFF113RFP Flood Protection Shut Down Valve

BOOSTER PUMPS PRODUCT FAMILY APPLICATIONS FAMILY COMPARISON CHART

franklinwater.eu 50 HZ EH - EHsp SERIES HORIZONTAL MULTISTAGE AND SELF-PRIMING PUMPS

T Series Pump Guide WEBSTER PUMPS

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

GLYCOL FEED SYSTEMS OPERATION & MAINTENANCE MANUAL

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

HORIZONTAL MULTISTAGE PUMPS

AquaBoost. Variable Speed Constant Pressure Systems MODEL ABS

TECHNICAL BROCHURE B36/ /3742 CLOSE-COUPLED AND FRAME-MOUNTED CENTRIFUGAL PUMPS

Aquavar SPD Plus SIMPLEX VARIABLE SPEED SUBMERSIBLE AND ABOVE GROUND PUMP CONTROLLER BRSPDP R2

Series FILE NO: DATE: Feb. 15, 1999 SUPERSEDES: DATE: Dec. 15, Hydropak Booster Systems

GRUNDFOS PRODUCT GUIDE. BoosterpaQ Hydro MPC. Booster sets with 2 to 6 pumps 60 Hz

ADVANCED PID TROUBLESHOOTING

DETAILED EQUIPMENT SPECIFICATION MDAS SERIES DEALKALIZERS

Commercial Softeners

Kohaku. Kohaku 750 Series. Sequel NO equal

The pumps shall be Oil Free and Variable speed controlled by Pressure Transducer, PLC and inverter.

LAWN SPRINKLER, IRRIGATION PUMP

Transcription:

DuraMACTM Booster Pumps Residential Light Commercial Commercial Industrial TM 11/15

Table of Contents Page Features Residential & Light Commercial/Irrigation...2-5 Page General Information Features (Vertical Multistage... 16-17 Residential Booster...6-7 Variable Speed - Simplex... 18-19 Light Commercial & Irrigation...8-9 Variable Speed - Duplex... -21 Dual-Mode Modular... -11 Technical Information... 22-29 Dual-Mode Simplex... 12-13 Repair Parts... -32 Dual-Mode Duplex... 14-15 Not all boosting applications require complicated boosting systems. The DuraMAC TM Booster System is simple, versatile, sophisticated, and reliable. Quite simply, it is the World s Most Versatile Boosting System. Typical Installations PRIME PLUG Versatile It is the first booster pump of its kind to be designed for virtually all boosting applications. In Pressure Mode, the pump starts with pressure drop and stops on low flow. In Flow Mode, the pump starts and stops by sensing flow. In Conservation Mode, the pump only operates during a peak demand, such as when multiple showers, bathtubs, or irrigation systems are running. PUMP FILL PLUG STAND PIPE OUTLET Simple A single-speed, totally enclosed fan-cooled motor drives the DuraMAC booster pump with single phase power. It is controlled with one dial and tells you it is working properly by illuminating a single status light. The settings and readouts are simple and straight forward. SUCTION PIPE Sophisticated A pressure transducer constantly monitors system pressure and alerts the pump control to start the pump as water in the system is used. The pump then stays on, boosting the system pressure until the need for water is no longer present, indicated by low flow. VALVE UNION VALVE FOOT VALVE Reliable Electronic components are completely separated from piping and water ways for added safety and ease of field repair. The DuraMAC is built from scratch with one purpose in mind - boosting water pressure. Each component of the system is specifically designed to work together, as one harmonious unit. CHECK VALVE UNION PUMP FILL PLUG VALVE OUTLET BYPASS VALVE CLOSED INLET PRESSURE REDUCING VALVE (SEE INSTRUCTIONS) 2 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

The World s Most Versatile Booster System Pressure Tank Eliminates short cycling and helps accommodate thermal expansion. Pressure Gauge Displays total system pressure Features Circuit Board Sophisticated programming assures proper operation in all conditions. Digital Control Single knob for simple pressure adjustment. Status light indicates standby, run and fault modes Transducer Constantly monitors system pressure. Inlet w/check Valve: Residential No-Lead Brass NPT thread with large wrench flats for easy & secure pipe connections Inlet w/check Valve: Light Commercial No-Lead Brass NPT thread with large wrench flats for easy & secure pipe connections TM A.Y. McDonald s Full Line of DuraMAC Booster Pumps Union Swivel Allows for 3 o adjustment of discharge. Motor Totally enclosed fan-cooled motor for quiet operation and low power consumption Pump All stainless construction for tough water conditions. Vertical Multistage Variable Speed Simplex & Duplex Boosters Dual-Mode Modular, Simplex, & Duplex Residential, Light Commercial, & Irrigation Boosters 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 3

DuraMAC Boosters How to Order 17 044 C 0 Series Water Pressure at 0 GPM 035 0 044 052 0 062 0 078 Type R - Residential C - Commercial GPM 0 035 0 1 Order by Model Number - Example: 144C0PC2-M P C 2 - M Voltage 1-115V 2-2V Phase Modular Simplex Duplex MODELS AVAILABLE Residential, Light Commercial, & Irrigation Boosters 135R0PC1 152R0PC1 1R0PC2 1C035PC2 162C035PC2 178C035PC2 MODELS AVAILABLE Dual-Mode - Modular, Simplex, & Duplex Models 144C0PC2-S 1C0PC2-S 144C0PC2-M 1C0PC2-M 144C1PC2-D 1C1PC2-D 4 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

