General Specifications

Similar documents
General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

General Specifications

EDR-N8A CS Intelligent Absolute Pressure Transmitter STANDARD SPECIFICATIONS. Accuracy Material Code: Standard,316L Range Accuracy Code

C S. Sanitary Differential Pressure Transmitter with Diaphragm Displacement Device CS Range Code. Accuracy. Note 1)

General Specifications

C S. Differential Pressure Transmitter CS Range Code. Accuracy

ST3000 Series 900 Smart Transmitter Differential Pressure Transmitters

JUMO dtrans p20 DELTA

Three Way Control Valves

Rosemount 1810 Flush Mount Pressure Transmitter ROSEMOUNT 1810 FEATURES:

UNIK 5800/5900. Flameproof/Explosion-Proof Pressure Sensing Platform. GE Measurement & Control. High Quality. Features. Bespoke as Standard.

SATRON VDt Differential Pressure Transmitter

General Specifications

Smart Pressure Transmitter

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

Monocrystalline silicon smart differential pressure transmitter. High stability, Diaphragm sealed. Benefits. Application

Smart Pressure Transmitter

UNIK Pressure Sensing Platform. GE Sensing & Inspection Technologies. Features

Three Way Control Valves

Differential pressure transmitter PASCAL Ci4 Delta P

SPANS AND RANGES. Lower Range Limits 150 in. H 2 O ( 38 kpa) 800 in. H 2 O ( 200 kpa)

Smart Pressure Transmitter

CDT1000 series QUICK FLOW. Digital Flowmeter for Air Conditioning Application OUTLINE FEATURES STANDARD SPECIFICATION

SATRON VT Pressure Transmitter

DL 01. Battery Powered Precision Digital Gauge for Leak Testing. Stainless Steel Sensor. class 0.05

User s Manual. Model MLD Loop Powered Process Indicator IM 61A01A01-01E-A IM 61A01A01-01E-A. 4th Edition

Differential pressure transmitter PASCAL Ci4 Delta P

Differential pressure transmitter PASCAL Ci4 Delta P

Pressure transmitter PASCAL CV4

2-Color Display Digital Pressure Switch

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

User s Manual. Model MLA & MLD Loop Powered Process Indicators. Model MLD (Digital) Model MLA (Analog)

General Specifications

General Specifications

Smart Pressure Transmitter

General Specifications

General Specifications

Model Y/13FA, Y/13FEA and Y/15FA Pneumatic Flange Mounting Differential Pressure Transmitters

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch 25 M ISE30 01 ZSE M. How to Order. For positive pressure

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

압력트랜스미터 Model ADP9000 Series

2-colour display. Digital Pressure Switch. Stainless diaphragm Oil-free (Single-layer diaphragm structure) IP65 compliant

SATRON VVFe Pressure Transmitter

2010TC for Differential Pressure, Pressure and Temperature (Mass Flow)

Rosemount 3152N Nuclear Qualified Pressure Transmitter

Piezoresistive single crystal silicon pressure transmitter

INTERPLANT STANDARD - STEEL INDUSTRY. Specification for Smart Pressure & Differential Pressure Transmitter

DM01. Battery Powered Precision Digital Gauge. Stainless Steel Sensor. class 0.05

2SGT. Electronic Pressure Instrument. Three Separate Functions in a Single Loop-Powered Device

2600T Series Pressure Transmitter

General Specifications

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Model 266HSH Gauge pressure transmitter low power consumption (1 to 5 V DC and HART)

Rosemount 3152K Nuclear Qualified Pressure Transmitter

SITRANS P measuring instruments for pressure

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

M3500 Industrial Pressure Transmitter

Eccentric Rotary Control Valve (For size 1 to 4 inches)

Smart Valve Positioner 700 Series with HART Communication Protocol

2-Color Display High-Precision Digital Pressure Switch

ST3000 Ace Smart Transmitter Sanitary Differential Pressure / Pressure Transmitters

Operating Instructions Vaccon VDS-1000 Solid State Combination Vacuum Switch/Sensor w/ Digital Display

