Low Voltage Lighting Power Supplies

TA Ta VA CTRL-XFRMR

Approx. Net Frame Product Input Voltage Output Voltage kva Height (in) Width (in) Depth (in) Weight (Lbs.) Size Number

HPS Fusion General Purpose Enclosed Transformer

Features, Benefits and Functions

Class I Division 2. 1 to 25 kva. Applications. Specifications. Standards. Options and Accessories. Features, Functions, Benefits.

Midwest Dry Type Transformers

Transformers 6. Gross Automation (877)

Totally Enclosed Non-Ventilated

Single-Phase Ventilated

B BASIC HEAT TREATMENT CONSOLE

M-SERIES MAGNITUDE LIGHTING MAGNETIC DIMMABLE CLASS 2 LED DRIVER QUICK SPECS ENCLOSURE DETAILS

JUNCTION / DECK BOX. - Made of white ABS and push in cover with O-ring seal IP 55 weather protection.

ENCAPSULATED TRANSFORMERS FOR HAZARDOUS LOCATIONS

Three-Phase Ventilated

ICT TRANSFORMERS. Industrial Control Transformers provide a low and safe control voltage for the operation of many electromagnetic devices

Distribution Dry Type Transformers 600 Volts Class Single and Three Phase Selection

Planning Low Voltage Layouts

Industrial Control Transformers

50 Hz Mini/Micro Computer Regulator (MCR) Series Installation and Operation Manual

112.5 kva Transformer Delta Primary - 240/120V Secondary - 60 Hz - 3 Phase - NEMA 3R

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

Type FEC Epoxy Encapsulated, Copper-Wound Industrial Control Transformers

Medium Voltage Standby non-paralleling Control GUIDE FORM SPECIFICATION

OUTPUT CONNECTIONS Bring the wires of the light fixture through the other open knockout and connect them to the power supply output wires.

SPECIFICATION SHEET. Transformers. Cable cord: Core: Timers & Photocell: Wire Rating: Certification: Warranty: OFF. Bottom mounting slot Front View

Dry-Type Transformers Mini-Power Centers

Medium Voltage Metal-Enclosed Switches

Wiring Diagram Number

New dimming drivers are compatible with most wall dimmers for % light control. For non-dimming

Jefferson Electric Class I Division 2 Transformers for hazardous locations

BF Series Flasher Thermal flasher circuitry

Three Phase Transformers

Control Circuit Transformers

Medium Voltage Metal-Enclosed Switches

Transformer Disconnects

Dry Type Distribution Transformers

Coil Data Nominal Current MA Nominal VA Sealed Single Pole Normally Open (SPNO) White Rodgers Q

Figure 1. Two and Three-phase MagneX.

Industrial Control Power Transformers Class MT

SECTION PANELBOARDS

30 KVA Transformer - 480V 3 Phase to 208Y/120V - NEMA 3R Enclosure - Copper Windings

AC Rectifiers for use with Armature Actuated Brakes. Product Overview. Full Wave. Half Wave. Combination Full and Half Wave. TOR-AC Full and Half Wave

2 SLR Series Line Reactors... 50

Mini Power-Zone Unit Substation Product Description. Product Description. Features. Typical Applications

MODEL 422 Submersible Pump Controller

HPS Fusion General Purpose Enclosed Transformer

Design Standard. Purpose: Design Standard:

diode led 24VDC MAGNETIC DIMMABLE DRIVER SPECIFICATION SHEET 24VDC OVERVIEW FEATURES

Non-Ventilated Automation Transformers 6

4" Motors and Controls

75 kva Transformer - 480V Delta Primary - 208Y/120 Wye-N Secondary - NEMA 3R - K-13 - Copper Winding

Bulletin 1497A Machine Tool Transformers

Locking-Type Mounting, Thermal Type K4500 Series

Dry Type Distribution Transformers

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

REVISIONS App PC. App Sud. App Thom TC 2014/03/25

UNDERSTANDING THE DOE 2016 IMPACT: ENERGY EFFICIENT TRANSFORMERS PRODUCT GUIDE

Solid-State Relays. Solid-State Relays. Features. Description. Overview

SELECTING AN ENERGY EFFICIENT TRANSFORMER AND UNDERSTANDING THE IMPACT

HUNTERSVILLE, NORTH CAROLINA USA. MAY Fax: Phone toll free:

Industrial Control Power Transformers

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Solid-State Relays. Solid-State Relays. Features. Description. Overview

PH250MQMJ CNTL 250VA 240X X240

TECHNICAL BROCHURE BC3WIRE-G2 R4

Transformer Disconnects

ASCO SERIES 185 Power Transfer Switches

MIRUS International Inc. TYPICAL SPECIFICATION ULLTRA & ULLTRA-H1E 31 Sun Pac Blvd., Brampton, Ontario, Canada L6S 5P6

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Pretest Module 21 Units 1-4 AC Generators & Three-Phase Motors

90 kva Transformer - 208Y Wye-N Primary Voltage - 230Y Wye-N Secondary Voltage - NEMA 3R

3 year warranty. (1) Treo Micro fiberglass, gunite fitting, 3/4 PVC. FLED-TM-W-PK10 (10) Treo Micros (WHITE) 80 NEW! Treo Micro fitting adapter

Dry Type Distribution Transformers

Bulletin 1497A Machine Tool Transformers

DLTC. lighting controls. transfer circuit for use with low-voltage down-lighting. features

HVW701 HVAC Drive with By-Pass

HOW TO ORDER SPECIFY AS SHOWN BELOW EXAMPLE #1

112.5 kva Isolation Transformer - 440V Delta Primary - 110V Delta Secondary - NEMA 3R

NEMA 1 ( IP23 ) NEMA 12 ( IP54 ) Spec-Tech Industrial Electric

Century Style Analog Panel Meters

12 CB30M SERIES UNITS INCLUDING ECB29 ELECTRIC HEAT

AT120A-E; AT140A-E; AT150A,B,D-F; AT160B; AT175A-D,F Transformers

HPS TITAN HPS TITAN. Three Phase. Single Phase

Isolating transformer ES710

A. Three-phase, oil filled self-cooled, padmounted transformers are installed outdoors on pads in the EWEB distribution system.

Miscellaneous. Unit Substation 600 Volts and Below. Sealed Mini Power-Zone Transformers Industrial Control

DC to AC Power Inverters

Multi-Pak Group Control

DC to AC Power Inverters

3. Coils shall be of molded construction

Capacitors. Individual & fixed bank. Individual & fixed capacitor banks. Low Voltage Network Quality

Machine Tool Industrial Control Transformers

CLARK PUBLIC UTILITIES TECHNICAL SPECIFICATIONS THREE-PHASE PADMOUNTED TRANSFORMERS

Engineered solutions for power and the environment

Engineering Information. Solenoid Valves Principles of Operation. Solenoid Valves. Direct Acting Valves (Figures 1A, 1B)

Electrical Design/Build Guide

Single-Phase Step Voltage Regulators

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

poollux Power plx-pw60 & plx-pw100

Transcription:

SECTION LOW VOLTAGE/ LIGHTING TRANSFORMERS General Purpose... 84 Buck - Boost... 85 Wiring Diagrams... 8

LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage Lighting A greater selection for your indoor & outdoor low voltage lighting projects Why Low Voltage? Acme s Low Voltage Lighting products provide a safe, long lasting, highly reliable power source; a perfect selection for landscape applications as well as interior use. Low voltage lighting is a creative medium with unlimited application possibilities. Low voltage lighting benefits include: Precision beam control More light intensity per watt Less radiated heat Greater efficiency Longer life Safer to use Easy installation A high return on end-user investment Acme Advantages More value Acme low voltage transformers are available in a wide range of options and models that are all UL listed for use indoors or outdoors. See inside back cover for warranty details. More Power Transformers in ratings of 100 through 1000 W; Group VI Buck Boost in.05 through 10 kva. More convenience Groups IV, V and VI transformers have copper lead wires for hardwiring. Circuit breakers for instant reset (except pool and spa and Buck Boost). No fumbling with fuses. Generous wiring compartment, too! More protection A full fault current carrying Faraday Shield (except Buck Boost) prevents 120 volts from reaching the 12 volt side, as required by UL-1571 and UL-1838. Features & Options The convenient Selection Guide on the facing page provides you with the data you need to select the product that best meets your requirement. Complete product selection data, dimensions and wiring diagrams are contained on the following pages. If you need help in your selection, or if you have questions, just call technical services at 1-800-334-5214. 82 ACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com