DuraMAC Boosters Features How It Works The DuraMAC TM Water Pressure Boosting System can be set to three separate modes, which can accommodate virtually any application. PRESSURE MODE START METHOD: Pressure drop STOP METHOD: Low flow TYPICAL INSTALLATION: Appropriate for the majority of light commercial or residential applications RESULT: Pump operates continuously while there is a need for water FLOW MODE START METHOD: Water flow STOP METHOD: Low flow TYPICAL INSTALLATION: Application where pressure fluctuates, or occasional system leaks are present RESULT: Pump operates when usage of water exceeds approximately one gallon per minute CONSERVATION MODE START METHOD: Pressure drop STOP METHOD: Low Flow TYPICAL INSTALLATION: Application where pressure is adequate for most uses, and boosting is only necessary for high demand RESULT: Pump will operate only when system pressure is below city supplied pressure and operates continuously while there is demand for water DuraMAC TM Residential, Light Commercial, Irrigation, & Dual-Mode Pump Control 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 5

DuraMAC Boosters DuraMAC - Residential Booster Not all boosting applications require complicated boosting systems. The DuraMAC Boosting system is simple, versatile, sophisticated, and reliable. Quite simply, it is the world s most versatile boosting system for residential use. Features - Easy set-up installation - Digital control for three modes of operation - Durable stainless steel and no-lead brass connections - Two gallon pressure tank included - TEFC single phase motor for quiet operation - Electronics separated and sealed from waterway - Pressure gauge included - No-Lead brass check valve included - Dry-Run protection See Pumps & Accessories Price List for Limited Warranty details. 80 TM DuraMAC 1R0PC2 + Performance Curve (Additional Boost) Pressure 152R0PC1 135R0PC1 +52 +35 0 0 5 15 Flow GPM 6 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

DuraMAC Boosters DuraMAC - Residential Booster Sizing Information DuraMAC Booster Systems are designed to shut off when no flow is detected. Pump pressure boost should be added to current system pressure to determine total system pressure when boosted. Example: Household system pressure before boost = + = Household Total Pump Total Pressure Pressure Pressure After Boost Models Available: Boost 135R0PC1 +35 152R0PC1 +52 1R0PC2 + + 35 = 65 Household Total Pump Total Pressure Pressure Pressure After Boost *Not Recommended to Exceed 80 Based on this example, the recommended model for this application is the 135R0PC1. For systems with fluctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80. Typical Installation ADD AND MEASURE AIR PRESSURE HERE NOTE: WATER PRESSURE MUST BE 0 WHEN ADJUSTING AIR PRESSURE 8 Materials of Construction Impellers Pump Casing Inlet Pump Casing Outlet Pump Seal (stationary) Pump Seal (rotating) Diffuser Suction Check Valve Pump Control Body Sizing Chart 1 Stainless Steel 1 Stainless Steel Silicon Carbide Carbon / NBR No-Lead Brass No-Lead Brass Total static pressure DuraMAC pump Incoming 135R0PC1 152R0PC1 1R0PC2 Pressure () 55 +35 90 +52 + 85 45 80 75 35 87 65 82 25 77 55 72 90 15 67 85 45 62 80 NOT RECOMMENDED 25 4 5.5 *L 8 4.25 1"Female NPT 1"Male NPT 4.25 11.2 3.5 *See chart on page 6 3 Gallon/Minute (GPM) Max DuraMAC Model Pump Boost Amps Length Voltage Power * Pressure Reducing Valve L recommended for installation with incoming pressure greater than: 135R0PC1 35 5.5 15.26 1 - Hz 1/2 HP 45 152R0PC1 52 7.0 15.97 1 - Hz 3/4 HP 28 1R0PC2 4.0 16.68 2 - Hz 1 HP (For use with holding tank) *Many plumbing codes do not recommend system pressure exceeding 80. Refer to local plumbing codes for maximum boosted pressure. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 7

DuraMAC Boosters DuraMAC - Light Commercial & Irrigation Not all boosting applications require complicated boosting systems. The DuraMAC Boosting system is simple, versatile, sophisticated, and reliable. With an easy set-up installation and a versatile control with three modes of operation, this pump is flexible enough to meet your commercial or irrigation needs. Features - Easy set-up installation - Digital control with three modes of operation - Durable stainless steel and no-lead brass connections - Two gallon pressure tank included - TEFC single phase motor for quiet operation - Electronics separated and sealed from waterway - Pressure gauge included - No-Lead brass check valve included - Dry-Run protection See Pumps & Accessories Price List for Limited Warranty details. 80 DuraMACTM 178C035PC2 +78 Performance Curve (Additional Boost) Pressure 162C035PC2 1C035PC2 +62 + 0 0 5 15 Flow GPM 25 35 8 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

80 90 0 DuraMAC Boosters DuraMAC - Light Commercial & Irrigation Sizing Information DuraMAC Booster Systems are designed to shut off when no flow is detected. Pump pressure boost should be added to current system pressure to determine total system pressure when boosted. Example: System pressure before boost = + = Current Total Pump Total Pressure Pressure Pressure After Boost Models Available: Boost 1C035PC2 + 162C035PC2 +62 178C035PC2 +78 + = Current Total Pump Total Pressure Pressure Pressure After Boost *Not Recommended to Exceed 80 Based on this example, the recommended model for this application is the 1C035PC2. For systems with fluctuating pressure, a pressure reducing valve is recommended to assure system pressure stays below 80. Typical Installation ADD AND MEASURE AIR PRESSURE HERE NOTE: WATER PRESSURE MUST BE 0 WHEN ADJUSTING AIR PRESSURE. Materials of Construction Impellers Pump Casing Inlet Pump Casing Outlet Pump Seal (stationary) Pump Seal (rotating) Diffuser Suction Check Valve Pump Control Body 1 Stainless Steel 1 Stainless Steel Silicon Carbide Carbon / NBR No-Lead Brass No-Lead Brass 25" 4" 5.5" 1" FEMALE NPT 1 1/4" FEMALE NPT Sizing Chart Total static pressure DuraMAC pump Incoming 1C035PC2 162C035PC2 178C035PC2 Pressure + +62 +78 () 55 90 45 85 80 35 75 25 65 87 82 15 55 77 93 72 88 NOT RECOMMENDED *L 8" 4.3".8" 3.5" *See chart on page 8 35 Gallon/Minute (GPM) Max DuraMAC Model Pump Boost Amps Length Voltage Power * Pressure Reducing Valve L recommended for installation with incoming pressure greater than: 1C035PC2 5.0 15.43 2 - Hz 1 HP 162C035PC2 62 6.3 16.49 2 - Hz 1 HP 18 178C035PC2 78 6.8 17.55 2 - Hz 1 1/2 HP 2 (For use with Holding Tank) *Many plumbing codes do not recommend system pressure exceeding 80. Refer to local plumbing codes for maximum boosted pressure. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 9

