SANITARY SELF PRIMING PUMP Manual

Similar documents
- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Operating Instructions

SLR / SLR-S/N. Instruction Manual. Walrus America Inc

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 THERMAL INSULATION 301 MECHANICAL SEAL 302 BEARINGS DIMENSIONS and WEIGHT 400 PUMP 400 PACKING 401

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

ATS ENG INC. ATS Engineering Inc. OWNER S MANUAL AH100D

Installation, Operation and Maintenance Manual SCP/SFP SELF PRIMING PUMPS

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

Instruction Manual. SMP-BCA Aseptic Mixproof Valve with PTFE Diaphragm IM70811-EN

This manual presents installation, servicing, troubleshooting, and maintenance for M PUMPS CM MAG-M SERIES Information that may be required regarding

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-40 RX-63 RX-100

2CDX. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

GRUNDFOS INSTRUCTIONS MTC. Installation and operating instructions

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 THERMAL INSULATION DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Vertical Chemical Pumps

VERTICAL MULTI-STAGES CENTRIFUGAL PUMPS

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400

Single Stage Rotary Vane Vacuum Pump Installation and Operation Manual RX-10 RX-21 RX-25

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

- DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX DIMENSION TABLE MATRIX PACKING 403

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

PRA EBAR. RA Pumps Europe S.p.A. CENTRIFUGAL PUMPS CONTENTS. 60Hz. Page - SPECIFICATIONS

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

CM3-6 A-R-G-E-AQQE C-A-A-N

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

maintenance of the winch. All information in this publication is based on the latest production information available at the time of printing.

OVIM/OVIMF. OVIM 60Hz OVIMF 60Hz. A New Vision for Quality Pumps. Light Vertical Multistage Centrifugal Pumps

Three Lobes Roots Blower. Instruction Manual

INSTALLATION, SERVICE AND MAINTENANCE INSTRUCTIONS HYGINOX SH

END SUCTION CENTRIFUGAL PUMPS

VERTICAL MULTI-STAGE CENTRIFUGAL PUMPS

End Suction Centrifugal

3D SERIES. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 GEOMETRIC TOLERANCES 401 PACKING 402

SPECIFY THE RIGHT HOT OIL PUMP FOR YOUR APPLICATION

CM5-6 A-R-A-E-AQQE C-A-A-N

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

Matrix_Techdata_SS_V14

DATA SHEET 6K151CT2, 6K151CT4, 6K201CT2, 6K201CT4, 6K301CT4, 6K401CT4 OPEN IMPELLER CENTRIFUGAL PUMPS. Stainless Steel Models: SPECIFICATIONS FEATURES

INSTALLATION, SERVICE AND, MAINTENANCE INSTRUCTIONS HYGINOX SE PUMP

- CONTENTS SPECIFICATIONS 200 SELECTION CHARTS 201 PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX PERFORMANCE CHART 2CDX

MMD. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

MODEL INFORMATION CANNED MOTOR PUMP TYPE CAM HERMETIC

Technical data 50 & 60 Hz. Vertical centrifugal pumps Series: DPLHS

Eurovacuum Installations and Operating manual EVD Series Vacuum pumps Models: EVD-6 to EVD-90. Double Stage Oil Lubricated Rotary Vane Vacuum Pump

SERIES PC INSTRUCTION AND OPERATION MANUAL

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

HYGIENIC CENTRIFUGAL PUMPS

MMD 4 Poles. EBARA PUMPS EUROPE S.p.A. CENTRIFUGAL PUMPS. Page

END SUCTION CENTRIFUGAL PUMPS

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 GEOMETRIC TOLERANCES 401 PACKING 402

1 Full Year Factory Warranty SIKO PUMP

SÜDMO NEW SP SERIES - HYGIENIC CENTRIFUGAL PUMPS FOR THE FOOD & BEVERAGE INDUSTRY FOOD & BEVERAGE PROCESS SOLUTIONS HYGIENIC CENTRIFUGAL PUMPS

CM5-5 A-R-A-E-AVBE C-A-A-N

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS and WEIGHT 400 PUMP 400 PACKING 401

3" & 4" Cast Iron Self-Priming Centrifugal Pump Instruction Manual

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEAL 303 FITTINGS 304

VADA - V60-J PRODUCT OVERVIEW CONSTRUCTION MOTOR USAGE LIMITATIONS WARRANTY

Page - DIMENSIONS AND WEIGHT 400 PUMP MATRIX PUMP DRAWING MATRIX 5/10/ PUMP TABLE MATRIX 5/10/ PACKING 403

Operation Manual For NDJ-4 Rotary Viscometer MADE IN CHINA

Instruction Manual. SolidC Pump ESE00797-EN Original manual

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Data sheet. Page: 1 / 5. ETL GGSAV11D BKSBIE3 Inline pump. Operating data. Design

