Compact Circuit Protector

Similar documents
BUSSMANN. Next generation Compact Circuit Protector (cat. no. CCP2) SERIES. For use with Class CC, Supplemental and IEC 10x38 mm fuses

Compact Circuit Protector

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP) 1-, 2- and 3-pole Class CC, Midget, 10x38mm

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

Compact Circuit Protector (CCP)

BUSSMANN. CUBEFuse Compact Circuit Protector Base (CCPB) SERIES. Technical Data Effective April 2017 Supersedes April 2016

CUBEFuse. CUBEFuse catalog numbers (amps)

Effective December 2015 Supersedes September 2013

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

CHCC_ (Class CC) CHM_ (UL midget/iec 10x38) CHPV_ (13/32 x 1-1/2 and 10x38 photovoltaic)

Up to 60 A Class R 250 V and 600 V ferrule power distribution fuse blocks

Section Contents. Disconnect Switches

footprint of traditional fusible switches

Bussmann Open and Enclosed Rotary Disconnect Switches. Exceptional Breadth and Availability for Your Application

Bussmann series Quik-Spec Power Module Switch elevator disconnect

UL Recognized power distribution blocks

Low-Peak LPJ Class J 600Vac/300Vdc, 1-60A, dual element, time-delay fuses

Fusetron FRN-R Class RK5 250Vac/125Vdc A, dual element, time-delay fuses

Electric vehicle auxiliary fuses 500 Vdc, A

BH-1 modular fuse blocks, 700 V, 400 A

Class J modular ferrule and knifeblade fuse blocks

BUSSMANN. LIMITRON FNQ-R Class CC 600Vac, A, time-delay fuses SERIES. Technical Data Carton quantity: Catalog symbol: Dimensions - in:

Class R 250V and 600V modular ferrule and knifeblade fuse blocks

FRNR A 250V TD Class RK5 Dual Elem Fuse-Fusetron

Application note Compact Circuit Protector (CCP2) Smaller, better... the Power of Space

6.3 mm reverse quick connect

Compact Circuit Protector (CCP) Application Note

Quik-Spec Coordination Panelboard A fusible panelboards

BUSSMANN. Pre-production and sample electric vehicle power fuses 500 Vdc, A SERIES. Technical Data Effective December 2018.

up to 30A limited by conductor size Operating and storage temperature:

LKN A 250V Super-Lag Fuse Link. Features amperage rating 200 class Voltage Rating 250. Long Description. Manufacturer Information

Bussmann series Quik-Spec Coordination Panelboard

Specification made simple for selective coordination in a compact size

The easiest and fastest way to select and specify the right control circuit fuse

Low-Peak 600V Class RK1

LPCC3 3A 600V TD Class CC Low Peak Fuse. Features amperage rating. Dimensions and Weight. Long Description. Manufacturer Information

Quik-Spec Coordination Panelboard A fusible panelboards

Volts: 600V Amps: up to 30A limited by conductor size Withstand: 200kA RMS Sym. Operating and storage temperature:

Quik-Spec Electrical Gear

LPSRK30SP 30A 600V TD Dual Elem Class RK1 Low Peak Fuse

Quik-Spec Coordination Panelboard Specifications

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

N0N A 250V One-Time Class H Fuse

LPSRK100SP 100A 600V TD Dual Elem Class RK1 Low Peak Fuse

Complete and reliable solar circuit protection

Now - Up To 400A Mains!

Quik-Spec. Section Contents

Load Break Disconnect Switches FSLBS

Selection and application guide

Quik-Spec Coordination Panelboard

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

PT Medium voltage fuses for potential and small power transformers

Product Specification Sheet #3LD2.1

BUSSMANN. 8.3kV E-Rated SERIES. Medium voltage fuses for feeder circuit, switchgear and transformer. protection. Technical Data 10352

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Fast-acting supplemental fuse. For superior protection, Bussmann recommends upgrading to Low-Peak Class CC fuses. See data sheet # 1023.

UL 508 Non-Fusible Disconnect Switches

SPEEDFAX TM 2011 Disconnect Switches Contents

CCP2-FLR1-21_ flange-rod operating mechanism

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Non-fusible. Non-fusible disconnect switches 16A 3150A, 600VAC A, 1000VDC. International acceptance. Disconnect switches.

UL 508 Non-Fusible Disconnect Switches

Compact Modular Fuse Holders With the Industry s Best Ratings Products for PV, IEC and UL Applications

FUSIBLE DISCONNECT SWITCHES

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Single & Three-Phase Soft Starters

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Rotary Disconnect Switches, Bulletin 194R

SIRCO UL98 Load break switches standards UL and CSA 100 to 1200 A

1489-M Circuit Breakers

Cat. No. 194R-J Note: Your order must include 1) Cat. No. of disconnect switch, 2) shaft, 3) handle, and 4) any accessories.

for Non-Fusible Disconnect Switches

AF40... AF96 3-pole contactors Technical data

SIRCO UL98 Non-fusible switches standards UL and CSA 100 to 1200 A

NH DIN Dual Indication Fuse Links Class am, 690Vac, 6 to 500 Amps, Sizes 000 to 3 NH Series

Control Circuit Protection

UL Enclosed Disconnect Switches (Fused and Non-Fused)

Low voltage, branch circuit fuses

Series L9 UL-489 Miniature Circuit Breakers

LOW-PEAK Time-Delay Fuses KRP-C Class L 600 Volt A

Certifications UL Listed (File No. E 14841, Guide NLRV; File No. E 47426, Guide WHTY) CSA Certified (File No. LR1234) CE