DuraMAC Boosters DuraMAC - Dual-Mode Modular Not all boosting applications require complicated boosting systems. The DuraMAC Boosting system is simple, versatile, sophisticated, and reliable. With a quick and easy installation, and unique digital control featuring dual modes of operation, this pump can meet your unique commercial or irrigation needs. Features - Easy set-up installation - Digital control with dual modes of operation - Durable stainless steel and no-lead brass connections - TEFC single phase motor for quiet operation - Electronics separated and sealed from waterway - Pressure gauge included - No-Lead brass check valve included (meets no-lead compliance) See Pumps & Accessories Price List for Limited Warranty details. 80 DuraMACTM Performance Curve (Additional Boost) Pressure + +44 144C0PC2-M 1C0PC2-M 0 0 Flow GPM 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

PRESSURE START FLOW STOP C US TM 150PC2 DuraMAC PUMP CONTROL DUAL~MODE 2VAC HZ 8.8 FLA 48 LRA STAND BY RUN AIR PRESSURE IN TANK SHOULD BE 2 LESS THAN START PRESSURE FOR INDOOR USE ONLY PRESSURE START PRESSURE STOP MIN FAULT WWW.AYBOOSTERS.COM RESET / TEST 80 0 90 Control Features The DuraMAC Dual-Mode control has the flexibility to be run in two different modes. PRESSURE MODE START METHOD: Pressure Drop STOP METHOD: Low Flow In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the flow is less than three Gallons per Minute. This smart system will only run the pump when water is in use. There is a preset seven second delay after water is not flowing past the flow sensor to fully pressurize your system and eliminate water hammer. FLOW MODE START METHOD: Water Flow DuraMAC Boosters DuraMAC - Dual-Mode Modular 5.43" 4.96" 15.1" 1 1/2" NPT Check Valve 1 1/2" NPT 21.5" 4.25" 7.3" Dual-Mode Modular Shown. Skid mounted Simplex and Duplex available. STOP METHOD: Low Flow In Flow Mode, the control will start and stop on flow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting flow rate is approximately five Gallons per Minute. The pump will stop when the flow is less than three Gallons per Minute. 4.65" Materials of Construction Impellers Pump Casing Inlet 1 Stainless Steel Pump Casing Outlet 1 Stainless Steel Pump Seal (stationary) Silicon Carbide Pump Seal (rotating) Carbon / NBR Diffuser Union Connection No-Lead Brass Check Valve No-Lead Brass Pump Control No-Lead Brass Motor - Single Phase 2 HP TEFC FLOW START PRESSURE 0 SET -15 BELOW BOOSTED PRESSURE PUSH RESET STAND BY TM 0 PC2 DuraMAC PUMP CONTROL 2VAC HZ 8 FLA 48 LRA RUN PUMP STARTS ON PRESSURE PUMP STOPS ON LOW FLOW START PRESSURE INSTRUCTIONS UNDER ROUND COVER TO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESET AIR PRESSURE IN TANK SHOULD BE 2 LESS THAN START PRESSURE FOR INDOOR USE ONLY WWW.AYBOOSTERS.COM FAULT RESET Gallon/Minute (GPM) Max DuraMAC Model Description Pump Boost Amps Voltage Power * Pressure Reducing Valve recommended for installation with incoming pressure greater than: 144C0PC2-M 2V Booster System 44 7.0 2 - Hz 2 HP 36 1C0PC2-M 2V Booster System 8.0 2 - Hz 2 HP Pressure tank required. See instruction manual for sizing information. *Many plumbing codes do not recommend system pressure exceeding 80. Refer to local plumbing codes for maximum boosted pressure. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11

DuraMAC Boosters DuraMAC - Dual-Mode Simplex Not all boosting applications require complicated boosting systems. The DuraMAC Boosting system is simple, versatile, sophisticated, and reliable. With the ability to pump up to GPM this unique pump is ideal for commercial or irrigation use. Features - Easy set-up installation - Digital control with dual modes of operation - Durable stainless steel and no-lead brass connections - TEFC single phase motor for quiet operation - Electronics separated and sealed from waterway - Pressure gauge included - No-Lead brass check valve included - Up to GPM - gallon pressure tank included - Stainless steel base - Dry run protection See Pumps & Accessories Price List for Limited Warranty details. 80 DuraMACTM Performance Curve (Additional Boost) Pressure + +44 144C0PC2-S 1C0PC2-S 0 0 Flow GPM 12 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