Page - CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 QUANTITY FOR MODEL 302 MECHANICAL SEAL 303 BEARINGS 304 FITTINGS 305

- SPECIFICATIONS 200 SELECTION CHART 201 TYPE KEY AND CURVE SPECIFICATIONS 202 PERFORMANCE CURVE DWC PERFORMANCE CURVE DWC

INSTRUCTION MANUAL INDUSTRIAL PERISTALTIC PUMPS MODEL RBT-70

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

our contribution for Sealless Magnetic Coupled Multistage Centrifugal Pumps Type HZM / HZMR / HZMB environmental protection

-SPECIFICATIONS Features & Applications 100 Exploded View 101 Pump & Motor Specifications 102 Selection Chart

Series 2200/2220 Control Valve. Operation and Maintenance SCOPE OF MANUAL MAINTENANCE DESCRIPTION VALVE INSTALLATION

CVM. EBARA PUMPS EUROPE S.p.A. MULTISTAGE CENTRIFUGAL PUMPS

OIL DISPENSING SYSTEM

Starting up hydraulic systems

CME1-4 A-R-I-E-AQQE S-A-D-N

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 CONSTRUCTIONS 301 CONSTRUCTIONS 302 MECHANICAL SEAL 303 COUNTERFLANGE 304

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 BEARINGS 302 MECHANICAL SEALS 303 DIAGRAM AND ELECTRIC CONNECTIONS 304

200 PERFORMANCE RANGE and SELECTION CHART 201 TYPE KEY and CURVES SPECIFICATIONS SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE

Vane pumps, direct controlled Type PV7...A

- CONSTRUCTIONS 300 SECTIONAL VIEW DRAWING 300 SECTIONAL VIEW TABLE 301 MECHANICAL SEAL 302 BEARINGS 303

CM1-2 A-R-A-E-AQQE F-A-A-N

Models XXX XXX

INSTALLATION INSTRUCTIONS FOR

CM25-1 A-R-G-E-AQQE C-A-A-N

INSTALLATION, SERVICE AND, MAINTENANCE INSTRUCTIONS ASPIR

Volute Casing Centrifugal Pumps in In-line Design with Magnetic Drive. Series CNI-M

SÜDMO HYGIENIC CENTRIFUGAL PUMPS FOOD & BEVERAGE PROCESS SOLUTIONS HYGIENIC PUMPS

WMTA6 LN SERIES SEAL-LESS MAG-DRIVE MULTI-STAGE TURBINE PUMPS

CME5-5 A-R-I-E-AQQE S-A-D-N

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

Operating and Maintenance Manual Gas/Diesel Engine Powered Self-Priming Centrifugal Pumps Series

SANITARY/HYGIENIC NON-MOTORIZED

- CONSTRUCTIONS 300 SECTIONAL VIEW 300 MECHANICAL SEAL 301 BEARINGS DIMENSIONS AND WEIGHT 400 PUMP 400 PACKING 401

SANITARY SELF-PRIMING PUMPS CLOSED COUPLED WITH STANDARD MOTOR A - AS SERIES SELF-PRIMING PUMPS. Series A-AS

Transcription:

JONENG VALVES CO.,LIMITED SANITARY SELF PRIMING PUMP Manual

JONENG VALVES CO.,LIMITED Technical principle Qty. Parameter Unit Dynamic viscosity factor μ mpa.s (=cp=centipoise) Viscosity V=μ/ρ With ρ=specific weight (kg/dm3) and V=kinematic viscosity (m m2 /s)=cst=centistoke They are all dynamic viscosity Pressure p (bar) p (bar) different pressure Pm (bar) max. pressure of the outlet Except indication, the pressure in the manual is relative pressure. (NPSH) NPSH(m) In this manual,npsh=npshr (NPSH is needed by the pump.) NPSHr=When the liquid come to the hydrostatic or cavitation,the connection tube should be avoid bend. NPSH=It is used for measure the self priming curve When the speed reduces to 4%, The data will be record accurately. NPSHa=If the pump temperature is up to the running temperature, the pressure will be reduce. Total Self priming pressure is measured.. NPSHa NPSHr=o.5 Training and operation As to the operation and maintenance, the operator should be experienced or trained. Any operation differing from the manual could make damage the operator and equipment. The damages: Fail to start the equipment Failed to maintenance. Electrical, mechanical, chemical dangerous. Chemical released gas will pollute the air. Safety instruction for maintenance, check and demounting Need professional operator to maintain the equipment. The operator should read the manual carefully before testing and demounting even though they are very professional. It is very important to stop the pump according to manual. Please read the working principle in the manual carefully before you use the pump again. Do not allow to make any change on the pump without permission Do not allow to make any change on the pump without asking permission of the manufacturer. Had better to use the spare parts and fitting supplied by the manufacturer for security. We will not be responsible for the accident resulting from that. Do not allow to exceed the max. load of equipment in any circumstances.