Products for enhancing electrical safety and reliability

SAV Electronic Valve Actuator

Enclosed Rotary Switch Product Specification Sheets Table of Contents

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

FAMILY. 1-Phase 1 Up to 25A Up to 40A Up to 80A Up to 600VAC 3-Phase, 2 leg 1 No Up to 33A Up to 80A Gang 2 units

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

Big performance in a small package

Installation Instructions

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

Disconnect switches Non-fusible Fusible Enclosed

Contents. Volume 5 Motor Control and Protection CA E December

Non-fusable disconnect switches standards UL and CSA from 16 to 100 A

Transcription:

Technical Data 10801 Supersedes August 018 BUSSMANN SERIES Compact Circuit Protector (cat. no. CCP) Contents Page 011/65/EU and specifications.... -3 Catalog numbers.... 4 Conductor information and available fuses.... 5 Dimensions.... 5-7 Accessories Selector and pistol handles, and shafts.... 8 Multi-wire lug kits.... 9 Auxiliary contacts... 10 PLC fuse monitor...11-1 How to order 30-60 A switches....13-16 100 A switches...17-0 Motor fuse sizing table.... 1 CCP switch CCP right front rotary switch CCP left front rotary switch CCP right side rotary switch CCP left side rotary switch

Technical Data 10801 Compact Circuit Protector (CCP) Catalog symbols for 30, 60 and 100 A switches Symbol CCP-(pole)-(30/60/100)CF CCPR-(pole)-(30/60/100)CF CCPRL-(pole)-(30/60/100)CF CCPS-(pole)-(30/60/100)CF CCPSL-(pole)-(30/60/100)CF Switch only Right front rotary, clockwise operated switch Left front rotary, clockwise operated switch Right side rotary, clockwise operated switch Left side rotary, counterclockwise operated switch The revolutionary, next generation Bussmann series Compact Circuit Protector (CCP) is a fused UL 98 branch circuit disconnect switch utilizing the UL Class CF time-delay or fast-acting CUBEFuse. With /3 the footprint of a traditional fusible solution, these switches provide a high 00 ka SCCR to help improve panel and assembly SCCR. The switch-only versions of the 30, 60 and 100 A disconnects are direct, drop-in replacements for the earlier models (noted by a catalog number starting CCP- ). The auxiliary contacts and PLC remote fuse indicator are backwards compatible. The multi-wire lug kits and terminal shrouds are not. The 35 mm DIN-Rail mount CCP is available in a variety of 30, 60 and 100 amp configurations to meet many application needs including rotary operation. Application flexibility is extended with an optional multi-wire lug kit, featuring finger-safe shrouds, that provides three (30 and 60 A switches) and six (100 A switches) additional wire ports on each pole for power distribution applications. Other accessories include a PLC fuse monitor for open fuse indication and NO/NC auxiliary contacts that easily integrated into many monitoring systems. Front and side rotary operated versions are easily applied for through-the-door or through the left or right side operation to enhance safety. Ratings Volts 347 Vac (1-pole switches) 600 Vac (- and 3-pole switches) 15 Vdc* Amps 30 A 60 A 100 A SCCR 00 ka RMS Sym. 100 ka DC Poles 1-, - and 3-poles catalog number dependent * Switch amp rating and installed fuse amp rating dependent, see catalog number table for details. Agency information UL 98 Listed, Guide WHTY, File E30370 culus to Canadian Standard. No. 4-04, Guide WHTY7, File 30370 RoHS compliant CE Conductors/terminals 75 C Cu, see conductor tables for size, type and torque information Box lug, single/dual conductor Fork terminal suitable for line, load or accessory connection, max. 30 A suitable for use with: 10-4 screw for 30 and 60 A switches 1/4-8 screw for 100 A switches Multi-wire lug kit see accessories for details Storage and operating temperature - 0 C to 75 C (-4 F to 167 F)* * For fuse performance under or above 5 C, consult fuse performance derating charts in the Bussmann Division publication no. 300, titled Selecting Protective Devices (SPD) Lockout/tagout provisions 1/4 lock, direct use on switches without rotary mechanisms requires a lock with a straight shank of sufficient length to engage all poles Minimum enclosure size 30 and 60 A switch 10 x 8 x 6 (54 x 03 x 15 mm) 100 A switch, 14 x 1 x 6 (356 x 305 x 15 mm) Mounting 35 mm DIN-Rail Local open fuse indication minimum voltage** 90 Vac for AC switches 1 Vdc for DC switches ** Open fuse indication requires an open fuse to be in the CCP and the switch in the ON position. Accessories Multi-wire lug kit with terminal shrouds Selector and pistol handles for use with rotary operated switches 8 mm shafts for use with selector and pistol handles Auxiliary contacts PLC remote fuse indicator Carton quantity and shipping weight Item Switches Poles Weight lbs (kg) 30 and 60 amp switches Switch only 1 3.8 (1.7) -pole 1.3 (0.6) Switch with side rotary mechanism 3-pole 1.6 (0.7) -pole 1.3 (0.6) Switch with front rotary mechanism 3-pole 1.6 (0.7) 100 amp switches Switch only 6 3.1 (1.4) -pole 1.7 (0.8) Switch with side rotary mechanism 3-pole.3 (1.0) -pole 1.7 (0.8) Switch with front rotary mechanism 3-pole.3 (1.0)

