UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

Similar documents
TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

SPICES BOARD (Ministry of Commerce & Industry, Govt. of India) Palarivattom.P.O. N H By Pass Kochi

Master Plus kva

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical Data Sheets

Technical Data Sheets

Master DIALOG INDUSTRY RANGE

MKN-DSP SERIES - THREE PHASE

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

POWER kva

POWER kva

UPS Multi Sentry 10-20kVA

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Technical Data Sheets

Master Plus kva

POWERTRONIX QUASAR 5-40 KVA

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Technical Data Sheets

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL DATA SHEET KVA UPS Systemss

Master MPS kva kva 3:1 3:3 VFI TYPE

Technical Data Sheets

PowerValue 11/31 T kva

Master MPS kva kva 3:1 3:3 VFI TYPE

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

EFFEKTA Power Supplies

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

ConceptpowerTM Modular kVA

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Technical Data Sheets

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Technical Data Sheets

Supply, testing, installation and commissioning of 5 ky A UPS system as per the following specification:

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TLE Series UPS 400/500 kw With eboost Technology

Onfiniti. 1 Phase UPS

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Industrial PFC UPS System

Master MPS kva kva 3:1 3:3 VFI TYPE

Technical data sheets

HAIRF UPS. X5 Series KVA

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

TLE Series UPS 160/200/225/250 kw with eboost Technology

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

Standard specification Galaxy PWi, three-phase, 10 to 200 kva

INDIAN INSTITUTE OF TECHNOLOGY, KANPUR DEPARTMENT OF ELECTRICAL ENGINEERING

SENTINEL VA

.3 Section Waste Management and Disposal.

Illuminator Series CR NEMA 3R

TLE Series UPS 750/1000 kw With eboost Technology

NB NB 1511 NB NB 4031 TRUE ON-LINE DOUBLE CONVERSION UPS

Technical Specification SENTINEL PRO

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical data sheets

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

1.1 GENERAL CHARACTERISTICS

Aurora Single Phase Emergency Lighting Inverters

Three Phase UPS Systems Range: 10 to 500kVA

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Tender Technical Specification. For Three phase UPS, on line double conversion (VFI) 120 kva Modular UPS

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

MGE TM Galaxy TM 6000 : Specification guide. Single UPS, three-phase, 250 to 600 kva

TECHNICAL SPECIFICATIONS FOR. 3/5/6/8/10 kva Single phase in/out Single or parallel UNINTERRUPTIBLE POWER SUPPLY SYSTEMS

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

Power+ CLASSIC. 20/30 kva, 3x208 Vac

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

YOUR POWER IN SAFE HANDS. E Series UPS

TECHNICAL SPECIFICATIONS OF 2 KVA POWER CONDITIONING UNIT

Marketing Management Team of Europe

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Transcription:

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata- 700106 NOTICE INVITING QUOTATION Sealed Quotations are invited from reputed suppliers or manufacture for the 60 KVA UPS for XRD System in Clean Room Block at CRNN. 1 N.I.Q No 2 Name of Work Dir/170/XRD/60 KVA UPS/CRNN(2016) Date: 04.03.16 Supply of 60 KVA UPS for XRD System at Clean Room block of Technology Campus (Acharya Prafulla Chandra Roy Siksha Prangan), Salt Lake. 3 Time of completion Within 1 month from issuing Order. 4 Eligibility Criteria Appendix A4 5. Technical Specification Annexure D 6 Last date of Application for participating in bid 29/07/2016 ( up to 2.00 PM) 7 Last date of Collection of Quotation Papers 02/08/2016 ( up to 2.00 PM) 8 Last date of dropping of Quotation 05/08/2016 ( up to 2.00 PM) 9 Date of opening of Quotation - For details enquiry & further correspondence feel free to contract CRNN office at any working day between 11.00 am to 4.00pm. N. B. The authority reserves the right to reject any or all tenders/quotation without assigning any reason what so ever. Director, CRNN