JONENG VALVES CO.,LIMITED Guarantee We are not responsible for the damage resulting from the following situations: Operation or maintenance of the equipment is not carried out according to the manual; Repair is not finish by our operator or without our written permission. Change the material of the pump without our written permission. Error installation. 2. Instruction Description CIP return stroke pump is made of AISI316/304.Impeller and pump bonnet are both made by in precision casting technology. CIP return stroke pump is compact, with level inlet and vertical outlet.. They are both sanitary connection. The motor is designed in accordance with IEC standard. IP-55 Protection. Insulation grade: F. Power: 50Hz, 60Hz. Standard voltage of motor: 220-240/360-400/600-690,420-460. You also can choose different kinds motor and voltage. For example: 220V 60Hz.The motor could be made in explosion-proof type. Operation principle: The impeller will be driven by setting. Then the liquid will be pumped from the inlet to outlet in power or pressure. The rotary direction of the pump is irreversible (Rotation direction: Clockwise rotation viewed from motor end). Attention: If it is very noisy when the pump is running in the no sheltered situation, please refer to article 15-8/91 of the regulation No 277 to operate the pump. The operation is similar to 85DBA. When the noise grade is over 85DBA, please adopt special protection. Application General speaking, standard return stroke pump is used for pump the liquid material contained air or gas or the liquid of chemical and pharmaceutical. Main products: Wine, juice, beer, acetone.. Solvent, boiling liquid, sprite Juice, alcohol beverage, oil The pressure curves of each series pump shall be produced under 50HZ/60HZ. Structure: All the spare parts of the pump are all made of stainless steel, which makes the pump in

JONENG VALVES CO.,LIMITED good corrosion-proof and prevent the liquid from pollution. Check to be sure that the pump is made according to sanitary standard. CIP Performance Curve N 1450min Medium: 20oC water Suction Head: 8M Inlet dia: 63.5mm Tolerance: ± 5% Frequency: 50Hz Outlet dia:63.5

JONENG VALVES CO.,LIMITED Technical specifications Technical specifications Model: SLRP-20 Code: Max.flow:15m 3 /h Max.head:24H(M) Max.pressure:3Bar/43PSI Max.operating temp:120 248 Max.rev.:1750min Max.Suction height:8m/22ft Motor type:b35,motor frequency 50HZ/60HZ. Motor power(kw)refer to table below: Power(KW) Voltage Power(KW) Voltage 0.75 4 1.1 210V-230V/50HZ 5.5 360V-400V/50HZ 1.5 360V-400V/50HZ 7.5 630V-690V/50HZ 2.2 420V-460V/60HZ 11 420V-460V/60HZ 3 15 INSTALLATION SIZE

JONENG VALVES CO.,LIMITED Important information Always read the manual before using the pump. Unsafe prastices and other important information are emphasized in this manual. Warnings are emphasized by means of special signs. Warnings indicateds that special procedures must be followed to avoid severe personal injury. the pump must be operated by authorized person. The pump must never be pressurised when the pump is serviced. It is the way to lift pump

Positioning Pipe system Make the pump close tank as possible. If possible, the liquid level should be in horizontal level or lower. The inlet and outlet tube should be in vertical direction, please use suitable pipes to reduce the pressure losses resulting from choke flow. Feasibility Leaving enough space around the pump for checking. Leaving enough space in the front and end of the pump for demounting the pump. If the weight of the pump is over than 30Kg, please leaving enough space for elevating. Put the pump close to the drain place. It is very important to increase the connection device of the pump. (Same as in the running) Outside device The pump should be installed in the sheltered place. Before installation, please consult the supplier first. Inside device Keep the motor in the airy place when you setting the pump. Please start the motor according to the manual of the supplier. The connection parts of the pump should be with adequate protections if the liquid is inflammable or explosive. The explosion-proof motor shall comply with the national or local standard. High temperature If the liquid temperature is too high, the temperature inside and around the pump will be higher. Proper protection measures should be adopted when the temperature is over 70 degree. Warning reminder should be adopted. The pump should be placed in horizontally, strictly and shockproof for preventing dangerous. (The pump should be placed before start) Operation If the pump is not with motor, the buyer/user is responsible for start and install the pump. Motor Please read the local safety regulation of the electrical before start the motor. Ask the professional electrician to connect the motor. Necessary measures should be adopted for preventing connection and wiring error.

