THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

Similar documents
CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

Effect of Nanofluid on Friction Factor of Pipe and Pipe Fittings: Part I - Effect of Aluminum Oxide Nanofluid

Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

CFD analysis of triple concentric tube heat exchanger

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

A REVIEW ON INVESTIGATION OF HELICAL COIL HEAT EXCHANGER

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

International Journal of Advance Engineering and Research Development

Comparative Numerical Analysis of Straight and Conical Coil Heat Exchanger

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

CFD ANALYSIS OF DOUBLE HELICAL PIPE PARALLEL& COUNTER FLOW HEAT EXCHANGER

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

NUMERICAL SIMULATION OF HELICAL COIL TUBE IN TUBE HEAT EXCHANGER WITH BAFFLES

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

Design, Fabrication and Testing of helical tube in tube coil heat exachanger

PERFORMANCE ANALYSIS OF DIFFERENT HEAT EXCHANGER DESIGN USING CFD SIMULATION 1 KVENUMADHAV 2 SUDHANSHU KUMAR

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Automation of Optimal Design of Air Preheater s Corrugated Heating Elements using CFD

International Journal of World Research, Vol: I Issue XXXVII, January 2017 Print ISSN: X

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

Comparison of Swirl, Turbulence Generating Devices in Compression ignition Engine

International Journal of Engineering Research and General Science Volume 5, Issue 3, May-June, 2017 ISSN

ADVANCES in NATURAL and APPLIED SCIENCES

CFD Analysis of Heat Transfer Prediction for Corrugated Shell & Tube Heat Exchanger

IJESR/Oct 2012/ Volume-2/Issue-10/Article No-12/ ISSN International Journal of Engineering & Science Research

CFD Integrated Optimum Design and Prototyping of Shell and Tube Heat Exchanger

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

CFD ANALYSIS OF PRESSURE DROP CHARACTERISTICS OF BUTTERFLY AND DUAL PLATE CHECK VALVE

Investigation of Comparison of Three Different Tube Bundles of Heat Exchanger

CRITICAL ASSESSMENT OF LITERATURE IN THE FIELD OF ENHANCED HEAT TRANSFER TECHNIQUES

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

Design and Fabrication of Shell and Tube Type Heat Exchanger and Performance Analysis

CFD Analysis on Shell and Coiled Tube Heat Exchanger for Heat Transfer Augmentation Due to Air Bubbles Injection

HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

Abstract In this study the heat transfer characteristics inside a rectangular duct with circular, rectangular, drop

Design and experimental analysis of pipe in pipe heat exchanger

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

Numerical Simulation on Erosion of Drain Valve Liangliang Xu1,a, Zhengdong Wang2,b, Xinhai Yu3,c, Cong Zeng4,d

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

PERFORMANCE ANALYSIS ON DOUBLE PIPE HEAT EXCHANGER USING WIRE COILED AND PIN WIRE COILED TURBULATOR INSERTS

SINGLE-PHASE CONVECTIVE HEAT TRANSFER AND PRESSURE DROP COEFFICIENTS IN CONCENTRIC ANNULI

CFD ANALYSIS ON LOUVERED FIN

Exhaust Gas Waste Heat Recovery and Utilization System in IC Engine

Experimental Investigation on Turbulent Flow Heat Transfer in a Horizontal Circular Pipe using Coil and Twisted Tape Inserts

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR AND NANOFLUID

Performance Calculation of Vehicle Radiator Group using CFD

The Practical Uses of Computational Fluid Dynamics Not Just a Pretty Picture

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

COLD PLATE SOFTWARE PROGRAM ANALYZES AIRCRAFT

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

CFD ANALYSIS OF FLUID FLOW AND HEAT TRANSFER IN A SINGLE TUBE-FIN ARRANGEMENT OF AN AUTOMOTIVE RADIATOR

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

Chapter 7: Thermal Study of Transmission Gearbox

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

Design of Shell and Tube Type Heat Exchanger using CFD Tools

Numerical Analysis of Compact Heat Exchanger for Flow Distribution

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

DESIGN OPTIMIZATION OF SHELL AND TUBE HEAT EXCHANGER FOR OIL COOLER BY COMSOL MULTIPHYSIS

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

CFD Analysis for Designing Fluid Passages of High Pressure Reciprocating Pump

2008 International ANSYS Conference

Fig 2: Grid arrangements for axis-symmetric Rocket nozzle.

