INTELLIGENT SOLAR MODULE ISM 1

Similar documents
Installation instructions. Cascade unit. For wall hung gas-fired condensing boiler GB162-50/65/80/ TD UK/IE (2014/09)

INSTALLATION INSTRUCTIONS CASCADE UNIT FOR WALL HUNG GAS-FIRED CONDENSING BOILER GB162-65/80/ TD UK/IE (2011/07)

INSTALLATION AND OPERATING INSTRUCTIONS SOLAR HEATING PROGRAMMER TDS SD UK/IE (2010/04)

Operating instructions

Solar Controller SUNGO S

SOLAR-LUX 6/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR FLAT ROOF INSTALLATION (30, 45 ) WALL INSTALLATION (45, 60, 90 )

SOLAR-LUX 6/12 INSTALLATION AND MAINTENANCE INSTRUCTIONS EVACUATED TUBE COLLECTOR ROOF MOUNTING INSTALLATION UK/IE (2011/05) GB/IE

- Wiring Brochure Mixing Expansion Module 440

RVD125/109 RVD145/109

2-PHASE STEPPING MOTOR DRIVER FE Z5 DISPENSE

Accessories for Wind Power Inverter WINDY BOY PROTECTION BOX 400 / 500 / 600

Solar Controller SUNGO S

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

DeltaSol AX * *

- Wiring Brochure Universal Reset Module 422

1000 Watt Power Inverter INSTRUCTION MANUAL HT87112-AUOXY

Solar Thermal. Grant Solar Pump Station Installation & Servicing Instructions

RVD120 RVD G2510. Installation. Place of installation. Electrical installation. Permissible cable lengths

Operating and Installation Instructions Swing Piston Compressors and Vacuum Pumps

SOLAR CHARGE CONTROLLER

Boiler Management Unit (BMU)

VIESMANN. Installation instructions VITOTROL 100. for contractors. Vitotrol 100 Type UTDB

FLUDEX - thermal switching equipment. Operating instructions BA en 04/2012. FLENDER couplings

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Swing Piston Compressors and Vacuum Pumps

JBE LED2000 INDUSTRIAL SOLUTIONS FOR LED & INCANDESCENT MAINS LIGHTING FLICKER FREE TRAILING EDGE DIMMER

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

SINAMICS DCM. DC Converter. Application SINAMICS DCM as field supply unit. Edition 04-6/2013. SINAMICS drives

Galaxy VM. Battery Breaker Box Installation 09/

Ordering designation: G(Type) - (Stroke) - (Eye bolt) - (Cable length) - (Options) Legend:

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

MANIFOLDS & WATER TEMPERATURE CONTROL

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

SINAMICS G130. Motor reactors. Operating Instructions 05/2010 SINAMICS

VIESMANN. Installation instructions VITOSOL 200. for heating engineers. Vitosol 200 Type SD2 Direct flow vacuum tube collector

High Frequency SineWave Guardian TM

Pan and Tilt Head CDD2416-T

Wilo-Control SC-Fire Jockey

POND PUMP Model Nos:SPP3 & SPP6 0200

SubDrive75/100/150/300 MonoDrive, MonoDriveXT

Sentry Battery Charger. Installation and Operations Manual Section 75

TECHNICAL INFORMATION

ELECTRICAL APPLIANCE SERVICEPERSON (QUALIFIED) EXAMINATION

Control Solutions Biofloor

CHAPTER 2: ELECTRICAL SAFETY

Compact System NRGS 11-2 NRGS Original Installation Instructions English

Compressor Refrigerator Instruction Manual

G2515. Installation. Place of installation. Electrical installation. Permissible cable lengths. Securing the controller to the base

VIESMANN. Installation instructions VITOSOL 200-T. for contractors. Vitosol 200-T Type SP2 Vacuum tube collector based on the heat pipe principle

ANS 21-PV. Simple solar control unit Photovoltaik version. Operation Installation instructions. Version 11 EN. Manual version 2

Actuators for air and gas dampers

Cat. No. I526-E1-1 USER S MANUAL 3G3IV-PLKEB2 /4. Braking Resistor Units 3G3IV-PCDBR2 B/4 B. Braking Units

HEAVY DUTY BATTERY BOOSTERS / CHARGER MODEL No. BC420N

ELECTRICIAN S THEORY EXAMINATION 20 June 2015 QUESTION AND ANSWER BOOKLET

The Ultracom Range High Efficiency Condensing Boilers A guide for homeowners

BATTERY CHARGER-STARTER

Electrical linear actuator with safety function MC100FSR/24

SOLAR-LIFESTYLE INSTALLATION AND MAINTENANCE INSTRUCTIONS FLAT-PLATE COLLECTOR FLAT ROOF AND WALL-MOUNTED INSTALLATION (2011/05) UK

