CM10-3 A-R-A-E-AVBE F-A-A-N

Similar documents
CM5-5 A-R-A-E-AVBE F-A-A-N

CM5-11 A-R-G-E-AQQE F-A-A-N

CM1-6 A-R-I-E-AQQE F-A-A-N

CM5-5 A-R-A-E-AVBE C-A-A-N

CM25-1 A-R-G-E-AQQE C-A-A-N

Set 2 Mini Pust APB50B

CM5-9 A-R-I-E-AQQE F-A-A-N

CM10-1 A-R-A-E-AQQE F-A-A-N

CM15-1 A-R-I-V-AQQV C-A-A-N

CM1-2 A-R-A-E-AQQE F-A-A-N

CM10-3 A-R-G-V-AQQV F-A-A-N

CM3-11 A-R-G-E-AQQE F-A-A-N

CM3-5 A-R-I-E-AQQE F-A-A-N

CM1-8 A-R-I-E-AQQE F-A-A-N

CM5-5 A-R-G-V-AQQV F-A-A-N

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CM5-6 A-R-A-E-AQQE C-A-A-N

CM3-6 A-R-G-E-AQQE C-A-A-N

CME1-4 A-R-I-E-AQQE S-A-D-N

CM1-5 S-R-I-E-AQQE C-A-A-N

CM1-3 S-R-I-E-AQQE C-A-A-N

UNIT TAG: TYPE OF SERVICE: SUBMITTED BY: APPROVED BY: ORDER NO.: CME3-7 A-S-I-E-AVBE. Pump Data

TP /2-A-F-A-BAQE 400D 50HZ

MTB /183 A-F-A-BQQV 400D-2 11kW

Company name: GRUDNFOS VisMin Created by: Kimmboy Ancis Phone: Date: 13/03/2017

CR10-10 A-A-A-E-HQQE 3x400D 50 HZ

TP /4-A-F-A-BUBE 400Y 50HZ

CR45-10 A-F-A-E-HQQE 3x400/ HZ

TP 40-30/4-A-F-A-BUBE 400Y 50HZ

TP /2-A-F-A-BQQE 400D 50HZ

CR15-10 A-F-A-E-HQQE 11kW 3x400D 50Hz

CME5-5 A-R-I-E-AQQE S-A-D-N

CR A-F-A-E-HQQE 3x400/ HZ

CR45-5 A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR5-26 A-FGJ-A-E-HQQE 3x400D 50HZ

CR1-6 A-A-A-E-HQQE 3x230/400 50HZ

CR1-3 A-A-A-E-HQQE 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR A-F-A-E-HQQE 3x400/ HZ

NK /310A2F1AE-SBAQE

CR10-02 A-A-A-E-HQQE 3x230/ HZ

CR3-10 A-A-A-E-HQQE 3x230/400 50HZ

CRN120-7 A-F-G-V-HBQV 75kW 3x400D 50Hz

CR10-07 A-FJ-A-E-HQQE 3x400D 50 HZ

CR10-04 A-A-A-E-HQQE 15kW 3x400Y 50Hz

CR A-F-A-V-HBQV 3x400/ HZ

CR5-16 A-A-A-E-HQQE 3x400D 50HZ

Hydro MPC-E 2CRIE L GNL

CR120-2 A-F-A-E-HQQE 3x400/ HZ

CRT 16-4 A-P-A-E-AUUE 4kW 3x400D 50Hz

CR10-01 A-A-A-E-HQQE 1x220/ HZ

CR1S-6 A-A-A-E-HQQE 1x220/240 50HZ

CRI1-6 A-P-I-E-HQQE 3x230/400 50HZ

CR3-13 A-A-A-E-HQQE 1x220/240 50HZ

CR15-02 A-F-A-E-HQQE 3x400D 50 HZ

CR1-9 A-A-A-E-HQQE 1x220/240 50HZ

CR A-F-A-V-HQQV 3x400/ HZ

CRT 8-20 A-P-A-E-AUUE 11kW 3x400D 50Hz

CR3-2 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN45-10 A-F-G-V-HQQV 3x400/ HZ

CRI10-14 A-FGJ-I-E-HQQE 3x400D 50 HZ

CRN A-F-G-V-HQQV 3x400/ HZ

CRN5-7 A-P-G-E-HQQE 3x230/400 50HZ

CRN15-09 A-P-G-V-HQQV 3x400/ HZ

CRI3-6 A-FGJ-I-E-HQQE 3x230/400 50HZ

TP /4-A-F-A-BQQE 400Y 50HZ

CR5-6 A-FGJ-A-E-HQQE 3x230/400 50HZ

CR3-19 A-FGJ-A-E-HQQE 3x230/400 50HZ

CRN3-25 A-P-G-E-HQQE 3x400D 50HZ

CRN15-17 A-FGJ-G-V-HQQV 3x400/ HZ

CRN15-03 A-P-G-V-HQQV 3x400D 50 HZ

CRN15-12 A-P-G-E-HQQE 3x400/ HZ

CRN20-02 A-FGJ-G-E-HQQE 3x400D 50 HZ

CRN45-5 A-F-G-V-HQQV 3x400/ HZ

NB /193 A-F2-A-BAQE

CRN A-F-G-V-HQQV 30kW 3x400D 50Hz

CR3-6 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR1-3 A-FGJ-A-E-HQQE 1x220/240 50HZ

