POWER kva

Similar documents
POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

TECHNICAL DATA SHEET KVA UPS Systemss

EFFEKTA Power Supplies

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

POWERTRONIX QUASAR 5-40 KVA

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Technical Data Sheets

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical data sheets

PowerValue 11/31 T kva

Technical Data Sheets

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

MKN-DSP SERIES - THREE PHASE

Industrial PFC UPS System

Three Phase UPS Systems Range: 10 to 500kVA

PowerWave 33 Efficient power protection for today s IT and process-related work environments

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

1.1 GENERAL CHARACTERISTICS

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TLE Series UPS 400/500 kw With eboost Technology

Marketing Management Team of Europe

Liebert. FP 50Z kva

ConceptpowerTM Modular kVA

Master DIALOG INDUSTRY RANGE

TLE Series UPS 160/200/225/250 kw with eboost Technology

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

PowerWAVE EL. Technical Specification. (Single phase 500 VA 30 kva. Three phase kva)

PowerScale kva Technical Specifications

TECHNICAL SPECIFICATIONS

PowerScale TECHNICAL SPECIFICATIONS

EATON 9315 UPS 200 TO 300 KVA Specifications

MASTERYS IP+ 10 to 80 kva

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

POWER+ CLASSIC 20/30 KVA, 3X208 VAC WITH INTERNAL BATTERIES. GAMATRONIC, A SolarEdge Division

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TLE Series UPS 750/1000 kw With eboost Technology

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Cobra 3 Stand-By Emergency Central Lighting Inverter (CLI) Technical Specifications

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Power+ CLASSIC. 20/30 kva, 3x208 Vac

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

Technical data sheets

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

Liebert Hipluse U UPS;80-400kVA; 380/400/415V Detailed Specification

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Power Lynx 3 Uninterruptible Power System (UPS) Technical Specifications

Defender Mini Online Emergency Central Lighting Inverter (CLI) Technical Specifications

TOSHIBA /20/25/30/50kVA Internal Battery GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY

Illuminator Series CR NEMA 3R

Liebert Hipulse E The High-ECO-Availability UPS. AC Power Systems

Industrial Chargers and

Liebert GXT & 6000VA RT230 Rack-Tower models GUIDE SPECIFICATIONS 1.0 GENERAL

magellan commercial UPS solutions Magellan Power Modular - Flexible UPS

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

3. MAJOR SYSTEM COMPONENTS Emergency Lighting Power System shall consist of the following major subsystems:

Fortress 1 Outdoor Emergency Central Lighting Inverter (CLI) Technical Specifications

Technical Specification SENTINEL PRO

Green Power 2.0 MASTERYS GP

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

Liebert APM UPS. For a 30 to 150 kva / kw (50 or 60Hz) Modular Digital Uninterruptible Power Supply (UPS) System. V nd February 2010

Three Phase UPS Systems

Fortress 3 Harsh. Harsh Environment. Emergency Central Lighting Inverter (CLI) Technical Specifications

G V Series UNINTERRUPTIBLE POWER SYSTEMS. Phone: Fax: Web:

UPSaver 20012,800KW. Efficiency. Scalability. Product Highlights

Product Specifications

60 to 160 kva.

Master Plus kva

Master Plus kva

DPP/3DPP. Digital ProcessPower UPS INDUSTRIAL PWM UNINTERRUPTIBLE POWER SUPPLY SYSTEM SINGLE PHASE THREE PHASE

AME. Rectifier - Battery charger. Industrial applications: Key features:

n Lower energy costs and carbon footprint n Cooler operation extends internal component life n High input power factor of 0.99

UPS Multi Sentry 10-20kVA

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

MGE TM Galaxy TM 7000 GFC

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

Liebert GXT & 10000VA RT208 Rack-Tower models, Dual Inverter GUIDE SPECIFICATIONS 1.0 GENERAL

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Transcription:

TECHNICAL DATA SHEET B9000 FXS 60-80-100-125-160kVA +44 (0)20 8868 3732 GENERAL INFORMATION UPS Type ON LINE Double Conversion Nominal output power (Cos φ 0,8) kva 60 80 100 125 160 Nominal output power (Cos φ1,0) kw 48 64 80 100 128 @25 load >88 Efficiency (AC AC) @50 load >90 (ON LINE - Double Conversion) @75 load >92 @100 load >93 Efficiency (AC AC) (Eco Mode) > 98 Heat dissipation at nominal load and voltage kw 3.8 4.8 6,0 7,5 9,6 kcal/h 3.3 4.2 5,2 6,5 8,3 UPS ambient temperature C 0 40 BATTERY ambient temperature C 0 +25 UPS storage temperature C -10 +70 BATTERY storage temperature C -10 +60 Relative humidity (non condensing) < 95 Altitude m < 1000 (above sea level) Power derating for altitude > 1000 m According to IEC62040-3, 1 power derating every 100m above 1000m, up to max 2000m Ventilation Forced Requested cooling air volume m 3 /h 1600 1800 2100 2300 2500 Audible noise level (according to IEC EN 62040-3) db < 60 Standard battery type lead acid n cells 300 312 adjustable Protection degree IP 20 Electromagnetic compatibility EMI According to IEC EN 62040-2 (CE marking) Safety IEC EN 62040-1 Test and performance IEC EN 62040-3 Paint RAL 7016 Accessibility Front and top access for service Installation Also against wall and/or side-by-side Dimensions mm W = 815 D = 865 H = 1705 Weight (without battery) kg 570 600 630 662 720 Static load (without battery) kg/m 2 948 998 1048 1101 1198