Compact Circuit Protector (CCP) Technical Data 10801 Features Uses UL Class CF time-delay or fast-acting CUBEFuse with Class J electrical performance Extremely compact design at 5.4 mm (1 inch) wide per pole Amp rating rejecting disconnects will not accept a CUBEFuse amp rating greater than switch rating High 00 ka short-circuit current rating Disconnect rated to provide means for load isolation Full voltage rated at 347 Vac (1-pole switches) and 600 Vac (- and 3-pole switches) 15 Vdc* rated to meet specialized applications UL 98 Listed and suitable for branch circuit disconnect and branch circuit protection 1-, - and 3-pole versions are horsepower rated Open fuse indication: Local fuse indication light on each pole standard Optional PLC fuse monitor for wired remote open fuse indication by signaling a PLC and open a contactor to de-energize all phases, if required Additional open fuse indication can be provided by the time-delay CUBEFuse (6 to 100 A) IP0 finger-safe construction with 10 AWG (6 mm ) wire or larger Built-in switch interlock prohibits removing the fuse under load Padlockable for lockout/tagout procedures with a 1/4 lock Rotary operated versions provide for through-the-door and through-the-side operation flexibility and enhanced safety with: Right front switch operation Left front switch operation Right side switch operation Left side switch operation Optional selector and pistol handles available for use with rotary operated versions Multi-wire lug kit with terminal shrouds allows for power distribution to multiple loads. Each lug has three (30 and 60 A switches) or six (100 A switches) ports rated for single and dual wires. (See lug kit in accessories for conductor and torque details.) Right front rotary operated CCP switch with PLC fuse monitor. Rotary operating switch versions * Switch amp rating and installed fuse amp rating dependent, see catalog number table for details. Open fuse indicating light Switch handle (ganged on - and 3-pole versions) Fuse holder Left front rotary switch Clockwise operating handles Right front rotary switch Clockwise operating handles Fork terminal 1/4 Lockout/ tagout provision Box lug terminal Left side rotary switch Counterclockwise operating handles Right side rotary switch Clockwise operating handles 3

Technical Data 10801 Compact Circuit Protector (CCP) 30, 60 and 100 A switch catalog numbers Catalog no. Poles Volts SCCR 30 amp switches CCP-1-30CF 1 347 Vac/15 Vdc Max Hp rating (Vac) 10 40 480 600 1.5 CCP--30CF Switch only 600 Vac/15 Vdc 3 CCP-3-30CF 3 600 Vac 5 15 10 CCPR--30CF 600 Vac/15 Vdc 3 Right front rotary, clockwise operated switch CCPR-3-30CF 3 600 Vac 5 15 10 00 ka AC CCPRL--30CF 600 Vac/15 Vdc 3 Left front rotary, clockwise operated switch 100 ka DC CCPRL-3-30CF 3 600 Vac 5 15 10 CCPS--30CF 600 Vac/15 Vdc 3 Right side rotary, clockwise operated switch CCPS-3-30CF 3 600 Vac 5 15 10 CCPSL--30CF 600 Vac/15 Vdc 3 Left side rotary, counterclockwise operated switch CCPSL-3-30CF 3 600 Vac 5 15 10 60 amp switches CCP-1-60CF 1 347 Vac/15 Vdc* 3 CCP--60CF Switch only 600 Vac/15 Vdc* 7.5 CCP-3-60CF 3 600 Vac 7.5 0 10 CCPR--60CF 600 Vac/15 Vdc* 7.5 Right front rotary, clockwise operated switch CCPR-3-60CF 3 600 Vac 7.5 0 10 00 ka AC CCPRL--60CF 600 Vac/15 Vdc* 7.5 Left front rotary, clockwise operated switch 100 ka DC CCPRL-3-60CF 3 600 Vac 7.5 0 10 CCPS--60CF 600 Vac/15 Vdc* 7.5 Right side rotary, clockwise operated switch CCPS-3-60CF 3 600 Vac 7.5 0 10 CCPSL--60CF 600 Vac/15 Vdc* 7.5 Left side rotary, counterclockwise operated switch CCPSL-3-60CF 3 600 Vac 7.5 0 10 100 amp switches CCP-1-100CF 1 347 Vac/15 Vdc** 5 CCP--100CF Switch only 600 Vac/15 Vdc** 10 CCP-3-100CF 3 600 Vac 0 50 40 CCPR--100CF 600 Vac/15 Vdc** 10 Right front rotary, clockwise operated switch CCPR-3-100CF 3 600 Vac 0 50 40 00 ka AC CCPRL--100CF 600 Vac/15 Vdc** 10 Left front rotary, clockwise operated switch 100 ka DC CCPRL-3-100CF 3 600 Vac 0 50 40 CCPS--100CF 600 Vac/15 Vdc** 10 Right side rotary, clockwise operated switch CCPS-3-100CF 3 600 Vac 0 50 40 CCPSL--100CF 600 Vac/15 Vdc** 10 Left side rotary, counterclockwise operated switch CCPSL-3-100CF 3 600 Vac 0 50 40 * 15 Vdc for installed fuse amp ratings up to 40 A. 4 Vdc for installed fuse amp ratings from 45 to 60 A. ** 15 Vdc for installed fuse amp ratings up to 80 A, 4 Vdc for installed fuse amp ratings from 90 to 100 A. 4

