Operating manual Fluid pre-heaters BINAR-5S BINAR-5S diesel BINAR-5S.24 diesel

Similar documents
Operating manual. Fluid pre-heaters. BINAR-5S BINAR-5S-TM BINAR-5S (diesel) BINAR-5S-TM (diesel) BINAR-5S-24-TM (diesel)

AUTOMATIC STANDBY ACTIVATION. Operation Manual

Fuel Fired Booster Heater

Operation of the FFBH is enabled and disabled by the Automatic Temperature Control Module (ATCM).

Diesel Cooker x100. Operating and Maintenance Instructions

MOBILAIR M 27/M 31. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 1.90 to 3.15 m³/min (67 to 110 cfm)

A2P Single Phase Automatic Industrial Battery Charger

Binar 5B, Binar 5B-С, Binar 5D, Binar 5D-С engine pre-heater for vehicles with liquid cooling system

IP 900 W/KS & IP 900 D/KS

Tips & Technology For Bosch business partners

60 KW / 75 KVA POWERED by

130 KW / 165 KVA POWERED by

Troubleshooting and Repair Instructions. Eberspächer. The troubleshooting and repair instructions are only applicable to the following unit versions

Heating and ventilation

Diesel Cooker X 100. Installation Instructions

300 KW / 375 KVA POWERED by

COMPRESSORS MOBILAIR M 36/M 45. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 3.9 to 4.2 m³/min ( cfm)

User s Manual. Automatic Switch-Mode Battery Charger

KOMPRESSOREN MOBILAIR M 43/M 50. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 4.2 to 5.0 m³/min ( cfm)

70 KW / 90 KVA POWERED by

DASSAULT AVIATION Proprietary Data

Pure sine wave charger inverter Product Manual

30 KW / 40 KVA POWERED by

Heating and Gas Installations - December 2014

500 KW / 625 KVA POWERED by

Malfunction Criteria and Threshold Value Adaptive value. Secondary Parameters with Enable Conditions. >50.8 S Engine load 9-45% Delta fuel adaptation

Twin dual-line lubrication system

23 KW / 29 KVA POWERED by

COMPRESSORS MOBILAIR M 115. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 11.5 m³/min ( cfm)

Assembly instructions

Function of Preglow System

16 KW / 20 KVA POWERED by

MOBILAIR M 114. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 7.5 to 9.7 m³/min ( cfm)

G-I PCM SERVICE MANUAL M50/M80

Engine mechanics. Crankcase ventilation outlet

TECHNICAL SPECIFICATION TYPE BREEZE IV

Twin dual-line lubrication system

HST -LS Interlocking device (Translation of Original Manual)

Tips & Technology For Bosch business partners

CoolFreeze CFX35, CFX40, CFX50, CFX65, CFX65DZ

Twin dual-line lubrication system

20 KW / 25 KVA LIQUID COOLED POWERED by

Section 3 Technical Information

Operating & Maintenance Manual

Pulsar Evolution 1500 / 1500 Rack 1100 / 1100 Rack 800 / 800 Rack 500 Rack

Modulating Furnace Information. Warning on Meter Setting - Read First!

Installation manual portable distributors

MEGA WAY LCD PAGER ALARM WITH REMOTE ENGINE STARTER. Operation Manual MEGATRONIX CHATSWORTH, CA U.S.A. MEGA 2700 OPERATE 1

100 KW(NG) / 100 KW(LP) LIQUID COOLED POWERED by

B 4 W SC and B 5 W SC

MRXBOX-VSC Visual System User Control Installation and Maintenance

Model No.: outdoor unit U-16GE3E5 U-20GE3E5 U-25GE3E5 U-30GE3E5 U-16GF3E5 U-20GF3E5 U-25GF3E5

MACK SERVICE AGREEMENTS.

MAGNETIC MOTOR STARTERS

700 KVA / 550 KW POWERED by

Drained coolant must be stored in a clean container for disposal or reuse.

INSTALLATION, SERVICE AND OWNER S MANUAL MODELS: XL900 XL1500

BUILT FOR PEACE OF MIND

-ty EYDESCREEN MANUF=ACTUFIINC. Operating lnstructions MANUAL

130 KW / 165 KVA POWERED by

Technical Note 3676A CB1N

E Series CE Approved Intermittent Pilot Ignition Control

Combustion process Emission cleaning Fuel distribution Glow plugs Injectors Low and high pressure pumps

DKG-114 MANUAL AND REMOTE START UNIT

SPECIFICATIONS Horsepower: 1.5 HP Running Maximum PSI: 125 PSI Tank Capacity: 15 Gallons CFM: 6 40 PSI 5 90 PSI

Citroen Jumpy / Fiat Scudo / Peugeot Expert

ALWAYS follow all Webasto installation and repair instructions and observe all warning instructions.