Control Features The DuraMAC Dual-Mode control has the flexibility to be run in two different modes. PRESSURE MODE START METHOD: Pressure Drop STOP METHOD: Low Flow In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the flow is less than three Gallons per Minute. 34" DuraMAC Boosters DuraMAC - Dual-Mode Simplex 1 1/2" NPT 24.5" 1 1/2" NPT This smart system will only run the pump when water is in use. There is a preset seven second delay after water is not flowing past the flow sensor to fully pressurize your system and eliminate water hammer. 6.2" 18" 28" Simplex base mounted with gallon tank. FLOW MODE START METHOD: Water Flow STOP METHOD: Low Flow In Flow Mode, the control will start and stop on flow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting flow rate is approximately five Gallons per Minute. The pump will stop when the flow is less than three Gallons per Minute. Materials of Construction Impellers Pump Casing Inlet 1 Stainless Steel Pump Casing Outlet 1 Stainless Steel Pump Seal (stationary) Silicon Carbide Pump Seal (rotating) Carbon / NBR Diffuser Union Connection No-Lead Brass Check Valve No-Lead Brass Pump Control No-Lead Brass Motor - Single Phase 2 HP TEFC Base FLOW START PRESSURE 0 SET -15 BELOW BOOSTED PRESSURE PUSH RESET STAND BY TM 0 PC2 DuraMAC PUMP CONTROL 2VAC HZ 8 FLA 48 LRA RUN PUMP STARTS ON PRESSURE PUMP STOPS ON LOW FLOW START PRESSURE INSTRUCTIONS UNDER ROUND COVER TO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESET AIR PRESSURE IN TANK SHOULD BE 2 LESS THAN START PRESSURE FOR INDOOR USE ONLY WWW.AYBOOSTERS.COM FAULT RESET Gallon/Minute (GPM) Max DuraMAC Model Description Pump Boost Amps Voltage Power * Pressure Reducing Valve recommended for installation with incoming pressure greater than: 144C0PC2-S 2V Booster System 44 7.0 2 - Hz 2 HP 36 1C0PC2-S 2V Booster System 8.0 2 - Hz 2 HP Pressure tank required. See instruction manual for sizing information. *Many plumbing codes do not recommend system pressure exceeding 80. Refer to local plumbing codes for maximum boosted pressure. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 13

DuraMAC Boosters DuraMAC - Dual-Mode Duplex Not all boosting applications require complicated boosting systems. The DuraMAC Boosting system is simple, versatile, sophisticated, and reliable. Quite simply, it is the world s most versatile boosting system for commercial or irrigation use. Features - Easy set-up installation - Digital control with dual modes of operation - Durable stainless steel and no-lead brass connectionsctions - TEFC single phase motor for quiet operation - Electronics separated and sealed from waterway - Pressure gauge included - No-Lead brass check valve included - Designed for Lead-Lag - Up to 1 GPM - gallon pressure tank included - Stainless steel base - Dry run protection See Pumps & Accessories Price List for Limited Warranty details. Pressure DuraMACTM + +44 144C1PC2-D 1C1PC2-D Performance Curve (Additional Boost - Both Pumps Running) 0 0 80 0 1 Flow GPM 14 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

Control Features The DuraMAC Dual-Mode control has the flexibility to be run in two different modes. DuraMAC Boosters DuraMAC - Dual-Mode Duplex PRESSURE MODE START METHOD: Pressure Drop STOP METHOD: Low Flow In Pressure Mode, the control accurately measures pressure with a pressure transducer and starts the pump at an adjustable start pressure point. The pump will stop when the flow is less than three Gallons per Minute. This smart system will only run the pump when water is in use. There is a preset seven7 second delay after water is not flowing past the flow sensor to fully pressurize your system and eliminate water hammer. 2" NPT 34" 28.5" 2" NPT 6.2" 27" 36" Duplex base mounted with -gallon tank 2 NPT manifolds with ball valves. FLOW MODE START METHOD: Water Flow STOP METHOD: Low Flow In Flow Mode, the control will start and stop on flow, regardless of pressure. This method can be used for systems with minor leaking or when incoming pressure varies. The starting flow rate is approximately five Gallons per Minute. The pump will stop when the flow is less than three Gallons per Minute. Materials of Construction Impellers Pump Casing Inlet 1 Stainless Steel Pump Casing Outlet 1 Stainless Steel Pump Seal (stationary) Silicon Carbide Pump Seal (rotating) Carbon / NBR Diffuser Union Connection No-Lead Brass Check Valve No-Lead Brass Pump Control No-Lead Brass Motor - Single Phase 2 HP TEFC Base FLOW START PRESSURE 0 SET -15 BELOW BOOSTED PRESSURE PUSH RESET STAND BY TM 0 PC2 DuraMAC PUMP CONTROL 2VAC HZ 8 FLA 48 LRA RUN PUMP STARTS ON PRESSURE PUMP STOPS ON LOW FLOW START PRESSURE INSTRUCTIONS UNDER ROUND COVER TO CLEAR A FAULT, CHECK FOR FLOW, THEN DECREASE START PRESSURE AND PUSH RESET AIR PRESSURE IN TANK SHOULD BE 2 LESS THAN START PRESSURE FOR INDOOR USE ONLY WWW.AYBOOSTERS.COM FAULT RESET 1 Gallon/Minute (GPM) Max DuraMAC Model Description Pump Boost Amps Voltage Power * Pressure Reducing Valve recommended for installation with incoming pressure greater than: 144C1PC2-D 2V Booster System 44 7.0 2 - Hz 2 HP 36 1C1PC2-D 2V Booster System 8.0 2 - Hz 2 HP Pressure tank required. See instruction manual for sizing information. *Many plumbing codes do not recommend system pressure exceeding 80. Refer to local plumbing codes for maximum boosted pressure. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 15

