KVA KW KVA KW

Similar documents
KVA KW KVA KW

KVA KW KVA KW

POWER MODULE MTU 16V4000 DS2560

موتور ديزل : Caterpillar. ژنراتور : Caterpillar. Standby. Prime KVA KW KVA KW

موتور ديزل : Caterpillar. ژنراتور : Caterpillar. Standby. Prime KVA KW KVA KW

DIESEL GENERATOR SET MTU 18V2000 DS1400

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET DP01800D5S

DIESEL GENERATOR SET MTU 20V4000 DS3250

DIESEL GENERATOR SET MTU 20V4000 DS2650

DIESEL GENERATOR SET MTU 12V4000 DS2000

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET DP03000D5S

DIESEL GENERATOR SET DS01650D5S

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET DS03200D5S

DIESEL GENERATOR SET MTU 20V4000 DS3100

DIESEL GENERATOR SET MTU 16V2000 DS1100

DIESEL GENERATOR SET MTU 16V4000 DS2250

موتور ديزل : Cummins. ژنراتور : Stamford. Standby. Prime KVA KW KVA KW ديزل ژنراتور 1

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 12V4000 DS2250

DIESEL GENERATOR SET MTU 20V4000 DS4000

DIESEL GENERATOR SET MTU 12V4000 DS1750

DIESEL GENERATOR SET MTU 16V4000 DS2250

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 16V4000 DS2500

DIESEL GENERATOR SET MTU 20V4000 DS3600

DIESEL GENERATOR SET MTU 20V4000 DS3300

DIESEL GENERATOR SET DG00660D5

DIESEL GENERATOR SET MTU 10V1600 DS500

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET MTU 12V1600 DS660

Volvo TAD732GE diesel engine Leroy Somer LSA 46.2 M3 alternator Standard Generator Features

Standby Rating 220/ / / / / /

20' STANDARD CONTAINER MTU 16V2000 DS: kva MTU 18V2000 DS: kva

Volvo TAD1344GE diesel engine Leroy Somer LSA 47.2 S4 alternator Standard Generator Features

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

ژنراتور : Alte Mecc موتور دیزل : Deutz KVA KW KVA KW

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

Perkins 1103A-33G diesel engine Newage/Stamford BCI184G alternator Standard Generator Features

Perkins 1104C-44TAG2 diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

Perkins 1006TAG diesel engine Newage/Stamford UCI274E alternator Standard Generator Features

Perkins 403D-15G diesel engine Newage/Stamford BCI164C alternator Standard Generator Features

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

Volvo TAD531GE diesel engine Newage/Stamford UCI274C alternator Standard Generator Features

ژنراتور : Meccalte موتور دیزل : IVECO KW KVA KW KVA

60 Hz FEATURES. Exclusively from your Caterpillar dealer

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

G80U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

RENTAL DIESEL GENERATOR SET

Perkins 4016TAG1A diesel engine Stamford PI734E alternator Standard Generator Features

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

Industrial Diesel Generator Set KD3500-F 50 Hz Fuel Consumption Optimized

Perkins 2806A-E18TAG2 diesel engine Newage/Stamford HCI544F alternator Standard Generator Features

STANDBY 2480 ekw 3100 kva 50 Hz 1500 rpm 400 Volts

Perkins 2506A-E15TAG2 diesel engine Newage/Stamford HCI544D alternator Standard Generator Features

Model DKAC 60 Hz EPA Emissions

Perkins TWG2A diesel engine Newage/Stamford PI734B alternator Standard Generator Features

Model NA 2 L

Diesel Generator Set Model DGDB 60 Hz

Industrial Diesel Generator Set KD1250-UE 60 Hz - Emission Optimized EPA Tier 2 Certified

Perkins 2206A-E13TAG2 diesel engine Newage/Stamford HCI444E alternator Standard Generator Features

CMEC POWER GENERATION. PRIME 800 ekw 1000 kva 50 Hz 1500 rpm 400 Volts DIESEL GENERATOR SET WHERE THE WORLD TURNS FOR POWER FEATURES

Perkins TAG3A diesel engine Newage/Stamford PI734E alternator Standard Generator Features. Optional Features ISO ISO 9001:2000

Generator set data sheet Prime. Fuel consumption. Engine Standby rating Prime rating Continuous rating. Fuel flow

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

2500 Prime 2200 Continuous

Gaseous Fuel Generator Set Model GFDA

Model MP150 W W

Generator Set Specifications 100 ekw (125 kva)

2500 Prime 2100 Continuous Emissions level: EPA NSPS Stationary Emergency Tier 2

Industrial Diesel Generator Set KD2500-F 50 Hz Fuel Consumption Optimized

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

Industrial Diesel Generator Set KD1100-F 50 Hz Fuel Consumption Optimized

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

Rating Definitions and Conditions

Model DFHD 60 Hz EPA Emissions

PRIME 2260 ekw 2825 kva 50 Hz 1500 rpm Volts

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 400 Volts

Generator Set Configurations Low Fuel Consumption, EU Stage IIIA Nonroad Emission Standards, China Nonroad III Emission Standards