Micro Diaphragm Gas Sampling Pumps

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

CAUTION. Disconnect Power

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

Installation and Operating Instructions. Solar System Controller ISC3020

BATTERY BOOSTERS / CHARGERS BC120N BC130N BC210N BC320E BC410E BC520N

Type MZ15. Operating Instructions. Bedienungsanleitung Manuel d utilisation

EN Operating manual. Motorised zone valve. Three-way, 22 mm & 28 mm 3PV2, 3PV8 & VRMH3

Cable Temperature QAP... Sensor. Use

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

ZonePlus Z322 zone valve Installation and commissioning instructions

FLENDER ARPEX Plate packs with close-fitting bolt connection. ARW-4 Sizes to Assembly instructions An 4239 en 12/2015.

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

VIESMANN. Installation instructions VITOFLAME 300. for contractors

Installation Instructions

GRUNDFOS INSTRUCTIONS. Grundfos ALPHA Installation and operating instructions

MMA 160S ARC/MMA WELDER OPERATION INSTRUCTIONS

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

Guardian Battery Charger Series. Installation and Operations Manual Section 75

THERMO TECHNOLOGIES USDT 2005 Analog Differential Controller

Opening hours Monday - Friday, 8.00am pm Weekends and Bank Holidays, 8.30am pm We are closed on Christmas Day and New Year s Day.

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

Installation Instructions

Installation Instructions Electric Heaters 5 20 kw

Installation Instructions

Installation Instructions

Manual Comfort Air Curtain

Product Guide 2012/13. Oil-fired and solar thermal. heating and hot water solutions

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Electromotoric Actuators

TLR2 RESOL TLR2 * * Mounting Connection Handling Fault localization. Manual

DeltaSol AX. RESOL DeltaSol AX * * Mounting Connection Operation Application examples. manual

VIESMANN. Installation instructions VITOSOL 300-T. for contractors. Vitosol 300-T Type SP3A Vacuum tube collector based on the heat pipe principle

ELECTRICAL INSTALLER EXAMINATION 18 November 2017 QUESTION AND ANSWER BOOKLET

Thermal-cutoff, Fuse and Fuseholder Incorporated into a Simple Compact Device

S&C Vista Underground Distribution Switchgear

Operating Instructions CYR52

Sivoia QED R Installation Instructions Please Leave for Occupant

Electrical Safety Part I

Transcription:

INTELLIGENT SOLAR MODULE ISM 1 INSTALLATION & USER INSTRUCTIONS FOR USE WITH THE FOLLOWING APPLIANCES AND ACCESSORIES: CDI SYSTEM OILER FITTED WITH OPTIONAL INTEGRAL DIVERTER VALVE FR110 PROGRAMMALE ROOM THERMOSTAT FW100 WEATHER COMPENSATION CONTROLLER 6 720 612 399-00.1O

Contents Contents Information regarding this documentation................. 2 1 Symbols and safety precautions....... 3 1.1 Symbols...................... 3 1.2 Safety precautions............. 3 Information regarding this documentation Hand all documentation enclosed to the user. 2 Technical data for the accessory item... 4 2.1 Intended use.................. 4 2.2 Standard package.............. 4 2.3 Technical data................. 4 3 Installation........................ 6 3.1 Installation.................... 6 3.1.1 Wall mounting................. 6 3.1.2 Mounting on the mounting rail.... 7 3.1.3 Removal from the mounting rail... 7 3.2 Electrical connections........... 7 3.2.1 Connection - low voltage section with US connection............7 3.2.2 230 V AC connection............ 8 3.3 Installation of supplementary accessories....................9 3.4 Connection diagram............ 9 4 Commissioning.................... 11 5 Fault mode....................... 11 2

Symbols and safety precautions 1 Symbols and safety precautions 1.1 Symbols Safety instructions in this document are identified by a warning triangle and are printed on a grey background. Signal words indicate the seriousness of the hazard in terms of the consequences of not following the safety instructions. Caution indicates that minor damage to property could result. Warning indicates that minor personal injury or serious material losses could result. Danger indicates that serious personal injury could result. In particularly serious cases, lives could be at risk. Notes are identified by the symbol shown on the left. They are bordered by horizontal lines above and below the text. 1.2 Safety precautions These instructions must be observed to ensure correct operation. Install and commission the boiler and all accessories in accordance with the associated instructions. Allow only qualified installers to install accessories. Use these accessories exclusively in conjunction with the controllers and boilers listed. Observe connection diagram. This accessory may require a different voltage. Never connect the low voltage side to the 230 V mains or vice-versa. efore installing these accessories: Isolate voltage supply (230 V AC) to the heating appliance and all additional devices using the bus. In case of wall mounting: Never install this accessory in damp areas. Notes contain important information in cases where there is no risk of personal injury or material losses. 3