Vertical Multistage Variable Speed Simplex & Duplex Systems How to Order a Vertical Multistage Simplex/Duplex System Order by Model Number - Example: 1V1Y-34 17 0 V 1 Y - 3 4 Series Water Pressure at 0 GPM 056 062 084 088 4 1 142 1 Variable Speed GPM 080 1 1 1 2 280 Yaskawa Drive Phase 1 - Single Phase 3 - Three Phase Volts 4-4V Leave blank for 8/2 volts (standard) MODELS AVAILABLE Simplex Models MODELS AVAILABLE Duplex Models 162V080Y-1 162V080Y-3 184V080Y-1 184V080Y-3 174V080Y-1 174V080Y-3 171V080Y-3 17142V1Y-3 156V1Y-1 1V1Y-3 188V1Y-3 162V1Y-1 162V1Y-3 184V1Y-1 184V1Y-3 174V1Y-1 174V1Y-3 171V1Y-3 17142V2Y-3 156V2Y-1 1V280Y-3 188V280Y-3 16 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

Vertical Multistage Variable Speed Features How It Works The Yaskawa iqpump 00 drive features powerful software combined with an internal PLC to deliver multiple features that are designed help protect the drive, pump, motor, and entire pumping system. While many of these features are factory programmed and set, many features depend on the specific pumping application and may be required to be set during install. Changing certain parameters while the drive and pump are running may cause unwanted behavior. It is recommended to turn the drive off before changing parameter values. To return to home screen, hold for 3 seconds, or press. The display should look similar to the one below. Once at the home screen, additional drive status can be viewed by pressing. Additional drive information includes output frequency, current, voltage, DC bus voltage, and kilowatts. Digital Operator Keypad Alarm light blinks if alarm or fault occurs. Pump Output Frequency Transducer Feedback (Actual System Pressure) System Outlet Pressure Auto Setpoint Press to turn HAND mode on. Use only for Priming and troubleshooting. Pump will run at a fixed speed. Do not run against a closed discharge. Press to turn AUTO mode on. If LED is blinking, Auto mode is active but pump is sleeping. Press to turn system off. DuraMAC TM Vertical Multistage Variable Speed Simplex/Duplex Booster Pump Control Features - Set it and forget it technology - Set point at, but can be easily be changed in the field - Extremely reliable - Proven product - Yaskawa Drive 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 17

DuraMAC Boosters DuraMAC - Vertical Multistage Variable Speed Simplex Booster System The DuraMAC Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems. Features - Easy set-up installation* - Variable speed control - Stainless steel pump - Energy efficient NEMA TEFC motors - Liquid filled gauges - Wafer check valves with soft seat - Stainless steel base - 2 Brass No-Lead isolation valves - NEMA 1 enclosure - Suction and discharge transducers - Fused disconnect - 2 Suction and discharge See Pumps & Accessories Price List for Limited Warranty details. 1 1 TM DuraMAC 171V080 Hz Pump Performance One Pump Running 1 1 1 1 174V080 Pressure 0 90 80 184V080 162V080 17142V1 188V1 156V1 1V1 0 0 80 90 0 1 1 1 1 1 1 *Pressure Tank Required (not included). Flow GPM 18 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

DuraMAC Boosters DuraMAC - Vertical Multistage Variable Speed Simplex Booster System Control Features - Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure. - Date and time stamp for all faults. - Better system efficiency by applying only the power needed based on the load. - Password protected parameter settings. - Real time clock. - No Flow Mode - puts pump to sleep during no flow conditions. - Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted. IN CHECK VALVE - Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability. - Live Zero protects the pump if the transducer cable is broken or damaged. OUT 4.6 Materials of Construction Impellers Pump Casing Inlet Pump Casing Outlet Pump Seal (stationary) 1 Stainless Steel 1 Stainless Steel Silicon Carbide Pump Seal (rotating) Diffuser Base Carbon / NBR 4 Stainless steel MODELS AVAILABLE Model Description Pump Boost Voltage HP 162V080Y-1 62 2V VFD Booster 62 8-2 Single Phase 3 162V080Y-3 62 2V VFD Booster 62 8-2 Three Phase 3 184V080Y-1 84 2V VFD Booster 84 8-2 Single Phase 5 184V080Y-3 84 2V VFD Booster 84 8-2 Three Phase 5 174V080Y-1 4 2V VFD Booster 4 8-2 Single Phase 5 174V080Y-3 4 2V VFD Booster 4 8-2 Three Phase 5 171V080Y-3 1 2V VFD Booster 1 8-2 Three Phase 7 1/2 17142V1Y-3 142 2V VFD Booster 142 8-2 Three Phase 156V1Y-1 56 2V VFD Booster 56 8-2 Single Phase 5 1V1Y-3 2V VFD Booster 8-2 Three Phase 5 188V1Y-3 88 2V VFD Booster 88 8-2 Three Phase 7 1/2 4 volt version also available A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 19

DuraMAC Boosters DuraMAC - Vertical Multistage Variable Speed Duplex Booster System The DuraMAC Boosting system is simple, versatile, sophisticated, and reliable. The Vertical Multistage Variable Speed Booster System changes motor speed based on demands of the system, which allows users to save energy costs over traditional constant speed booster systems. Features - Easy set-up installation* - Variable speed control - Stainless steel pump - Energy efficient NEMA TEFC motors - Liquid filled gauges - Wafer check valves with soft seat - Stainless steel base - 2 Brass No-Lead isolation valves - NEMA 1 enclosure - Suction and discharge transducers - Fused disconnect - 3 Flanged stainless steel manifolds 1 1 1 TM DuraMAC 171V1 See Pumps & Accessories Price List for Limited Warranty details. Hz Pump Performance Both Pumps Running 1 1 1 174V1 Pressure 0 90 80 184V1 162V1 17142V2 188V280 156V2 1V280 0 0 80 0 1 1 1 180 0 2 2 2 280 0 3 *Pressure Tank Required (not included). Flow GPM 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