CRK 2-60/6 AWA-BUBV 075KW 3X400V 50HZ

CMB-SP 3-28 I-C-A-C-A-A

CRN A-F-G-V-HQQV 3x400/ HZ

TP /2-A-F-A-BQQE 400D 50HZ

CRE20-03 A-A-A-E-HQQE 3x HZ

TP /2-A-F-A-BUBE 1X230 50HZ

CRN3-6 A-P-G-V-HQQV 3x230/400 50HZ

CRE10-02 A-A-A-E-HQQE 1x HZ

CRN15-01 A-P-G-V-HQQV 3x230/ HZ

NB /263 AS-F2-A-BAQE

CR45-3 A-F-A-E-HQQE 3x400/ HZ

CR10-08 A-A-A-E-HQQE 3x400D 50 HZ

CRN3-3 A-FGJ-G-V-HQQV 3x230/400 50HZ

CRN1-27 A-P-G-V-HQQV 3x230/400 50HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CRN3-11 A-P-G-V-HQQV 11kW 3x400Y 50Hz

Grundfos pump

CRT 2-4 A-P-A-E-AUUE 055kW 400Y 50Hz

NK40-160/172A1F2AE-SBAQE

CRE15-01 A-F-A-E-HQQE 1x HZ

CR15-14 A-F-A-E-HQQE 3x400/ HZ

Transcription:

GRUNDFOS DATA BOOKLET CM1-3 A-R-A-E-AVBE F-A-A-N Grundfos Pump 9686946 Thank you for your interest in our products Please contact us for more information, or visit our website https://www.lenntech.com/grundfos/cmbasis/9686946/cm1-3-a-r-a-e-avbe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CM1-3 A-R-A-E-AVBE Product No.: 9686946 Compact, reliable, horizontal, multistage, end-suction centrifugal pump with axial suction port and radial discharge port. The shaft, impellers and chambers are made of stainless steel. The inlet and discharge parts are made of cast iron. The mechanical shaft seal is a special designed, unbalanced O-ring seal. Pipework connection is via internal Whitworth pipe threads, Rp (ISO 7/1). The pump is fitted with a 3-phase, foot-mounted, fan-cooled asynchronous motor. Further product details Pump and motor are integrated in a compact and user-friendly design. The pump is fitted to a low base plate, making it ideal for installation in systems where compactness is important. The state-of-the-art design and materials of the shaft seal ensure high wear resistance, improved sticking and dry-running capabilities and long operating life. Servicing the pump requires no special service tools. Service parts are in stock for quick delivery and are available as kits, single parts or bulk. Service videos are available on www.youtube.com. Pump A combination of a stop ring and a Nord-lock washer secures a tight and reliable fixation of the impeller spacing pipes to the splined pump shaft. It is possible to remove and fit the hydraulic parts from the pump side. The inlet part, chambers and discharge part are hold together by four staybolts. The pump is fitted with an unbalanced O-ring seal with a rigid torque transmission system. It has a fixed seal driver ensuring a reliable rotation of all parts. The dynamic secondary seal is an O-ring. Primary seal: - Rotating seal ring material: Aluminium oxide (alumina) - Stationary seat material: Carbon graphite, resin-impregnated Carbon graphite against alumina is a good all-round seal for not too demanding applications. The corrosion resistance is often limited in water to a range between ph 5 and ph 1. Usage in liquids above +9 C is not recommended. The seal can handle dry-running conditions for short periods. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The pump shaft is connected to the motor shaft through a left thread and tight fit. The shaft cannot be dismantled. Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to EN 5347. Electrical tolerances comply with EN 634. The motor efficiency is classified as IE2 in accordance with IEC 634-3. The motor does not incorporate motor protection and must be connected to a motor-protective circuit breaker which can be manually reset. The motor-protective circuit breaker must be set according to the rated current of the motor (I1/1). An installation indicator is fitted to the motor fan cover. Based on the motor cooling air, it indicates the direction of rotation of the motor. The motor is fitted with a directional sticker.