LOW VOLTAGE LIGHTING TRANSFORMERS & POWER SUPPLIES SELECTION GUIDE 1 2 3 4 5 7 8 9 10 11 TRANSFORMERS GROUP V GROUP VI Buck Boost Features/Options T1 T1 and T2 Catalog No. Catalog No. 100.05 Ratings through through (Watts, VA, kva) 1000 VA 10 kva Primary Input Secondary Output 120 Volts or 120 x 240 240 Volts Volts or 12 x 24 V Hardwired Primary Yes Yes Overload Protection: Primary Secondary Auto Thermal Reset Circuit Breakers Output Copper Copper Wiring Lead Wires Lead Wires UL Listed Yes Yes CSA Certified Yes Yes Faraday Shield Product Warranty Yes No No No 10 Years 10 Years UL-3R Indoor/Outdoor No Yes Enclosure ACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com 83

LOW VOLTAGE/ LIGHTING TRANSFORMERS & POWER SUPPLIES Low Voltage General Purpose Transformers FEATURES UL Listed, CSA Certified. UL class 180 C insulation system 115 C rise. 100, 150, 300, 00, 750, 1000 VA. UL Type 2 enclosure. 1 Phase, 0 Hz, 120 or 240 volt input. Keyhole slotted wall mounting brackets. 12 or 24 volt output. Input Auto-Thermal reset switch. Black finish. Bottom access. H Output circuit breaker. Fully encapsulated core and coil. Full fault current carrying Faraday Shield. Flexible copper leadwire terminations. Two 0.875 (2.2 cm) single knockouts each side. Two dual 0.875 (2.2 cm) and 1.125 (2.9 cm) knockouts on bottom cover. W D GROUP V 120 PRIMARY VOLTS 12 SECONDARY VOLTS, TWO WINDINGS, 1Ø, 0 Hz APPROX. DIMENSIONS APPROX. VA CATALOG NO. INCHES (CM.) SHIP WEIGHT CB RATING CB STYLE HEIGHT WIDTH DEPTH LBS. (KG.) 100 T17900S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 15 AMP Push To Reset Thermal Breaker 150 T17920S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 20 AMP Push To Reset Thermal Breaker 300 T17921S 11.8 (29.7) 4. (11.8) 4.57 (11.) 11 (5.0) 40 AMP Push To Reset Thermal Breaker 00 T17922S 11.8 (29.7) 4. (11.8) 4.57 (11.) 15 (.8) 0 AMP Magnetic Toggle On/Off Breaker 750 T17903S 11.8 (29.7) 4. (11.8) 4.57 (11.) 18 (8.2) 75 AMP Magnetic Toggle On/Off Breaker 1000 T17904S 11.93 (30.3) 5.41 (13.7) 5.20 (13.2) 2 (11.8) 100 AMP Magnetic Toggle On/Off Breaker 120 PRIMARY VOLTS 24 SECONDARY VOLTS, TWO WINDINGS, 1Ø, 0 Hz APPROX. DIMENSIONS APPROX. VA CATALOG NO. INCHES (CM.) SHIP WEIGHT CB RATING CB STYLE HEIGHT WIDTH DEPTH LBS. (KG.) 100 T17905S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 7 AMP Push To Reset Thermal Breaker 150 T17923S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 10 AMP Push To Reset Thermal Breaker 300 T17924S 11.8 (29.7) 4. (11.8) 4.57 (11.) 11 (5.0) 20 AMP Push To Reset Thermal Breaker 00 T17925S 11.8 (29.7) 4. (11.8) 4.57 (11.) 15 (.8) 40 AMP Push To Reset Thermal Breaker 750 T17908S 11.8 (29.7) 4. (11.8) 4.57 (11.) 18 (8.2) 50 AMP Push To Reset Thermal Breaker 1000 T17909S 11.93 (30.3) 5.41 (13.7) 5.20 (13.2) 2 (11.8) 50 AMP Magnetic Toggle On/Off Breaker 240 PRIMARY VOLTS 24 SECONDARY VOLTS, TWO WINDINGS, 1Ø, 0 Hz APPROX. DIMENSIONS APPROX. VA CATALOG NO. INCHES (CM.) SHIP WEIGHT CB RATING CB STYLE HEIGHT WIDTH DEPTH LBS. (KG.) 100 T17915S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 7 AMP Push To Reset Thermal Breaker 150 T17929S 9.01 (22.9) 4.08 (10.4) 3.88 (9.9) 7 (3.2) 10 AMP Push To Reset Thermal Breaker 300 T17930S 11.8 (29.7) 4. (11.8) 4.57 (11.) 11 (5.0) 20 AMP Push To Reset Thermal Breaker 00 T17931S 11.8 (29.7) 4. (11.8) 4.57 (11.) 15 (.8) 40 AMP Push To Reset Thermal Breaker 750 T17918S 11.8 (29.7) 4. (11.8) 4.57 (11.) 18 (8.2) 50 AMP Push To Reset Thermal Breaker 1000 T17919S 11.93 (30.3) 5.41 (13.7) 5.20 (13.2) 2 (11.8) 50 AMP Magnetic Toggle On/Off Breaker 84 ACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com