Input/Output cable connection Bottom Side (Top Side on Request) Transport Base provided for forklift handling Transport mechanical stress According to IEC EN 62040-3 Design standards IEC EN 62040 ISO 9001:2008 Free contact interface Standard per remotizzare i seguenti contatti: EPO MBCB BCB DIESEL MODE Serial communication interface Standard: RS232 - USB Optional: RS485 (Mod-Bus protocol) Parallel configuration (optional) Up to 5+1 (redundant parallel) Up to 6 (power parallel) BLOCK DIAGRAM 1. Input mains (separate for by-pass and rectifier) 2. Rectifier and battery charger 3. External battery 4. Inverter 5. Emergency line (by-pass) with optional backfeed contactor 6. Inverter (SSI) and by-pass (SSB) static switch

UPS INPUT: RECTIFIER AND BATTERY CHARGER Input Three-phase Nominal input voltage Vac 400-20/+15 Input frequency 50 60 ±5 Input power factor > 0.99 @25 load <10 Input current THD at nominal @50 load <7 voltage and THDV <0,5 @75 load <5 @100 load <3 DC output voltage accuracy ±1 DC output voltage ripple rms 1 Battery recharging characteristic IU (DIN 41773) Maximum recharging current - at nominal load A 15 15 15 20 20 - with DCM function (max current) 50 50 100 100 100 AC-DC converter type PFC IGBT Input protection Fuses Nominal current absorbed from mains (at nominal load and battery charged) A 75 100 125 156 200 Maximum current absorbed from mains (at nom. load and max. recharging current) A 94 126 157 196 252 Sectable walk-in sec Sectable from 5 to 30 Sectable hold-off sec Sectable from 1 to 300 BATTERY Type (standard) other on request Lead Sealed maintenance free Number of Cells 300 312 adjustable Floating voltage at 25 C Vdc 680 for 300 cells, 707 for 312 cells (adjustable) Minimum discharge voltage Vdc 496 for 300 cells, 516 for 312 cells (adjustable) Inverter input current (at nominal Load) kw 50 68 84 105 135 Inverter input current (at nominal load-minimum Vdc) A 102 136 170 212 272 Battery Protection (external to the UPS) Wall mounted fused switch box on request Battery Test Included as standard

UPS OUTPUT: INVERTER Inverter Bridge IGBT (High Frequency PWM) Nominal output power (Cosφ 0,8) kva 60 80 100 125 160 Nominal output power (Cosφ 1,0) kw 48 64 80 100 128 Efficiency (DC AC) @25 load @50 load @75 load @100 load Output Three-phase + Neutral Nominal Output Voltage (selectable) Vac 380-400-415 Output Voltage Stability - Static (Balanced Load) ±1 - Static (Unbalanced Load) ±2 - Dynamic (Step Load 20 100 20) ±5 - Output Volt. Recovery Time(after step load) <20 ms - IEC EN 62040-3 Class 1 Phase Angle Accuracy - Balanced Load - 100 Unbalanced Load ± 1 ±1 Output Frequency (selectable) 50-60 Output Frequency Stability - Free Running Quartz Oscillator - Inverter Sync. with Mains - Slew rate /s 90 92 94 95 ± 0,001 ± 2 (other on request) 1 Nominal Output Current (@ 400 Vac output) - Cos φ 0,8 A 80 116 145 180 232 - Cos φ1 70 93 115 145 186 10 min >100 125 Overload Capability 1 min >125 150 10 s >150 199 100ms at 200 Short Circuit Current A 140 186 230 290 370 Short Circuit Characteristic Elect. short circuit protection, current limited at 2 times nominal current. Automatic stop after 5 seconds Selectivity Within ½ cycle (Fuse gl 20 In) Output Waveform Sinusoidal Output Harmonic Distortion - Linear Load <1 - Non Linear Load <5 - IEC EN 62040-3 Fully compliant Max Crest Factor without derating 3 : 1

UPS OUTPUT: BY PASS Automatic static by-pass Electronic Thyristor Switch Protection Fuses Bypass Vac Three-phase + Neutral Nominal Voltage (selectable) Vac 380-400-415 ±10 Nominal Frequency (selectable) 50-60 ± (1 5) adjustable Transfer mode Without break Transfer inverter automatic bypass In case of : - Static Switch test - Inverter test - Inverter not operating - Battery end of discharge Retransfer automatic bypass inverter - Automatic - Block on bypass after 6 transfers within 2 minutes, reset by front panel Overload Capability 150 Continuously 1000 For 1 Cycle Manual By-Pass Standard: - Electronically controlled - No break

OPTIONS 1. BATTERY TEMPERATURE VOLTAGE COMPENSATION 2. INSULATION TRANSFORMER ON BY-PASS 3. VOLTAGE ADAPTATION AUTO-TRANSFORMERS 4. RELAY CARD (Eight signals Alarms/Statuses), Free relay contact 5. SERIAL INTERFACE RS-485 (MOD-BUS protocol) 6. SNMP ADAPTER 7. REMOTE MONITORING PANEL 8. PARALLEL CARD INTERFACE KIT 9. EXTERNAL BATTERY CABINET 10. WALL MOUNTED FUSED SWITCH BOX 11. IN/OUT TOP CABLE ENTRY 12. SPECIAL PAINT 13. LOAD-SYNC BUS CARD INTERFACE KIT 14. BACK FEED PROTECTION OTHER SOFTWARE SELECTABLE FEATURES 1. DIESEL-MODE 2. ECO-MODE 3. BOOST-CHARGE 4. RECTIFIER WALK-IN TIME 5. RECTIFIER DELAY ON STARTUP (HOLD-OFF TIME) 6. FREQUENCY CONVERTER MODE 7. DCM FUNCTION