Battery & Energy Meter Quick Guide

Similar documents
Battery & Energy Meter Quick Guide

UPS2000-G-(1 kva-3 kva) Quick Guide. Issue: 05 Date: HUAWEI TECHNOLOGIES CO., LTD.

Goodwe 5048ES with BYD B-BOX (2.5-10) Installation Guide

IES GRID FEED-IN LIMITER

StorEdge Wiring Guide & On Site Checklist - Europe, Australia & South Africa

StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa)

Residential SolarEdge StorEdge

User Manual WatchPower App

StorEdge TM Solution Applications with the StorEdge Interface and LG Chem Batteries Connection and Configuration (Europe, APAC, South Africa)

Introduction of EzManage Application

8 Troubleshooting and Maintenance

PV Master OPERATION MANUAL

An ISO 9001:2008 Registered Company

ITCEMS950 Idle Timer Controller - Engine Monitor Shutdown Isuzu NPR 6.0L Gasoline Engine

SH5K+ Hybrid Inverter Overview & Installation.

BYD Battery-Box LV Installation Guidance

SunBox PVS-12M-DB/PVS-16M-DB PV Array Combiner Box User Manual

L I T H I U M B AT T E R Y

Lithium-Ion Phosphate Battery US2000(Version B) Product Manual

SolarEdge. StorEdge Solution Applications. Connection and Configuration Guide. For North America Version 1.0

Commercial 1000VDC String Inverter XGI Installation and Operation Guide Models: XGI XGI

R5 ACS580-01, ACH580-01

Manual. BlueSolar Grid Inverter 1500 / / / / / 230

B-Box Pro 2.5~10.0 User Manual

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

User Manual. Solar Charge Controller 3KW

BYD Battery-Box LV User Manual Battery-Box L 3.5/7.0/10.5/14.0

B-Box Res 2.5~10.0 User Manual

Lithium-Ion Phosphate Battery Phantom-S Product Manual

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

SolarEdge. StorEdge Solution Applications. Connection and Configuration Guide. For Europe, APAC & South Africa Version 1.1

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

My Reserve 500 Install Guide

MPPT Solar Integrated Inverters (500VA~2500VA) User Manual THE SOLAR TECH CO.,LTD. Solar Integrated Inverter Series 500VA~2500VA 13.

GEatom306KHF-5U Three-phase Grid-Tied Battery Inverter. Version 1.1. Global Mainstream Dynamic Energy Technology Ltd. 1

SNMP dedicated to ORVALDI Solar Infini

Application Engineering

3KW Off-grid Solar Power System LFP Battery

CPS Energy Balancer. Version: 1.0

B-Box Pro 13.8 User Manual

User Manual Solar Charge Controller 3KW

Lithium-Ion Phosphate Battery

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS-Q 1.2 to 5.0 kw

HYBRID 5048E. Hybrid Inverter INSTALLATION AND OPERATION MANUAL. Version 2.0E

SP PRO KACO Managed AC Coupling

LS1024BP/ LS2024BP. Solar Charge Controller USER MANUAL

Custom Power Solar Radian Battery Energy Storage System

Installation Guidance

Application Engineering

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Guide for Primary Injection Testing WL Circuit Breakers. Document No. : 11-C

USER GUIDE incardoc ios

1. INTRODUCTION SYSTEM DESCRIPTION Front Panel CONNECTION AND OPERATION TROUBLESHOOTING...8

BYD Battery-Box HV User Manual Battery-Box H 5.1/6.4/7.7/9.0/10.2/11.5

Lithium-Iron Phosphate Battery US2000B Product Manual

9.1.4 Troubleshooting of Faults in LCD Screen

BYD Battery-Box Pro User Manual Battery-Box Pro 13.8

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Installation Guide B-BOX Pro2.5 ~ 10.0

Inverter / Charger Accessory for Steca Solarix PLI Phase / Parallel Kit. Installation and operating instructions Z01 17.