Control Features DuraMAC Boosters DuraMAC - Vertical Multistage Variable Speed Duplex Booster System - Variable speed control, speeds up and slows down based on the demand of system, maintaining a constant pressure. - Lead - Lag pump control to alternate pump starts, allowing equal run times on all pumps for longer life cycles. - Better system efficiency by applying only the power needed based on the load. - Password protected parameter settings. - Real time clock. - No Flow Mode - puts pump to sleep during no flow conditions. - Low Suction Alarm to prevent the pump from running if the incoming supply of water is interrupted. - Internal monitors prevent the pump from running if a pipe is broken or demand exceeds capability. - Live Zero protects the pump if the transducer cable is broken or damaged. - Backup system transducer for pump and drive redundancy. 46 4.6 31 48 Materials of Construction Impellers Pump Casing Inlet Pump Casing Outlet Pump Seal (stationary) 1 Stainless Steel 1 Stainless Steel Silicon Carbide Pump Seal (rotating) Diffuser Base Carbon / NBR 4 Stainless steel MODELS AVAILABLE Model Description Pump Boost Voltage HP 162V1Y-1 62 2V VFD Booster 62 8-2 Single Phase 3 162V1Y-3 62 2V VFD Booster 62 8-2 Three Phase 3 184V1Y-1 84 2V VFD Booster 84 8-2 Single Phase 5 184V1Y-3 84 2V VFD Booster 84 8-2 Three Phase 5 174V1Y-1 4 2V VFD Booster 4 8-2 Single Phase 5 174V1Y-3 4 2V VFD Booster 4 8-2 Three Phase 5 171V1Y-3 1 2V VFD Booster 1 8-2 Three Phase 7 1/2 17142V2Y-3 142 2V VFD Booster 142 8-2 Three Phase 156V2Y-1 56 2V VFD Booster 56 8-2 Single Phase 5 1V280Y-3 2V VFD Booster 8-2 Three Phase 5 188V280Y-3 88 2V VFD Booster 88 8-2 Three Phase 7 1/2 4 volt version also available A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 21

DuraMAC Boosters DuraMAC - 156V1Y Simplex / 156V2Y Duplex Technical Information & Performance Curves 80 DuraMACTM Hz Pump Performance 156V1Y Simplex / 156V2Y Duplex Pressure Simplex Duplex 0 0 80 90 0 1 1 1 0 80 0 1 1 1 180 0 2 2 2 Flow GPM Technical Information Max Boost 56 Suction Transducer 0-1 4-mA Discharge Transducer 0-1 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 184TC Horsepower 5 Seal Material Carbon/Sic Electrical 8-2V 1 Phase Base Technical Information - Simplex Model Number Tank Required 156V1Y-1 1 GPM 32 Gallon Technical Information - Duplex Model Number Tank Required 156V2Y-1 2 GPM 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 22 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

DuraMAC Boosters DuraMAC - 1V1Y Simplex / 1V280Y Duplex Technical Information & Performance Curves DuraMACTM Hz Pump Performance Pressure 1V1Y Simplex / 1V280Y Duplex Simplex Duplex 0 0 80 90 0 1 1 1 1 1 1 0 80 0 1 1 1 180 0 2 2 2 280 0 3 Flow GPM Technical Information Max Boost Suction Transducer 0-1 4-mA Discharge Transducer 0-1 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 184TC Horsepower 5 Seal Material Carbon/Sic Base Technical Information - Simplex Model Number Electrical Tank Required 1V1Y-3 1 GPM 8-2V 3 Phase 36 Gallon Technical Information - Duplex Model Number Electrical Tank Required 1V280Y-3 280 GPM 8-2V 3 Phase 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 23

DuraMAC Boosters DuraMAC - 162V080Y Simplex / 162V1Y Duplex Technical Information & Performance Curves 80 DuraMACTM Hz Pump Performance 162V080Y Simplex / 162V1Y Duplex Pressure Simplex Duplex 0 0 80 0 80 0 1 1 1 Flow GPM Technical Information Max Boost 62 Suction Transducer 0-1 4-mA Discharge Transducer 0-1 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 182TC Horsepower 3 Seal Material Carbon/Sic Base Technical Information - Simplex Model Number Electrical Tank Required 162V080Y-1 80 GPM 8-2V 1 Phase Gallon Model Number 162V080Y-3 80 GPM Electrical 8-2V 3 Phase Tank Required Gallon Technical Information - Duplex Model Number Electrical Tank Required 162V1Y-1 1 GPM 8-2V 1 Phase 52 Gallon Minimum Model Number 162V1Y-3 1 GPM Electrical 8-2V 3 Phase Tank Required 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 24 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

DuraMAC Boosters DuraMAC - 184V080Y Simplex / 184V1Y Duplex Technical Information & Performance Curves 0 DuraMACTM Hz Pump Performance 90 184V080Y Simplex / 184V1Y Duplex 80 Pressure Simplex Duplex 0 0 80 0 80 0 1 1 1 Flow GPM Technical Information Max Boost 84 Suction Transducer 0-1 4-mA Discharge Transducer 0-1 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 184TC Horsepower 5 Seal Material Carbon/Sic Base Technical Information - Simplex Model Number Electrical Tank Required 184V080Y-1 80 GPM 8-2V 1 Phase Gallon Model Number 184V080Y-3 80 GPM Electrical 8-2V 3 Phase Tank Required Gallon Technical Information - Duplex Model Number Electrical Tank Required 184V1Y-1 1 GPM 8-2V 1 Phase 52 Gallon Minimum Model Number 184V1Y-3 1 GPM Electrical 8-2V 3 Phase Tank Required 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 25

DuraMAC Boosters DuraMAC - 188V1Y Simplex / 188V280Y Duplex Technical Information & Performance Curves 0 DuraMACTM Hz Pump Performance 90 Pressure 80 188V1Y Simplex / 188V280Y Duplex Simplex Duplex 0 0 80 90 0 1 1 1 1 1 1 0 80 0 1 1 1 180 0 2 2 2 280 0 3 Flow GPM Technical Information Max Boost 88 Suction Transducer 0-1 4-mA Discharge Transducer 0-1 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 213TC Horsepower 7 1/2 Seal Material Carbon/Sic Electrical 8-2V 3 Phase Base Technical Information - Simplex Model Number Tank Required 188V1Y-3 1 GPM 36 Gallon Technical Information - Duplex Model Number Tank Required 188V280Y-3 280 GPM 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 26 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