Technical data for the accessory item 2 Technical data for the accessory item 2.1 Intended use This module ISM 1 is designed to control the components of a solar heating system that form part of a general heating system equipped with controllers FW 100 or FR 110. 2.2 Standard package 2.3 Technical data Standard delivery Fig. 1, page 4 Dimensions Fig. 2, page 6 Low voltage - US - ISM - controller - pump 15 V DC 230 V AC 10...24 V DC 230 V AC max. power consumption 4 A 6 720 612 405-01.1R Control output 2-wire US max. output - per connection (R 1 - R 3 ) 120 W Fig. 1 1 2x 2 1 ISM 1 2 Screws for securing the top section 3 Jumper in place of connecting a temperature limiter T 1 4 Strain relief fittings 5 Cylinder temperature sensor (T2) 6 Collector temperature sensor (T1) 3x 5 3 4x 6 4 Measuring range, cylinder temperature sensor 0... 99 C Measuring range, collector temperature sensor 20... 140 C permiss. ambient temp. - ISM - System temperature sensor - Cylinder temperature sensor - Collector temperature sensor Protection level Tab. 1 0... 50 C 0... 100 C 0... 100 C 20... 140 C IP44 4

Technical data for the accessory item Measuring values, cylinder temperature sensor (T2) Tab. 2 Measuring values, collector temperature sensor (T1) Tab. 3 C Ω C Ω 20 14772 56 3723 26 11500 62 3032 32 9043 68 2488 38 7174 74 2053 44 5730 80 1704 50 4608 86 1421 C Ω C Ω 20 198400 60 4943 10 112400 70 3478 0 66050 75 2900 5 50000 80 2492 10 40030 90 1816 15 32000 95 1500 20 25030 100 1344 25 20000 110 1009 30 16090 120 767 35 12800 130 591 40 10610 140 461 50 7166 5

Installation 3 Installation 3.1 Installation DANGER: Risk of electric shock Prior to connecting the power supply, isolate the boiler and all other US subscribers from the power supply. 3.1.1 Wall mounting 1. 93 106 110 2. 3. 68,2 65,7 156 55 13 4. 4. 6 720 612 405-03.1R 6 720 612 405-06.1R 6 mm 6 mm 3,5...5 mm mm Fig. 2 Fig. 4 6 720 612 405-05.1R 6 720 612 405-07.1R 6 mm 6 mm 3,5...5 mm mm Fig. 3 Fig. 5 6

Installation 3.1.2 Mounting on the mounting rail Fig. 6 3.1.3 Removal from the mounting rail 6 720 612 405-08.1R 3.2 Electrical connections Observe current wiring regulations, and use at least cable type H05 VV-... (NYM-I...) for the power connection. Always route cables/leads through the preassembled grommets and apply the strain relief supplied to protect the system against the ingress of dripping water. 3.2.1 Connection - low voltage section with US connection Permissible cable length between the Heatronic 3 with US capability and the ISM...: CAUTION: reaking open the back panel to remove the appliance from the mounting rail reduces the protection level to IP20. Cable length Cross-section 80 m 0.40 mm 2 100 m 0.50 mm 2 150 m 0.75 mm 2 2. 200 m 1.00 mm 2 300 m 1.50 mm 2 Tab. 4 6 720 612 405-09.1R Fig. 7 3. 1. To avoid inductive interference, lay all bus cables seperately to lines of 230 V or 400 V (minimum spacing 100 mm). In case of external inductive interference, shield the cables. This ensures that the cables are shielded from external interference (e.g. heavy current cables, overhead wires, transformer stations, radio and television set, amateur radio stations, microwave ovens etc). 7

Installation When sensor leads are extended, apply the following lead cross-sections: Cable length Cross-section 20 m 0.75 mm 2... 1.50 mm 2 3.2.2 230 V AC connection Only use electric cable of similar quality. Never connect additional control circuits that regulate other system components to the outputs. Tab. 5 30 m 1.00 mm 2... 1.50 mm 2 30 m 1.50 mm 2 To safeguard the splashproof rating (IP): Route cables so that the cable sheath protrudes at least 20 mm into the cable grommet ( Fig. 8). Never exceed the maximum power consumption of the system components as specified ( chapter 2.3 on page 4). When connecting several electrical devices: Protect the electrical devices with a separate isolator that provides a minimum contact separation of 3 mm, if the maximum power consumption exceeds the specified value (e.g. fuse, isolator). 6 720 612 405-21.1R 20 mm Fig. 8 8

