Similar documents
XP-AIR Multi-Port Power Pack Operation and Maintenance Manual

XP-115 Multi-Port Power Pack Operation and Maintenance Manual

KLW4000D Multi-Port Power Pack

TWO-STAGE HYDRAULIC PUMP. RWP55-IBT-Air

Operating instructions Form no safety definitions

Hydraulic Gear Puller Instruction Manual

OPERATOR S MANUAL Model 60010

Hand Pump Instruction Manual

2 Speed Hydraulic Hand Pump

Hydraulic Spreader. Operating Instructions & Parts Manual

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

Hydraulic Spreader Instruction Manual

Stud Tensioner. Leading provider of bolt loading & removal solutions

Gas Engine Pumps Instruction Manual

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Collision Repair Set. Form No No. 1517A 4-Ton Set. No. 1519A 10-Ton Set. Parts List & Operating Instructions for: 1519A. Part No. Item No.

Instruction Manual. Maximum Operating Pressure 510 bar

WCI-20 Power-Pak Coldwork Hydraulic Power Supply Rev B

Hand Pump Instruction Manual

Air / Hydraulic Pump

Operating Instructions & Parts Manual. Model HW93300 shown

Hand Pump Instruction Manual

MANUAL SERVICE MANUAL FOR HYDRASTAR HYDRAULIC TRAILER BRAKE ACTUATORS

FTMP-8 AND FTMP-12 Midget Puller Units

Manifold w/ Needle Valve Instruction Manual

Air Assist Bottle Jack Max. Capacity: 12 Tons (4313C) & 20 Tons (4321C) Operating Range: psi

Operating Instructions & Parts Manual

OWNER S MANUAL PRODUCT CODE: 2006T

Operating Manual & Safety Instructions ProTorc Hydraulic Torque Wrench Model # PTLC - Please read in full before operating ProTorc Torque Wrench -

Maintenance Kits Instruction Manual

Rams. Operating Instructions & Parts Manual. Model Number B65141 B65553 B65555 B65441 B65446 B65449 B65746

Operating Instructions & Parts Manual. Supa-Lite Lever Grease Gun. Model 48UJ77

Porta-Punch Manual

SERIES OPERATION AND MAINTENANCE MANUAL

Air / Hydraulic Floor Service Jack

High Tonnage Single Acting Cylinders Instruction Manual

Service Jack. Form No Parts List & Operating Instructions 1510B. Max. Capacity: 5 and 10 Tons. 1 of 3. Sheet No. Issue Date: Rev.

Operating & Maintenance

Single Acting Aluminum Cylinders Instruction Manual

Air-Assist Service Jack Max. Capacity: 10 Tons

Instruction Manual. Single Acting Hydraulic Aluminium Pull Cylinders RAP Series. Maximum Operating Pressure 700 bar

High Tonnage Double Acting Cylinders Instruction Manual

High Tonnage Single Acting Cylinders Instruction Manual

Single Acting Flat Body Cylinders Instruction Manual

Instruction Manual. Maximum Operating Pressure 700 bar

Air Hydraulic Pumps Instruction Manual

Telescopic Transmission Jacks

Air / Hydraulic Floor Service Jack

Operating Instructions & Parts Manual

STRAIGHT DIE GRINDER MODEL EGA530 OWNERS MANUAL

PNEUMATIC SLIDING VALVE

Instruction Manual. Double Acting Hydraulic, Hollow Piston Cylinders RHD Series. Maximum Operating Pressure 700 bar

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Maximum Operating Pressure 10,000 PSI

Gauge Adapter Instruction Manual

Instruction Manual. Single Acting, High Tonnage, Low Height Cylinders RSH Series. Maximum Operating Pressure 700 bar

OPERATING INSTRUCTIONS. HTL-DSX Dedicated Square Drive Wrench

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance Troubleshooting

AIR/HYDRAULIC INJECTION GUN MODEL INSTRUCTIONS

Low Lift Transmission Jack

Instruction Manual. Single Acting, Aluminium, Locking Collar Hydraulic Cylinders ARSLC Series. Maximum Operating Pressure 700 bar