Set value (Threshold value) Bottom value. *2 Further reduced by approx. 60% in power-saving mode (For 20 series)

Smart Valve Positioner 700 Series with HART Communication Protocol

SATRON VTe pressure transmitter

ABB Instrumentation. 50T Series Transmitters Model 54G/A gauge/absolute pressure transmitter for sanitary use. Specification sheet

FIELD DEVICES CONTROLLERS

Product presentation SITRANS P310

PitoMaster FPD550 Compact averaging pitot flowmeter. Economical flow metering solutions for gases, liquids and steam

Series 10-ZSE40A(F)/10-ISE40A

AMETEK Model PPC Series Electronic Pressure Calibrator

User's Manual Models SE100MJ/NJ and SE200MJ/NJ Integral Type Magnetic Flowmeter

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

Eccentric Rotary Control Valve (For size 6 to 12 inches)

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Series 60. New Smart Positioner. Compact design Convenient & powerful function Enhanced reliability

General Specifications

Pressure transmitter JUMO dtrans p02

Smart Displacement type Level Transmitter

SITRANS P measuring instruments for pressure

Series ZSE30/ISE30. High Precision, 2-color Display Digital Pressure Switch. With One-touch fittings are newly introduced. PSE

Portable pressure calibrator, Wally Box III Model CPH7600

3-step setting. 2-Color Display High-Precision Digital Pressure Switch. Series ZSE30A(F)/ISE30A. Added vacuum range.

Temperature Indicating Controller

Smart Electromagnetic Flowmeter Detector for Sanitary use

IGP10, IGP20 Intelligent Gauge Pressure Transmitters IAP10 Intelligent Absolute Pressure Transmitter

Differential Pressure Gauges (701P Series)

CV3000 Series Low-Noise Cage type Control Valve Model ACN

Remote-sealed type of Differential Pressure Transmitters

Electric Top-Guided Single-Seated Control Valves

Safir-M digital. Features. LCD indicator and controls. Industries. Applications

Level Measurement. Continuous level measurement - Capacitance transmitters SITRANS LC500. 5/282 Siemens FI Overview.

AP ATEX AIRPOWER POSITIONERS AP2000 FEATURES AP1000 & AP1200 FEATURES OPTIONS OPTIONS

Transcription:

General Specifications Model EJB430 Gauge Pressure Transmitter GS 01C23E01-00E [Style: S2] The model EJB430 Gauge Pressure Transmitter can be used to measure liquid, gas, or steam pressure. It outputs a 4 to 20 m DC signal corresponding to the measured gauge pressure. The model EJB430 also features remote setup and monitoring through communications with the model BT200/100 BRIN TERMINL, CENTUM CS/XL system etc. STNDRD SPECIFICTIONS Measurement s: Capsule B Measurement Span 0.06 to 3 MPa {0.6 to 30 kgf/cm 2 } Measurement -0.1 to 3 MPa {-1 to 30 kgf/cm 2 } 0.46 to 14 MPa -0.1 to 14 MPa {4.6 to 140 kgf/cm 2 } {-1 to 140 kgf/cm 2 } Maimum Overpressure 4.5 MPa {45 kgf/cm 2 } 21 MPa {210 kgf/cm 2 } T01E.EPS Output Signal: 4 to 20 m DC, 2-wire system with digital communication Failure larm: Output status at CPU failure and hardware error; Up-scale: 110%, 21.6 m DC or more (standard) Down-scale: -5%, 3.2 m DC Conditions of Communication Line: Power supply voltage; 16.4 to 42 V DC Load resistance; See Figure 1. Communication distance; 2 km, when CEV polyethylene-insulated PVC-sheathed control cables are used. Note: Communication distance varies depends on kind of cable. Load capacitance; 0.22 F or less. Load inductance; 3.3 mh or less. Spacing from power line; 15 cm or more. Input impedance of receiver connected receiving resistance; 10 k or more at 2.4 khz ccuracy: See Table 1 and Figure 3 Stability*: 0.1 % for 6 months (* 2.) * ZERO ERROR at 23 2 C under atmospheric pressure. is the highest value among the absolute values of the lower range value (LRV) and higher range value (HRV), and the span value in a calibration range. mbient Temperature Limits: -40 to 85 C (-40 to 185 F) (general-use type) -30 to 80 C (-22 to 176 F) (with integral indicator) -20 to 60 C (-4 to 140 F) (JIS flameproof type) mbient Temperature Effect: See Table 1. Process Temperature Limits: -40 to 120 C (-40 to 248 F) (general use type) -20 to 120 C (-4 to 248 F) (JIS flameproof type) mbient Humidity Limits: 5 to 100 % R.H.(at 40 C) Working Pressure Limits: 2.7 kpa abs{20 mmhg abs} to maimum working pressure (See Model and Suffi Codes ). For atmospheric pressure or below, see Figure 2. Power Supply Effect: 0.005 %/V (21.6 to 32 V DC, 350 ) Mounting: 2-inch pipe mounting. Mounting Position Effect: 390 Pa {40 mmh 2 O}/90. No effect for displacement parallel to diaphragm. These errors can be corrected by the zero adjustment. Degrees of Protection: IP67, NEM4, JIS C0920 immersion proof Eplosion-protected Construction: See Optional Specification. Electrical Connection: See Model and Suffi Codes. Process Connections: See Model and Suffi Codes. Wetted Parts Material: Diaphragm, cover flange, process connector, and vent plug; See Model and Suffi Codes. Capsule gaskets; Teflon-coated JIS SUS316L. Process connector gasket; PTFE (Teflon) Flange Bolts and Nuts Material: See Model and Suffi Codes. mplifier Housing: Cast aluminum alloy. Yokogawa Electric Corporation 2-9-32 Nakacho, Musashino-shi, Tokyo, 180-8750 Japan Phone: 81-422-52-5690 Fa.: 81-422-52-2018 GS 01C23E01-00E Copyright ug. 1995 10th Edition pr. 2006

Damping Time Constant: (Sum of time constants for amplifier assembly and capsule assembly) mplifier assembly time constant; Can be set in 9 increments from 0.2 to 64 sec. Capsule assembly time constant; Integral Indicator: LCD digital indicator (optional) < Settings When Shipped > Capsule B Time Constant (sec) ppro. 0.2 ppro. 0.2 T02E.EPS Painting: Polyurethane resin baked finish. For case; frosty white (Munsell 2.5Y8.4/1.2) For cover; deep sea moss green (Munsell 0.6GY3.1/2.0) Eternal Zero djustment: Continuously djustable Resolution; 0.01 % of span Zero djustment Limits: Zero can be fully elevated or suppressed as long as low and high range values are within the measurement range limits of the capsule. Tag Plate: JIS SUS304. Weight: 5.1 kg (11.2 lb) without mounting bracket and process connector. 2 Tag Number Output Mode Display Mode Operation Mode Damping Time Constant *2 s specified in order *1 Linear unless otherwise specified in order Linear unless otherwise specified in order Normal unless otherwise specified in order 2 sec. Calibration Lower Value Calibration Higher Value Calibration Units s specified in order s specified in order Selected from mmh 2 O, mmq, mmwg, mmhg, Pa, hpa, kpa, MPa, mbar, bar, gf/cm 2, kgf/cm 2, inh 2 O, inhg, fth 2 O, or psi. (Only one unit can be specified) *1: Up to 16 alphanumeric characters (including - and ) will be entrered in the amplifier memory. T03E.EPS 600 Eternal load resistance 250 R= E-10.5 0.0236 Communication applicable range 100{750} Working pressure KPa abs {mmhg abs} 10{75} pplicable range tmospheric pressure R ( ) 2.7{20} 10.5 16.4 24.7 42 Power supply voltage E (V DC) Figure 1. Relationship Between Power Supply Voltage and Eternal Load Resistance F01E.EPS 1{7.5} -40 0 40 80 120 Process temperature ( C) Figure 2. Working Pressure and Process Temperature F02E.EPS 0.2 ccuracy 0.1 % 0 capsule 0 0.1{1} 0.3{3} Value of '' 3 MPa{30 kgf/cm 2 } B capsule 0 0.46{4.6} 1.4{14} 14 MPa{140 kgf/cm 2 } () Figure 3. ccuracy F03E.EPS ll Rights Reserved. Copyright 1995, Yokogawa Electric Corporation GS 01C23E01-00E Jan. 05, 2005-00

