THE INTELLIGENT MOTION SENSOR TRACKING LIGHT

Similar documents
ASSEMBLY AND INSTALLATION INSTRUCTIONS

ASSEMBLY & FITTING INSTRUCTIONS P-LUX3 LED TRI-SENSOR LANTERN

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

PROFESSIONAL 270 o PIR MOTION DETECTOR

Specification Sheet for 2D LED Light

Installation Manual GT500 GT500R RAB

Compact Security FloodLight

DUALBRITE Motion Sensing Coach Light

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Motion and Light Sensor Kit LHBAS51

INSTALLATION & MAINTENANCE MANUAL HBL

Installation Instructions

MOTION-ACTIVATED WALL LANTERN

PMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH

Solar Road Stud. Korea TES Ltd.

CAM-PTZ-AUT Tracking Module for PTZ Camera Installation & User Manual

Installation Instructions & Users Manual

Sieve Shaker 200mm/300mm - 8/12 inch SV003

Installation Instructions

25W LED Cross Bezel Bulkhead Light

ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

Installation Instructions

2x 10W LED Slimline Floodlight Twin Flood

X117E. X117E Contact-Less Valve Position Transmitter INSTALLATION / OPERATION / MAINTENANCE MODEL. X117E Contact-Less Valve Position Transmitter

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

10W LED Die Cast Small Rectangle Bulkhead Light

GARAGE DOOR OPENER OWNER S MANUAL S3/S4

WP37 & HT37 User Manual

NON MAINTAINED TWIN SPOTLIGHT WALL MOUNT LED EMERGENCY LIGHT

6.5 Multi Function C5 LED Pre-Lighted Tree Pre-Lighted Tree 96842

O U T B A C K P R O O F G E A R 12V / 24V (MANUAL) O U T B A C K P R O O F G E A R

Informer Compact Series

Roll Up Door Operator

Motion Sensing Coach Light

Security Lighting INSTRUCTION MANUAL 16W, 28W, 36W & 50W PIR Security LED Floodlight

18W Low Energy. instructions. Instructions

Electrical Safety. Electrical Safety Webinar. Electrical. Printing Industries Alliance Printing Industries Alliance 1

Wireless Tire Pressure and Temperature Monitoring System Instruction Manual Model #: TM-507 SCE 507 Commercial Cap Sensors with Monochrome Display

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

User Manual Solar Charge Controller 3KW

ZN-502 A/S/AS USER MANUAL

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

Sliding Gate Operator User's Manual

Owner's Manual. Remote Security and Convenience System INS0866 8/98

User Manual. Solar Charge Controller 3KW

Uninterruptible Power System

Idle Timer Controller - A-ITC620-A Chevrolet Express/GMC Savana

ASSEMBLY AND INSTALLATION INSTRUCTIONS

MAINTAINED LED EMERGENCY CEILING MOUNT SPOTLIGHT

AUTOMATIC CONTROL ROLLING DOOR OPENER

GARAGE DOOR OPERATOR USER S MANUAL

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Model APS-20B Owner's Manual

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Installation Example and Guide

Mightylite Elite 16W LED Wall Light with PIR

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

INSTALLATION INSTRUCTIONS For Light*Waves Flex II Kit with 300-Watt remote transformer

Warning! Before continuing further, please ensure that you have NOT mounted the propellers on the MultiRotor.

Button 1 Button 2. Button 3 Button 4. Programmed Remote Transmitter. Button Function Condition

Model PRO-9675FT4 Owner's Manual

Uninterruptible Power System

CCTV Rack Mount Power Supplies

CCTV Rack Mount Power Supplies

Uninterruptible Power System

Color Changing Pool Lamp

IMPROVED LIGHTING CONTROLS

Sliding Gate Operator User's Manual

SDOMEO51MV USER MANUAL. Portable Rugged PTZ Cameras

SSX-180ST. SolarMaxx 180 Illuminator Service Manual

Installation Guide Rollerdor RD55 Econ Roller Garage Door

Model PRO-9775T Owner's Manual 4 Button Remote Start Security System With Plug-In Shock Sensor & Starter Disable

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

SOLARZEN PRODUCT. Rechargeable LED Work Light ENJOY THE WORLD OF NEW LIGHT WITH SOLARZEN MODEL : SWL-150RU

PERSA 400 USER S AND INSTALLER S MANUAL V1.0 REV. 10/2016

GLM SERIES CONTROL Users Manual Rev:

CONSTRUCTION Aerodynamic aesthetical design optimized for LED characteristics. Modular design for easily installation and maintenance.