I, DESIGN OF A TEMPERATURE CONTROL SYSTEM USING MATLAB FOR MILK PROCESS PLANT & P.

THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

COMPRESSIBLE FLOW ANALYSIS IN A CLUTCH PISTON CHAMBER

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

Design and Performance Study of Shell and Tube Heat Exchanger with Single Segmental Baffle Having Perpendicular & Parallel-Cut Orientation.

Thermal Stress Analysis of Diesel Engine Piston

Impacts of Short Tube Orifice Flow and Geometrical Parameters on Flow Discharge Coefficient Characteristics

Numerical and Experimental Investigations of Heat Transfer in Double Pipe Heat Exchangers with Inner and Annular Twisted Tape

Experimental Study of Heat Transfer Enhancement in Tube in Tube Heat Exchanger Using Corrugated tube and Twisted Tape

Thermal Analysis Of Counter Flow Shell And Tube Heat Exchanger

Heat Transfer Enhancement In Pipe With Passive Enhancement Technique

TEMPERATURE APPROACH OPTIMIZATION IN THE DOUBLE PIPE HEAT EXCHANGER WITH GROOVE

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

An Experimental Investigation for the Rate of Heat Transfer in Double Pipe Heat Exchanger with Fins on Inside Surface of Internal Tube

Parametric Study on Flow and Heat Transfer Performance of Multi-Flow Spiral-Wound Heat Exchanger

ANALYSIS OF BLADES OF AXIAL FLOW FAN USING ANSYS. Mahajan Vandana N.,* Shekhawat Sanjay P.

Design & Analysis of Exhaust Heat Recovery System

Transcription:

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER A. RESHMA P.G Scholar, Thermal Engineering, Aditya Engineering College, Surampalem M.SREENIVASA REDDY Professor, Mechanical Department, Aditya Engineering College, Surampalem V.SRINIVASA RAO Associate Professor, Mechanical Department, Aditya Engineering College, Surampalem ABSTRACT The analysis of temperature distribution is considered in this paper by using a helically grooved coil in concentric tube heat exchanger. As the purpose of heat exchangers are increasing this paper deals about the theoretical and economical analysis by considering the helically grooved coil as inlet pipe with different materials such as aluminium, copper, carbon steels by maintaining the same inlet and outlet fluids with same velocities for all the materials. Comparisons have been taken by considering the flow as turbulent in the heat exchanger. The inner tube was helically grooved in which the area can be extended. The complete analysis is done by using ANSYS workbench. Heat transfer rate and temperature distribution are discussed K e y words: Helical coil, Convective heat transfer, unstable flow, Transient heat transfer, concentric tube heat exchanger. Nomenclature: Ai C k Q T surface area of inner tube Specific heat (J/Kg-K) Thermal conductivity(w/m-k) heat transfer rate (KW) Temperature (K) Introduction Heat exchangers are the common equipment which are having major applications in power generation plants, many chemical industries, production of solar energy, for processing of food and also other energy intensive industries The design of an efficient heat exchanger had always been important to equipment designers. Due to their compact structure corrugated pipes are one of the method to increase heat transfer improvement technique and so these are used in industrial applications. As the effectiveness depends upon the rate of heat transfer, the effectiveness is directly proportional to the surface area by which the heat transfer takes place. Therefore, the heat transfer rate can be maximize by increasing the surface area of the tube such as by adding twisted tapes, by arranging additional surfaces by means of corrugation in it. In this paper, the helically grooved coil tube is considered as the inner tube to increase the surface area in concentric tube heat 32