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Elite Power Solutions Automatic Battery Control (ABC) Operation Manual

STONESTAR AUSTRALIA PTY LTD

RM 12V/24V Series Solar Charge Controller User s Manual

TOD-BCU-PNUS2. Installation Manual. Connection Box for EIBS16GU2 or EIBS16GU2+ (Storage Battery System) For Installation Company Use

SK-10. Features. Solar Charge Controller User Manual. Important Safety Information

DASSAULT AVIATION Proprietary Data

ABB string inverters UNO-DM-1.2/2.0/3.3/4.0/4.6/5.0-TL-PLUS 1.2 to 5.0 kw

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

* Protected from tools and particles greater than 2.5 millimeters * Protected form low pressure water jets from any direction

Fuel Cell Lab Manual. Non Conventional Energy Systems Facility. Non Conventional Energy Systems Facility. Boiler House

USER S MANUAL SOLAR POWER INVERTER KW-6KW

MAY 2018 Improving CAPEX and OPEX of PV power plants with high power string inverters Gianluca Pieralli (Regional Sales Manager Lat Am) / Gianluca

Quick User Manual SH3K6 / SH4K6 Grid-Connected Hybrid Inverter

ZT-USB Series User Manual

Off Grid Solar Inverter. LVS 50M User Manual

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

BMS16. Thanks for your purchasing the BMS16 for your vehicle.

Power Distribution System User s Manual. Model: PDS-100

Lithium-Ion Phosphate Energy Storage System PowerCube-X1 Operation Manual

Powerware Vdc Extended Battery Cabinet User s Guide.

TMD90A Dual Input Digital Thermometer

ENERGY SOLUTIONS RESIDENTIAL STORAGE BATTERY SYSTEM

The StorEdge Solution

User Manual 3KVA/5KVA 24V INVERTER / CHARGER. Version: 1.1

APPENDIX: APPROCIMATR BACK-UP TIME TABLE

Steca Elektronik SOLARIX PLI

Voltage limiting device HVL

CPS SC Series Grid-tied PV Inverter CPS SC100KT-O/US-480. Version: 1.1

IMPORTANT SAFEGUARDS READ THIS MANUAL AND FOLLOW ALL SAFETY INSTRUCTIONS THOROUGHLY BEFORE OPERATING THE EMIU INVERTER SYSTEM SAVE THESE INSTRUCTIONS

Installation Manual for RESU10H (Type-R)

EM QUICK INSTALLATION INSTRUCTIONS

DIN-Rail DC UPS. Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

Maximum Power Point Tracking (MPPT) KA1224MPPT20A KA1224MPPT40A. Solar Charge Controller. User Manual 20A

SP PRO ABB Managed AC Coupling

ABB PV + Storage REACT-3.6/4.6-TL 3.6 to 4.6 kw

Steca Elektronik INVERTER / CHARGER WITH MPPT: SOLARIX PLI

SA-WP10-10M-VSF 24 v2

Special Specification 6058 Battery Back-Up System for Signal Cabinets

ELD Compliant Driver Application Daily Operating Guide

Transcription:

Battery & Energy Meter Quick Guide Issue: 01 Date: 2017-12-14 1 Preparing s Copyright Huawei Technologies Co., Ltd. 2017. All rights reserved. 1.1 OTICE The battery output voltage should always be lower than or equal to 500 V DC. OTE CA_H port and CA_L port of the battery are not used in this document. Preparing the battery s OTE This Chapter describes the CHIT-DDSU666 energy meter, for more energy meters, see Chapter 3 Energy Meter s Connection. 1. Prepare the battery switch between the LG RESU7H/LG RESU10H and the. Component Description Battery switch Recommended: a DC circuit breaker with a rated voltage greater than or equal to 600 V DC and a rated current of 20 A Prepared by the 2. Prepare the power cable between the LG RESU7H/LG RESU10H and the. LG RESU7H/LG RESU10H 1. Ground Connect wirethe power cable. a) Connect the ground wire. /A Single-core outdoor copper cable egative b) Connect line of the negative - line of the power BATcable. Standard PV cable in the c) power Connect cable the positive line of the power cable. the industry Positive line of the + BAT+ (recommended model: power cable PV1-F) Area Range 4 6 mm 2 /A Prepared by the 4 6 mm 2 4.5 7.8 mm Prepared by the 3. Prepare the battery communication cable between the LG RESU7H/LG RESU10H and the. Communication cable LG RESU7H/LG RESU10H (COM) 2) E GD 5) E- Four-core outdoor 3) EABLE_H 6) E+ shielded 4) RS485_H 4) 485A2 5) RS485_L 3) 485B2 twisted pair 0.25 1 mm 2 4 11 mm Prepared by the 1

1.2 Preparing the Energy Meter s 1. Prepare AC switch between the energy meter and the. Component Description AC switch Recommended: a single-phase AC circuit breaker with a rated voltage greater than or equal to 250 V AC and a rated current of 16 A (-2KTL) 25 A (-3KTL and -3.68KTL) 32 A (-4KTL, -4.6KTL, and -5KTL) Prepared by the 2. Prepare cables between the energy meter and the. CHIT-DDSU666 CHIT- DDSU666 (AC) AC output power cable between the energy meter and the 1) L L Two-core (L and ) outdoor copper cable 3) 4 6 mm 2 10 21 mm Prepared by the Communication cable CHIT- DDSU666 (COM) RS485A(+) 2) 485A1 Four-core outdoor shielded twisted RS485B(-) 1) 485B1 pair 0.25 1 mm 2 4 11 mm Prepared by the EM111DIAV81XS1X EM111DIA V81XS1X (AC) AC output power cable between the energy meter and the 2) L L Two-core (L and ) outdoor copper cable 4 6 mm 2 10 21 mm Prepared by the Communication cable EM111DIAV81X S1X (COM) 6) B+ 2) 485A1 Four-core outdoor 8) A- 1) 485B1 shielded twisted pair 0.25 1 mm 2 4 11 mm Prepared by the EM340DIAV23XS1X EM340DIA V23XS1X (AC) AC output power cable between the energy meter and the 4) L L Two-core (L and ) outdoor copper cable 4 6 mm 2 10 21 mm Prepared by the Communication cable EM340DIAV23X S1X (COM) 8) B+ 2) 485A1 Four-core outdoor 9) A- 1) 485B1 shielded twisted pair 0.25 1 mm 2 4 11 mm Prepared by the OTICE If a connector needs to connect to two signal cables, ensure that the cables have the same outer diameter. 2

2 2.1 Battery s Connection Connecting the Battery s to the Battery Pack OTICE Make sure that the Auxiliary power O/OFF switch and the Circuit Breaker switch of the battery pack are turned off before connecting the power cable to the battery pack. Make sure that the inverter AC and DC disconnections are turned off before connecting the power cable to the battery pack. 1. Connect the power cable. a) Connect the ground wire to terminal 1. b) Connect the negative line of the power cable to terminal 2. c) Connect the positive line of the power cable to terminal 3. 2. Connect the Communication. At first, connect the wire to terminal 2. Then, make connections to the 3, 4, 5 terminals one after another. 2.2 Connecting the Battery s to the DAGER Do not connect or disconnect battery cables when the is running. Failing to do so may cause electric shocks. Before connecting battery cables, ensure that the DC switch on the and all the switches connecting to the are OFF, and the has no residual electricity. Otherwise, the high voltage of the and battery may result in electric shocks. If no battery connects to the, do not remove the watertight cap from the battery terminal. Otherwise, the will not comply with its Ingress Protection Rating. If a battery connects to the, set aside the watertight cap. Reinstall the watertight cap immediately after removing the connector. The high voltage of the battery terminal may result in electric shocks. 1. Assemble the blue positive and negative connectors, and then connect the power cable. Positive metal terminal Positive connector Ensure that the locking nut is secured. egative metal terminal Ensure that the cable will not be extracted after crimped. egative connector Pull the power cable back to ensure that it is connected securely. Click Save the watertight caps for later use. Pull the battery cable back to ensure that it is connected securely. WARIG Do not connect any load between the and the battery. Ensure that the following conditions are met. Otherwise, the will be damaged, or even become a fire hazard. The battery cable is connected correctly. That is, the positive and negative terminals of the battery connect to the positive battery terminal and negative battery terminal on the respectively. The cable between the battery and the should be less than or equal to 10 meters, and within 5 meters is recommended. The battery voltage will result in fatal injury. Use dedicated insulation tools to terminate cables. Ensure that the battery cable is correctly connected. Avoid reverse polarity. 3