The motor can be connected to a variable speed drive for adjustment of pump performance to any duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in Grundfos Product Center. Technical data Liquid: Pumped liquid: Water Liquid temperature range: -2.. 9 C Liquid temperature during operation: 2 C Density: 998.2 kg/m³ Technical: Speed for pump data: Rated flow: Rated head: Primary shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing: Impeller: Rubber: 29 rpm 1 m³/h 4.5 m AVBE CE,WRAS,ACS,TR,EAC ISO996:212 3B Cast iron EN-JL13 ASTM 3 B Stainless steel DIN W.-Nr. 1.431 AISI 34 EPDM Installation: Maximum ambient temperature: 55 C Maximum operating pressure: 1 bar Max pressure at stated temp: 6 bar / 9 C 1 bar / 4 C Flange standard: WHITWORTH THREAD RP Pump inlet: Pump outlet: Electrical data: Motor type: 9SC IE Efficiency class: IE2 Rated power - P2: 2.2 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24D/38-415Y V Service factor: 1 Rated current: 8,15-7,85/4,7-4,5 A Starting current: 89-12 % Rated speed: 288-291 rpm Motor efficiency at full load: 83.2 % Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Others: Minimum efficiency index, MEI :,7 Net weight: 35.8 kg Gross weight: 38.3 kg

9686946 CM1-3 5 Hz H [m] CM1-3, 3*4 V, 5Hz eta [%] 5 1 45 9 4 8 35 7 3 6 25 5 2 4 15 3 1 2 5 1 1 2 3 4 5 6 7 8 9 1 11 12 13 14 15 P [kw] Q [m³/h] NPSH [m] 2.5 25 2. P1 P2 2 1.5 15 1. 1.5 5.

12 Rp 3/8 29.5 241.8 49.7 16 199 14 17 219 24 19.4 271.7 91.8 127.2 363.5 Description Value General information: Product name: CM1-3 A-R-A-E-AVBE Product No: 9686946 EAN number: 5731918938 Technical: Speed for pump data: 29 rpm Rated flow: 1 m³/h Rated head: 4.5 m Impellers: 3 Primary shaft seal: AVBE Approvals on nameplate: CE,WRAS,ACS,TR,EAC Curve tolerance: ISO996:212 3B Pump version: A Model: A Materials: Pump housing: Cast iron EN-JL13 ASTM 3 B Impeller: Stainless steel DIN W.-Nr. 1.431 AISI 34 Material code: A Rubber: EPDM Code for rubber: E Installation: Maximum ambient temperature: 55 C Maximum operating pressure: 1 bar Max pressure at stated temp: 6 bar / 9 C 1 bar / 4 C Flange standard: WHITWORTH THREAD RP Connect code: R Pump inlet: Pump outlet: Liquid: Pumped liquid: Water Liquid temperature range: -2.. 9 C Liquid temperature during operation: 2 C Density: 998.2 kg/m³ Electrical data: Motor type: 9SC IE Efficiency class: IE2 Rated power - P2: 2.2 kw Mains frequency: 5 Hz Rated voltage: 3 x 22-24D/38-415Y V Service factor: 1 Rated current: 8,15-7,85/4,7-4,5 A Starting current: 89-12 % Rated speed: 288-291 rpm Motor efficiency at full load: 83.2 % Enclosure class (IEC 34-5): IP55 Insulation class (IEC 85): F Motor protec: NO Others: Minimum efficiency index, MEI :,7 Net weight: 35.8 kg Gross weight: 38.3 kg H [m] 5 45 4 35 3 25 2 15 1 5 2 4 6 8 1 12 P [kw] 2.5 2. 1.5 1..5. Rp 3/8 12 TO AMPLIFIER RELAY TO AMPLIFIER 19.4 16 199 +T 1 241.8 +T +T +T L1 L2 L3 +T +T 29.5 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY CM1-3, 3*4 V, 5Hz 363.5 271.7 THERMISTORS PTC ACCORDING TO DIN 4482 14 17 49.7 91.8 127.2 219 24 Q [m³/h] P1 P2 9 8 7 6 5 4 3 2 1 eta [%] 1 25 2 15 1 5 NPSH [m] RELAY L1 L2 L3

9686946 CM1-3 5 Hz cos phi eta CM1-3 + 9SC 2.2 kw 3*4 V, 5 Hz, SF = 1 I [A] I eta.8 cos phi 4..6 3..4 2..2 1...1.2.3.4.5.6.7.8.9 1. 1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9 2. 2.1 n [rpm] P2 [kw]. P1 [kw] 3 P1 n 28 2. 26 1. 24.

9686946 CM1-3 5 Hz 1 241.8 Rp 3/8 12 19.4 16 199 363.5 271.7 91.8 127.2 14 17 49.7 219 24 29.5 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details.

9686946 CM1-3 5 Hz +T +T +T TO AMPLIFIER RELAY +T TO AMPLIFIER RELAY L1 L2 L3 +T +T L1 L2 L3 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 Note! All units are in [mm] unless others are stated.

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89