Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger

Similar documents
Design, Fabrication and Testing of helical tube in tube coil heat exachanger

Heat Transfer Enhancement for Double Pipe Heat Exchanger Using Twisted Wire Brush Inserts

International Journal of Scientific & Engineering Research, Volume 6, Issue 10, October ISSN

CFD Investigation of Influence of Tube Bundle Cross-Section over Pressure Drop and Heat Transfer Rate

A Review on Experimental Investigation of U-Tube Heat Exchanger using Plain Tube and Corrugated Tube

CFD analysis of heat transfer enhancement in helical coil heat exchanger by varying helix angle

EXPERIMENTAL INVESTIGATIONS OF DOUBLE PIPE HEAT EXCHANGER WITH TRIANGULAR BAFFLES

ABSTRACT I. INTRODUCTION III. GEOMETRIC MODELING II. LITERATURE REVIW

A REVIEW ON INVESTIGATION OF HELICAL COIL HEAT EXCHANGER

Enhance the Performance of Heat Exchanger with Twisted Tape Insert: A Review

THERMAL ANALYSIS OF HELICALLY GROOVED COIL IN A CONCENTRIC TUBE HEAT EXCHANGER

ENHANCEMENT OF HEAT TRANSFER COEFFICIENT THROUGH HELICAL COIL

Heat Exchangers (Chapter 5)

Optimisation of Double Pipe Helical Tube Heat Exchanger and its Comparison with Straight Double Tube Heat Exchanger

Design and experimental analysis of pipe in pipe heat exchanger

NOVATEUR PUBLICATIONS INTERNATIONAL JOURNAL OF INNOVATIONS IN ENGINEERING RESEARCH AND TECHNOLOGY [IJIERT] VOLUME 1, ISSUE 1 NOV-2014

Analysis of Heat Transfer Enhancement in Tube-in-tube Helical Coil Heat Exchangers

Experimental Study of Heat Transfer Augmentation in Concentric Tube Heat Exchanger with Different Twist Ratio of Perforated Twisted Tape Inserts

Design and Performance Study of Shell and Tube Heat Exchanger with Single Segmental Baffle Having Perpendicular & Parallel-Cut Orientation.

Visualization of Flow and Heat Transfer in Tube with Twisted Tape Consisting of Alternate Axis

Experimental investigation of shell-and-tube heat exchanger with different type of baffles

Comparative Numerical Analysis of Straight and Conical Coil Heat Exchanger

International Journal of Advance Engineering and Research Development

CFD analysis of triple concentric tube heat exchanger

EXPERIMENTAL ANALYSIS AND PERFORMANCE CHARACTERISTIC OF HEAT TRANSFER IN SHELL AND TWISTED TUBE HEAT EXCHANGER

COMPUTATIONAL ANALYSIS TO MAXIMIZE THE HEAT TRANSFER RATE OF DOUBLE TUBE HELICAL COIL HEAT EXCHANGER

Simulation Studies on the Effect of Porous Twisted Plate Inserts on the Performance of Fire Tube Steam Packaged Boiler

Performance Evaluation Of A Helical Baffle Heat Exchanger

Heat Transfer in Rectangular Duct with Inserts of Triangular Duct Plate Fin Array

ENHANCEMENT OF HEAT TRANSFER RATE AND REDUCTION OF SHELL SIDE PRESSURE DROP IN HELIX HEAT EXCHANGER WITH CONTINUOUS HELICAL BAFFLES

CONJUGATE HEAT TRANSFER ANALYSIS OF HELICAL COIL HEAT EXCHANGE USING CFD

SINGLE-PHASE CONVECTIVE HEAT TRANSFER AND PRESSURE DROP COEFFICIENTS IN CONCENTRIC ANNULI

Analysis to Determine Heat Transfer Using Twisted Tape Inserts In a Horizontal Tube

Experimental Analysis and Performance Characteristic Of Heat Transfer In Shell and Twisted Tube Heat Exchanger.