Compact Circuit Protector (CCP) Technical Data 10801 Box lug terminal conductor data Wire type AWG range Class Quantity 30 and 60 A switches 75 C Cu Torque N m (lb-in) 4-6 Stranded, Class B 3.95 (35) to K Single 8-18.6 (0) 6-8 10-18 100 A switches 75 C Cu Stranded, Class B/C Stranded, Class K Stranded, Class B to K Dual 3.39 (30).6 (0) 10-18 Solid Single/dual.6 (0) 4-18 Stranded, UL ferrule, Single 6-18 Class B/C Twin 4-18 Stranded, UL ferrule, Single 6-18 Class K Twin 1-18 3.39 (30).8 (5).6 (0) 10.8 (5) 8 Single 4.5 (40 Stranded, Class B/C 4-6 5.08 (45) 1-3 6.1 (55) 4-1 Dual 5.08 (45) 1-18.6 (0) 10 Single 3.95 (35) 1-8 Stranded, UL ferrule, Class B/C 4.5 (40) 10-18.6 (0) Twin 6-9.8 (5) 10-18 Solid Single/Dual.6 (0) 8-18.6 (0) Single 1-7 Class K 3.39 (30) 3-10 Dual 5.08 (45) 8-18.6 (0) Single 1-7 Class K, UL ferrule 3.39 (30) 6-18 Twin.6 (0) Two stranded conductors placed in one UL Listed twin ferrule. Lineside and loadside fork terminal Fork terminal suitable for line, load or accessory connection, max. 30 A suitable for use with: 10-4 screw for 30 and 60 A switches 1/4-8 screw for 100 A switches Available Bussmann series fuses UL fuse class Type/description Volts Data sheet no. CF Indicating time-delay, Low- Peak CUBEFuse (6-100 A) Non-indicating time-delay, Low-Peak CUBEFuse (1-100 A) Non-indicating fast-acting CUBEFuse (1-100 A) 600 Vac/ 300 Vdc 9000 600 Vac/dc 147 Dimensions mm (in) Switch (shown with optional terminal shrouds) 76 50.0 5 1.0 75 75 30 and 60 amp switches 75 50.0 5 1.0 100 amp switches 114 4.5 30A Fuse 60A Fuse 148 5.8 40 9.5 06 8.1 83 3.3 89 3.5 100 3.9 5

Technical Data 10801 Compact Circuit Protector (CCP) Left front rotary switches (shown with optional terminal shrouds) 114 4.5 114 4.5 06 8.1 99 3.9 101 4.0 76 Right front rotary switches (shown with optional terminal shrouds) 83 3.3 76 30 A Fuse 99 3.9 101 4.0 99 3.9 30 A Fuse 60 A Fuse 30 and 60 amp switches 101 4.0 148 5.8 101 4.0 76 40 9.5 100 106 3.9 4. 100 amp switches 6 89 3.5 60 A Fuse 30 and 60 amp switches 76 83 3.3 99 3.9 89 3.5 06 8.1 148 5.8 40 9.5 100 106 3.9 4. 100 amp switches

Compact Circuit Protector (CCP) Technical Data 10801 Left side rotary switches (shown with optional terminal shrouds) Right side rotary switches (shown with optional terminal shrouds) 114 4.5 06 8.1 114 4.5 06 8.1 101 4.0 75 30 A Fuse 83 3.3 76 101 4.0 75 30 A Fuse 83 3.3 75 89 3.5 75 89 3.5 60 A Fuse 60 A Fuse 30 and 60 amp switches 30 and 60 amp switches 101 4.0 148 76 148 76 5.8 40 5.8 40 9.5 9.5 101 4.0 100 3.9 100 3.9 100 amp switches 100 amp switches 7

Technical Data 10801 Compact Circuit Protector (CCP) Selector and pistol handles Catalog symbol CCP-H4X-_ Selector and pistol handles for use with any - and 3-pole CCP rotary operated switch. Both selector and pistol handles are available in black/grey and red/yellow colors and clockwise/counterclockwise operating modes. The application of clockwise and counterclockwise operation is dependent upon the CCP rotary switch configuration. Installation requires an 8 mm shaft (ordered separately). Each handle is rated NEMA 4X and capable of accepting up to three (3) 1/4 locks for lockout/tagout in the OFF position. They can also be field configured for lock-on. Agency information UL Listed, Guide DIHS/DIHS7, File E140305 NEMA 4X rating RoHS compliant CE Storage and operating temperature -0 C to 75 C (-4 F to 167 F) Packaging Each handle is packaged individually as a kit Selector handles Pistol handles In application, only the clockwise operating handles in combination with either the left front or right front rotary switches provide a door interlock means to ensure the enclosure door remains shut during lockout/tagout or lock-on. Both clockwise and counterclockwise operating handles when mounted on the enclosure s left or right side do NOT provide a door interlock means. See the catalog number table below for applicable rotary switch, handle and shaft combinations. Carton quantity and shipping weight Handle style Qty. Weight lbs (kg) All selector handles 1.1 (0.5) 1 All pistol handles 1.3 (0.59) Handle shafts Catalog symbol CCP-SH1-_ Eight millimeter square shafts available in 90 and 490 millimeter (11.5 and 19.3 inch) lengths. Shafts are indexed to ensure handle/ switch orientation for correct operation. Shafts are to be cut to length when installed. Packaging Each shaft is packaged separately Clockwise CCP-H4X-B1 CCP-H4X-R1 Counterclockwise CCP-H4X-B1L CCP-H4X-R1L Handle shafts Clockwise CCP-H4X-B CCP-H4X-R Counterclockwise CCP-H4X-BL CCP-H4X-RL For these switch catalog numbers CCPR-(pole)-30CF CCPR-(pole)-60CF CCPR-(pole)-100CF CCPRL-(pole)-30CF CCPRL-(pole)-60CF CCPRL-(pole)-100CF CCPS-(pole)-30CF CCPS-(pole)-60CF CCPS-(pole)-100CF /operation Right front rotary, clockwise Left front rotary, clockwise Right side rotary, clockwise Order these handle catalog numbers (description) CCP-H4X-B1 (selector, black/grey) CCP-H4X-R1(selector, red/yellow) CCP-H4X-B (pistol, black/grey) CCP-H4X-R (pistol, red/yellow) Order either shaft catalog number CCP-SH1-90 (11.5 /90 mm) CCP-SH1-490 (19.3 /490 mm) CCPSL-(pole)-30CF CCPSL-(pole)-60CF CCPSL-(pole)-100CF Left side rotary, counterclockwise CCP-H4X-B1L (selector, black/grey) CCP-H4X-R1L (selector, red/yellow) CCP-H4X-BL (pistol, black/grey) CCP-H4X-RL (pistol, red/yellow) 8

