GAS MODEL SERIES: HFGE/O 16.5kW 60Hz FUEL: Propane (Natural Gas) PRIME MOVER: Ford TSG 416

Similar documents
GMN - 22P 29/07/2016 GMN - 022P (ACP KPR) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW22P. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

GMS - 560V 06/05/2016 GMS - 560V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSL30D. Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 0.8 Phase and connection 3

60 Hz FEATURES. Exclusively from your Caterpillar dealer

GMS-015Y. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

GSW500DO. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Power kva 9,3 10 Power kw 9,3 10 Rated Speed r.p.m Standard Voltage V 240 Rated at power factor Cos Phi 1

,QGXVWULDO#*HQVHW. 3RZHU#5DWLQJ 4833#USP283#+] 4;33#USP293#+] 3ULPH 27.5kVA, 22.0kW 32.5kVA, 25.9kW 6WDQGE\ 30.0kVA, 24.1kW 35.5kVA, 28.

HFW-350 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by FPT_IVECO

GSW80P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

HDW-200 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Soundproof Powered by DOOSAN

GSW150P. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Standby kw Prime kw

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Prime 60Hz 155 kw / 193 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

DIESEL GENSET. Prime 60Hz 36 kw / 45 kva

DIESEL GENSET. Prime Hz 16 kw / 20 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

GMS - 600V 06/05/2016 GMS - 600V (ACP) Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

Prime 60Hz 18 kw / 18 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings Prime Ratings kw/kva 240MONO / / 18

GSW-705V. Main Features Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3

DIESEL GENSET. Prime 60Hz 91 kw / 114 kva

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

TM20UCM MODEL. Standard Features. Generator Ratings. Conditions of sale. Prime Hz 18 kw / 18 kva. General features :

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva. Prime Ratings kw/kva 240MONO / 10 9 / 9

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

60 Hz FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENSET. Prime 60Hz 55 kw / 68 kva

Generating Rates WATER-COOLED THREE PHASE 50 HZ DIESEL. ADVANCED with quality certification ISO 9001

GSW35Y. Main Features. Frequency Hz 50 Voltage V 400 Power factor cos ϕ 0.8 Phase and connection 3. Power Rating

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

PRIME 400 ekw 500 kva 50 Hz 1500 rpm 415 Volts

Prime 60Hz 455 kw / 568 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Spark-Ignited Generator Set Model GGKC 60 Hz

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

Prime 60Hz 273 kw / 341 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

Prime Hz 400 kw / 500 kva. Voltage HZ Phase P.F Standby Amps Standby Ratings kw/kva

GCW22P (ALT. LSM) Main Features Frequency Hz 50 Voltage V 230 Power factor cos ϕ 1 Phase and connection 1

PRAMAC GBW 45. Main features. GBW Series. Item code: SB450TPAY kw. Standby power LTP. 34 kw. Rated prime power (PRP)

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

G100U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

RENTAL DIESEL GENERATOR SET

QT025A 2.4L 25 kw INDUSTRIAL SPARK-IGNITED GENERATOR SET EPA Certified Stationary Emergency

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Spark-Ignited Generator Set Model GGFD 60 Hz

GEP30 (3-Phase) 50 HZ. 27 kva / 21.6 kw 60 HZ. 30 kva / 24.0 kw FEATURES. Exclusively from your Caterpillar dealer

kva kw kva Dry Weigt Length Width kg K.U.N.Z. Handels-&Produktions GmbH

GEP50-3 (3-Phase) 50 HZ kva / 40.0 kw 60 HZ kva / 45.0 kw FEATURES. Exclusively from your Caterpillar dealer

G50U MODEL STANDARD FEATURES GENERATOR RATINGS CONDITIONS OF SALE. General features :

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

DIESEL GENERATOR SET MTU 18V2000 DS1400

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

PRIME 220 ekw 275 kva 50 Hz 1500 rpm 415 Volts

Spark-Ignited Generator Set Model GGKD 60 Hz

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

kva kw kva kw Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor Length mm

DIESEL GENERATOR SET MTU 12V4000 DS2250

Voltage. kva kw kva kw

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

DIESEL GENERATOR SET MTU 16V2000 DS KVA

DIESEL GENERATOR SET MTU 4R0113 DS80

DIESEL GENERATOR SET MTU 12V4000 DS1650

DIESEL GENERATOR SET MTU 16V2000 DS1000

DIESEL GENERATOR SET MTU 20V4000 DS4000

GEP110 (3-Phase) 50 HZ. 100 kva / 80 kw 60 HZ. 113 kva / 90.4 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SET MTU 16V2000 DS1100