DuraMAC Boosters DuraMAC - 174V080Y Simplex / 174V1Y Duplex Technical Information & Performance Curves 1 DuraMACTM Hz Pump Performance 1 0 174V080Y Simplex / 174V1Y Duplex 90 80 Pressure Simplex Duplex 0 0 80 0 80 0 1 1 1 Flow GPM Technical Information Max Boost 4 Suction Transducer 0-1 4-mA Discharge Transducer 0-1 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 184TC Horsepower 5 Seal Material Carbon/Sic Base Technical Information - Simplex Model Number Electrical Tank Required 174V080Y-1 80 GPM 8-2V 1 Phase Gallon Model Number 174V080Y-3 80 GPM Electrical 8-2V 3 Phase Tank Required Gallon Technical Information - Duplex Model Number Electrical Tank Required 174V1Y-1 1 GPM 8-2V 1 Phase 52 Gallon Minimum Model Number 174V1Y-3 1 GPM Electrical 8-2V 3 Phase Tank Required 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 27

DuraMAC Boosters DuraMAC - 17142V1Y Simplex / 17142V2Y Duplex Technical Information & Performance Curves 1 1 1 1 1 DuraMACTM Hz Pump Performance 17142V1Y Simplex / 17142V2Y Duplex 1 Pressure 0 90 80 Simplex Duplex 0 0 80 90 0 1 1 1 0 80 0 1 1 1 180 0 2 2 2 Flow GPM Technical Information Max Boost 142 Suction Transducer 0-1 4-mA Discharge Transducer 0-1 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 215TC Horsepower Seal Material Carbon/Sic Electrical 8-2V 3 Phase Base Technical Information - Simplex Model Number Tank Required 17142V1Y-3 1 GPM 32 Gallon Technical Information - Duplex Model Number Tank Required 17142V2Y-3 2 GPM 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 28 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

DuraMAC Boosters DuraMAC - 171V080Y Simplex / 171V1Y Duplex Technical Information & Performance Curves 1 1 DuraMACTM Hz Pump Performance 1 1 1 1 171V080Y Simplex / 171V1Y Duplex 0 Pressure 90 80 Simplex Duplex 0 0 80 0 80 0 1 1 1 Flow GPM Technical Information Max Boost 1 Suction Transducer 0-0 4-mA Discharge Transducer 0-0 4-mA Drive - Yaskawa iq Pump NEMA 1 Suction Ball Valve 2 No-Lead Brass Discharge Ball Valve 2 No-Lead Brass Impeller Pump End Motor - Energy Eff. TEFC 213TC Horsepower 7 1/2 Seal Material Carbon/Sic Electrical 8-2V 3 Phase Base Technical Information - Simplex Model Number Tank Required 171V080Y-3 80 GPM Gallon Technical Information - Duplex Model Number Tank Required 171V1Y-3 1 GPM 52 Gallon Minimum A.Y. McDonald considers the information on this sheet correct when published. Specifications are subject to change with notice. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 29

80 90 0 Pump Repair Parts GPM Residential 135R0PC1-003 - 135R0P-1 Pump 1V Pump +35 GPM 1/2 HP 1V -001 - Repair Control 1V with Tee -009 - Repair Control 1V (Black box) -026 - Transducer TDL32K 1 5V 6127-337 - Two Gallon Diaphragm Tank -027 - Check Valve 1 MNPT x 1 MNPT -554 - Seal Kit -028 - Pressure Gauge 0-0 2 Dry 152R0PC1-004 - 152R0P-1 Pump 1V Pump +52 GPM 3/4 HP 1V -001 - Repair Control 1V with Tee -009 - Repair Control 1V (Black box) -026 - Transducer TDL32K 1 5V 6127-337 - Two Gallon Diaphragm Tank -027 - Check Valve 1 MNPT x 1 MNPT -554 - Seal Kit -028 - Pressure Gauge 0-0 2 Dry 1R0PC2-005 - 1R0P-2 Pump 2V Pump + GPM 1 HP 2V -002 - Repair Control 2V with Tee -0 - Repair Control 2V (Black box) -026 - Transducer TDL32K 1 5V 6127-337 - Two Gallon Diaphragm Tank -027 - Check Valve 1 MNPT x 1 MNPT -554 - Seal Kit -028 - Pressure Gauge 0-0 2 Dry 35 GPM Light Commercial 1C035PC2-011 - 1C035P-2 Pump 2V Pump + 35 GPM 1 HP 2V -002 - Repair Control 2V with Tee -0 - Repair Control 2V (Black box) -026 - Transducer TDL32K 1 5V 6127-337 - Two Gallon Diaphragm Tank -029 - Check Valve 1 1/4 MNPT x 1 1/4 FNPT -554 - Seal Kit -028 - Pressure Gauge 0-0 2 Dry 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