Compact Circuit Protector (CCP) Technical Data 10801 Multi-wire lug kits Catalog numbers CCP-MW1-3 (for 30 and 60 A switches only) CCP-MW-1-6 (for 100 A switches only) The multi-wire lug kit permits expanding each box lug terminal on the switch into a three-port (30 and 60 A switches) or six-port (100 A switches) terminal for power distribution applications. Each multi-wire lug kit comes with three lugs and three terminal shrouds. Shrouds provide finger-safe protection when properly installed. Lugs may be mounted on either the loadside or lineside to meet various application needs. Ports on any one lug accept any conductor combination listed, e.g., one of the ports may have dual 14 AWG wires and the other two ports single 10 AWG wires. Ratings Volts 600 V Amps 60 A max (CCP-MW1-3) 100 A max (CCP-MW1-6) SCCR 00 ka Agency information UL Recognized RoHS compliant Storage and operating temperature - 0 C to 75 C (-4 F to 167 F) Multi-wire lug conductor information 75 C Cu/AL AWG size and quantity per port - see table below Type Cu/Al Cu AWG range Class Quantity Torque N m (lb-in) 4-6 3.95 (35) Stranded, Class B/C Single 8.8 (5) 10-14 Stranded, Class B/C Single/dual*.6 (0) 10-14 Solid Single.6 (0) 8.8 (5) UL ferrule, Class B to K Single/twin 10-14.6 (0) Installed on CCP-3-xx Multi-wire lugs mount in switch box lug terminals to provide three or six additional wire ports per pole. Lugs can be mounted on the switch lineside or loadside. Each multi-wire lug kit comes with three lugs and three shrouds. Wire insulation strip lengths 1/8 Allen head screw 1 = 11/16 = 1-1/8 3 = 1-9/16 Strip back wire insulation to the lengths as indicated in the illustration above and the table below. Lug port Strip wire insulation back (inch) 1 11/16 1-1/8 3 1-9/16 1/8 Allen head screw 1 = 11/16 = 1-1/8 3 = 1-9/16 * Dual wire to be same size and type. Two stranded conductors placed in one UL Listed twin ferrule. CCP box lug torque for multi-wire lugs 60 A lug, 4.5 N m (40 lb-in) 100 A lug, 5.09 N m (45 lb-in) Carton quantity and shipping weight Catalog no. /application Qty. Weight lbs (kg) CCP-MW1-3 Lug kit, 30/60 A switches 3 lugs and 0.36 (0.16) CCP-MW1-6 Lug kit, 100 A switches 3 shrouds 0.49 (0.) CCP-TS1-3 Shrouds, 30/60 A switches 0.17 (0.077) 3 shrouds CCP-TS1-6 Shrouds, 100 A switches 0. (0.09) Wiring versatility is provided by single/dual rated box lug terminals on the switch, or by the three-port or six-port multi-wire lug kits that are also single/dual wire rated. 9

Technical Data 10801 Compact Circuit Protector (CCP) Auxiliary contacts Catalog numbers CCP-AUX (30 and 60 A switches) CCP-AUX-100 (100 A switches) NO+NC contact output to indicate the switching mechanism status on the CCP. A single unit can be mounted on any 1-, - or 3-pole CUBEFuse CCP switch and the right front/right side rotary operated switches. Installed on a CCP-3-xx Note: CCP-AUX and CCP-AUX-100 CANNOT be mounted on the left front and left side rotary operated versions. Ratings Amps up to 5 A Volts up to 40 Vac NC/NO contacts are closed/open when the CCP switch is in the ON position (closed) Catalog no. Switch Max per CCP* Signal output CCP-AUX CCP-AUX-100 30/60 A only 100 A only Auxiliary contacts NO+NC for switch status 1 per CCP (1-, - or 3-pole) 5 A / 40 Vac Dimensions in 1.8 * The CCP-AUX CANNOT be mounted on the left front and left side rotary operated versions. De-energize all circuits and follow all prescribed safety procedures before installing or removing the auxiliary contact device. Agency information UL 98 Recognized, Guide WHTY, File E155130.6 33 NO STRIP 34 NO 1.9 curus to Canadian Standard. No. 4-04 IEC 60947-5-1 AC-15 (catalog no. CCP-AUX)) 41 NC 4 NC IP0 finger-safe in installed state RoHS compliant CE CCP-AUX 3.7.190 0.3 Wiring 0-16 AWG (0.5 to 1.5 mm ) wire Torque 0.56 N m (5 lb-in) Use only 75 C Cu wire 1.8 Packaging CCP-AUX and CCP-AUX-100 are packaged individually Installation technique Mounts on the CCP s right side ONLY and mechanically interlocks with the CCP switch handle with provided hardware. The CCP-AUX and CCP-AUX-100 CANNOT be mounted on the left front and left side rotary operated versions. Storage and operating temperature.9 33 NO 41 NC STRIP 34 NO 4 NC. -0 C to 75 C (-4 F to 167 F) Carton quantity and shipping weight 3.7.190 0.3 Catalog no. Application Qty. Weight lbs (kg) CCP-AUX-100 CCP-AUX For 30 and 60 A switches only 1 0.14 (0.063) CCP-AUX-100 For 100 A switches only 10