Subsidiaries: PORTUGAL POLAND GERMANY UK SINGAPORE UAE PANAMA DOMINICAN REPUBLIC ARGENTINA ANGOLA SOUTH AFRICA

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

DIESEL GENERATOR SET MTU 12V1600 DS660

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

Spark-Ignited Generator Set Model GGLA 60 Hz

DIESEL GENERATOR SET MTU 16V4000 DS2500

YOUR POWER PARTNER. Enclosed product is tested according to EU noise legislation 2000/14/EC. Voltage kva kw kva kw 400/ ,

DIESEL GENSET. Voltage HZ Phase P.F Standby Amps Standby Ratings 1 kw/kva

DIESEL GENERATOR SETS

This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

CUMMINS 30KVA. Voltage kva kw kva kw Amp 400/230 30,00 24,00 27,00 21,60 38,00

Standby Rated Generators. Standby SG kva / 28 kw. Prime PG kva / 22 kw

Perkins 1006TG2A diesel engine Mecc Alte ECP34-2S/4 alternator Standard Generator Features

kva kw kva kw 9,6 14 Automatic syncronization and power sharing systems 50 C tropical type radiator Soundproof canopy Starter motor

This generator set has been designed to meet ISO 8528 regulation. Enclosed product is tested according to EU noise legislation 2000/14/EC

Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Open Skid Powered by SCANIA

DIESEL GENERATOR SET MTU 12V4000 DS1750

Model NA 2 L

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

P 602. This generator set has been designed to meet ISO 8528 regulation. This generator set is manufactured in facilities certified to ISO 9001.

DIESEL GENERATOR SET MTU 20V4000 DS3600

HFW-85 T5. Generating Rates SERVICE PRP STANDBY. INDUSTRIAL RANGE Standard soundproofing Powered by FPT_IVECO

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

STANDBY 250 ekw 313 kva 60 Hz 1800 rpm 208 Volts

DIESEL GENERATOR SET MTU 20V4000 DS3300

Transcription:

DATA AND PERFORMANCE SHEET GAS MODEL SERIES: HFGE/O 16.5kW (15kW) @ 60Hz FUEL: Propane (Natural Gas) PRIME MOVER: Ford TSG 416 Configuration Propane kw Natural Gas kw Open HFGO-16P1(P3) HFGO-15N1(N3) 16.5 15.0 Enclosed HFGE-16PI(P3) HFGE-15N1(N3) NOTE: P1/N1 = Single Phase P3/N3 = Three Phase Standard Specification (For stationary use only in the US) ENGINE Water-cooled, four-stroke Ford Gas engine model TSG 416. Isonchronous Electronic Governor under Woodward. In static conditions, provides stability service frequency of ±0.35%. standard. High voltage parts are impregnated with tropicalized epoxy resins by dipping and low vacuum, so that always an optimum insulation is guaranteed. In the high-power models, the stator windings undergo a further insulation. ELECTRICAL SYSTEM 12-volt system with battery charging alternator, ground connection, starting motor, battery-mounted on the genset baseframe, with heavy-duty interconnection cables and borne protection. (Battery supplied without electrolyte). A rock wool net has been installed in the doors in order to enable its cleaning and washing. This special net is also fire-resistant. All doors are lockable with safety key. For the best convenience at loading, unloading, and installation, the HIMOINSA gensets are provided of a strong lifting hook and forklift rails. COOLING SYSTEM Radiator and protected pusher fan with guards, designed for the engine cooling within ambient temperatures up to 122 F (50 C). However, the rated capacity of the genset is based on 77 F ambient temperature. Drain tap included. ALTERNATOR Self-regulated, auto-excited, brushless, windings treatment type for humid and saline climates. The windings have a 2/3 pitch in order to reduce the harmonic content of voltage; fixed inductor with skewed slots and a rotating inductor fitted with a damper cage. The self-regulation is obtained through an extremely reliable electronic regulator that provides a low speed and overload protection with an adjustable intervention threshold, available for 60Hz. Adjustable voltage stability with the possibility for a remote voltage regulation. 12 wires. Meets standards IEC 34-1, CEI 2-3, BS 4999-5000, VED 0530, NEMA MGI-22. Insulation and impregnation system Insulation class H Radio interference suppression Following the standard VDE 0875, degree G and N and with the basic safety requirements of the European regulation on electromagnetic compatibility; by applying the European standards EN 50081-1 and EN 50082-1, we comply with the above mentioned regulation. Automatic Voltage Regulation Accuracy ±1.5% with load from 0 to 100% speed from -2% to +5% and power factor range from 0.8 to 1 with balanced load. Overload The permissible overloads are of 300% for 20 seconds, of 50% for 2 minutes and of 10% for 1 hour. CONTROL SYSTEM Designed to gather the control electric instruments, alarm LED s and protections for both, engine and alternator. Built in steel sheet with a high quality painting process, to last in tropical climates and corrosive environments. Available in: key and automatic start versions. The automatic control panel allows the genset to deliver electric power a few seconds after mains failure. Once the utility supply is restored, the genset will shut down automatically. FUEL SYSTEM Gas. Woodward LC-50 propane vapor withdrawal. EXHAUST SYSTEM Exhaust silencer kit, vertical silencer, clamps and exhaust pipe. (Supplied loose), for open skid version. Residential silencer is standard for soundproofed versions. MOUNTING ARRANGEMENT Electro-welded structural quadrangular chassis in coated black steel profiles according to UNE 36.537 and DIN 17.119, 17.120 and 59.411 standards, fitted with anti-vibration supports isolating the perfect aligned engine-alternator with the baseframe. Fan protection guard, and front guard for radiator are included. In the soundproofed gensets, the canopies are manufactured in sheet metal providing low sound emission levels and protecting the genset from external damage. The rock wool isolating material used is noncombustible, non-corrosive to the metals and very durable. DOCUMENTATION Full set of engine, alternator, and genset maintenance and installation manuals, as well as electric circuit wiring diagrams. Testing certificate is available upon request. FACTORY TEST Before dispatch, all gensets are tested in our high technology load banks. The proper performance of the genset and its control and measurement instruments are also checked. WARRANTY All equipment is guaranteed for a period of 12 months from invoice date. Warranty terms and conditions are available upon request.

Weight: 3,935 lbs. Dimensions: 118 x 47 x 59 in Generating set performance 60Hz Specification details Max. Standby (F.S.P.) (2) Prime (P.R.P. (1) Rated output at 0.8 p.f. kw 16.5 (15.0) 13.7 (12.9) Rated speed r.p.m 1,800 Voltages available V 120/240; 480/277; 208/127 Ambient reference conditions: 1,000 mbar, 80.6 F, 30% relative humidity. * The indicated performance may change according to the alternator model. Prime mover performance 1,800 r.p.m. Specification details Max. Standby (F.S.P.) (2) Prime (P.R.P. (1) Rated output BHP 28 (26.5) 23.2 (22.7) BMEP Mean piston speed psi ft/min 126 891 Flywheel Housing SAE 5/6 1/2 --- --- Ambient reference conditions: 1,000 mbar, 77 F, 30% relative humidity. * Net performance at flywheel with tolerance of ±3% and available after 50 hours running. (1) Prime (P.R.P.) - ISO 8528: prime power is the maximum power available during a variable power sequence, which may be run for an unlimited number of hours per year, between stated maintenance intervals. The permissible average power output during a 24-hour period shall not exceed 80% of the prime power. 10% overload available for governing purposes only. (2) Max Stand-by power (ISO 3046 Fuel Stop power): power available for use at variable loads for limited annual time (500h), within the following limits of maximum operating time. 100% loads 25 h per year - 90%loads 200 h per year. No overload available. Applicable in case of failure of the main in areas of reliable electrical network.