LOW VOLTAGE/ LIGHTING TRANSFORMERS& POWER SUPPLIES Buck-Boost Transformers H The No-Frills Low Voltage Lighting Buck-Boost Transformers offer a nofrills approach to low voltage lighting. (See Chart Below) A typical Buck- Boost application is 120 volts in and 12 volts out for low voltage lighting or control circuitry. In most applications, this low voltage isolation transformer is field connected as an autotransformer. For more information on Buck- Boost Transformers, refer to the next section in this catalog. D W GROUP VI 120 x 240 VOLT 12/24 VOLT 1Ø, 0 Hz INSULATING SECONDARY MAXIMUM APPROX. DIMENSIONS APPROX. CATALOG TRANSFORMER CURRENT INCHES (CM.) NET WEIGHT NUMBER RATING HEIGHT WIDTH DEPTH LBS. (KG.) T181047 0.05 kva 4.1 2.08.38 (1.2) 3.19 (8.1) 3.00 (7.) 4 (1.8) T181048 0.10 kva 8.32 4.1.2 (1.8) 3.75 (9.5) 3.2 (9.2) 5 (2.3) T181049 0.15 kva 12.52.25 7.12 (18.1) 3.75 (9.5) 3.2 (9.2) 7 (3.2) T181050 0.25 kva 20.80 10.40 8.8 (22.0) 4.08 (10.4) 3.88 (9.9) 10 (4.5) T181051 0.50 kva 41.0 20.80 9.0 (23.0) 4.37 (11.1) 4.20 (10.7) 15 (.8) T181052 0.75 kva 2.50 31.25 9.8 (24.) 4.75 (12.1) 4.51 (11.5) 19 (8.) T11183 1.00 kva 83.20 41.0 10.50 (2.7) 5.50 (14.0) 5.13 (13.0) 24 (10.9) T11184 1.50 kva 125.00 2.50 11.2 (29.5) 5.50 (14.0) 5.13 (13.0) 30 (13.) T11185 2.00 kva 1.00 83.20 13.00 (33.0) 5.50 (14.0) 5.13 (13.0) 38 (17.2) T1118 3.00 kva 250.00 125.00 11.50 (29.2) 10.31 (2.2) 7.13 (18.1) 55 (24.9) T11187 5.00 kva 41.00 208.00 14.38 (3.5) 10.31 (2.2) 7.13 (18.1) 75 (34.0) T21188 7.50 kva 25.00 312.50 21.19 (53.8) 13.50 (34.3) 10.84 (27.5) 125 (5.7) T21189 10.00 kva 833.00 41.0 21.19 (53.8) 13.50 (34.3) 10.84 (27.5) 10 (72.) ACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com 85

LOW VOLTAGE/ LIGHTING TRANSFORMERS& POWER SUPPLIES Low Voltage Lighting Wiring Diagrams GROUP V GROUP VI X3 X4 X3 X4 X3 X4 X3 X4 VOLTAGE DROP CHART Voltage Life Expectancy % of Rated at Lamp of Lamp Candlepower 13.2 2/3 Rated Life 350 12. 3/4 Rated Life 180 12.0 As Rated 100 11.5 2X Rated Life 80 11.0 3X Rated Life 74 10.5 5X Rated Life 5 10.0 9X Rated Life 50 CABLE SIZE CONSTANT CHART Cable Cable Size Size Constant #18 1380 #1 2200 #14 3500 #12 7500 #10 11,920 #8 18,90 # 30,150 VOLTAGE DROP FORMULA Total Watts on Cable X Length of Run Cable Size Constant = Voltage Drop 8 ACME ELECTRIC MILWAUKEE, WI 800.334.5214 acmetransformer.com