Research Article Thermohydraulic Analysis of Shell-and-Tube Heat Exchanger with Segmental Baffles

CFD Integrated Optimum Design and Prototyping of Shell and Tube Heat Exchanger

Design and Performance Analysis of Louvered Fin Automotive Radiator using CAE Tools

Investigation of Comparison of Three Different Tube Bundles of Heat Exchanger

An Approach for Enhancement of Heat Transfer Using Conical Convergent Ring Inserts In Tube

An Experimental Study of Thermo-Hydraulic Performance of Modified Double Pipe Heat Exchanger Using Mesh Inserts

ADVANCES in NATURAL and APPLIED SCIENCES

Design and Fabrication of Shell and Tube Type Heat Exchanger and Performance Analysis

CFD ANALYSIS ON LOUVERED FIN

THERMAL ANALYSIS OF SHELL AND TUBE HEAT EXCHANGER

TEMPERATURE APPROACH OPTIMIZATION IN THE DOUBLE PIPE HEAT EXCHANGER WITH GROOVE

Experimental Investigation of Heat Transfer characteristics Enhancement through Grooved Tube

Enhanced Heat Transfer Surface Development for Exterior Tube Surfaces

Comparison of Heat transfer Enhancement in Tube in Tube heat exchanger using Different Turbulent Generator.

IJESR/Oct 2012/ Volume-2/Issue-10/Article No-12/ ISSN International Journal of Engineering & Science Research

Experimental Study on Heat Enhancement of Helixchanger with Grooved Tubes

Experimental Investigation on Turbulent Flow Heat Transfer in a Horizontal Circular Pipe using Coil and Twisted Tape Inserts

Efficiency Improvement in Shell and Tube Heat Exchanger Using CFD Tool

Design of Shell and Tube Type Heat Exchanger using CFD Tools

FLOW AND HEAT TRANSFER ENHANCEMENT AROUND STAGGERED TUBES USING RECTANGULAR VORTEX GENERATORS

HEAT TRANSFER ENHANCEMENT BY USING TWISTED TAPE INSERTS WITH CIRCULAR HOLES IN FORCED CONVECTION

CFD Analysis of Double Pipe Heat Exchanger with Twisted Tape Insert in Inner Pipe

CFD ANALYSIS OF DOUBLE HELICAL PIPE PARALLEL& COUNTER FLOW HEAT EXCHANGER

NUMERICAL INVESTIGATION OF PISTON COOLING USING SINGLE CIRCULAR OIL JET IMPINGEMENT

Heat Transfer Enhancement In Pipe With Passive Enhancement Technique

Prediction of Thermal Deflection at Spindle Nose-tool Holder Interface in HSM

Exhaust Gas Waste Heat Recovery and Utilization System in IC Engine

SOLAR FLAT PLATE COLLECTOR HEAT TRANSFER ANALYSIS IN THE RAISER WITH HELICAL FINS Mohammed Mohsin Shkhair* 1, Dr.

GEOMETRICAL PARAMETERS BASED OPTIMIZATION OF HEAT TRANSFER RATE IN DOUBLE PIPE HEAT EXCHANGER USING TAGUCHI METHOD D.

Department of Mechanical Engineering, D Y Patil College of Engineering, Akurdi, Pune , Savitribai Phule Pune University, India

NUMERICAL SIMULATION OF HELICAL COIL TUBE IN TUBE HEAT EXCHANGER WITH BAFFLES

International Journal of Advance Engineering and Research Development

Effect of Nanofluid on Friction Factor of Pipe and Pipe Fittings: Part I - Effect of Aluminum Oxide Nanofluid

EFFECT OF EXTERNAL THREADED INSIDE TUBE ON HEAT TRANSFER RATE IN A CONCENTRIC TUBE HEAT EXCHANGER: A CRITICAL REVIEW

Thermal Analysis of Shell and Tube Heat Exchanger Using Different Fin Cross Section

Parametric Study on Flow and Heat Transfer Performance of Multi-Flow Spiral-Wound Heat Exchanger

ENHANCEMENT OF HEAT TRANSFER IN SHELL AND TUBE HEAT EXCHANGER WITH TABULATOR AND NANOFLUID

INTERNATIONAL JOURNAL OF MECHANICAL ENGINEERING AND TECHNOLOGY (IJMET)