8W Explosion Proof LED Exit Sign - C1D2 - Low Voltage - End, Ceiling, Back Mount - IP54

Compact Sine Inverter

Residential SolarEdge StorEdge

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

INSTALLATION INSTRUCTION MANUAL

2-Way Dimmer (1 Gang)

BARRY BARRIER GATE AUTOMATION

XP800i POWER INVERTER OWNER S MANUAL

ELECTRICAL. 60 Minutes

Fiat - Argentina - Wheel Aligner / Headlamp Aimer #16435

Idle Timer Controller - ITC515-A Ford Transit Contact InterMotive for additional vehicle applications

LED CANOPY with j-box

DKC400Y AC Sliding Gate Installation Manual. Sliding Gate Opener. Model: DKC400Y. Installation Manual WARNING

58kHz AM Deactivator DB104 Instruction Manual V1.0

PV Generation System. Solar Charge Controller SPECIFICATION

IR125 & IR300 Infra-red Lamps

Kelly HPM High Power Full Bridge Permanent Magnet DC Motor Controller User s Manual

FL 1000 XT C DMX. User manual

Compact 150 Watt Motion Sensing Halogen

Installing and Setting Up Your Ring Floodlight Cam

Transcription:

THE INTELLIGENT MOTION SENSOR TRACKING LIGHT INSTALLATION INSTRUCTIONS Read all instructions before proceeding with the installation OVERVIEW OF AEC-9336CU Lamp Cover Front housing Lamp 150W Antenna Video Camera Sensor Dip Switch LED indicator INSTALLING THE BULB Unscrew the lamp cover of the luminaire and install a 150W J-type lamp. Re-fit the lamp cover and tighten the screws. IMPORTANT: THE INTALLATION OF THIS FITTING MUST BE DONE BY A QUALIFIED ELECTRICIAN. This fitting must be earthed. Do not mount the luminaire against inflammable surfaces. The motion detector will not operate correctly if it is installed: ( Ⅰ ) Near the outlet of a central heating boiler ( Ⅱ ) Near air conditioning plant ( Ⅲ ) Pointing directly at moving vehicles ( Ⅳ) Within sight of reflection from moving water ( Ⅴ ) Where other lamps could shine onto the detector WARNING!!! BEFORE ATTEMPTING ANY INSTALLATION OR MAINTENANCE, ENSURE THAT THE ELECTRICAL SUPPLY IS SWITCHED OFF AND THE CIRCUIT FUSES REMOVED OR THE CIRCUIT BREAKER IS IN THE OFF POSITION. The maximum rating of this luminaire is 150 Watts. Check that the total load of the circuit. Including this luminaire. Does not exceed the rating of the circuit cable. NOTE: This highly responsive unit may occasionally activate due to rapid environmental changes. Allow for approximately 30 seconds warm-up time before the sensor resumes normal activity.

MOUNTING THE FITTING To ensure correct operation of the sensor, mount the luminaire that traffic passes across the detector. TOP VIEW GOOD SENSITIVITY LESS SENSITIVITY SETTING THE LIGHT UP TIME & SENSITIVTY Remove the back mounting box from the fixture by unscrewing the screw at the bottom. Set the Light up time & Sensitivity you preferred 1:Light up time (OFF: 30 seconds/ ON: 60 seconds) 2:Sensitivity (OFF: 5m/ ON: 10m) Re-fit the back mounting box and tighten the screw. INSTALLATION AND WIRING INSTRUCTIONS Installation to a junction box using crossbar mount 1. Attach the crossbar to junction box and fix by screw A. 2. Connect the black wire (live wire) from the AC power cord to the single black wire coming from Sensor Tracking Light using one of the supplied wire nuts. 3. Connect the white wire from the AC power cord to the white wire coming from Sensor Tracking Light using one of the supplied wire nuts. 4. Connect the green/yellow wire from the AC power cord to the green/yellow wire coming from Sensor Tracking Light using one of the supplied wire nuts. 5. Make sure the polarity is correct. 6. Attach the unit to the crossbar and fix by screw B and screw C.