Compact Circuit Protector (CCP) Technical Data 10801 PLC fuse monitor Catalog numbers CCP-PLC-IND (30/60 A switches) CCP-PLC-100 (100 A switches) A resettable three-phase fuse monitor that integrates with the I/O card in a Programmable Logic Controller (PLC). A single unit can be mounted on any 1-, - or 3-pole 30 and 60 amp CUBEFuse CCP switch and the left front/ left side rotary operated switches. A single unit monitors up to three phases. When used on 1- and -pole switches unused conductor(s) are removed after installation. The CCP-PLC-IND CANNOT be mounted on the right front/right side rotary operated versions or if a multi-wire lug kit is installed. Ratings Signal output to PLC* +4 Vdc, 10 ma max Output signals Digital 0 Vdc (low), 4 Vdc max (high) 0 Vdc Low fuse is good 4 Vdc High fuse has opened * When the fuse opens, the output signal is sent high and will remain high until the unit is reset. Emissions and immunity testing IEC 60947-1: Voltage Switchgear and Control Gear IEC 61000-6-: Electromagnetic Compatibility (EMC) IEC 61000-4-: Electrostatic Discharge Immunity - Test at level 3 (6 kv-contact Discharge) and level (4 kv-air Discharge) IEC 61000-4-3: Electromagnetic Compatibility - Radiated, Radiofrequency, Electromagnetic Field Immunity test at level x (0 V/m) IEC 61000-4-4: Electromagnetic Compatibility - Testing and Measurement Techniques at level 3 (± kv - Power Port and ±1 kv - I/O Ports) IEC 61000-4-5: Electromagnetic Compatibility - Surge Immunity test at level 4 (±4 kv) IEC 61000-4-6: Immunity to Conducted Disturbances at level 3 (10 V) Agency information UL 98 Recognized, Guide WHTY, File E155130 curus to Canadian Standard. No. 4-04 Local indication Two distinct LEDs indicate unit power (green) and open fuse (red). Open fuse LED is resettable upon fuse replacement and the actuating the reset switch Wiring For power, signal and ground connections use shielded twisted pair -4 AWG (0.34-0.5 mm ) 300 V rated wire Packaging Catalog no.* Application Qty. Weight lbs (kg) CCP-PLC-IND CCP-PLC-100 30 and 60 A switches only 100 A switches only 1 0.17 (0.077) * Includes 0.110 (.8 mm) quick connects for power, signal and ground connections. Installation technique Mounts on the left side ONLY of the CCP and mechanically interlocks with the CCP switch handle with hardware provided. The CCP-PLC-IND and CCP-PLC-100 CANNOT be mounted on the right front/right side rotary operated versions or if a multi-wire lug kit is installed. IP0 rating yes Storage and operating temperature -0 C to 75 C (-4 F to 167 F) PLC programming The CCP-PLC-IND or CCP-PLC-100 signal line is designed to provide a digital input to a PLC I/O card. In this case, a Programmable Logic Control program must be written to properly interpret the input signal to the PLC. The PLC program should check for consecutive high signals before taking action on a critical process. Catalog no. Switch CCP-PLC-IND CCP-PLC-100 30/60 A only 100 A only Wired remote fuse indication for PLC applications Max per CCP** 1 per CCP (1, - or 3-pole) Signal output to PLC 4 Vdc/ 10 ma Min. circuit volts 100 Vac ** The CCP-PLC-IND and CCP-PLC-100 CANNOT be mounted on the right front/ right side rotary operated versions or if a multi-wire lug kit is installed. De-energize all circuits and follow all prescribed safety procedures before installing or removing the CCP-PLC-IND or CCP-PLC-100. 11

Technical Data 10801 Compact Circuit Protector (CCP) Installed on a CCP-3-xx PLC wiring schematic PLC power supply CCP-PLC-IND CCP-PLC-IND mounted on a 3-pole switch and using the fork terminals. When mounted on a - or 1-pole switch, remove unused leads. Note: the CCP-PLC-IND CANNOT be mounted on the right front/ right side rotary operated versions or if the multi-wire lug kit is installed. Dimensions in +4 Vdc 0 Vdc/Gnd +4 Vdc 0 Vdc/Gnd PLC input card +4 Vdc 0 Vdc/Gnd Signal 10 ma max. The CCP-PLC-IND needs to be powered by the same +4 Vdc and ground (0 Vdc/Gnd return) terminals that feed the PLC input card. If it is not, it may improperly signal. If feeding multiple CCP-PLC-INDs from different power supplies, there must be multiple input cards being powered by those same power supplies as well. ON RESET 1.8 STATUS +4vDC +4vDC GND SIG Pin interlocks with CCP switch handle.6 5L 3 3L 1L 1 6T 3 4T T 1 1.9 3.7 0.3 CCP-PLC-IND ON.0 RESET STATUS +4vDC +4vDC GND SIG Pin interlocks with CCP switch handle 1L 1 3L.9. 5L 3 6T T 3 4T 1 3.7 0.3 CCP-PLC-100 1