Experimental Study of Heat Transfer Enhancement in Tube in Tube Heat Exchanger using Rectangular Wing Type Vortex Generator

Comparison of Swirl, Turbulence Generating Devices in Compression ignition Engine

REVIEW PAPER ON INVESTIGATION OF PERFOMANCE FOR SHELL AND TUBE HEAT EXCHANGER

Influence of Pressure Drop, Reynolds Number and Temperature in the Design of Double Pipe Heat Exchanger on Hot Fluid Side in Inner Pipe

Heat transfer enhancement of a single row of tube

Computational Investigation of Normal and Hybrid Cooling Fins of Internal Combustion Engine

Numerical and Experimental Investigations of Heat Transfer in Double Pipe Heat Exchangers with Inner and Annular Twisted Tape

Modeling and Fluid Flow Analysis of Wavy Fin Based Automotive Radiator

FLOW CONTROL THROUGH VORTEX SHEDDING INTERACTION OF ONE CYLINDER DOWNSTREAM OF ANOTHER. Jonathan Payton 1, and *Sam M Dakka 2

PERFORMANCE ANALYSIS OF DIFFERENT HEAT EXCHANGER DESIGN USING CFD SIMULATION 1 KVENUMADHAV 2 SUDHANSHU KUMAR

INVESTIGATION OF HEAT TRANSFER CHARACTERISTICS OF CIRCULAR AND DIAMOND PILLARED VANE DISC BRAKE ROTOR USING CFD

HEAT TRANSFER ENHANCEMENT BY V-NOZZLE TURBULATORS

The Practical Uses of Computational Fluid Dynamics Not Just a Pretty Picture

TO STUDY OF PARAMETRIC ANALYSIS OF SHELL AND TUBE HEAT EXCHENGER

Thermal Stress Analysis of Diesel Engine Piston

Experimental Analysis of Heat Transfer and Friction Factor Characteristics in Turbulent Flow through a Tube Fitted with Screw Tape

Single-phase Coolant Flow and Heat Transfer

Thermal Analysis of Helical and Spiral Gear Train

CFD Analysis and Comparison of Fluid Flow Through A Single Hole And Multi Hole Orifice Plate

Investigation for Flow of Cooling Air through the Ventilated Disc Brake Rotor using CFD

Manufacturing and Comparative Analysis of Threaded Tube Heat Exchanger with Straight Tube Heat Exchanger

DESIGN OPTIMIZATION OF SHELL AND TUBE HEAT EXCHANGER FOR OIL COOLER BY COMSOL MULTIPHYSIS

Analysis of Air Flow and Heat Transfer in Ventilated Disc Brake Rotor with Diamond Pillars

An Experimental Investigation for the Rate of Heat Transfer in Double Pipe Heat Exchanger with Fins on Inside Surface of Internal Tube

An Overview of Shell & Tube Type Heat Exchanger Design by Kern s Method

Design Optimization of Cross Flow Heat Exchanger

ADVANCES in NATURAL and APPLIED SCIENCES

International Journal of World Research, Vol: I Issue XXXVII, January 2017 Print ISSN: X

Transcription:

Review on Comparative Study between Straight Tube Heat Exchanger and Helical Coil Heat Exchanger Vaibhav M. Samant 1, Jayesh V. Bute 2 1 (Student (Mechanical Engineering)/Pimpri Chinchwad College Of Engineering &Research, Pune, India) 2 (Asst. Prof./Pimpri Chinchwad College Of Engineering &Research, Pune, India) Abstract: The main purpose of this study is to determine the relative advantage of using a helically coiled heat exchanger over a straight tube heat exchanger. It is found that the heat transfer in helical circular tubes is higher as compared to Straight tube due to their geometrical shape. Helical coils offer advantages over straight tubes due to their compactness and increased heat transfer coefficient. The increased heat transfer coefficients are a consequence of the curvature of the coil, which induces centrifugal forces to act on the moving fluid, resulting in the development of secondary flow. The curvature of the coil governs the centrifugal force while the pitch (or helix angle) influences the torsion to which the fluid is subjected to. The difference in velocity sets-in secondary flows. The fluid particles flowing at the core of the pipe have higher velocities than those flowing near to the pipe wall. Thus the fluid particles flowing close to the tube wall experience a lower centrifugal force than the fluid particles flowing in the tube core. This causes the fluid from the core region to be pushed towards the outer wall. This additional convective transport increases heat transfer and the pressure drop when compared to that in a straight tube. Keywords: Helical coil heat exchanger, heat transfer, secondary flow, straight tube heat exchanger, I. INTRODUCTION Several techniques are being used to increase the thermal performance of the heat exchanger. Active techniques, passive techniques and compound techniques are used for enhancing the heat transfer. The active techniques require external forces like fluid vibration. The passive techniques require special surface geometries. The compound technique is the combination of any two or more methods of used for improving the performance of heat exchanger. Helical coiled tubes are superior to straight tube due to their compactness and increased heat transfer coefficients. Flow in curved tube is different from the flow in straight tube because of the presence of the centrifugal forces. It induces the secondary flow in liquid. The intensity of secondary flow developed in the tube is the function of tube diameter (d) and coil diameter (D). Due to enhanced heat transfer in helical coiled configuration the study of flow and heat transfer characteristics in the curved tube is of prime importance. The secondary fluid flow of helical tubes was first studied by Dean with toroidal system. Based on the perturbation method, Germano solved the fluid flow equations of a helical duct with elliptical cross section. This secondary flow pattern generally consists of two vortices, which move fluid from the inner wall of the tube across the center of the tube to the outer wall. Upon reaching the outer wall it travels back to the inner wall. The secondary flow increases heat transfer rates as it moves fluid across the temperature gradient. Thus, there is an additional convective heat transfer mechanism, perpendicular to the axial flow, which does not exist in straight tube heat exchangers The amount of heat transferred depends upon various factors like type of fluid flow, area of heat transfer, thermal conductivity of the separating wall etc. There are three primary classifications of heat exchangers according to their flow arrangement. Parallel flow heat exchangers, Counter-flow heat exchangers, Cross-current or cross-flow heat exchangers. Helical coil heat exchangers are of great use in industrial applications such as power generation, nuclear industry, process plants, heat recovery systems, refrigeration, food industry, etc due to its compact structure and high heat transfer coefficient. They are widely used in chemical and petrochemical plants, refineries and sewage treatment. II. LITERATURE REVIEW The following research papers are studied in detail and the abstract of the work is presented here: The intensity of secondary flow developed in the tube is the function of tube diameter (d) and coil diameter (D) as presented by Dravid et al [1]. Due to enhanced heat transfer in helical coiled configuration the study of flow and heat transfer characteristics in the curved tube is of prime importance. Developing fluid-to-fluid helical heat exchangers (fluid is present on both sides of the tube 498

