WM2015 Conference, March 15-19, 2015, Phoenix, Arizona, USA

Similar documents
CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

LIFE CYCLE COSTING FOR BATTERIES IN STANDBY APPLICATIONS

Effect of Compressor Inlet Temperature on Cycle Performance for a Supercritical Carbon Dioxide Brayton Cycle

LIQUEFIED GAS PUMP INSTALLATION

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

INSTRUCTIONS FOR: VACUUM TESTER AND BRAKE BLEEDING KIT

NFPA 286 STANDARD METHODS OF FIRE TESTS FOR EVALUATING CONTRIBUTION OF WALL AND CEILING INTERIOR FINISH TO ROOM FIRE GROWTH

Effect of The Use of Fuel LPG Gas and Pertamax on Exhaust Gas Emissions of Matic Motorcycle

This is a new permit condition titled, "2D.1111 Subpart ZZZZ, Part 63 (Existing Non-Emergency nonblack start CI > 500 brake HP)"

Turbostroje 2015 Návrh spojení vysokotlaké a nízkotlaké turbíny. Turbomachinery 2015, Design of HP and LP turbine connection

2015 Carbon footprint JTP. Date of issue: 14 th March 2016

Balancing of aeroderivative turbine

CFD ANALYSIS ON LOUVERED FIN

Evaluation of a Gearbox s High-Temperature Trip

VS403 INSTRUCTIONS FOR: VACUUM AND PRESSURE TEST / BRAKE BLEEDING UNIT MODEL: SAFETY INSTRUCTIONS INTRODUCTION & CONTENTS. fig.1

Technical Papers supporting SAP 2009

Original Language Version VS4021 Issue: 1-08/06/12

Vertical submersible pumps in the chemical and petrochemical industry

Design and Validation of Hydraulic brake system for Utility Vehicle

Petronas vs Shell vs BHP vs Esso: Which petrol brand gives the lowest (best) fuel consumption?

BLAST CAPACITY ASSESSMENT AND TESTING A-60 OFFSHORE FIRE DOOR

The Experimental Study of the Plateau Performance of the F6L913 Diesel Engine

Generator Efficiency Optimization at Remote Sites

Computer-Assisted Induction Aluminum

Development of Energy Balance Simulation Method for Vehicles

OIG-SR-17-01, OIG Special Report Department of Energy s Actions to Address Worker Concerns Regarding Vapor Exposures at the Hanford Tank Farms

Annex 1. Field Report: Solar Electric Light Fund Energy Harvest Control Study

DEVELOPMENT AND COMMERCIALIZATION OF ATIS-2L, A HIGH ACTIVITY, LOW COST PARAFFIN ISOMERIZATION CATALYST

DESIGN OF THROTTLE BODY: A COMPARATIVE STUDY OF DIFFERENT SHAFT PROFILES USING CFD ANALYSIS

BALL BEARING TESTS TO EVALUATE DUROID REPLACEMENTS

Increasing production speeds and customer demands

Small Oil Free Piston Type Compressor For CO2

High-force linear motion: How to convert hydraulic cylinders to electric actuators and why.

Original. M. Pang-Ngam 1, N. Soponpongpipat 1. Keywords: Optimum pipe diameter, Total cost, Engineering economic

Technical Service Bulletin IOX/DCX Transmitter Maintenance Schedule

Table 1. Sample Identification and Comparison Connectors Used in Experiments Sample Conductor Size

Product Loss During Retail Motor Fuel Dispenser Inspection

A Guide to the medium General Service. BC Hydro Last Updated: February 24, 2012

A Cost Benefit Analysis of Faster Transmission System Protection Schemes and Ground Grid Design

Pantograph and catenary system with double pantographs for high-speed trains at 350 km/h or higher

INFLUENCE OF MAGNET POLE ARC VARIATION ON THE COGGING TORQUE OF RADIAL FLUX PERMANENT MAGNET BRUSHLESS DC (PMBLDC) MOTOR

PHYSICAL MODEL TESTS OF ICE PASSAGE AT LOCKS

AMBIENT AIR QUALITY MONTHLY REPORT

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

Hydraulic Power Supply and Motors Concept and Theory

MAC Refrigerant Blend Cooperative Research Program --- Update --- Enrique Peral-Antúnez, RENAULT [ Chair person ]

in Preventing Explosions within Fired Equipment: The Role of Basic Design Data Robert Wasileski A Case Study Process Safety & Loss Prevention Engineer

SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 11 CALIBRATING INSTRUMENTS

3/12/2012 UNIT OBJECTIVES THE NEED FOR CALIBRATION SECTION 2 SAFETY, TOOLS AND EQUIPMENT, SHOP PRACTICES UNIT 11 CALIBRATING INSTRUMENTS