Engine Performance 1500 RPM

Generator Set Specifications 60 ekw (75 kva)

Diesel Generator Set Model DFHB 60 Hz

Dry Weigt Length Width kg mm mm. K.U.N.Z. Handels-&Produktions GmbH

Spark-Ignited Generator Set Model GGLA 60 Hz

Industrial Diesel Generator Set KD1750-UF 60 Hz Fuel Consumption Optimized

Model: TD200 UCI274J / / /

Rating Definitions and Conditions

Diesel Generator Set Model DFBF 60 Hz

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

Standby kw Prime kw

Rental Power 800 kw. Specification sheet. Description. Features. Options

KTA50 Land Based Drilling Power Modules

Spark-Ignited Generator Set Model GGFD 60 Hz

Diesel Generator Set Model DFCE 60 Hz

Bore mm 4.35 in Displacement 8.8 L 535 in³ Stroke mm 4.5 in Compression Ratio 10.1:1

Transcription:

ژنراتور : MTU موتور ديزل : MTU Standby Prime KVA KW KVA KW 1276 1020 1160 928 ديزل ژنراتور ABYARAN Copyright 2014 - All Rights Reserved 1

موتور ديزل توليد كننده Manufacturer MTU مدل Model 18V2000G65TB تعداد سيلندر ها Number of cylinders 18 ا رايش سيلندر ها Cylinder arrangement vertical جا به جايي Displacement, Liters 1.99 قطر سيلندر كورس پيستون 130 150 Bore Stroke, mm نسبت تراكم Compression Ratio 16:1 سيستم تنفس Aspirating m3/min 69 قدرت ناخالص موتور Gross engine power, kwb 928 Fuel Consumption At 100% of power rating L/hr Fuel Consumption At 75% of power rating L/hr Fuel Consumption At 50% of power rating L/hr Exhaust gas temp.(after turbo), C 243 مصرف سوخت در %100 بار 181 مصرف سوخت در %75 بار 123 مصرف سوخت در %50 بار 555 دماي گاز خروجي از اگزوز ABYARAN Copyright 2014 - All Rights Reserved 2

ژنراتور توليد كننده Manufacturer MTU مدل Model 740RSL7076 توان standby در ولتاژ نامي Standby power at rated voltage,kva 1276 ضريب قدرت Power factor 0.8 فاز Phase 3 فركانس Frequency, Hz 50 سرعت Speed, Rpm 1500 ولتاژ Voltage, V 380 رگولاتور ولتاژ Voltage Regulator Three phase sensing تنظيم ولتاژ ±0.25% % Regulation, Voltage حداكثر سرعت مجاز Over speed, Rpm 2250 كلاس عايق Insulation class H اتصال Connection 6 LEAD HI WYE كلاس حفاظتي Protection class IP23 ABYARAN Copyright 2014 - All Rights Reserved 3

DIESEL GENERATOR SET WATER CHARGE-AIR COOLING 1160kVA/50 Hz/Prime Power (Fuel Consumption Optimized) 380-415V Optional equipment shown. Standard equipment may vary. BENEFITS // Low installation costs // Best fuel consumption values // Long maintenance intervals // Best-in-class reliability and availability // Lifting vertically or with diagonal pull // Compact design SYSTEM RATINGS ➀ Prime Power MTU 18V2000 DS1290 MTU 18V2000 DS1290 MTU 18V2000 DS1290 Voltage (L-L) 380V 400V 415V Phase 3 3 3 PF 0.8 0.8 0.8 Hz 50 50 50 kw 928 928 928 kva 1160 1160 1160 Amps 1762 1674 1614 Generator model 740RSL7076 740RSL7076 740RSL7076 Temp rise 125 C/40 C 125 C/40 C 125 C/40 C Connection 6 LEAD HI WYE 6 LEAD HI WYE 6 LEAD HI WYE ➀ Power available up to 40 C/400 m