APPENDIX-A4 University of Calcutta has procured X-Ray Diffractometer (Model: SmartLab 9KW, Make Rigaku, Japan) for its Center for Research in Nanoscience and Nanotechnology, Saltlake, JD-2, Sector-3, Kolkata-98. Quotations are invited from bonafide vendors for an online UPS systems with 60 KVA capacity to be installed at the same address for the suppling power to the said X-Ray diffractometer. The details of the tender specification are given herewith: 1) Eligibility criteria for participation in the Tender : A) The Bids shall be submitted by only the OEM (Original Equipment Manufacturer) or authorized sales and service provider of OEM in case OEM is not participating. Declaration from OEM specific to this tender in this regard needs to be submitted. B) The tenderer must take the responsibility for the delivery, installation and commisioning of the product at the site specified during the order procress and at time specified during the order procress. Delay in installation and /or commissioning will be subject to penalize. C) Manufacturer should be ISO 9001:2008 Certified, ISO 14001:2004 certified. D) The vendor, to whom the order shall be placed is required to provide necessary certificate(s) from ERTL/ETDC/CPRI for the particular instrument at the time of delivery. E) Manufacturer should have factory and R&D in India. Manufacturer is required to provide the full details of factory address in India. F) The Bidder shall be an established UPS Manufacturing company registered under the Companies Act, 1956 having operations in India for the last three years as on 31.12.2014 (Certificate of Incorporation) and shall have their registered offices in West Bengal and submit valid documentary proof of Certificate of incorporation Trade License of West Bengal G) The Bidder should have executed (completed) at least two similar or higher rating orders in or around Kolkata at any Govt. Department / Educational & Research Institutes / PSU / Board / Council or similar. The UPS should have installed alongwith same kind of load which is running successfully atleast for a period of not less than 2 years. H) Copies of suitable documents like Purchase Orders, etc. for verification of the order values and work completion / customer satisfaction certificates (or similar documents) from customers against the same orders for verifying successful completion of the orders must be submitted as evidences. I) The Bidder should have delivered and installed at least two similar UPS equipment to support high value sophisticated scientific instruments at reputed research institutions/universities in India J) The manufacturer should have WB sales tax registration for more than 5 years with same company name. A copy of the certificate should be enclosed with the offer. 2) Technical specifications : The details of the technical Specifications for 60 KVA online UPS is given in ANNEXURE-D.

ANNEXURE-D Technical Specifications for 60 KVA online UPS suitable for XRD system Description Specification CAPACITY 60 KVA TECHNOLOGY Should be digitally controlled, IGBT based double conversion Online VFI according to IEC62040-3 specification Input & output EMI Filter should be provided Built-in Isolation Transformer should be provided on the Inverter output (No external IT will be excepted) Input Rated voltage 400 VAC three-phase + N Voltage Range ± 20% at full load Frequency Range 45 to 65 Hz Power Factor > 0.95 Power Walk-in Progressive in 10 seconds By Pass (Static & manual) Rated Voltage 400 VAC Number of Phases 3 + N Permitted voltage range ± 15% (selectable from ± 10% to ± 25% from front panel) Rated Frequency 50/60 Hz Permitted Frequency Range ± 2% (selectable from ± 1% to ± 5% from front panel) Batteries Type Sealed Maintenance Free Lead Acid type 12V Make Exide Power Safe / Amara Raja Quanta Backup Time ½ Hour Battery capacity Should not be less than 46000 VAH Battery Rating should be specified by the vendor alongwith the qty offered Recharge Time 4-6 Hrs. Temperature Control & Battery Charging The system should compensate for any variations in temperature while recharging the batteries. The recharge voltage should be temperature depended-the higher the temperature, the lower the recharge voltage should be Automatic battery test The UPS should carry out battery tests automatically. The period between and the duration of the test should be configured via the control panel, or the test can be completely deactivated. Current ripple In normal operating condition and with the battery charged, the current ripple should be nearly zero.