Protection to Overloaded motor For the protection of overload motor or short circuit, recommended heat or magnetic relay. According to motor max current to adjust current. Electrically connection manual) Have the pump Electrical connected by authorized person (pay attention to The direction of rotation From the motor behind, the pump is rotating clockwise. Power Chart Motor 220/380 380 Connection U= 3*220 3*380

6. Operation Attention: After install according to Manual Chapter 4 Installation, The pum can be start now. Clean Always read the manual before operate the pump. Always check and clean the pipline and pump before operate the pump. Start Open Globe valve on the inlet/outlet tube. If liquid do not flow into pump, fill with liquid when pump is on. Never start the pump when there is no liquid. When the liquid is in a low level, fill the pump with liquid. Check the pump is safe. Start pump. Check whether the pressure of absolute self-priming is sufficient. control of outlet pressure. When the liquid level in a regular, do not use the globe valve. Throughout the operation, the Globe valve should be in a open condition. 7. Maintenance Maintain the pump carefully. Study the manual carefully Maintenance work need be done by authorized person. We can not be held responsible for incorrect operation Preparation work Work area Provide a clean work area, some parts are placed according to strict requirements. Tool Proper use of specialized tools for maintenance and repire. Disconnect Disconnect the power suppy before maintenance work. Safty If you need to repair the pump, do not start the motor. In accordance with the following procedures: the pump switch in the "off" position. disconnect the pump from the power supply. First, empty the pump. Lubricate the internal parts

External cleaning Make sure the pump exterior is clean. Make sure the pump cover is on when cleaning. It is to protect pump motor. Never cool down pump hot parts with water, it will damage the pump parts. 8.Touble Shooting Problem Reason Motor overload 7,8,12 Inadequate flow 1,2,4,5,6,7,8, No pressure for outlet pipe 2,3,6,16 Flow out and pressure problem 1,2,4,5,6,8 Noise and vibration 2,4,5,6,7,8,9,12,13,14 Pump failure 8,9,12,14 Pump overheating 7,8,9,12 abnormal damage 4,5,7,9,12,14 Rubber seal leak 10,11,15 Reason Solution 1 Rotary Direction error Turn Rotary direction 2 NPSH lack Incream NPSH valve Lower the pump position Lower steam pressure Enlarge suction tube diameter 3 Without liquid Fill in 4 cavitation Increase suction pressure 5 Air flow into pump Checking the suction tube and all connectors 6 Suction tube blocked Checking the suction tube and filter 7 Outlet pressuretoo high Enlarge outlet tube size 8 Liquid viscosity too high Lower the viscosity, eg. By heating up the liquid 9 Liquid temperature too high Cooling the liquid 10 Rubber seal damaged Replace rubber seal 11 O-ring is not suit for specific liquid Replace suitable O-ring 12 Impeller damage Lower the temperature Lower the suction pressure Adjust impeller and rack gap 13 Suction tube tension Release tension of suction tube 14 Impurity in the liquid Include filter in the suction tube 15 Spiral seal tension Adjust according to manual 16 Suction tube valve is close Check and open If the problem continue, please stop using the pump. And contact with manufacturer.

9. Demounting and Assembling Maintenance The demounting and assembling of the pump should be finished by the professional operator. Please read the manual carefully before use. Error demount or assemble could damage the pump. We will not be responsible for the accident or damage not inconformity with the instrument. Preparing Precise parts could not be put on the floor. Clean and check the parts carefully after demounted. Replace all worn and damaged parts. Tool Please use proper tool to demount and assemble carefully. Cleaning Clean the inside and outside of pump before take apart. Do not clean the pump when working. Safety Please do not start the pump if you need to make some adjustment to pump. If the support of the pump is removed, please make sure the motor is stop first. Do not stop the pump without supports. Cut off the power supply before demounting and assembling. Make the pump cool down to the room temperature if the liquid permits. Electrical safety Do not start the motor if you need to make some adjustment to pump. According to the following steps: Make sure the switch is turned off. The power supply is cut off. Do not remove the protection device around the pump when the pump is not work. Demounting Stand the pump to vertical like the drawing in the right. Pump shield Close the valves in the inlet and outlet. Watch out! The liquid will splash when you remove the pump shield and tubes. Loosen the four screws (37) Remove the motor shield with hands. (01) Pump head Loosen the four nuts (09) by wrench and remove them. Remove the pump bonnet (22) with hands, then takes off the O-shaped ring (14). Replace the O-shaped ring if necessary. Impeller and mechanical ring Loosen the nut (21) on the impeller with wrench and remove it. Use plastic rod support the impeller (19). Hit the impeller carefully by hammer till it is possible to remove it. Loosen the mechanical seal rotary ring (17) in the end of the impeller with proper tool and remove it. Take off the O-shaped ring (18). Replace the O-shaped ring if necessary. Remove the mechanical stationary ring (16) in the pump base and O-shaped ring (15). Replace the O-shaped ring if necessary.