2 / / / 50 Hz 1160 kva CERTIFICATIONS AND STANDARDS // Engine-generator set is designed and manufactured in facilities certified to standards ISO 9001:2008 and ISO 14001:2004 // Performance Assurance Certification (PAC) - Engine-generator set tested according to ISO 8528-5 for transient response - Verified product design, quality and performance integrity - All engine systems are type and factory tested // Power Rating - Permissible average power output during 24 hours of operation up to 75% STANDARD EQUIPMENT ➀ // Engine Air filters Oil pump for draining Full flow oil filters Closed crankcase ventilation Jacket water pump Thermostats Exhaust manifold dry Belt driven radiator fan Electric starting motor 24V Governor electronic isochronous Base formed steel SAE flywheel & bell housing Charging alternator Flexible fuel connectors Flexible exhaust connection // Generator NEMA MG1, IEEE and ANSI standards compliance for temperature rise and motor VDE 0530, IEC 60034-1, BS4999, BS5000, CSA22.2-100, AS 1366 Sustained short circuit current of up to 250% of the rated current for up to 10 seconds Self-ventilated and drip-proof IP23 Superior voltage waveform Digital, volts-per-hertz regulator No load to full load regulation Brushless alternator with brushless pilot exciter 4 Pole, rotating fi eld 125 C maximum prime temperature rise Heavy duty shielded ball bearings with a minimum B-10 life of 40,000 hrs Flexible coupling Full amortisseur windings 3-phase voltage sensing ±0.25% voltage regulation 100% of rated load one step according to NFPA 110 3% maximum harmonic content ➀ Represents standard product only. Consult Factory/MTU Onsite Energy distributor for additional configurations.

3 / / / 50 Hz 1160 kva STANDARD FEATURES ➀ // The engine-generator set complies to G3 // Engine generator set tested according to ISO 8528-5 for transient response // Accepts rated load in one step as per NFPA 110 // All engine-generator sets are type and factory tested // MTU Onsite Energy is a single source supplier // Global product support // 18V2000 diesel engine (35,82 Liter (2186 cu inch) displacement; 4-stroke) // Engine-generator resiliently mounted // Complete range of accessories // Brushless, rotating fi eld generator (PMG excitation; 250% short circuit capability; 2/3 pitch stator windings) // Complete system metering // LCD display APPLICATION DATA // Engine Manufacturer MTU Model 18V2000G65TB Type 4-Stroke Arrangement 18-V Displacement/cylinder: l (cu inch) 1.99 (121) Bore: mm (inch) 130 (5.1) Stroke: mm (inch) 150 (5.9) Compression ratio 16:1 Rated speed rpm 1500 Engine governor Electronic isochronous Max power: kwm (bhp) 1000 (1341) Speed regulation ±0.25% Air filter Dry // Lube Oil Capacity Total oil system: l (gal) 130 (34) // Electrical Electric Volts DC 24 Cold cranking amps under -17.8 C (0 F) 1000 // Fuel System gal/hr l/hr g/kwh At 100% of power rating: 64 243 202 At 75% of power rating: 48 181 200 At 50% of power rating: 32 123 204 // Cooling/Radiator System Water pump capacity: l/min (gpm) 667 (176) Heat rejection to coolant: kw (BTUM) 425 (24,169) Heat rejection to after cooler: kw (BTUM) 215 (12,227) Heat radiated to ambient: kw (BTUM) 50 (2,843) Engine coolant capacity: l (gal) 140 (37) // Air Requirements ➂ Aspirating: m 3 /min (SCFM) 69 (2434) // Exhaust System Gas temp. (stack): C ( F) 555 (1031) Gas volume flow temp: m 3 /min (SCFM) 198 (6991) Maximum allowable back pressure: kpa 8.5 Fuel supply connection size M22x1,5-60 /Male Fuel return connection size M12x1,5-60 /Male Maximum fuel lift: m (ft) 5 (16) Recommended fuel see MTU fluids & lubrication spec. Total fuel flow: l/hr (gal/hr) 600 (159) ➀ Represents standard product only. Consult Factory/MTU Onsite Energy distributor for additional configurations. ➁ Values in accordance with ISO 3046-1. Conversion calculated with fuel density of 0.83 g/ml. ➂ Air density = 1.184 kg/m 3 (0.0739 lbm/ft 3 )

4 / / / 50 Hz 1160 kva WEIGHTS AND DIMENSIONS Drawing above for illustration purposes only, based an standard open power 400 Volt engine-generator set. Lengths may vary with other voltages. Do not use for installation design. See website for unit specific template drawings. System Dimensions (L x W x H) Weight (dry/less tank) Open Power Unit (OPU) 4325 x 1750 x 1821 mm (170.3 x 69 x 71.7 inch) 6478 kg (14,283 lbs) Weights and dimensions are based on open power units and are estimates only. Consult the factory for accurate weights and dimensions for your specific engine-generator set. SOUND DATA // Consult your local MTU Onsite Energy distributor for sound data. EMISSIONS DATA // Consult your local MTU Onsite Energy distributor for emissions data. RATING DEFINITIONS AND CONDITIONS // Prime power ratings apply to installations where utility power is unavailable or unreliable. At varying load, the number of generator set operating hours is unlimited. A 10% overload capacity is available for one hour in twelve. Ratings are in accordance with ISO 8528-1, ISO 3046-1, BS 5514 and AS 2789. Average load factor: 75%. // Deration factor: Altitude: Consult your local MTU Onsite Energy distributor for altitude derations. Temperature: Consult your local MTU Onsite Energy distributor for temperature derations. Subject to change. 3236731 Edition 02/14 ENC 2014-07. Materials and specifi cations subject to change without notice. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com