Output Number of Phases 3 + N Rated Voltage 380 400 415 V AC Selectable Power Factor 0.8 Voltage setting Should be via Control Panel VTHD <2% for Linear load & <3% for Non-Linear load Crest factor (Ipeak/Irms) 3 : 1 Waveform Sinewave Voltage stability at steady ± 1% state Voltage stability at dynamic ± 5% state Frequency 50/60 Hz selectable Frequency stability with the ± 2% (configurable via the control panel ±1-5%) Inverter in Synchronisation with the bypass supply Frequency stability with the ± 0.05% Inverter out of Synchronisation with the bypass supply Overload 110% for 1 Hr., 125% for 10 mins., 150% for 1 min. Overall efficiency at full Should be > 90% load Protection Back feed protection The back feed protection should be installed in series with bypass SCRs. (When the mains power supply fails, and in the event of fault occurring with the SCRs, the back feed protection device prevents any current that could cause an electric shock from back feeding to the incoming power supply connections. Further more, when a mains supply failure occurs, an electromagnetic switch should positioned at the rectifier input opens, for preventing any current back feed on to the electrical system prior to this point.) Normal Protection Input, output, rectifier input, battery fuse, bypass fuse, short circuit etc. Thermal on system, rectifier, bypass and inverter. Protection against prolonged battery discharge Environmental Conditions Operating temp. for UPS 0 40º C Relative humidity <95% non condensing Noise <60dBA at 1 m Mechanical Data Protection Degree of the IP 20 cabinet Cable input Display & Software Minimum List of information should be appeared on the LCD Display Should be Bottom entry Input Voltage, Frequency, Power By-pass Voltage, Frequency Output Voltage, Frequency, Power, Peak Power Battery Voltage, Battery Peak Pulse Current Battery discharge current Inverter Input Voltage Internal temperature (system / converter / Bypass/ Inverter/magnetic Components) Inverter Operation Time By-pass operation time

Battery Operation Time No. of battery interventions No. of complete discharges Date of first activation Commands Battery Test, Display Contrast, By-pass Off, End discharge prealarm, System Off Customization Output Voltage, Output Voltage Compensation, Batteries, End discharge pre-alarm, Auto off, By-pass voltage tolerance, Bypass frequency tolerance Communication & Software RS232 serial port, Advanced, Multi-platform Communication, for all operating systems and network environments; shutdown & monitoring software Other mandatory points: Reliability of the system Mimic Display Self Diagnostics Input Phase Reversal Auto restart facility The total system (Charger & Inverter section) should be controlled by redundant microprocessor system. If a fault occurred to either of the microprocessors, the power supply to the protected load should not be interrupted Mimic diagram should be provided to know the status of the rectifier, inverter, battery and output. The system should provide EVENT RECORDING facility. The system should able to store atleast last 100 events i.e. input voltage variation or out of tolerance, operating conditions of the system at any time, its include cause of the fault and should be able to display the name of the faulty area in terms of rectifier fault, inverter fault, battery contactor fault etc. through code. All events should be readable from front panel LCD/LED of the system and also from PC/Laptop through the RS 232 communication interface port. In the event of any phase reversal in the input power source, the system should neither trip nor go to battery discharge mode. It should works on mains but with fault alarm indicating input phase reversal. This should be an inbuilt feature of the system design. The UPS should configured to automatically restart after a mains supply failure or after the batteries have become fully discharged In the event of an emergency the UPS can be completely shutdown by an external command EPO (Emergency Power Off) Standards Should complies the following safety & EMC Standards : Low Voltage Directive 2006/95/EC: Test Standards CEI EN 62040-1 EMC Directive 2004/108/EC: Test Standards EN62040-2 Important The Technical Specification along with Credentials & Eligibility should be certified and verified as per the tender notice.