DC Master 24/ A

Similar documents
IVET-D 16A / 3,5 kva IVET-D 30A / 7,5 kva IVET-D 16A / 3,5 kva - MT

EASY CHARGE Waterproof portable Battery Charger

Mass Sine 24/10000 Mass Sine 24/15000

EASY CHARGE Weather-resistant fixed mount Battery Charger

GEBRUIKERSHANDLEIDING / USERS MANUAL BETRIEBSANLEITUNG / MODE D EMPLOI ALPHA PRO

Sinewave Inverters. SWING 150VA and 300VA. User s manual

AUTO CHARGE 11 MODEL #: XX. AUTOMATIC BATTERY CHARGER U.L. Configuration INSTRUCTION MANUAL

AUTO CHARGE 12 AUTOMATIC BATTERY CHARGER

MASTERsine Inverter PXA Series Installation Guide

c-go 24V/6A 24V/8A 24V/12A

ChargeMaster 12/25-3, 24/12-3

Battery Charger. Series EASY Charger. User s manual

Li-ion Battery. MLi Ultra 12/2500 MLi Ultra 12/5000 MLi Ultra 24/5000 INSTALLATION AND COMMISSIONING OF MULTIPLE BATTERIES

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

Battery Charger Series EASY Charger

USER MANUAL OUTBOARD MOTOR AC

CHARGEMASTER 1 12/35-3, 12/50-3, 24/20-3, 24/30-3

BATTERY CHARGER CHR-1445

Sinewave Inverters. SWING pro 200VA and 350VA. User s manual

SOLAR CHARGE CONTROLLER

OPERATOR'S MANUAL IMPORTANT SAFETY INSTRUCTIONS

Mass Charger MASS 12/60-2 MB; 12/80-2 MB; 24/50-2 MB; 24/75 MB; 24/100 MB; 3-24/100 MB; 48/25 MB; 48/50 MB

MASS COMBI 12/ (120V), 12/ (120V), 24/ (120V), 24/ (120V)

Multi-Mover Charger for model L25

Mass Charger MASS 24/15-2 MB; 24/25-2 MB; 24/25-2 DNV MB

Sentry Battery Charger. Installation and Operations Manual Section 75

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

S150,S300 Series Pure Sine Wave Inverter User s Manual

Installation and operating instructions. Solar charge controller 10 A / 15 A / 0 A / 30 A PHOTOVOLTAIK - PHOTOVOLTAICS - PHOTOVOLTAIQUE - FOTOVOLTAICA

SP6. Automatic Battery Charger. Model

USER MANUAL GEBRUIKSAANWIJZING. Phoenix 12/150 Phoenix 24/150 Phoenix 48/150

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

Power Inverter 400 MW Owner s Manual

Sinewave Inverters. Jazz 700VA and 1000VA. User s manual

Cruising Charger Series OWNER S MANUAL

PureSine 150/300 Pure Sine Wave Inverter User s Manual

ELECTRONIC MARINE CONVERTER/CHARGER Owners Manual Models PD2020, PD2030, PD2040, PD2050, PD2060, PD2080

3000W POWER INVERTER. User Manual

Go Power! Manual. GP-Smart Charger

10 AMP ON BOARD BATTERY CHARGER

12V 1 AMP (1000 ma) Automatic Battery Charger & Maintainer

Models: SP3, SPSS3 Automatic Battery Charger

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

Armon Edero. User manual

ILED Dorado. User Manual

MODEL 6010A 6 12 VOLT BATTERY CHARGER ASSOCIATE

AUTO CHARGE D PUMP PLUS

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

AUTO CHARGE D2 MODEL #: AUTOMATIC TRIPLE OUTPUT BATTERY CHARGER INSTRUCTION MANUAL

USER MANUAL Please read and understand this user manual carefully before each use. Model: X-10

Intelligent Charging System Series

ACCUSENSE CHARGE SERIES ON/OFF BOARD FULLY AUTOMATIC BATTERY CHARGER

IMPORTANT SAFETY INSTRUCTIONS IMPORTANT: READ AND SAVE THIS SAFETY AND INSTRUCTION MANUAL. KEEP IT WITH OR NEAR CHARGER AT ALL TIMES.