Prime mover data Manufacturer Ford Model TSG 416 Spark ignition Ford DIS Aspiration type Naturally Aspirated Cylinders, number and arrangement I-4 Bore x stroke in (mm) 3.23 x 2.97 (82.1 x 75.5) Total displacement in³ (L) 97.3 (1.6) Cooling system Liquid Lube oil specification ILSAC GF-2 Fuel consumption @ F/L CFH 87 (220) Oil consumption TBD Speed governor Woodward LC-50 Isochronous Air filter Dry Synchronous generator* Poles N 4 Phases N 1+N (Standard) winding connections Low-Wye Frame mounting B - 2 Cooling by ventilating fan Windings treatment type for humid and saline climates Insulation class H Damper windings for parallel Enclosure (according to IEC 34-5) IP 21 Waveform distortion no more than 5% Overexcitation device (option) per Icc 3 In Exciter Brushless excited design with solid state Voltage regulator Static electronic design * Alternators used by HIMOINSA Gensets meet the requirements of following standards: ISO 8528; IEC 34-1; CEI 2-3; VDE 0530; BS 4999-5000; NF 51-100 * Ambient reference conditions: 1,000 mbar, 80.6 F, 30% relative humidity

Generating set installation data EXHAUST SYSTEM Max. exhaust temperature at full load F 1,100 Exhaust gas flow CFM 145 Heat rejected to exhaust & radiant Btu/min. 2,100 (1,460) Maximum allowable back pressure in H²O mm H²O 20 510 ENGINE ROOM AIR REQUIREMENT Fan air flow CFM 1,890 Air requirement for combustion at 100% load/rated speed CFM 47 COOLING SYSTEM ATB (without canopy) - nominal rating ºF ºC 120 49 Heat rejected to coolant Btu/min 728 (631) ELECTRIC STARTING SYSTEM Cranking motor rating kw TBD Minimum recommended battery capacity cca TBD Auxiliary voltage Vcc 12 LIQUID CAPACITY (REFILL) Lube oil total system including sump, filters, etc. Cooling system capacity total qts L qts L 4.4 4.2 TBD TBD GENERATING SET TRANSPORT DATA Basic data Soundproofed genset Shipping volume seaworthy packing ft³ 70 Dry weight (with standard accessories) Lb 1,720

Optional accessories Automatic start control panel 2 3 4 5 1 7 6 8 11 12 13 Stop cycl e Pr eheatin g Engine on LT close d 9 10 14 E00: Correct operation E01: High water temperature E02: Low oil pressure E03: Auxiliary input failure E04: Battery charge alternator failure E05: Start failure E06: Engine failure E07: Low fuel level E08: Fuel reserve E09: Overvoltage E10: Subvoltage E11: Asymmetry between phases E12: Overcurrent E13: Overfrequency E14: Subfrequency Char ge E15: High batery voltage E16: Low baterry voltage E17: Emergency stop Alarms 1. Switch-on button. 2. Display 1, phase voltage visual display. 3. Push-button V. to select voltage. 4. Display 2, Amperage visual display. 5. Push-button A, Phase amperage selector. 6. Display 3, Visual display for frequency, battery level fuel level or alarm code. 8. Display 4, visual display of working hours, speed meter water level temperature or oil level temperature. 9. Push-button D4, selects hour meter, speed indicator, water level temperature, oil level pressure. 10.1 Stopping cycle indicator. 10.2 Preheating indicator. 10.3 Engine on indicator. 10.4 LT Closed indicator. 11. Push-button mode START/MAN. 12. Push-button mode STOP/RESET. 13. Push-button mode AUT (automatic operation) 14. Alarm Codes, shown on display 3. E00: Correct operation E09: Over voltage E01: High water temperature E10: Under voltage E02: Low oil pressure E11: Asymmetry btwn. phases E03: Auxiliary input failure E12: Over current E04: Battery charge alt. failure E13: Over frequency E05: Start Failure E14: Underfrequency E06: Engine Failure E15: High battery voltage E07: Low fuel level E16: Low battery voltage E08: Fuel reserve E17: Emergency stop

Optional accessories UL-Listed circuit breakers 120-volt water jacket heater Digital timer - autostart only Battery chargers Extended warranty for certain standby applications Distributor: Himoinsa USA, Inc. 16210 West 110th Street Lenexa, KS 66219 Tel: 913-495-5557 Fax: 913-495-5575 www.himoinsausa.com info@himoinsausa.com