2. Connect the Communication. o. Label Definition 3 485B2 4 485A2 RS485B, RS485 differential signal RS485A, RS485 differential signal+ 5 E Enable signal 6 E+ Enable signal+ 8 PE Grounding the shield layer OTICE When laying out signal cables, separate them from power cables to avoid strong signal interference sources. The protection layer of the signal cable is in the connector. Surplus core wires are cut off from the protection layer. The exposed core wire is totally inserted into the cable hole and connected securely. 3 3.1 Energy Meter s Connection Connection Connecting the Energy Meter s to the 1. Connect the AC output power cable to the. a) Connect the AC output power cable to the AC connector. Click b) Connect the AC connector to the AC output port. c) Check the route of the AC output power cable. 2. Connect the communication cable to the. 4

3.2 Connecting the Energy Meter s to the Energy Meter CHIT-DDSU666 Open the front cover, then connect the cable to the CHIT-DDSU666. Top veiw 7) 485A 8) 485B 4) 8) RS485B 7) RS485A 3) 4) 3) Side veiw COM 2) 485A1 1) 485B1 AC L Power grid Front cover AC switch CHIT-DDSU666 1) L 2) L Front cover Bottom veiw L L 1) L 5) P+ 6) PQ- 2) L EM111DIAV81XS1X OTE Load P+ port and PQ+ port are not used in this document. The energy meter is recommended to install in the original residential power distribution unit. The energy meter can also be independently installed outside the original residential power distribution unit. Open the front cover, then connect the cable to the EM111DIAV81XS1X. L L COM 2) 485A1 1) 485B1 AC L Power grid B+ A- AC switch Residential power distribution unit OTE The energy meter is recommended to install in the original residential power distribution unit. The energy meter can also be independently installed outside the original residential power distribution unit. L Load 5

EM340DIAV23XS1X Open the front cover, then connect the cable to the EM340DIAV23XS1X. L1 L2 L3 COM 2) 485A1 1) 485B1 AC L EM340DIAV23XS1X AC switch B+ A- Power grid L1 L2 L3 OTE The energy meter is recommended to install in the original residential power distribution unit. The energy meter can also be independently installed outside the original residential power distribution unit. L1 L2 L3 Residential power distribution unit 3 Commissioning 3.1 Powering On the System Load 1. Put the battery pack in operation by taking the following steps: a) Turn on the Auxiliary power O/OFF switch after installation battery pack. Make sure that the Circuit Breaker switch is in the OFF position. (including Trip position) b) Move the Circuit Breaker switch to the O position. Auxiliary power O/OFF switch Circuit Breaker switch c) Seconds after the Circuit Breaker switch is O, 4 LEDs will be lit. d) Make sure that O indicator is on and see if the battery pack is successfully initialized. The power on indicator on the front should turn on in green. e) Close wiring box cover. 6