80 90 0 Pump Repair Parts 35 GPM Light Commercial (Continued) 162C035PC2-012 - 162C035P-2 Pump 2V Pump +62 35 GPM 1 HP 2V -002 - Repair Control 2V with Tee -0 - Repair Control 2V (Black box) -026 - Transducer TDL32K 1 5V 6127-337 - Two Gallon Diaphragm Tank -029 - Check Valve 1 1/4 MNPT x 1 1/4 FNPT -554 - Seal Kit -028 - Pressure Gauge 0-0 2 Dry 178C035PC2-013 - 178C035P-2 Pump 2V Pump +78 35 GPM 1 1/2 HP 2V -002 - Repair Control 2V with Tee -0 - Repair Control 2V (Black box) -026 - Transducer TDL32K 1 5V 6127-337 - Two Gallon Diaphragm Tank -029 - Check Valve 1 1/4 MNPT x 1 1/4 FNPT -554 - Seal Kit -028 - Pressure Gauge 0-0 2 Dry GPM Dual Mode - Modular, Simplex, & Duplex 144C0PC2-M 144C0PC2-S 144C1PC2-D -017-144C0P-2 Pump 2V Pump +44 GPM 2V -026 - Transducer TDL32K 1 5V 11-009 - Dual-Mode Control Repair (Black box) 11-012 - Paddle Switch 6127-341 - 1MV4F - Pressure Tank 11-011 - Pressure Gauge 0-0 2 1/2 Liquid filled -555 - Seal Kit 5424-1 - Ball Valve 1/4 MNPT x 1/4 FNPT (Test Cock) Dual-Mode Simplex 1C0PC2-M 1C0PC2-S 1C1PC2-D -018-1C0P-2 Pump 2V Pump + GPM 2V -026 - Transducer TDL32K 1 5V 11-009 - Dual-Mode Control Repair (Black box) 11-012 - Paddle Switch 6127-341 - 1MV4F - Pressure Tank 11-011 - Pressure Gauge 0-0 2 1/2 Liquid filled -555 - Seal Kit 5424-1 - Ball Valve 1/4 MNPT x 1/4 FNPT (Test Cock) 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 31

Pump Repair Parts Vertical Multistage Variable Speed Booster Systems SIMPLEX / DUPLEX 12-6 - Transducer 4-mA 1 12-7 - Transducer 4-mA 0 12-8 - Transducer 4-mA 15 12-531 - Transducer Cable M12-9 ft. long 12-533 - Wafer Check Valve - 2 soft seat 12-536 - Flange gasket 2 12-9 - Seal Repair Part SiC/Carbon/EPDM 12-1 - Seal Repair Part (SiC/SiC/EPDM) - Sandy Water 12-567 - Pressure Gauge 0 Liquid filled 11-537 - Pressure Gauge 0 Liquid filled Simplex 12-575 - Yaskawa Drive 3 HP 3 Phase 2V 12-576 - Yaskawa Drive 3 HP 1 Phase 2V Yaskawa Drive 5 HP 3 Phase 2V 12-577 - Yaskawa Drive 7 1/2 HP 3 Phase 2V 12-578 - Yaskawa Drive 5 HP 1 Phase 2V Yaskawa Drive HP 3 Phase 2V 12-579 - Yaskawa Drive 5 HP 3 Phase 4V 12-580 - Yaskawa Drive 7 1/2 HP 3 Phase 4V 12-581 - Yaskawa Drive HP 3 Phase 4V 12-590 - Disconnect - Altech Amp 12-591 - Disconnect - AB Amp 12-5 - Pump end 162V080 12-521 - Pump end 184V080 12-522 - Pump end 174V080 12-523 - Pump end 171V080 12-524 - Pump end 17142V1 12-525 - Pump end 1V1 12-526 - Pump end 188V1 12-528 - Pump end 156V1 12-547 - Motor TEFC - 3 HP Energy Eff 182TC 12-548 - Motor TEFC - 5 HP Energy Eff 184TC 12-549 - Motor TEFC - 7 HP Energy Eff 213TC 12-5 - Motor TEFC - HP Energy Eff 215TC 12-551 - Motor TEFC - 15 HP Energy Eff 215TC Duplex SIMPLEX / DUPLEX - ACCESSORIES 12-0 - 1EJ 3 Flanged Expansion Joint 12-1 - 1EJ 2 Threaded Braided Hose 4 SS 12-2 - Flange Blind 3 1# 4 SS 12-3 - Flange Threaded 3 1# 4 SS 12-4 - Flange Kit Blind 3 1# 4 SS 12-5 - Flange Kit Threaded 3 1# 4 SS 32 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

Debra Arnold Plant Worker 12 Years of Service The sound of quality. Simple. Versatile. Effective. Our DuraMac Booster Pump and complete line of boosting products are unsurpassed. Built with our quality brass connections, the fittings are leakproof and reliable. Designed for virtually any commercial or residential site, they perform no matter the application. All of this, and they re quiet, too. Now, how does that sound? More than a brand. We re a family. Visit AYMcDonald.com or call 1.800.292.2737 to learn how our DuraMac Booster Pump can work for you. 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 33

Notes 34 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 11-15

Notes 11-15 800.292.2737 FAX 800.832.9296 pumps@aymcdonald.com aymcdonald.com 35

A.Y. McDonald Mfg. Co. is a leading manufacturer of Waterworks Brass, Plumbing Valves, Pumps and Water Systems, and High Pressure Gas Valves and Meter Bars. The Company has distinguished itself with a proud tradition of quality and reliability since its founding in 1856. The mission of A.Y. McDonald Mfg. Co., in the words of our founder, is to make good products and sell them honestly. We, the stockholders and employees, accomplish this by extending the McDonald family culture through excellent customer service and by focusing on our customers needs. WARNING: It is unlawful in CALIFORNIA & VERMONT (effective 1/1/); MARYLAND (effective 1/1/12); LOUISIANA (effective 1/1/13) and the UNITED STATES OF AMERICA (effective 1/4/14) to use any product in the installation or repair of any public water system or any plumbing in a facility or system that provides water for human consumption if the wetted surface area of the product has a weighted average lead content greater than 0.25%. This prohibition does not extend to service saddles used in California, Louisiana or under USA Public Law 111-380. 11/15 More than a brand. We re a family. ayboosters.com 1-800-292-2737 sales@aymcdonald.com