Lithium-ion Battery MLI-E 12/1200 USERS MANUAL

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

Model: SE-4020-CA Automatic Battery Charger

User s Manual. Automatic Switch-Mode Battery Charger

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

8 Step Fully Automatic Intelligent BATTERY CHARGER 12V 5A USER S MANUAL. Charges & Maintains. Flooded (WET), MF, VRLA, AGM, GEL & Calcium batteries

AUTO CHARGE 4000 MODEL #: AUTOMATIC DUAL OUTPUT BATTERY CHARGER INSTRUCTION MANUAL. Ph: Fax:

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

SOLAR CHARGE CONTROLLER N 2010 IN 2011/ N 2012/ N 2014

A48 / A48B (base plate) BATTERY CHARGER

DriveMaster 2.5 & 3.6

OWNER S MANUAL. Model YUA2AMPCH 2 AMP Dual-Bank Automatic Battery Charger & Maintainer READ ENTIRE MANUAL BEFORE USING THIS PRODUCT

MODEL A97 SERIES. Switchmode Utility Rectifier/Battery Charger ECN/DATE

Solar ChargeMaster 60 MPPT-MB

Maintenance Manual 13 AMPERE POWER SUPPLY 19A704647P1-P3. Mobile Communications LBI-31801C

ALPHA ALTERNATOR 12/90, 12/130, 24/75, 24/110 & 24/150

MODEL 2602A-12 3 STAGE AUTOMATIC BATTERY CHARGER OWNER S MANUAL SAVE THESE INSTRUCTIONS

GSL Electronics Modified Sine Wave Power Inverters

Operating Instructions

USERS MANUAL / GEBRUIKERSHANDLEIDING BETRIEBSANLEITUNG / MANUEL D UTILISATION MANUAL DE UTILIZACION / INSTRUZIONI PER L USO.

10AMP FULLY AUTOMATIC 6V & 12V BATTERY CHARGER OWNER'S MANUAL

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

Design Features: User Manual. 1. PFC function. 2. LCD remote control. 3. Battery temperature sensor function.

MASS COMBI 12/ (120V & 230V), 12/ (120V & 230V), 24/ (120V & 230V), 24/ (120V), 24/ (230V)

CHARGEMASTER 12/35-3, 12/50-3, 24/20-3, 24/30-3

Guardian Battery Charger Series. Installation and Operations Manual Section 75

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

12 VOLT 30 AMP DIGITAL SOLAR CHARGE CONTROLLER

KeContact P20. User manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

A39 UNIVERSAL SCR CHARGER

Table of Contents 文管中心 發行章

innovations in battery charging

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

CHARGEMASTER 12/25-3, 24/12-3

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS Ext. 322

801 BUSINESS CENTER DRIVE MOUNT PROSPECT, ILLINOIS

CPS Energy Balancer. Version: 1.0

INTELLIGENT BATTERY CHARGER/MAINTAINER

Operating instructions 1 4 Mode d emploi 5 8 Instrucciones de uso 9 13 Manual de instruções 15 18

30,000mWh LITHIUM-POLYMER CAR JUMP STARTER USER S MANUAL PLEASE READ THIS MANUAL CAREFULLY BEFORE OPERATION

USERS MANUAL / GEBRUIKERSHANDLEIDING BETRIEBSANLEITUNG / MANUEL D UTILISATION MANUAL DE UTILIZACION / INSTRUZIONI PER L USO.

Sinewave Inverter. HIPHOP pro 1500 HIPHOP pro User s manual

Mod: KLD6-12/35XLAS-N

OPERATOR S MANUAL JUMP STARTER. and DC Power Source. Model No CAUTION: Sears, Roebuck and Co., Hoffman Estates, IL U.S.A.