wall) requires a firm understanding of the heat transfer mechanism on both sides of the tube wall. Though much investigation has been performed on heat transfer coefficients inside coiled tubes, little work has been reported on the outside heat transfer coefficients. The result shows that the increasing of the coiled tube pitch decreases the inside Nusselt Number. He also studied that helical coil have compact size and higher heat transfer coefficient they are widely used in industrial applications such as food preservation, refrigeration, process plant, power generation etc. Timothy J. Rennie, Vijaya G.S. Raghavan [2]Have done An experimental study of a double-pipe helical heat exchanger. Two heat exchanger sizes and both parallel flow and counter flow configurations were tested. Flow rates in the inner tube and in the annulus were varied and temperature data recorded. An attempt has been made to study the parallel flow and counter flow of inner higher temperature fluid flow and lower temperature fluid flow, which are separated by copper surface in a helical coil heat exchanger. Helical geometry allows the effective handling at higher temperatures and extreme temperature differentials without any highly induced stress or expansion of joints. This type of heat exchanger consists of series of stacked helical coiled tubes and the tube ends are connected by manifolds, which also acts as fluid entry and exit locations. In this paper, we focus on design parameters and heat transfer conditions of a vaporizer or generator of a simple vapor absorption refrigeration system having flow condition of refrigerant taken as laminar flow, The research was done by Kondhalkar and Kapatkat [3] on performance analysis of spiral tube heat exchanger used in oil extraction system. They discussed about the effective use of spiral tube heat exchanger in oil extraction process. They carried out research on the performance analysis of spiral tube heat exchanger over the shell and tube type heat exchanger. They studied the Performance of spiral tube heat exchanger and shell and tube heat exchanger for sugandhmantri oil emulsion. They found that the relation between mass flow rate and effectiveness and found out that for the same mass flow rate effectiveness increases for the spiral tube heat exchanger. Also it was observed that the heat transfer coefficient increased with increase in Reynolds number. Also they investigated the relation between Reynolds numbers and Nusselt number and concluded that Nusselt number increases with increase in Reynolds number.. Zhengguo Zhang [4] et al.were made attempts to investigate the heat transfer characteristics of a helically baffled heat exchanger combined with one three-dimensional finned tube. For the counter mode operation, experiments were carried out and overall heat transfer coefficient determined using modified Wilson plot. The agreement with the numerical and experimental predictions of Nusselt number and pressure drop values were well within 6.3% for Nusselt number and 9.8% for pressure drop in the shell side respectively. Shinde D. &Dange M.[5] experimental investigation of heat transfer in cone shaped helical coil heat exchanger is reported for various Reynolds number. The purpose of this article is to compare the heat transfer in cone shaped helical coil and simple helical coil. The pitch, height and length of both the coils are kept same for comparative analysis. The calculations have been performed for the steady state condition and experiments were conducted for different flow rates in laminar and turbulent flow regime. The coil side flow rate is kept varying while the coil side flow rate is kept constant. It was observed that the effectiveness of the heat exchanger for the cone shaped helical coil is more than that for the simple helical coil. Results show that the heat transfer rates for the cone shaped helical coil are comparatively higher than that of the simple helical coil. It was found that the heat transfer rates are 1.18 to 1.38 times more for the cone shaped helical coil than that of simple helical coil. Bibin Prasad et al. [6] helical pipes are universally used for heat transfer enhancement in heat exchangers. In the present work, CFD simulations are carried out for a counter flow double pipe helical heat exchanger byvarying the flow rates of a single fluid (water). The heat transfer characteristics of the same are compared withthat of a counter flow double pipe straight tube heat exchanger for the same flow rates. The results were interpreted by developing correlations between Nusselt number and Dean Number for both the inner and outer helical pipes which shows a strong linear relationship. A. Parameters to be taken into consideration for calculation of performance assessment of heat exchanger: 1) For the turbulent flow region (Re 10 4 ), Nu = Re 0.8 Pr 1/3 (μ/μ w ) 0.14 Where, Nu = Nusselt Number = hd/k D 0,Di =Outside and Inside diameter of the pipe Re = Reynold s Number = DVρ/μ V = average fluid velocity. Pr = Prandtl Number = cpμ/k Cp,μ,ρ,k = Fluid properties at avg. bulk temperature. 499

It is observed that Nuincreases with increase in Re. This shows that the secondary s developed in the fluid flow goes on increasing, as Re increases, which increases the turbulence in the fluid flow. The increase in turbulence allows proper mixing of the fluid, which enhances the Nu. And all the remaining parameters indirectly depend on Reynold s number and Nusselt number. 2) Overall heat transfer coefficient: (U) U= Q/A 0 ΔT A 0 =π D 0 L 3) The fouling factor for the exchanger is given as: R D = R Di (Do/Di)+ R Do Fouling could considerably impact on the thermal and mechanical performance of heat exchangers. It also impedes fluid flow, accelerates corrosion and will increase pressure drop across heat exchangers. Helical geometry provides low fouling characteristics which increases the schedule cleaning period of tube bundle. 4) Capacity Ratio 5) Number Of Transfer Units(NTU): It is a dimensionless quantity and it is an indicator of size of heat transferring areas of heat exchanger. Large value of NTU means large heat transferring area. 6) LMTD-Log mean temperature difference: LMTD= (dt A dt B )/ln(dt A /dt B ) dt A = T hot in T cold out dt B =T hot out T cold in For constant heat and mass transfer, LMTD shell and tube >LMTD counterflow > LMTD cross flow >LMTD parallel flow 7) Friction factor f = 64/R e...(for laminar flow) f= 0.4137 R -0.2385 e...(for turbulent flow) This friction factor, f is a dimensionless factor that depends mainly on velocity v, diameter D, density and viscosity. 8) Effectiveness = Q/Q max Q = Actual heat transfer rate Q max =Maximum possible heat transfer rate B. Straight Tube Heat Exchanger Fig 1.1 Simple shell and straight tube heat exchanger 500