Pump base Attention! It is no need to separate the pump base and connection supports in regular practice. Make sure the pump base is stand in vertical. Loosen the four nuts (12) on the connection support (08) by wrench. Then raise the (13) and (08) with hands or rope and remove. And put them in the floor. By a turn of 180 degrees, make the connection support up. Loosen the nut (09) by proper wrench and remove. Now the pump base and connection support could be separated. Drive shaft Attention! It is no need to take apart the drive shaft in regular practice. Loosen the tighten ring (05) and bolt (07) by wrench. Hit the tighten ring (05) with rubber hammer carefully and remove. Then hit the tighten ring (03) by hammer till fall away from the drive shaft. Remove the drive shaft (04) by now. Assembling Stand the pump to vertical like the drawing in the right. Put the tighten ring (03) and (05) on the drive shaft. Then assemble the tighten ring (03) and (05) together by bolt (07) and (06). Do not allow to tighten by the wrench right now. Put the whole drive shaft (03, 04, 05, 06, 07) on the motor shaft, Fix the whole drive shaft on the motor shaft with wrench. Put the connection support (08) on the motor flange. Make hole on the connection support and the hole of the motor flange in a straight line. Then put the pump base (13) on the connection support. Screw the impeller carefully onto the drive shaft. Then adjust the shaft height. Remove the impeller (19), then takes off the pump base (13) and connection support (08). Try not touch the drive shaft right now. So the drive shaft is loose. Screw all bolts on the drive shaft tightly with wrench. Make sure it is tight and drive shaft is perpendicular to impeller. Assemble the support (08) and pump base (13) together. Lift the connection support (08) and pump base (13) onto the motor flange and aim at the bolt hole. Then fit on four bolts (12) and nut (27,26,28). The bolts could be tightened by wrench right now. Fit the rotary ring (7) and O-shaped ring (18) on to the impeller (19). Fit the O-shaped ring (15) and Stationary ring (16) on the pump base (13). The fixed pin on the stationary ring should aim at the fixed pin on the pump base. Screw the impeller (19) onto the drive shaft. Then turn the impeller to see if it is jumping or friction with the pump base. If there is no any abnormal conditions, you can tighten the four bolts that used for connect the connection support and motor totally. Then Fit the O-shaped ring (20) and impeller nut (21) onto the impeller and tighten it with wrench totally. Screw the four bolts (11A) onto the pump base (13) with hands. Then grease the O-shaped ring (14) and fit it onto the pump base. Install the pump bonnet (22) to the pump base. Then install the pipes and fittings of the inlet and outlet. As to the detailed parts drawing, pleaser refers to the decomposition map on the chapter 11.

11. Parts list NO. Name Q TY Material 1 Pump cover 1 304 2 Motor 1 / 3 adapter sleeve (screwed hole) 1 304 4 Drive shaft 1 316L 5 adapter sleeve (hole) 1 304 6 Spiral gasket 6 304 7 outer Hex. Bolt 6 304 8 Connection part 1 304 9 Box nut 6 304 10 Spiral gasket 10 304 11 Double head bolt 6 304 12 Inner Hex. Bolt 4 304 13 Pump base 1 304 14 O-Ring 1 NBR 15 O-Ring 1 NBR 16 Stationary ring 1 / 17 Rotary ring 1 / 18 O-Ring 1 FPM 19 Impeller 1 316L 20 O-Ring 1 NBR 21 Impeller bolt 1 316L 22 Pump head 1 316L 23 Seal gasket 2 EPDM 24 Plain adapter 2 316L 25 nut 2 304 26 nut 4 304 27 Spiral gasket 4 304 28 Flat gasket 4 304 29 Nut 4 304 30 Spiral gasket 4 304 31 Inner Hex. Bolt 4 304 32 foot 2 304 33 Nut 4 304 34 support 4 304 35 Buffer shaft sleeve 4 plastic 36 Flat gasket 4 304 37 Outer Hex. Bolt 4 304