18 KW / 18 KVA POWERED by

APPLICATION NOTE: OPEN LOOP INTEGRATION WITH VICTRON ENERGY

PRESSURE GOVERNOR, ENGINE MONITORING, AND MASTER PRESSURE DISPLAY MODEL DDA100

The Combustex Pilot Pro 800 Pilot Burner Assembly with Ignition & Flame Failure Monitor

OPERATING INSTRUCTIONS

A E R Z E N S C R E W C O M P R E S S O R S

TECHNICAL DEVELOPMENT OF VEHICLE JE0X LAUNCH DATE OF VEHICLE EQUIPPED WITH THE PASSENGER COMPARTMENT CONNECTION UNIT (BII)

Spare parts list A WORLD OF COMFORT. Heaters for petrol B 4 S 12 V B 5 S 12 V

55 KW / 70 KVA POWERED by

Installation manual wall-mounted distributor

ALWAYS follow all Webasto installation and repair instructions and observe all warnings.

Instructions for use Attention

204 KW / 254 KVA POWERED by

G76x Direct Spark Ignition Controls

57 KW / 71 KVA POWERED by

Compact Air Solutions C Series kw Screw Compressors

EasyStart. 364 (3 ton) Soft Starter 368 (6 ton) Soft Starter. Installation Manual

Owners Manual: - Pumps

18SP675Rev. MBE 900 Grid Heater Relay Installation Instructions (P/N: A )

National Certificate in Motor Industry (Automotive Machining)

MOBILAIR M 114. Portable Compressors With the world-renowned SIGMA PROFILE Flow rate 7.5 to 9.7 m³/min ( cfm)

Variable Valve Timing

Hayward error codes and troubleshooting

3.2 Air Conditioning (A/C) Model 140 up to M.Y. 1995

EasyStart 364 (ASY-364-X20-IP) Installation Instructions for the Coleman / Airxcel Air Conditioners

DIESEL FIRED COOLANT HEATERS

Operating conditions of VRLA batteries in HVCBS and LVDBS Systems

ALWAYS follow all Webasto installation and repair instructions and observe all warning instructions.

MOBILAIR M 20. Portable Compressor With the world-renowned SIGMA PROFILE Flow rate 2.0 m³/min (71 cfm)

AIRTRONIC / AIRTRONIC M Troubleshooting and Repair Instructions

80 KW / 100 KVA POWERED by

Citroen C1 / Peugeot 107 / Toyota Aygo

640 KW / 800 KVA POWERED by

Transcription:

EN Operating manual Fluid pre-heaters BINAR-5S BINAR-5S diesel BINAR-5S.24 diesel

Dear Customers, Allow us to thank you for your choice! We have done everything to ensure that this product meets your requirements and for its quality to correspond to the top world brands. Introduction The BINAR-5S type fluid pre-heaters are intended for: heating the engine at low ambient air temperatures; ancillary tempering when the engine is running in extreme frost conditions; to heat the cabin and windscreen at very low temperatures (to eliminate frost), when the engine is not running. The pre-heater operates independent of the engine of the means of transport. The operating principle of the pre-heater consists in heating the fluid in the cooling system, which is pumped through the exchanger system of the heater. Carefully read this operating manual in order to get properly acquainted with all the pre-heater functions. Health and safety rules Installation of the pre-heater and its components must be entrusted to specialist organisations approved by the manufacturer. Installation of the pre-heater must bed one only by experts according to the installation instructions. Risk to human health The pre-heater may be used only for purposes stipulated in this operating manual. Due to the risks that arise from the exhaust gases of the preheater when it is in operation, it is not possible to use the preheater when the vehicle is parked in closed unventilated spaces (garages, workshops, etc.). A vehicle equipped with a pre-heater must have a fireextinguisher.