Compact Circuit Protector (CCP) Technical Data 10801 30 and 60 A CCP Switches For a complete assembly, select from the following required and optional components and accessories. Required Catalog no. Switches Amps Poles Switch (used alone or with flange cable or flange rod handles) CCP-1-30CF 1 CCP--30CF 30 CCP-3-30CF 3 CCP-1-60CF 1 CCP--60CF 60 CCP-3-60CF 3 Lug kits Optional CCP-MW1-3 3-port multi-wire, 75 C Cu/Al, 6-14, includes terminal shields, pack of 3 Terminal shrouds CCP-TS1-3 Pack of 3 Auxiliary contacts mounts on right side Accessories CCP-AUX NO + NC, 5 A / 40 V PLC fuse monitor mounts on left side CCP-PLC-IND Signal output 4 Vdc / 10 ma 13

Technical Data 10801 Compact Circuit Protector (CCP) 30 and 60 A CCP Clockwise rotary switches For a complete assembly, select from the following required and optional components and accessories. Catalog no. Switches Amps Poles Right front rotary CCPR--30CF 30 CCPR-3-30CF 3 CCPR--60CF CCPR-3-60CF 60 3 Required Left front rotary CCPRL--30CF 30 CCPRL-3-30CF 3 CCPRL--60CF 60 CCPRL-3-60CF 3 Right side rotary CCPS--30CF 30 CCPS-3-30CF 3 CCPS--60CF 60 CCPS-3-60CF 3 Rotary handles NEMA rating CCP-H4X-B1 Selector handle black/grey CCP-H4X-R1 CCP-H4X-B Selector handle red/yellow Pistol handle black/grey 4X CCP-H4X-R Pistol handle red/yellow Shafts (8 mm) CCP-SH1-90 CCP-SH1-490 Lug kits Length 90 mm 490 mm Optional CCP-MW1-3 3-port multi-wire, 75 C Cu/Al, 6-14, includes terminal shields, pack of 3 14

Compact Circuit Protector (CCP) Technical Data 10801 Terminal shrouds CCP-TS1-3 Pack of 3 Auxiliary contacts use with CCPRL-(poles)-30/60CF switches Accessories CCP-AUX NO + NC, 5 A / 40 V PLC fuse monitor use with CCPR-(poles)-30/60CF and CCPS-(poles)-30/60CF switches CCP-PLC-IND Signal output 4 Vdc / 10 ma 15

Technical Data 10801 Compact Circuit Protector (CCP) 30 and 60 A CCP Counterclockwise switches For a complete assembly, select from the following required and optional components and accessories. Catalog no. Switches Amps Poles Left side rotary CCPSL--30CF 30 CCPSL-3-30CF 3 Required CCPSL--60CF 60 CCPSL--60CF 3 Rotary handles NEMA rating CCP-H4X-B1L Selector handle black/grey CCP-H4X-R1L CCP-H4X-BL Selector handle red/yellow Pistol handle black/grey 4X CCP-H4X-RL Pistol handle red/yellow Shafts (8 mm) CCP-SH1-90 CCP-SH1-490 Lug kits Length 90 mm 490 mm Optional CCP-MW1-3 3-port multi-wire, 75 C Cu/Al, 14-6, includes terminal shields, pack of 3 Terminal shrouds CCP-TS1-3 Pack of 3 Accessories Auxiliary contacts mounts on right side CCP-AUX NO + NC, 5 A / 40 V 16

Compact Circuit Protector (CCP) Technical Data 10801 100 A CCP Switches For a complete assembly, select from the following required and optional components and accessories. Catalog no. Switches Amps Poles Switch (used alone or with flange cable or flange rod handles) Required CCP-1-100CF 1 CCP--100CF 100 CCP-3-100CF 3 Lug kits Optional CCP-MW1-6 6-port multi-wire, 75 C Cu/Al, 6-14, includes terminal shields, pack of 3 Terminal shrouds CCP-TS1-6 Pack of 3 Auxiliary contacts mounts on right side, cannot be used with flange rod handle Accessories CCP-AUX-100 NO + NC, 5 A / 40 V PLC fuse monitor mounts on left side, cannot be used with flange rod handle CCP-PLC-100 Signal output 4 Vdc / 10 ma 17

Technical Data 10801 Compact Circuit Protector (CCP) 100 A CCP Clockwise rotary switches For a complete assembly, select from the following required and optional components and accessories. Catalog no. Switches Amps Poles Right front rotary CCPR--100CF 100 CCPR-3-100CF 3 Left front rotary CCPRL--100CF 100 CCPRL-3-100CF 3 Right side rotary Required CCPS--100CF 100 CCPS-3-100CF 3 Rotary handles NEMA rating CCP-H4X-B1 Selector handle black/grey CCP-H4X-R1 CCP-H4X-B Selector handle red/yellow Pistol handle black/grey 4X CCP-H4X-R Pistol handle red/yellow Shafts (8 mm) CCP-SH1-90 CCP-SH1-490 Lug kits Length 90 mm 490 mm Optional CCP-MW1-6 6-port multi-wire, 75 C Cu/Al, 6-14, includes terminal shields, pack of 3 18