exchanger. Due to the helically groove in the coil the surface area is increased by having a turbulent flow by which the heat transfer rate is increased. Comparisons are taken to the helically grooved coil inlet pipe by changing the inlet materials of the pipe. As aluminium, copper and carbon steel are good in thermal conductivity and in other properties these are considered as inner pipe materials and steel is considered as the material for outer pipe. Vapour is used as inlet fluids where the water is used as the outlet fluid. The thermal analysis and temperature distribution is compared for all the cases and differences are considered. Literature: By twisting the tube the alteration of the flow can be varied by centrifugal forces stated by zachar as many studies were conducted to study heat transfer rate of coiled heat exchangers in laminar disorderly flows and modified twisted tapes were enhanced in order to increase the heat transfer by considering spirally corrugated wall. Many authors investigated experimentally the turbulent flow at dissimilar prandtl numbers and also turbulent forced convection heat transfer of nano fluids by twisted tapes. Depending upon the different flow zones it became highly important to increase heat transfer rate by many active techniques for various types of pipes by various methods. In case of passive techniques heat transfer can be increased by corrugation or by considering helical pipes and are investigated through laminar forced convection and thermal radiation in helical pipe explained by B. Zheng In order to increase the effectiveness of heat exchangers the study is also considered with nano fluids and verified the heat transfer rate is increased by adding the blocks to the walls of the tubes by which the surface of the pipe can be extended. The assumption of friction factors and heat transfer coefficients can increased by corrugated tubes combined with twisted tapes was experimentally given by V. Zimparov. Heat transfer and pressure drop in helically dimpled tubes and mixed convection heat transfer and isothermal pressure drop in corrugated tubes for laminar and transient flow. The friction factor and heat transfer rate were numerically analysed and calculated by considering nano fluids in order to increase the heat transfer rate. Corrugated coiled tubes were considered and experimental analysis, is performed by the multiple convective heat transfer in order to increase the heat transfer rate in a helically coiled wall corrugated tube. Forced convection was also discussed to compare the factors like friction factor and Reynolds number with different corrugation ratios. In order to increase the heat transfer rate in heat exchangers twisted oval tubes and also corrugated tubes were also discussed by using CFD in 3D. Amol Andhare investigated the performance of a shell and coil heat exchanger by considering helical pipes in it with counterflow in which the convective heat transfer is calculated by using Wilson plots and the process runs by considering curvature to pitch ratio. In this work the helically grooved coil is considered as inner pipe of the concentric tube heat exchanger in which the dimensions are considered from the base paper and the heat exchanger is designed and the comparisons are taken for the different materials considered. 33

Geometry of the file: In this paper by using Rhinoceros 4.0 software the design of the geometry is done and the design is completed by various commands and is imported to the tool of Ansys workbench15 and by choosing option Fluid flow (Fluent). Analysis: The design geometry was labelled as various cases were considered for the material of the flow inside the pipe. In the meshing model of fluent panel the imported geometry is finely meshed. After that the boundary conditions were specified by naming the boundary, wall, inlet for inner and outer pipes and outlet for inner and outer pipes has to be specified in the meshing window. In the transient state the study of heat exchanger takes place by considering the flow of fluid as turbulent. The design model selected were energy k-є(2-eqn) in the heat exchanger. Velocity of the fluid will be same for all the cases and can be obtained heat transfer analysis through those equations. The flow of the fluid in the heat exchanger is considered as parallel flow in the heat exchanger and the analysis was analyzed by Ansys Fluent. Results and discussions: Comparing the obtained results of the helically grooved coil with the three inner materials and they are obtained as follows: Fig. 1 represents the temperature distribution in a helically grooved coil in which the inner material of the pipe is taken as aluminium and the outer pipe is steel in which air is considered as internal fluid and water is considered as external fluid. The temperature drops from 473K to 326K. The fig represents the contours at static temperature at certain temperature drop. Fig: 3 Fig. 2 represents the temperature distribution in a helically grooved coil in which copper is considered as inner material and outer pipe material as steel in which the inner fluid is taken as steam and the outer fluid is water. The temperature drops from 473K to 317K.The fig represents the contours at static temperature at certain 34