Risk of damage to/destruction of property When refuelling, the pre-heater must be off. It is prohibited to disconnect the electric power supply of the pre-heater before end of the purging cycle. It is prohibited to connect and disconnect the sockets of the pre-heater when the pre-heater power supply is on. It is prohibited to climb unto the heater and place items on it. If electrical welding work is being done on the motor vehicle, it is necessary to disconnect the pre-heater from the battery. After shut-down the pre-heater may not be restarted earlier than after lapse of 5-10 seconds. If attempts to start-up the pre-heater fail twice in a row, it is necessary for reason of safe operation of the pre-heater to contact the service centre, which shall repair such fault. Control of the pre-heater Control panel PU-20 Manual or automatic start-up of the pre-heater. Manual start-up of the pump. Setting of the operating time. Setting the time and day of the week. Setting of three start-up timers. Activation of one of the start-up timers. Display of the actual temperature of the coolant. Display of the operating time. Display of the power supply voltage. Display of the control unit software version. Modem GSM-SIMCOM Remote, manual or automatic start-up of the pre-heater. Remote, manual start-up of the pump. Viewing of coolant temperature data. Viewing of power supply voltage data. Viewing of the actual operating time. Indication of the error code. Remote signalling Start-up of the heater (the operating time corresponds to the last entered variable)

Liability The consequence of failure to respect this operating manual and the requirements contained in it is demise of any liability on the part of the manufacturer. The same applies to repairs done by an expert without the appropriate qualifications, or repairs in which genuine spare parts were not used and such spare parts were not authorised by the manufacturer. In case of any problems, we emphatically recommend that you contact the authorised service centres, whose addresses and telephone numbers are available from the dealer or at the website www.autoterm.ru Complete assembly. The standard complete pre-heater assembly contains the following: - heater; - fuel pump; - pump; - fuel intake or T-branch; - harnesses; - air intake with silencer; - exhaust pipe; - installation kit. As accessories to the standard pre-heater assembly, it is possible to additionally purchase install the following: - control panel; - modem GSM-SIMCOM; - relay kit (for connection to the heating equipment in the cabin or control of the overall climatic conditions in the cabin); - exhaust pipe silencer; - bushing (rubber ring, which protects the plastic elements of the motor vehicle from contact with the hot exhaust pipe) Specifics of automatic control. 1) if the pre-heater fails to start-up for whatever reason, then the start-up process is repeated automatically. After 2 unsuccessful attempts, the pre-heater goes off; 2) if the combustion process fails during pre-heater operation, the pre-heater re-ignites. Maximum number of flame failures 3; 3) upon drop of voltage below 9.5V (20V) or its rise above 16V (30.8V) the pre-heater is shut-down; The values for products with a nominal voltage of 24V are shown in brackets; 4) in case of emergency shut-down of the pre-heater, a digital error code appears on the control panel (PU-20).

, If the pre-heater operation ends in an error, the next start-up is in reheat mode. For further operation, it is necessary to start-up the pre-heater manually. This procedure is necessary to erase the error. Technical service We recommend regular technical maintenance and inspection of the pre-heater at specialised service centres. A lot of work related to the repair and technical service of the pre-heater requires professional knowledge and use of special tools. Unprofessionally done technical maintenance and service may result in damage to the pre-heater. We recommend the separate performance of the following tasks: If the pre-heater is not in operation, then in order to ensure its reliable operation, it is necessary to start it up once per month for 5-10 minutes, including the summer season. Regularly check the battery charge level. If the vehicle is parked or stationary for a long time, it is necessary to disconnect the pre-heater from the power supply (battery). In this way, we prevent complete discharge of the battery (even in inoperational state the pre-heater consumes current (30 40) mа). The reliable operation of the heater depends on the brand of the fuel used. The fuel brand must be chosen according to the ambient temperature. Faults. What to do in case of fault: check the presence of fuel in the tank and the fuel pipe downstream of the pump; check the 25А circuit breaker; check the reliability of the contract connections in the sockets and circuit-breaker terminals (it is not possible to rule out the oxidation of contacts); disconnect the power terminal for 1-2 minutes and reconnect. All other arising faults can be identified according to the error code, which appears on the panel.

Characteristics. Names of parameters BINAR-5S Models Heating output, kw 5 0.5 Rated voltage, V 12 Operating voltage, V 9.5 16 Fuel type Petrol (GOST Р 51105) BINAR-5S diesel motor diesel (GOST 305) Fuel consumption (max), litres/hour 0.7 0.62 Heating medium Tosol, anti-freeze coolant Electric power input together with pump (maximum), W 73 Start-up power input (100 s), W 122 Start-up mode manual or automatic Duration of one operating cycle, minutes 20 120 Weight of the pre-heater with all accessories, kg, maximum 8