Installation HLC E C 1 2 ISM 1 230V AC 230V R1 R2 R3 T 1 2 3 4 5 6 7 8 9 10 11121314 L N PE SP PE 3.3 Installation of supplementary accessories to protect an unvented domestic hot water cylinder Install supplementary accessories in accordance with legal requirements and the installation instructions supplied. HLC SRV SWC SWC L N E 4 5 6 7 8 9 10 May be supplied by the unvented domestic hot water cylinder manufacturers, please refer to the installation instructions, otherwise are available at plumber's merchants. 3.4 Connection diagram L N E 230V AC L G R O G/Y SRV L N E SP Module ISM 1 enables the creation of a standard solar heating system (system 1, solar DHW heating) with thermal disinfection option for the solar cylinder Fig. 9 HLC ISM 1 PE R1...3 SP SRV SWC T 6 720 617 765-02.1O Electrical connection of Solar Wiring Centre High limt control Module for standard solar heating systems Circulation pump for thermal disinfection (Option E) Connection for pump or diverter valve Solar circuit pump Solar return two port valve Solar wiring centre Temperature limiter Pump PE only for thermal disinfection. Fig. 10 on page 10 shows the connections required for this at module ISM 1. 9

Installation ISM 1 230V AC 24V 230V R1 R2 R3 T NTC1 NTC2 NTC3 US 1 2 3 4 5 6 7 8 9 10 1112 1314 1 2 3 4 5 6 L NPE L NPE L N PE SP PE T 1 T 2 US System 1 WW SWC 1) T 2) TWM T 1 Option E ZS 230V AC PE RV HP S 1) SP HLC RE 1) SRV SF T 2 M WS S RV KW HK 6 720 617 765-01.1O Fig. 10 System 1 with option E HK Heating circuit HLC High limt control HP Heating circuit pump ISM 1 Module for standard solar heating systems KW Cold water connection NTC1...3 Temperature sensor connection Option E Thermal disinfection of solar cylinder (optional hydraulical connection) PE Circulation pump for thermal disinfection (Option E) R1...3 Connection for pump or diverter valve RE Flow rate adjuster with indicator RV Non-return valve S Gravity brake SF Cylinder temperature sensor (boiler) SP Solar circuit pump SRV Solar return two port valve SWC Solar wiring center System 1Solar cylinder for solar DHW heating T 1 Collector temperature sensor T 2 Cylinder temperature sensor, bottom (solar cylinder) T Temperature limiter TWM Thermostatic DHW mixer WW DHW connection WS S Solar DHW cylinder ZS System boiler with optional built-in diverter valve 1) Electrcal Connection ( Fig. 9) 2) Instal as close to the cylinder hot water outlet as possible 10

Commissioning 4 Commissioning CAUTION: A fault condition could arise if power is supplied to the US before all components are connected. Connect all US subscribers prior to supplying the US with power. 5 Fault mode The operating display indicates the operating state of accessories. Faults are indicated in the controller display or that of the respective remote control. Operating display ISM response Fault/Remedy constantly OFF Switch ON power. flashing Controlled emergency mode: The ISM tries to respond to the fault with an alternative control strategy. constantly ON Standard mode not a fault Tab. 6 Replace fuse ( Fig. 11). HLC on unvented domestic hot water cylinders is open circuit. Reset and investigate cause of operation. If water is also seen discharging from any of the cylinder safety valves, a suitably qualified installer should be contacted immediately. The system yield is largely maintained. Nevertheless, the fault should be remedied, not later than during the next service. Fig. 11 6 720 612 404-23.1R 11

067206177615 CONTACT INFORMATION WORCESTER, OSCH GROUP: TECHNICAL: 08705 266241 SERVICE: 08457 256206 SPARES: 01905 752571 LITERATURE: 01905 752556 TRAINING: 01905 752526 SALES: 01905 752640 WESITE: www.worcester-bosch.co.uk Dedicated to heating comfort Worcester, osch Group Cotswold Way, Warndon, Worcester WR4 9SW Tel. 01905 754624 Fax. 01905 754619 Worcester, osch Group is a brand name of osch Thermotechnology Ltd. www.worcester-bosch.co.uk