temperature drop. Fig: 4 Fig. 3 represents the temperature distribution in a helically grooved coil in which the inner material of the pipe is taken as aluminium and the outer pipe is steel in which steam is considered as internal fluid and water is considered as external fluid. The temperature drops from 473K to 307K. Fig: 5 Fig4 represents the temperature distribution in a helically grooved coil in which the inner material of the pipe is taken as carbon steel and the outer pipe is steel in which steam is considered as internal fluid and water is considered as external fluid. The temperature drops from 473K to 315K. 35

Fig: 6 Solutions: By the analysis for the helically grooved coil pipe, initial conditions were taken as same. The results were as follows: Temperature: (helically grooved coil pipe) Case 1: (Aluminium)Air as inlet (Steel)Water as outlet Case 2: (Copper) Steam as inlet (Steel)Water as outlet Case 3: (Aluminium) Steam as inlet (Steel)Water as outlet : 473k : 326k : 473k : 317k : 473k : 309k Case 4: Carbon steel as inlet Steel as outlet : 315k : 473k Graph 1 represents the inlet and outlet temperature in which air is passed through inner pipe and water is passed through outer pipe in which the inner temperature is of 473K and outlet is 320K. 36

GRAPH 2 Graph2 represents the inlet and outlet temperature in which vapour is passed through inner pipe and water is passed through outer pipe in which the inner temperature is 473K and outlet is 317K GRAPH 3 37

Graph 3 represents the inlet and outlet temperature in which vapour is passed through inner pipe and water is passed through outer pipe in which the inner temperature is 473K and outlet is 309K. Graph 3 Graph 4 represents the inlet and outlet temperature in which carbon steel is considered as inner pipe material and steel is considered as outer pipe material in which the inner temperature is 473k and the outer temperature is 315k. Graph 4 38

Conclusion: An experimental analysis was carried out in a concentric tube heat exchanger for the study of heat transfer coefficient and temperature distribution. Helically grooved coil of three different inner materials were investigated for parallel flow configuration. From the comparisons with different inlet materials it was found that the helical groove with aluminium as inlet pipe material is highly preferred in order to increase the temperature distribution of a heat exchanger. Future Scope: The analysis of heat exchanger was obtained by considering helical coil as inner pipe and for application purpose it can be used in condensers, refrigeration process and thermal plants. By considering optimal pitch value the heat transfer rate can be increased and also by nano fluids the study of heat transfer rate and temperature distribution can be experimentally obtained. References: 1. A Zachar, Analysis of coiled tube heat exchangers to improve improve heat transfer rate with spirally corrugated wall. 2. P.G.Vicente, A.Viedma, Experimental analysis on heat transfer and frictional characteristics of spirally corrugated tubes in turbulent flow at dissimilar prandtl numbers. 3. W.H.Azmi, K.V. Sharma, Shahrani Anuar, Turblent forced convection heat transfer of nanofluids by twisted tapes introduced in a plain tube. 4. B. Zheng, C.X.Lin, M.A. Ebadian, mutual laminar forced convection and thermal radiation in helical pipe. 5. S Rainieri, F Bozzoli, L Cattani, multiple convective heat transfer improvement in helically coiled wall corrugated tubes. 6. V.Zimparov, Prediction of friction factors and heat transfer coefficients for turbulent flow in corrugated tubes shared with twisted tape inserts. 7. K. Vijay,A K Jilani,Heat transfer analysis through corrugated twisted pipe 8. Amol Andhare, V M Kripalni, J P Modak, Thermal analysis of helical coil in a shell and tube heat exchanger comparing with various numbers. 39