Air Actuated Hydraulic Bottle Jacks

Mini Jacks Instruction Manual

MODEL G300 BRAKE BLEEDER

MODEL G300 Brake Bleeder

1/4 ANGLE DIE GRINDER

D-Series Blowers and Exhausters

Air Actuated Hydraulic Treadle Pump

Instruction Manual. Single Acting, Pancake, Locking Collar Hydraulic Cylinders RPLC Series. Maximum Operating Pressure 700 bar


Air / Hydraulic Pump Instructions. CAUTION: Read and Understand These Operating, Servicing, and Safety Instructions, Before Using This Machine.

Operating Instructions 20 Ton Air/Hydraulic Service Jack

PE 20 SERIES ELECTRIC POWER PUMPS

OPERATIONS MANUAL LEVER CHAIN HOIST

Power Units. Leading provider of bolt loading & removal solutions

Low Profile Lock Nut Cylinders Instruction Manual

Portable Two-Stage Under Axle Jack Max. Capacity: First Stage: 27.5 Tons Second Stage: 11 Tons. Safety Precautions

Hydraulic PTO Flow Device

User s Manual D-Series Blowers and Exhausters

Air Hydraulic Pumps Instruction Manual

Porto-Power Kit Operating Instructions & Parts Manual

ATD-7384W 12-Ton Bottle Jack Owner s Manual

Operating Instructions & Parts Manual

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

IBT Series Square Drive Torque Wrenches

Under Axle Jack Max. Capacity: 25 Tons

Forklift Jack. Scissors Max. Capacity: 4 ton Scissors Low Height: 2-5/32 in. (55 mm) Scissors High Height: 17-29/32 in. (455 mm)

Hydraulic Long Jacks

Maintenance Manual. Automated. Fuel Maintenance System FTI-5A. FUEL TECHNOLOGIES INTERNATIONAL LLC

Maintenance Manual WITH ONE SUBMERSIBLE PUMP. Automated Fuel Maintenance System FTI-5A FUEL TECHNOLOGIES INTERNATIONAL LLC

Single Acting Pull Cylinders Instruction Manual

Instruction Manual. 08 Series Auto 2 Speed Electric Power Units Model PEM8414 & PEM8424. Maximum Operating Pressure 700 bar

BOGERT HMMWV LIFTING JACK KIT PART NR: 30M-HVBMI NSN:

Operating Instructions and Parts Manual Long Chassis Service Jacks

ATD-7391A 10-Ton Long Chassis Service Jack Owner s Manual

Maintenance Manual. Automated Fuel Maintenance System FTI-5A SINGLE TANK FUEL TECHNOLOGIES INTERNATIONAL

Read this entire manual before operation begins.

6602LP CAPACITY: 2 TON LOW RIDER SERVICE JACK

HexPro Series Low Profile Wrenches

Read this entire manual before operation begins.

Transcription:

ZipPULLER Subsea Flange Puller Operations & Maintenance Manual KEEP FOR YOUR RECORDS 1

Contents Introduction Safety Tips Power Requirements Assembly Operation Maintenance Trouble Shooting Guide Limited Warranty INTRODUCTION With the FASTORQ Auto-Zip Sub-Sea Flange Puller you can safely and efficiently pull flanges together in an underwater environment. Versatility: can be used on a wide range of flange sizes Flexibility: Fits on ANSI and API flanges Precision: Pulling Force is controlled by adjusting pump pressure Speed: Extends and retracts without manual intervention SAFETY TIPS Do not allow the hydraulic hoses to kink, twist, curl or bend so that the oil flow within becomes blocked or reduced. Never attempt to grasp a pressurized hose that is leaking. Never exceed 10,000 psi of hydraulic pressure while operating the equipment. NOTE: (See Parts Layout & Description on Page 5) # 4 Double-Zip Pulling Device and # 6 Double-Zip Reaction Device are seated at the factory. Opening these components will void the warranty. 2