FUNCTION This light is equipped with 3 motion sensors: zone 1 covers 60 degree, zone 2 covers 100 degrees and zone 3 covers 60 degrees. 220 degrees (maximum) in total for 3 zones. ZONE 2 ZONE 1 ZONE 3 TOTAL DETECTION RANGE The light will switch on for 30 /60 seconds and off automatically when heat/ movement is detected. The factory default: the mode is Auto mode for light works at night, camera works all day. To change the mode to nighttime only(auto mode), push the button at the bottom of the housing and the hidden LED indicator will turn off at this mode. The light will be on at 30 /60 seconds when detecting any movement at night. Push-button for programmable functions: - Test mode: light and camera work all day - Auto mode: light works at night, camera works all day Push-button LED indicator Reset function: If the stepper motor of tracking light works abnormal, the hidden LED indicator will flash in red and the light will stop turning automatically. In Test mode, the red LED will flash for 3 times and off for 5 seconds; in Normally mode, the red light will flash in regular pattern. Please simply switch off and on the main power to resume the tracking light. Below are the possible abnormal situations. - External force: the light head is blocked by objects or is blown by strong wind and is unable to turn properly, the hidden LED will flash in red to signal users the abnormal situation. - Stepper motor: when stepper motor is going to be out of its lifetime or is damaged, the hidden LED will flash in red to signal users the abnormal situation. Please switch off and on the main power, the tracking light now may or may not resume its operation. If the stepper motor stops working, AEC-9336C becomes a regular motion sensor security light. Left 70 Right 70 Hidden LED indicator

OPERATION 1. Insert the plug to activate the light, the light is now under Test mode: light works on day and night NOTE: Allow for approximately 30 seconds warm-up time before the sensor resumes normal activity. 2. To test, walk through the sensor s detection area. 3. Movement will activate the sensor and turn the light on, the light will turn the face to the detected zone. 4. After the light is activated, keep out of detection area and the light will switch off automatically after light up time (30/60 seconds). The light will be activated again when detecting any movement. If there is continuing movement in the detection zone, the light will stay on until movement ceases. (after light up time) LAMP REPLACEMENT To isolate the unit, first switch off the unit from the mains power. Allow bulb to cool before attempting to remove it. Unscrew the lamp cover and take the old lamp out and replace with new one, close the lamp cover and tighten the screws. WARNING: This fitting will become hot when in use. Allow bulb to cool before touching. NOTE: THE INTELLIGENT MOTION SENSOR TRACKING LIGHT IS DESIGNED TO ILLUMINATE WHEN THE DETECTION AREA IS ENTERED BY A PERSON AND WILL DETECT MOVING HEAT SOURCE. THERE IS NO GUARANTEE IMPLIED THAT IT WILL PROVIDE TOTAL SECURITY OR PREVENT ILLEGAL ENTRY. SPECIFICATION Detection Method: Passive Infrared Sensor (with continuously detect function) Sensor Range: 10m x 210 (maximum) Camera: Color CMOS image sensor View angle 60 Transmission frequency: ISM 2.4GHz ARIB-T66 Power source: AC 100V 50/60Hz Time adjustment: 30 / 60 seconds. Sensitivity adjustment: 5m / 10m Load Rating: J-Type 150 Watts Max. PSE cable: 5m Waterproof rating: IP55 OperationTemperature:0 ~+50

F. Installing the Driver on your computer Place CD driver into the Computer CD slot and installing. Choice the software you use for your computer. Follow the instructions on the installation screen Click Setup_090817.exe(fig 1) Next(Fig. 2) Next (Fig. 3) Install(Fig. 4) Finish(Fig. 5) Restart windows. If your computer doesn t run the installation program automatically, please click the Start button and choose Run. Then browse your computer to find CD slot and Driver and click Setup. Fig. 1 Fig. 2 Fig. 3 Fig. 4 Fig. 5

G. Installing the driver of 752C Installing the Drive, please refer above Installing the Driver on your computer. Assembly and power on the 9336C. Please refer assembly of 9336C. Please re-install the driver of 752C if appear this software cannot find. Plug 752C into a USB port on your PC and follow the instructions on the installation screen as fig. 6 ~ 11. Fig. 6 Fig. 7 Fig. 8 Fig. 9 Fig. 10 Fig. 11 Set up the 9336C and 752C of ID code: Plug 752C into a USB port on your PC,10 seconds later to click Night Guard as show on the screen. Click the Night Guard(Fig. 12) Setup(Fig. 13)

Device Setup(Fig. 14) Choice channel CH1~ CH4(Fig. 15) Press 9336C of top button and when the video is shown on the screen the setup is completed(fig. 16) then click OK(Fig. 17) Fig. 12 Fig. 13 Fig. 14 Fig. 15 H. Definition of Driver of 752C File:Save mode A:Single file save Fig. 16 Fig. 17

B:Multi files save Preview:Shooting / Recording mode C : Auto recording D:Manual recording - Capture Photo E:Manual recording - Recording video Setup:Channel Column Channel 1:Set up Channel F:It can select Channel 1 4 of Single view or 4 quad view Alarm G / H:Alarm ON / OFF J:When TX detected, one of channel 1 4 will turn to Red background. Signal Intensity Display I:RX and TX of transmission signal.