CHARGEMASTER PLUS 12/75-3, 12/100-3, 24/40-3, 24/60-3

Transcription:

USERS MANUAL DC Master 24/12 50-60A DC-DC converter MASTERVOLT Snijdersbergweg 93, 1105 AN Amsterdam The Netherlands Tel.: +31-20-3422100 Fax.: +31-20-6971006 www.mastervolt.com ENGLISH Copyright 2015 Mastervolt, 10000008899/01 - February 2015

TABLE OF CONTENTS TABLE OF CONTENTS: 10000008899/01 - February 2015 1 GENERAL INFORMATION... 3 1.1 Use of this manual... 3 1.2 Product description and application... 3 1.3 Use of pictograms... 3 1.4 Identification label... 3 1.5 Liability... 3 2 IMPORTANT SAFETY INSTRUCTIONS... 4 2.1 General... 4 2.2 Explosive gases... 4 2.3 Warning regarding life support applications... 4 2.4 Guarantee specifications... 4 3 INSTALLATION... 5 3.1 Before you start... 5 3.2 Choosing a location to install... 5 3.3 Contents of the delivery:... 5 3.4 Installation step-by-step... 5 4 OPERATION... 6 4.1 Switching on and off... 6 4.2 Remote switch function... 6 4.3 Status LED... 6 4.4 Maintenance... 6 5 TROUBLE SHOOTING... 6 6 TECHNICAL DATA... 7 6.1 Specifications... 7 6.2 Dimensions... 7 7 EC DECLARATION OF CONFORMITY... 8 2 February 2015 / DC Master 24/12 50A / EN

GENERAL INFORMATION 1 GENERAL INFORMATION 1.1 USE OF THIS MANUAL Copyright 2015 Mastervolt. All rights reserved. Reproduction, transfer, distribution or storage of part or all of the contents in this document in any form without the prior written permission of Mastervolt is prohibited. All of the specifications, provisions and instructions contained in this manual apply solely to standard versions of the DC Master 24/12 50 delivered by Mastervolt. This manual is only valid for the following model: 1.4 IDENTIFICATION LABEL P/N: 81400352 Type: DC Master 24/12 50A Input: 17...32V Output: 13.6V 50A nominal 60A Max Part number Description 81400352 DC Master 24/12 50 Keep this manual at a secure place! P/N: 81400352 Type: DC Master 24/12 50A Input: 17...32V Output: 13.6V 50A nominal 60A Max Serial No. F103A0001 Serial No. F103A0001 F103A0001 Apparatus version 1.2 PRODUCT DESCRIPTION AND APPLICATION This Mastervolt DC Master converts a 24V DC voltage to a 12 V DC voltage. Typical application is a 24V battery bank that powers 12V equipment. 1.3 USE OF PICTOGRAMS Safety instructions and warnings are marked in this manual by the following pictograms: WARNING A WARNING refers to possible injury to the user or significant material damage to the converter if the user does not (carefully) follow the procedures. CAUTION! Special data, restrictions and rules with regard to preventing damage. Figure 1: Position of the identification label The identification label is located at the rear side of the DC Master (see Figure 1) Important technical information required for service, maintenance & secondary delivery of parts can be derived from the identification label. 1.5 LIABILITY CAUTION! Never remove the identification label. Mastervolt can accept no liability for: consequential damage due to use of the DC Master; possible errors in the manuals and the results thereof. A procedure, circumstance, etc which deserves extra attention. EN / DC Master 24/12 50A / February 2015 3