International Journal for Research in Applied Science & Engineering Technology (IJRASET) Shell-and-tube exchangers are classified and constructed in accordance with the widely used TEMA (Tubular Exchanger Manufacturers Association). When the medium containing heat is a liquid or a vapour which heats another liquid, then the shell and tube heat exchanger must be used since both paths must be sealed to contain the pressures of their respective fluid. The shell contains the tube bundle, and usually internal baffles, to direct the fluid in the shell over the tubes in multiple passes. The shell is inherently weaker than the tubes so that the higher-pressure fluid is circulated in the tubes while the lower pressure fluid flows through the shell. Tube and shell heat exchangers are available in a wide range of standard sizes with many combinations of materials for the tubes and shells. Heat transfer in straight tubes is governed by Reynolds and Prandtl Numbers, under both laminar and turbulent flow conditions, and is usually presented in a form such as: Nnu= c N ReaN prb...(1) Where, NNu is the Nusselt number, with the a, b, and c being constants, Re is the Reynolds number, pr is prandtl number. Heat transfer rate of shell and tube heat exchanger depends on some of following parameters such as length of tube, number of baffles, baffle cut. Generally the shell and heat type heat exchanger are widely used for various purposes having limitation to be designed for maximum up to 15000 psi and 1000 0F. There are few disadvantages concerned with shell and tube heat exchangers are: 1)Fixed tube sheet type exchanger having cleaning issues as well as can be used for low temperature difference as there is no provision for the thermal expansion of the same. 2)Shell and tube heat exchanger are Subject to flow induced vibration which can lead to equipment failure. Subject to flow maldistribution especially with two phase inlet streams. They can be designed for special operating conditions: vibration, heavy fouling, highly viscous fluids, erosion, corrosion. C. Helical Coil Heat Exchanger Fig. 2.1 helical coil heat exchanger Fig. 2.2 Cut section of helical coil Helically coiled exchangers have compact size provides a distinct benefit. Helical geometry permits handling of high temperatures and extreme temperature differentials without high induced stresses or costly expansion joints. High-pressure capability and the ability to fully clean the service fluid flow area add to the exchanger s advantages, Although various configurations of coil are available. A typical shell and coiled tube heat exchanger is shown in Fig.2.1. In coiled tubes, the heat transfer coefficients are higher due to the presence of secondary flow, which increases the extent of mixing. The difference between the heat transfer coefficient (h) in coiled tubes and straight tubes is significant. NNuc = NNus [1+ 3.5 (r / R)]... (2) Heat transfer rate of helical coil heat exchanger depends on some of following parameters such as coil pitch, Pitch circle diameter, pipe diameter. D. Comparison Between Straight Tube Heat Exchanger And Helical Coil Heat Exchanger Variation of overall heat transfer coefficient for straight tube parallel flow, straight tube counter flow, helical coil parallel flow and helical coil counter flow, when hot water mass flow rate is constant and cold water mass flow rate varied. As the mass flow rate through the shell increases the overall heat transfer coefficient increases, and it is observed that hot mass flow rate inside tube 501