2. Power on the : OTICE. Before turning on the AC switch between the and the power grid, check that the AC voltage on the power grid side of the AC switch is within the specified range If the DC is on and the AC is off, the reports a Grid Failure alarm. The starts normally only after the fault is rectified. If the AC is on and the battery is off, the reports a Battery Abnormal alarm. (A) PV string (B) DC switch (C) (D) AC switch (E) Residential power distribution unit (F) Energy meter (G) Residential power meter (H) Power grid (I) Battery (J) Battery switch (K) Alarm beacon (L) Residential load a) Turn on the battery switch between the battery pack and the. b) Turn on the AC switch between the and the power grid. OTICE If the is connected to the battery, after turning on the AC switch: If the DC switch is turned on within 1 minute, the will run properly in grid-tied mode. If the DC switch is not turned on within 1 minute, the will enter the nighttime grid-tied mode. Then, after the DC switch is turned on, the will shut down and then restart to run in grid-tied mode. c) Turn on the DC switch between the PV string and the if there is any. d) Turn on the DC switch at the bottom of the. e) Perform quick setting over the FusionHome app. There are two method to add battery. Method 1: tap Go to set after quick setting is complete, and then configure parameters on the Add/Delete device screen. Method 2: on the Operation console screen, choose Device maintenance > Add/Delete device, and add battery according to actual conditions. 7

Energy Meter Parameter Description Value Range Comm address Meter model Specifies the RS485 address for the connected power meter. The address should be the same as the actual address for the power meter. Specifies the model of the connected power meter. o power meter of other models can be connected. [1, 247] CHIT-DDSU666 EM111DIAV81XS1X EM340DIAV23XS1X Battery Parameter Description Value Range Comm address Battery type Maximum Discharging Power Maximum Charging Power Specifies the RS485 address for the connected battery. The address should be the same as the actual address for the battery. Specifies the type of the connected battery. o battery of other types can be connected. Specifies the maximum battery charging power. The maximum charging power is limited by the maximum output power of the and whether the charge/discharge power function is enabled. Specifies the maximum battery discharging power. The maximum discharging power is limited by the maximum output power of the and whether the charge/discharge power function is enabled. [1, 247] LG-RESU [0, 3500] [0, 3500] Full Charging Capacity Specifies the battery charging cutoff capacity. [90, 100] Full Discharging Capacity Specifies the battery discharging cutoff capacity. [12, 20] f) (Optional) Measure the temperatures at the joints between the DC terminals and the connectors using a point-test thermometer. OTE Under normal operation conditions of the, the temperature rise at DC connectors should remain below 30 C at all time. g) Observe the LEDs to check the operating status. 8

3.2 Checking the Match between the and Battery Protocol OTICE The following text describes the operations on ios screens. The operations on Android screens are the same as those on ios screens, except that the screens are somewhat different. The actual screens prevail. In the ios system, the upgrade file can be imported to the mobile phone over your mailbox. The upgrade file name extension must be.zip. Manually select is unavailable. In the Android system, the upgrade file can be copied to the mobile phone. The upgrade file name extension must be.zip and the file can be stored in your required directory. Manually select is available. 1. On the FusionHome app, choose Device maintenance > Upgrade device to view the version. Upgrade the if its version is earlier than V100R001C00SPC305. a) Import the upgrade package to the mobile phone over your mailbox, and then log in to the FusionHome app as installer. b) Upgrade the, the upgrade takes about five minutes. When the upgrade successfully, the will be restart, log in again after the restart. 9