THE MEASUREMENT OF EXHAUST EMISSIONS FROM THE ENGINES FITTED IN AGRICULTURAL TRACTORS UNDER REAL OPERATING CONDITIONS

TECHNICAL PAPER FOR STUDENTS AND YOUNG ENGINEERS - FISITA WORLD AUTOMOTIVE CONGRESS, BARCELONA

(12) United States Patent (10) Patent No.: US 6,779,516 B1

Combustion characteristics of n-heptane droplets in a horizontal small quartz tube

Multi Body Dynamic Analysis of Slider Crank Mechanism to Study the effect of Cylinder Offset

Improve Steam Turbine Efficiency

Operation and Maintenance of different valve types

ELECTROMECHANICAL OPTIMIZATION AGAINST TORSIONAL VIBRATIONS IN O&G ELECTRIFIED TRAINS MICHELE GUIDI [GE O&G] ALESSANDRO PESCIONI [GE O&G]

FEASIBILITY STYDY OF CHAIN DRIVE IN WATER HYDRAULIC ROTARY JOINT

ND Pipeline Authority Web Presentation

e t Performance of Extended Inlet and Extended Outlet Tube on Single Expansion Chamber for Noise Reduction

Introduction: Supplied to 360 Test Labs... Battery packs as follows:

Aerodynamic device vortex generators

REPORT N O AMBIENT AIR QUALITY MONTHLY REPORT JUNE 2017

Iowa State University Electrical and Computer Engineering. E E 452. Electric Machines and Power Electronic Drives

Hybrid Drives for Mobile Equipment

Hydraulic and Commissioning Mannual Module 2A

FEATURE ARTICLE. Advanced Function Analyzers: Real-time Measurement of Particulate Matter Using Flame Ionization Detectors. Hirokazu Fukushima

D G A G R I D A S H B O A R D : A P P L E S

CHAPTER 8 EFFECTS OF COMBUSTION CHAMBER GEOMETRIES

OKLAHOMA CORPORATION COMMISSION REGULATED ELECTRIC UTILITIES 2018 RELIABILITY SCORECARD

REMOTE SENSING DEVICE HIGH EMITTER IDENTIFICATION WITH CONFIRMATORY ROADSIDE INSPECTION

MONITORING AND RESEARCH DEPARTMENT

Evaluation of photo voltaic generating system performance for fishing light application

Oscillator Experiment of Simple Girder Bridge coupled with Vehicle

Cost Benefit Analysis of Faster Transmission System Protection Systems

ISO 5011 Test Results

Module 5: Emission Control for SI Engines Lecture20:ADD-ON SYSTEMS FOR CONTROL OF ENGINE-OUT EMISSIONS

Development of Variable Geometry Turbocharger Contributes to Improvement of Gasoline Engine Fuel Economy

Numerical Study on the Flow Characteristics of a Solenoid Valve for Industrial Applications

TESTING OF AUTOMOBILE VW GOLF OPERATING ON THREE DIFFERENT FUELS

REPORT N O AMBIENT AIR QUALITY MONTHLY REPORT MAY 2017

Burn Characteristics of Visco Fuse

Analysis and Correlation for Body Attachment Stiffness in BIW

Copyright Statement FPC International, Inc

1 of 7 12/18/2016 9:15 PM

Remarkable CO 2 Reduction of the Fixed Point Fishing Plug-in Hybrid Boat

Field Verification and Data Analysis of High PV Penetration Impacts on Distribution Systems

ECTOS Deliverable 4. European Commission. Fifth Framework For Research And Development

2014 Efficiency of Automated Collection and Performance of Compressed Natural Gas Vehicles CIF Project No

A STUDY ON THE EFFECTIVITY OF HYDROGEN LEAKAGE DETECTION FOR HYDROGEN FUEL CELL MOTORCYCLES

Pressurized Air Cooled Generators

GREENER SHIPPING SUMMIT 2017

Special edition paper

Mobile Air Conditioning (MAC)

EXPERIMENTAL RESEARCH OF A COMMON RAIL SYSTEM FOR DIESEL ENGINES

Technical & Commercial Evaluation Of Steam Tracing System V/s SECT Skin Effect Heating System Electric Heat Tracing System

OWS OPERATIONS & MAINTENANCE

6. Acoustical simulation of straight and side inlet/outlet rectangular plenums using the FEM method

WM 07 Conference, February 25 March 1, 2007, Tucson, AZ. Evaluation of Glass Fiber Hepa Filters as a Function of Media Velocity

Transcription:

Hanford Single-Shell Tanks 241-T-203 and 241-T-204 Validation of Level Decrease Evaluation - 15343 Amie Feero *, John Schofield **, Jeremy Johnson *** * Washington River Protection Solutions ** Columbia Engineering and Environmental Services *** US DOE ABSTRACT Hanford single-shell tanks (SSTs) 241-T-203 (T-203) and 242-T-204 (T-204) were two tanks that showed decreasing waste surface level trends. All factors that could impact each tank s level change rate were evaluated with the conclusion being the level decreases could be explained by evaporation. The evaporation estimates contained several assumptions, so a test was performed to determine if the estimates could be supported by data. The breather filter valves on these two tanks were closed for one year in order to shut off the primary means of tank air exchange to the atmosphere. The results for tank T-203 showed the net level change for the year was zero which supported the evaporation rate estimate (and provided further information that the tank was not leaking). The data for tank T-204 were very erratic and prevented conclusive results, but the waste level showed a significant reduction in level decrease rate and supported the tank evaporation rate estimate [1]. INTRODUCTION Tanks T-203 and T-204 are 6.1 m (20 ft.) diameter tanks that had shown small waste level decreases of 7.0 x 10-11 and 5.7 x 10-11 m/s (0.087 and 0.071 in./yr), respectively, for many years. This corresponds to an estimated volume decrease rates of 6.2 x 10-10 to 2.0 x 10-9 m 3 /s (5.2 to 17 gal/yr) for tank T-203 and 7.3 x 10-10 to 1.7 x 10-9 m 3 /s (6.1 to 14 gal/yr) for tank T-204 based on conservative assumptions [2]. Because of the decreasing level and volume, these tanks were evaluated to determine what was causing the decreases. First, estimating a volume change rate from level change data is only valid if the level instrument is sensing a liquid level. In-tank videos confirmed the level gauges were sensing liquid, so the measured level decreases are valid. The original evaluation of the level decreases in T-203 and T-204 was completed by taking into account factors that could influence the waste level, including the following topics: Water intrusions Evaporation Leaks Waste subsidence Gas generation or release Conscious liquid additions (e.g., flushing the ENRAF plummet) The evaluation concluded the major factors that would cause the level decrease rate were evaporation and/or leakage. The evaporation rate was estimated from a variety of factors, including tank headspace temperatures, relative humidity, and breathing rates. Data and conservative assumptions were 1

used to estimate evaporation rates of 2.5 x 10-9 m 3 /s (21 gal/yr) for tank T-203 and 2.6 x 10-9 m 3 /s (22 gal/yr) for tank T-204. Since the estimated evaporation rate exceeded the maximum estimated liquid loss rates for each tank it was concluded evaporation could explain the liquid loss rates. However, having data to support the estimated evaporation rate was desired to provide more support for the conclusion. Closing the breather filter inlet valves reduces the tank headspace air exchange with the atmosphere and therefore the evaporation. In June 2013, the inlet valves on both Tank T-203 and Tank T-204 were closed. The valves remained closed for a full year, and during this year the liquid levels were monitored for changes. While the breather valves were closed to the tank headspace, the flammable gas surveillance frequency was increased and more stringent requirements were set to verify that the flammable gas levels in the headspace were acceptable and safe. METHODS The methods involved in confirming whether evaporation could cause the decrease in liquid surface level were rather simple. Essentially, two things needed to happen: 1. Close the breather filter inlet valves for at least a year. 2. Monitor the liquid level changes during that year. The breather filter inlet valves were closed by issuing a process memo to direct the work using existing procedures [3]. A drawing of a breather filter assembly is shown in Figure 1 below. Butterfly Valve Fig. 1. Example of Breather Filter Assembly Showing Valve [4]. 2

The liquid level changes were monitored using the ENRAF level gauge (±0.01 precision) with daily readings. Because of the potential for buildup of flammable gases in a tank headspace after closing a breather filter valve, the flammable gas levels in the tank headspace were monitored every 30 days during the year the valves were shut. The standard headspace monitoring frequency is 182 days for T-203 and T-204 when the breather filters are open. The monitoring is to verify the flammable gas concentration is 25% of the lower flammability limit (LFL) [5]. In the current operating procedure, if the flammable gas reading is higher than 5% of the LFL but less than 25%, then the ventilation must be confirmed to be in the open position [6]. Therefore, the surveillance frequency was chosen to ensure that any tank headspace flammable gas concentration increase would be observed before the concentration reached 5% of the LFL. Because 25% of the LFL could be reached in 294 days [7], 5% of the LFL could be reached in 59 days. Therefore, flammable gas measurements were made every 30 days to ensure that the flammable gas levels were safe. Over the course of the breather filter valve closure, the flammable gas readings in both tanks never registered above 0% of the LFL. RESULTS AND DISCUSSION The results are discussed by tank in the subsequent sections. Tank 241-T-203 The tank T-203 breather valve was shut in June 2013. Over the course of 12 months (starting on June 13), the level data were collected and plotted. For reference, a 10-year period of level data is shown in Figure 2. The annual liquid level fluctuations are expected for a tank where the level gauge is reading a liquid surface and are due to the annual temperature-caused density changes in the waste. The surface level before the breather filter was shut off (vertical red line), showed a decreasing trend which is what prompted the original level evaluation. The jumps in data were in the 2008-2009 timeframe were due to instrument problems. 3