3 Table 1. ccuracy and mbient Temperature Effect (s Percent of '') *1 Capsule ccuracy mbient temperature effect Zero shift Total shift *2 (0.2+0.2, B 0.1 % For (0.05+0.05 ) % For < ) % / 50 C 0.6 % / 50 C change For (0.25+0.35 ) % / 50 C For < T04E.EPS *1: '' is the highest value among the absolute values of the lower range value (LRV) and higher range value (HRV), and the span value in a calibration range. Percent of span = Percent of span *2: Combined zero and span shift Table 2. Value of '' Capsule B 0.3 MPa {3 kgf/cm 2 } 1.4 MPa {14 kgf/cm 2 } T05E.EPS ll Rights Reserved. Copyright 1995, Yokogawa Electric Corporation GS 01C23E01-00E pr. 01, 2006-00

4 MODEL ND SUFFIX CODES Model Suffi Codes EJB430.................................. Output Signal -D................................ Measurement span............................. (capsule) B............................. Wetted parts material *6 S............................ Process connection 0........................... 1........................... 2........................... 3........................... 4........................... 5........................... Bolts and nuts material Installation Electrical connection Integral indicator Mounting bracket Optional codes......................... B......................... -0...................... -1...................... -2...................... -3...................... -4...................... -5...................... 0.................... 1.................... 2.................... 5.................... 6.................... 7.................... D.................. N................................... B................. C................. D................. N................. Description Gauge pressure transmitter 4 to 20 m DC with digital communication (BRIN protocol) 0.06 to 3 MPa{0.6 to 30 kgf/cm 2 } 0.46 to 14 MPa{4.6 to 140 kgf/cm 2 } [Body] [Capsule] [Vent plug] JIS SCS14 *2 JIS SUS316L *1 JIS SUS316 without process connector (Rc1/4 female on the cover flanges) with Rc1/4 female process connector with Rc1/2 female process connector with 1/4 NPT female process connector with 1/2 NPT female process connector without process connector (1/4 NPT female on the cover flanges) [Maimum working pressure] ( capsule) (B capsule) JIS SCM435 3 MPa {30 kgf/cm 2 } 14 MPa {140 kgf/cm 2 } JIS SUS630 3 MPa {30 kgf/cm 2 } 14 MPa {140 kgf/cm 2 } Vertical impulse piping type, left side terminal bo, right side high pressure, process connector upside *3 Vertical impulse piping type, left side terminal bo, right side high pressure, process connector downside *3 Vertical impulse piping type, right side terminal bo, right side high pressure, process connector upside *3 Vertical impulse piping type, right side terminal bo, right side high pressure, process connector downside *3 Horizontal impulse piping type, left side terminal bo, right side high pressure *4 Horizontal impulse piping type, right side terminal bo, right side high pressure *4 G1/2 female G3/4 female 1/2 NPT female G1/2 female, with eternal indicator connection and a blind plug G3/4 female, with eternal indicator connection and a blind plug 1/2 NPT female, with eternal indicator connection and a blind plug Digital indicator *5 (None) JIS SECC 2-inch pipe mounting (flat type) JIS SUS304 2-inch pipe mounting (flat type) JIS SECC 2-inch pipe mounting (L type) JIS SUS304 2-inch pipe mounting (L type) (None) / Optional specification The marks indicate the most typical selection for each specification. Eample: EJB430-DS5-02NC/ T06E.EPS *1: Diaphragm material is Hastelloy C-276 or STM N10276. Indicated is other capsule wetted parts material. *2: Indicates cover flange and process connector material. *3: If necessary, specify Mounting bracket code C or D. *4: If necessary, specify Mounting bracket code or B. *5: Not available for Installation code -4 and -5. *6: Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam (150 ºC [302 ºF] or above). Contact Yokogawa for detailed information of the wetted parts material. ll Rights Reserved. Copyright 1995, Yokogawa Electric Corporation GS 01C23E01-00E pr. 01, 2006-00