Compact Circuit Protector (CCP) Technical Data 10801 Terminal shrouds CCP-TS1-6 Pack of 3 Accessories Auxiliary contacts use with CCPRL-(poles)-100CF switches CCP-AUX-100 NO + NC, 5 A / 40 V PLC fuse monitor use with CCPR-(poles)-100CF and CCPS-(poles)-100CF switches CCP-PLC-100 Signal output 4 Vdc / 10 ma 19

Technical Data 10801 Compact Circuit Protector (CCP) 100 A CCP Counterclockwise switches For a complete assembly, select from the following required and optional components and accessories. Catalog no. Switches Amps Poles Left side rotary CCPSL--100CF 100 CCPSL-3-100CF 3 Required Rotary handles NEMA rating CCP-H4X-B1L Selector handle black/grey CCP-H4X-R1L Selector handle red/yellow 4X CCP-H4X-BL Pistol handle black/grey CCP-H4X-RL Pistol handle red/yellow Shafts (8 mm) CCP-SH1-90 CCP-SH1-490 Lug kits Length 90 mm 490 mm Optional CCP-MW1-6 6-port multi-wire, 75 C Cu/Al, 6-14, includes terminal shields, pack of 3 Terminal shrouds CCP-TS1-6 Pack of 3 Accessories Auxiliary contacts mounts on right side CCP-AUX-100 NO + NC, 5 A / 40 V 0

Compact Circuit Protector (CCP) Technical Data 10801 Motor sizing table: Low-Peak TCF_ and TCF_RN time-delay Class CF fuses Voltage 115 Vac, 1-phase 30 Vac,1-phase 00 Vac, 3-phase 08 Vac, 3-phase Motor size (Hp) Motor FLA (amps) Optimal protection (amps) Code max (amps) Heavy start* (amps) 0.167 4.4 10 10 10 0.5 5.8 10 15 15 0.333 7. 15 15 15 0.5 9.8 15 0 0 0.75 13.8 5 5 30 1 16 5 30 35 1.5 0 30 35 45 4 40 45 50 3 34 50 60 N/A 5** 56 90 100 N/A 0.167. 6 6 6 0.5.9 6 6 6 0.333 3.6 6 10 10 0.5 4.9 10 10 10 0.75 6.9 15 15 15 1 8 15 15 17.5 1.5 10 15 0 0 1 0 5 5 3 17 5 30 35 5 8 45 50 60 7.5 40 60 N/A N/A 10** 50 80 90 N/A 0.5.5 6 6 6 0.75 3.7 6 10 10 1 4.8 10 10 10 1.5 6.9 15 15 15 7.8 15 15 17.5 3 11 17.5 0 0 5 17.5 30 35 35 7.5 5.3 40 45 50 0** 6.1 100 N/A N/A 0.5.4 6 6 6 0.75 3.5 6 10 10 1 4.6 10 10 10 1.5 6.6 10 15 15 7.5 15 15 15 3 10.6 17.5 0 0 5 16.7 5 30 35 7.5 4. 40 45 50 0** 59.4 90 N/A N/A Voltage 30 Vac, 3-phase 460 Vac, 3-phase 575 Vac, 3-phase Motor size (Hp) Motor FLA (amps) Optimal protection (amps) Code max (amps) Heavy start* (amps) 0.5. 6 6 6 0.75 3. 6 6 6 1 4. 10 10 10 1.5 6 10 15 15 6.8 15 15 15 3 9.6 15 0 0 5 15. 5 30 30 7.5 35 40 45 0** 54 90 100 N/A 0.5 1.1 3 3 3 0.75 1.6 3 3 3 1.1 6 6 6 1.5 3 6 6 6 3.4 6 6 6 3 4.8 10 10 10 5 7.6 15 15 15 7.5 11 17.5 0 0 10 14 5 5 30 15 1 35 40 45 0 7 40 50 60 50** 65 100 N/A N/A 0.5 0.9 3 3 3 0.75 1.3 3 3 3 1 1.7 3 3 3 1.5.4 6 6 6.7 6 6 6 3 3.9 6 10 10 5 6.1 10 15 15 7.5 9 15 0 0 10 11 17.5 0 0 40** 41 70 80 80 Note: Use Code max column for low to moderate reverse/jog/plug applications. * Heavy Start permitted only if Code Max does not allow motor start-up. ** If equipment terminations are rated for 60 C conductors only, the 60 C conductor ampacities must be utilized and therefore larger conductor sizes or conduit sizes may be required. 1

Technical Data 10801 Compact Circuit Protector (CCP) The only controlled copy of this data sheet is the electronic read-only version located on the Eaton network drive. All other copies of this document are by definition uncontrolled. This bulletin is intended to clearly present comprehensive product data and provide technical information that will help the end user with design applications. Eaton reserves the right, without notice, to change design or construction of any products and to discontinue or limit distribution of any products. Eaton also reserves the right to change or update, without notice, any technical information contained in this bulletin. Once a product has been selected, it should be tested by the user in all possible applications. Eaton 1000 Eaton Boulevard Cleveland, OH 441 United States Eaton.com Bussmann Division 114 Old State Road Ellisville, MO 6301 United States 018 Eaton All Rights Reserved Printed in USA Publication No. 10801- BU-MC18054 September 018 Eaton, Bussmann and CUBEFuse are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use the Eaton trademarks without prior written consent of Eaton. CSA is a registered trademark of the Canadian Standards Group. NEC is a registered trademark of the National Fire Protection Association, Inc. UL is a registered trademark of the Underwriters Laboratories, Inc. For Eaton s Bussmann series product information, call 1-855-87-766 or visit: Follow us on social media to get the latest product and support information.