Fig. 2. Tank T-203 Level Data 2004 to 2014. To more accurately compare the data before and after shutting the valve, a comparison chart was prepared showing the daily difference between the surface level reading and the June 13 th reading for each one-year June 13 to June 13 period and is shown in Figure 3. This was done for each of the one-year June 13 to June 13 periods from June 13, 2004 to June 13, 2014. The data for 2008-2009 were adjusted to account for the data spiked recorded by the ENRAF gauge. The red line is the period from June 13, 2013 to June 13, 2014. The difference between the June 13, 2013 and June 13, 2014 surface level reading was 0.0 m (0.0 inches). In comparison, the annual change for most of the other periods was in the -7.6 x 10-4 m to -2.8 x 10-3 m (-0.03 to -0.11 in.) range. The -5.3 x 10-3 m (-0.21 in.) change for the 2007-2008 data was due to instrument problems. 4

Fig. 3. Tank T-203 Annual Surface Level Change 2004 to 2014. In summary, closing the breather filter valve in tank T-203 for a year resulted in a net surface level change of 0.0 m (0.0 in.) and supported the conclusion that the decreasing liquid level in the tank was due to evaporation. Tank 241-T-204 The tank T-204 breather valve was also shut in June 2013, and, similar to tank T-203, the level data was collected and analyzed over the course of the ensuing 12 months. The 10-year period of level data for tank T-204 is shown in Figure 4. It was very erratic due to instrument problems, so the spikes in Figure 4 data were not actual level changes. This made it more difficult to analyze and interpret the data. 5

Fig. 4. Tank T-204 Level Data 2004 to 2014. Once again, a comparison chart was prepared to display the daily differences in level data compared to the June 13 starting value for a one year period. This chart is shown in Figure 5, and the red line is the period between June 13, 2013 and June 13, 2014. The change in surface level for this period was about -1.3 x 10-3 m (-0.05 in.) and less than the change for all other periods with stable data. The change for the majority of the other relatively stable June to June annual periods was approximately -1.3 x 10-3 m to -5.8 x 10-3 m (-0.05 to -0.23 in.). 6

Fig. 5. Tank T-204 Annual Surface Level Change. In summary, closing the breather filter valve in tank T-204 for one year resulted in a significantly smaller annual level change compared to years with the valve open, but because of the erratic data, no other conclusions could be drawn. It still supports the claim that the evaporation estimates are reasonable. CONCLUSIONS Closing the breather filter inlet valves proved to be a useful way to confirm that evaporation estimates were reasonable for the 6.1 m (20 ft.) diameter tanks evaluated. A better understanding of the contribution of evaporation to level change in the tanks will be useful in evaluations of other tanks with decreasing level trends. REFERENCES 1. J. S. SCHOFIELD and A. J. Feero, RPP-RPT-57960, Results of June 2013 to June 2014 Breather Filter Inlet Valve Closure Test for Tanks 241-T-203 and 241-T-204, Revision 0, Washington River Protection Solutions LLC, Richland, Washington (2014). 2. J. S. SCHOFIELD, RPP-RPT-55264, Evaluation of Tanks 241-T-203 and 241-T-204 Level Data and In-Tank Video Inspections, Revision 0, Washington River Protection Solutions LLC, Richland, Washington (2013). 3. TANK AND PIPELINE INTEGRITY, PM-13-004, Closing Breather Filter Inlet Valves on 241-T-203 and 241-T-204, Washington River Protection Solutions LLC, Richland, Washington (2013). 4. H-2-69748, Air Filter for Waste Tank Atmospheric Breathing, Sheet 1, Revision 4, Washington River Protection Solutions LLC, Richland, Washington (1981). 7

5. L. J. KRIPPS, HNF-SD-WM-TSR-006, Tank Farms Technical Safety Requirements, Revision 7-P, Washington River Protection Solutions LLC, Richland, Washington (2013). 6. TF-AOP-005, Response to Unexpected Tank Temperature, Level or Flammable Gas Increase, Revision E-0, Washington River Protection Solutions LLC, Richland, Washington (2013). 7. R. J. YARBROUGH, RPP-5926, Steady-State Flammable Gas Release Rate Calculation and Lower Flammability Level Evaluation for Hanford Tank Waste, Revision 13, Washington River Protection Solutions LLC, Richland, Washington (2013). 8