5 OPTIONL SPECIFICTIONS Item Description Code TIIS Flameproof pproval, E do IIC T4X *10 *12 Eplosionproof type Certificate: TC13814 (Without integral indicator) JF3 TC13815 (With integral indicator) Electrical connection : G1/2 female 1 pc. G11 ttached flameproof packing pplicable cable O. D. : 8 to 12 mm 2 pcs. G12 adapter *1 Electrical connection : G3/4 female 1 pc. G21 pplicable cable O. D. : 10 to 16 mm 2 pcs. G22 Painting Color change Coating change mplifier cover only Epoy resin-baked coating *13 P X1 Lightning protector Transmitter power supply voltage : 10.8 to 32 V DC llowable current : Ma. 6000 (1 40 s), Repeating 1000 (1 40 s) 100 times Degrease cleansing treatment K1 Oil-prohibited use Degrease cleansing treatment and with fluorinated oilfilled capsule. Operating temperature -20 to 80 C K2 Oil-prohibited use Degrease cleansing treatment and dehydrating treatment K5 with dehydrating treatment Degrease cleansing treatment and dehydrating treatment with fluorinated oilfilled capsule. Operating temperature -20 to 80 C K6 P calibration (psi unit) D1 Calibration units *2 bar calibration (bar unit) ( See Table 3. ) D3 M calibration (kgf/cm 2 unit) D4 Sealing treatment to JIS Sealant(liquid silicone rubber) is coated on JIS SUS630 cover flange mounting nuts against SUS630 nuts stress corrosion cracking. Y Long vent *3 Left side high pressure Total length: 119 mm (standard: 34 mm); Total length when combining with Optional code K1, K2, K5, and K6: 130 mm. Material: SUS316. Process connection : Left side high pressure (standard, right side high pressure) U L Failure alarm down-scale *4 Output status at CPU failure and hardware error. C1 Cover flange *5 M01 Mill Certificate Cover flange, Process connector *6 M11 Pressure test / Test Pressure : 3 MPa{30 kgf/cm 2 } *7 Nitrogen(N 2 ) Gas *9 T03 Leak test Certificate *11 Test Pressure : 14 MPa{140 kgf/cm 2 } *8 Retention time: 10 minutes T02 *1: If cable wiring is to be used to a TIIS flameproof type transmitter, do not fail to add the YOKOGW-assured flameproof packing adapter. *2: The unit of MWP (Ma. working pressure) on the name plate of a housing is the same unit as specified by Optional code D1, D3, and D4. *3 pplicable for vertical impulse piping type (Installation code 0, 1, 2, or 3). *4: The hardware error indicates faulty amplifier or capsule. *5: pplicable for Process connections code 0 and 5. *6: pplicable for Process connections code 1, 2, 3, and 4. *7: pplicable for Capsule code. *8: pplicable for Capsule code B. *9: Pure nitrogen gas is used for oil-prohibited use (Optional code K1, K2, K5, and K6). *10: In case the ambient temperature eceeds 50 C, use heat-resistant cables with maimum allowable temperature of 75 C or above. *11: The unit on the certificate is always MPa regardless of selection of option code D1, D3, or D4. *12: TIIS (The Technology Institution of Industrial Safety) Certification is a new notation for the eplosionproof approval in Japan instead of JIS. *13: Not applicable for color change option. Table 3. Calibration Units Measurement Optional Code Span and D1 ( psi Unit ) D3 ( bar Unit ) D4 ( kgf/cm 2 Unit ) B Span Span 8 to 430 psi 66 to 2000 psi 0.6 to 30 bar 4.6 to 140 bar 0.6 to 30 kgf/cm 2 4.6 to 140 kgf/cm 2-15 to 430 psi -15 to 2000 psi -1 to 30 bar -1 to 140 bar -1 to 30 kgf/cm 2-1 to 140 kgf/cm 2 T08E.EPS T07E.EPS ll Rights Reserved. Copyright 1995, Yokogawa Electric Corporation GS 01C23E01-00E pr. 01, 2006-00