increases the overall heat transfer coefficient also increases. Overall heat transfer coefficient of counter flow heat exchanger is high compared to corresponding exchanger parallel flow. Helical coil counter flow has max. Overall heat transfer coefficient and straight tube parallel flow has lowest overall heat transfer coefficient. Fig. variation of overall heat transfer coefficient when mass flow rate inside the tube is 30 LPH Overall heat transfer coefficient (U) in the helical heat exchanger is much higher than that in straight tubular heat exchangers. For all values of Reynolds numbers, the overall heat transfer coefficient in the helical coils was larger than that in the straight tubes. The overall heat transfer coefficient (U) in the helical heat exchanger increased with flow rate and approached a maximum value at higher flow rates. III. CONCLUSION From study it is clear that, Helical coil counter flow is most effective in all these conditions and straight tube parallel flow heat exchanger is least effective. There is some gap between results we are getting from current heat exchangers and results we should get. This gap can be bridged by making use of helical coil heat exchangers with some design modifications for betterment of the results. Overall heat transfer coefficient increases with increase in hot water mass flow rate and cold water mass flow rate. The torsional forces induced by the pitch causes oscillations in the Nusselt number. However, the average Nusselt number is not affected by the coil pitch. Unlike the flow through a straight pipe, the centrifugal force caused due to the curvature of the pipe causes heavier fluid (water-phase) to flow along the outer side of the pipe. High velocity and high temperature are also observed along the outer side.as the pitch is increased, higher velocity and higher temperature regions are on the bottom half of the pipe. Increase in pipe diameter, keeping the inlet velocity constant, causes higher heat transfer coefficient and lower pressure drop. This effect is due to the influence of secondary flows. By making use of helical geometry the centrifugal force and shear stress can be increased to reduce the fouling effect. For a particular mass flow rate, helical tube heat exchanger provides an increase in heat transfer coefficient by 10%. Heat exchangers used now a days have certain disadvantages such as less effectiveness, less heat transfer coefficient. These demerits can be over comed by using multi pass helical coil heat exchangers. 502

REFERENCES [1] Dravid, A. N., Smith., K. A., Merrill, E.A., and Brian, P.L.T., (1971).Effect of secondary fluid motion on laminar flow heat transfer in helically coiled tubes AICHE Journal, Vol.17(5):1114-1122. [2] Timothy J. Rennie, Vijaya G.S. Raghavan, 2005 Experimental studies of a double-pipe helical heat exchanger [3] Kondhalkar G. E, Kapatkat V. N, Performance Analysis of Spiral Tube Heat Exchanger used in oil extraction system International Journa,l of Modern Engineering Research (IJMER), Vol.2, Issue.3, May-June 2012, PP-930-936. [4] Zhengguo Zhang, Dabin Ma, Xiaoming Fang, XuenongGao, Experimental and Numerical Heat Transfer in a Helically Baffled Heat Exchanger Combined with One Three-Dimensional Finned Tube, Chemical Engineering and Processing, Vol. 47, pp 1738 1743, 2008. [5] Shinde D. &Dange M, 2013, Heat Transfer Analysis of a Cone Shaped Helical Coil Heat Exchangerǁ, International Journal of Innovations in Engineering and Technology,Vol. 3 Issue 1, p. no. 56-62. [6] Bibin Prasad, Sujith V, Mohammed Shaban K, SajuHaneef, Sandeep N, Vishnu Raj, 2013, Comparison of Heat Transfer between a Helical and Straight Tube Heat Exchangerǁ, International Journal of Engineering Research and Technology, Vol. 6, Number 1, pp. 33-40. [7] SurendraVishvakarma, Sanjay Kumbhare, K. K. Thakur. A Review On Heat Transfer Through Helical Coil Heat Exchangers. International Journal Of Engineering Sciences & Research Technology ISSN: 2277-9655 [8] N. D. Shirgire1, P. Vishwanath Kumar, Review on Comparative Study between HelicalCoil and Straight Tube Heat Exchanger, IOSR Journal of Mechanical and Civil Engineering, 2013. [9] Salimpour, Heat transfer Coefficients of shell and coiled tube heat exchangers,experimental Thermal and Fluid science 2009 [10] Sreejith K., T.R. Sreesastha Ram, Jaivin A. Varghese Experimental Investigation of a Helical Coil Heat Exchanger [11] 503