POWER REQUIREMENTS The Auto-Zip Sub-Sea Flange Puller is hydraulically driven. All models require a hydraulic pump that delivers 10,000 psi of pressure. Recommended FASTORQ Hydraulic Pumps to be used with the Auto- Zip Sub-Sea Flange Puller: 205A - Air Driven (as seen above) 215E - Electric All FASTORQ hydraulic pumps include the necessary fittings and hoses. If a FASTORQ hydraulic pump is not being used to power the Auto-Zip Sub-Sea Flange Puller, the following requirements must be met: Valve Type / 4-way Hose Rated at 10,000 psi Usable Minimum Capacity / 460 in 3 3

Parts Layout and Description 1. Double-Zip Control Lever (open position) 2. Double-Zip Control Lever (open position) 3. 1-7/8" Double-Zip Reaction Nut 4. Double-Zip Pulling Device 5. 60 Ton Auto-Zip Sub-Sea Flange Puller cylinder 6. Double-Zip Reaction Device 7. 1-7/8" Threaded Puller Bar ASSEMBLY 1. Put Double-Zip Control Levers (1 ) and (2) in the "OPEN" position. 2. Slide the threaded puller bar (7) through the center of the flange puller 3. Put the Double-Zip Control Levers (1 ) and (2) in the "CLOSED" position. 4

OPERATION 1. Slide the free end of the Threaded Puller Bar (7) through a bolt hole in one flange half and extend the Threaded Puller Bar (7) through a bolt hole in the opposite flange half. Push the Double-Zip Reaction Nut (3) on the end of the Threaded Puller Bar (7). 2. Position the second Flange Puller on the flange 180 (opposite) of the first. Repeat Step 1. 3. Connect hydraulic hoses to the quick disconnects on each Flange Puller and the opposite hose ends to the TB3 manifold at the pump. 4. Press the Advance Button on the remote control to extend the Flange Puller cylinders and draw the flange halves closer together. 5. Push the Retract Button to retract the Flange Puller cylinders to reposition the Double-Zip Pulling Device (4) for another stroke. TB3 Manifold with two hose sets 6. Repeat steps 4 and 5 until the two flange halves are close enough to insert the stud bolts and secure them with nuts. 5

MAINTENANCE The Auto-Zip Sub-Sea Flange Puller is designed to be a low maintenance tool. The following should be done a regular basis to increase the longevity of the tool: 1. Always wash down the tool with fresh water after use 2. Lubricate all moving parts with FASTORQ 70+ lubricant 3. Replace the dust covers on the quick disconnects and thread protectors on the cylinder after each use Troubleshooting Table Problem Possible Causes Possible Solutions Cylinder does not hold pressure Cylinder does not advance or advances partially Cylinder advances slowly Cylinder does not retract, retracts slowly or retracts partially 1. Cylinder seal leaking 2. Leaking connection 3. Pump malfunction 1. Pump release valve open 2. Not enough oil in pump 3. Air in system 4. Couplers not tightened 5. Pump reservoir too small 6. Strainer on pump is clogged 1. Leaking connection 2. Restricted hydraulic hose or fitting 3. Loose coupler 4. Pump flow rate too slow 1.Pump release valve closed 2. Coupler not fully closed 3. Blocked hydraulic hose 4. Pump reservoir overfilled 1. Change cylinder 2. Tighten connections 3. Change pump 1. Close valve 2. Add oil 3. Bleed air 4. Fully tighten couplers 5. Change pump (use one w/ larger reservoir) 6. Clean Strainer 1. Tighten connections 2. Change hoses or fittings 3. Tighten couplers 4. Change pump (use one w/ faster flow rate) 1. Open valve 2. Close coupler 3. Replace hoses 4. Remove excess oil 6

LIMITED WARRANTY FASTORQ Bolting Systems warrants its products against defects in workmanship and materials for 180 days from date of delivery to customer. Warranty does not cover ordinary wear and tear, abuse, misuse, overloading or altered products. 7