6 DIMENSIONS Vertical Impulse Piping Type (Left side Terminal Bo) Unit : mm (appro.inch) Shrouding bolts (Only for TIIS Flameproof type) 193 (7.60) 70 (2.76) 125 (4.92) 27 (1.06) 161 (6.34) 97 (3.82) 104 (4.09) 161 (6.34) 97(3.82) 104 (4.09) 79 (3.11) 68 (2.68) 111 (4.37) 102 (4.02) 53 (2.09) 62 (2.44) 46 (1.81) Open to atmosphere (Ø 9mm) Process connector upside (INSTLLTION CODE '0') Process connector downside (INSTLLTION CODE '1') F04E.EPS Horizontal Impulse Piping Type (Left side Terminal Bo - INSTLLTION CODE '4' - ) Shrouding bolts (Only for TIIS Flameproof type) 193 (7.60) 70 125 (2.76) (4.92) 86 94 (3.39) (3.70) 111 (4.37) 68 (2.68) 161 (6.34) 200 (7.87) 27 (1.06) 72 (2.83) 124 (4.88) 47 (1.85) Open to atmosphere (Ø 5mm) F05E.EPS ll Rights Reserved. Copyright 1995, Yokogawa Electric Corporation GS 01C23E01-00E pr. 01, 2006-00

7 Terminal Configuration CHECH METER Connection hook Jumper Terminal Wiring + SUPPLY /BT METER + Power supply and output terminal Eternal indicator(ammeter) terminal Ground terminal Note: When using an eternal indicator, the internal resistance must be 10 or less. BRIN TERMINL Connection hook < Ordering Information > Specify the following when ordering 1. Model, suffi codes, and optional codes 2. Calibration range and units: 1) Calibration range can be specified with range value specifications up to 5 digits (ecluding any decimal point) for low or high range limits within the range of -32000 to 32000. 2) Specify only one unit from the table, Settings when shipped. 3. Select linear or square root for output mode and display mode. Note: If not specified, the instrument is shipped set for linear mode. 4. Select normal or reverse for operation mode Note: If not specified, the instrument is shipped in normal operation mode. 5. Display scale and units (for transmitters equipped with integral indicator only) Specify either 0 to 100 % or engineering unit scale and and Unit for engineering units scale: Scale range can be specified with range limit specifications up to 5 digits (ecluding any decimal point) for low or high range limits within the range of -19999 to 19999. The range with decimals is available to the third decimal place. 6. Tag Number (if required) < Related Instruments > Power Distributor: Refer to GS 01B04T01-02E or GS 01B04T02-02E BRIN TERMINL: Refer to GS 01C0011-00E F06E.EPS < Reference > 1. JIS SUS316L stainless steel; Equivalent to ISI 316L. 2. JIS SUS316 stainless steel; Equivalent to ISI 316. 3. JIS SUS304 stainless steel; Equivalent to ISI 304. 4. JIS SECC Carbon steel. 5. Teflon; Trademark of E.I. DuPont de Nemours & Company (US) for polytetrafluoreoethylene. 6. JIS SUS630 stainless steel; Equivalent to STM 630. 7. Hastelloy; Trademark of Haynes International Inc. 8. JIS SCS14 stainless steel; Equivalent to JIS SUS316 cast stainless steel or STM CF-8M. 9. Other company names and product names used in this material are registered trademarks or trademarks of their respective owners. ll Rights Reserved. Copyright 1995, Yokogawa Electric Corporation Subject to change without notice. GS 01C23E01-00E pr. 01, 2006-00