2. Ensure that the battery cable connection and parameter settings (Comm addr: 15, Battery type: LG-RGSU) are correct. Then in either of the three following cases, upgrade the battery. o. Mismatch Case Remark LG RESU10H: LG RESU7H: 1 On the FusionHome app, choose Device maintenance > Upgrade device to view the battery version. Upgrade the LG RESU10H if DCDC Current version is not 7kW-V4.7. Upgrade the LG RESU7H if DCDC Current version is not 5kW-V4.7. 2 The battery is offline and not working properly. View the battery status by choosing Device info > Device status on the FusionHome app. 3 The battery status is displayed on the Device status screen. The battery auxiliary power indicator is on but the battery charging and discharging indicators are off. Battery auxiliary power indicator Battery charging indicator Battery discharging indicator OTE In the ios system, the upgrade file can be imported to the mobile phone over your mailbox. The upgrade file name extension must be.zip. Manually select is unavailable. 10

a) Import the battery upgrade package to the mobile phone over your mailbox, and then log in to the FusionHome app as installer. The upgrade package for the LG RESU10H is RESU10H_DCDC_UPGRADE_PACK.ZIP. The upgrade package for the LG RESU7H is RESU7H_DCDC_UPGRADE_PACK.ZIP. b) Select upgrade package to upgrade the battery from V2.0 to V4.7. The upgrade takes about five minutes. The upgrade package for the LG RESU10H is RESU10H_DCDC_UPGRADE_PACK.ZIP. The upgrade package for the LG RESU7H is RESU7H_DCDC_UPGRADE_PACK.ZIP. The following figure uses LG RESU10H upgrade as an example. 11

3. After completing the upgrade, check that the battery is working properly. 3.3 Powering Off the System 1. Power off the : WARIG After the powers off, the remaining electricity and heat may still cause electric shocks and body burns. Therefore, put on protective gloves and begin servicing the 5 minutes after the power-off. If you have not sent a shutdown command from the app, after turning off the AC switch, turn off the DC switches within 1 minute. Otherwise, the will restart and charge the batteries (not connected to the grid). It will not shut down until you turn off the DC switches. a) Send a shutdown command from the app. If you log in as installer On the Operation console screen, choose Device maintenance > Inverter O/OFF, and perform operations as required; if you log in as user, On the main screen, choose > Set maint > Inverter O/OFF, and perform operations as required. b) Turn off the AC switch between the and the power grid. c) Turn off the DC switch at the bottom of the. d) Turn off the DC switch between the PV string and the if there is any. e) If a battery connects to the battery port, turn off the battery switch. (A) PV string (B) DC switch (C) (D) AC switch (E) Residential power distribution unit (F) Energy meter (G) Residential power meter (H) Power grid (I) Battery (J) Battery switch (K) Alarm beacon (L) Residential load 2. Power off the battery pack: WARIG Do not turn o the Auxiliary Power O/OFF switch at normal operation mode such as charge and discharge mode. If not using the battery pack for a long time or there is any fault on the battery pack, turn o the Circuit Breaker, then turn o the Auxiliary Power O/OFF switch. a) Remove the wiring box cover. b) Turn off the battery pack by moving the Circuit Breaker switch to the OFF position. c) Make sure that every indicator on the battery pack is off. It should take 60 seconds at most for the indicators to turn off. d) Turn off the Auxiliary Power O/OFF switch. e) Close wiring box cover. Auxiliary power O/OFF switch Circuit Breaker switch 12

4 Troubleshooting Alarm ID Alarm ame Alarm Severity Possible Cause Suggestion 2067 Faulty Power Collector 2068 Abnormal Battery Major Cause ID = 1 In Grid Connection with Zero Power mode, the power collector communication is interrupted. In Maximum Use of Self- Produced Power mode, the power collector communication is interrupted. Minor Cause ID = 1 The battery is faulty. The battery communication is interrupted. The battery switch trips when the is running. 1. Check that the preset power collector model is the same as the actual model. 2. Check that the preset communications parameters for the power collector are the same as the actual configurations. 3. Check that the power collector is powered on and the RS485 communications cable is correctly connected. 1. Check that the communications cable and power cable between the and the battery are properly connected. 2. Check that the battery switch is turned on properly. 3. Turn off the AC output switch, DC input switch, and battery switch, and then turn them on after 5 minutes. If the fault persists, contact your dealer. 13