IMPORTANT SAFETY INSTRUCTIONS 2 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS 2.1 GENERAL WARNING This chapter describes important safety and operating instructions for use of a DC Master in residential, recreational vehicle (RV) and marine applications. 1 Before using the DC Master, read all instructions and cautionary markings on the DC Master, the batteries, and all appropriate sections of the manual. 2 To reduce the risk of electric shock Do not expose DC Master to rain, snow, spray, moisture, excessive pollution and condensing circumstances. To reduce risk of fire hazard, do not cover or obstruct the ventilation openings. Do not install the DC Master in a non-ventilated room, overheating may result. 3 Use of an attachment or spare part not recommended or sold by Mastervolt may result in a risk of fire, electric shock, or injury to persons. 4 Do not operate DC Master if it has received a sharp blow, been dropped, or otherwise damaged in any way; take it to a qualified serviceman. 5 To reduce risk of electric shock, disconnect the DC Master from both input and output before attempting any maintenance or cleaning. Turning off controls will not reduce this risk. 6 Short circuiting or reversing polarity will lead to serious damage to batteries, DC Master, wiring as well as accessories. Fuses can not prevent damage caused by reversed polarity and the warranty will be void. 7 In case of fire, you must use the fire extinguisher which is appropriate for electrical equipment. 8 If applied in a marine application in the United States, external connections to the DC Master shall comply with the United States Coast Guard Electrical Regulations (33CFR183, Sub part I). 2.2 EXPLOSIVE GASES 1 WARNING RISK OF EXPLOSIVE GASES. WORKING IN VICINITY OF A LEAD-ACID BATTERY IS DANGEROUS. BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION. FOR THIS REASON, IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE USING THE DC MASTER, YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY. 2 To reduce risk of battery explosion, follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of the battery. Review cautionary marking on these products. 3 DANGER: To reduce the risk of explosion Never use the DC Master in situations where there is danger of gas or dust explosion or area in which ignitionprotected equipment is required. 2.3 WARNING REGARDING LIFE SUPPORT APPLICATIONS The DC Master is not sold for applications in any medical equipment intended for use as a component of any life support system unless a specific written agreement pertaining to such intended use is executed between the manufacturer and Mastervolt. Such agreement will require the equipment manufacturer either to contract additional reliability testing of the DC Master and/or to commit to undertake such testing as a part of the manufacturing process. In addition the manufacturer must agree to indemnify and not hold Mastervolt responsible for any claims arising from the use of the DC Master in the life support equipment. 2.4 GUARANTEE SPECIFICATIONS Mastervolt guarantees that this unit has been built according to the legally applicable standards and specifications. Should work take place, which is not in accordance with the guidelines, instructions and specifications contained in this user s manual, then damage may occur and/or the unit may not fulfil its specifications. All of these matters may mean that the guarantee becomes invalid. The guarantee is limited to the costs of repair and/or replacement of the product. Costs for installation labor or shipping of the defective parts are not covered by this guarantee. Refer to your terms of delivery for the guarantee period. 4 February 2015 / DC Master 24/12 50A / EN

INSTALLATION 3 INSTALLATION 3.1 BEFORE YOU START WARNING During installation and commissioning of the DC Master, the Important Safety Instructions are applicable at all times. See chapter 2 of this manual. Make sure that the battery voltage is the same as the input voltage of the DC Master (24V battery for a 24V input voltage). Fuses must be integrated in the positive wires. These fuse(s) shall be placed last of all. Recommended fuses: Input fuse Output fuse Remote switch fuse Recommended Fuse 50A 60A 2A - T Keep the cable connections as short as possible, Recommended maximum length of the DC cables: 3 m / 10ft. If available, use coloured battery cables: Red for positive, black for negative. Recommended wire gauges: AWG Metric Input wires (24V) 8 AWG 10 mm² Output wires (12V) 6 AWG 16 mm² Remote switch (24V) 16 AWG 1.5 mm² 3.2 CHOOSING A LOCATION TO INSTALL For an optimal optimum heat discharge, the DC Master must be installed in a well-ventilated room protected against rain, vapour, moisture and dust. We advise to mount the unit in a vertical position with the connecting cables downward. Never use the DC Master at a location where there is danger of gas or dust explosions. Allow at least 10 cm / 4 inch space around the apparatus. Do not mount the DC Master straight above the batteries because of possible corrosive fumes. 3.3 CONTENTS OF THE DELIVERY: DC Master 24/12 50-60A Mounting bracket 4x screws, 4x screw covers, 4x mounting spacers A 5-way terminal block + wire bridge This user s manual; If one of these items is missing, please contact your supplier. 3.4 INSTALLATION STEP-BY-STEP 1 Carefully remove the mounting bracket from the DC Master using a flat-blade screwdriver. Use the provided screws and dowels to mount the bracket to a solid and flat surface. Insert the DC Master in the mounting bracket and press it down until it clicks into place. 2 See figure 2. Connect the wires as indicated, but do not place the DC fuse(s) yet. Connect the input wires first, and then connect the output wires. a. Without remote switch function: place the supplied wire bridge between Enable contact (3) and Positive input (1); b. With remote switch function: remove the supplied wire bridge and install Remote switch fuse (8) and Remote switch (9) as indicated. 3 Check all wiring. If OK, place the DC fuse(s). When the fuse is placed, internal capacitors may cause a spark. This is normal. 8 7 9 a b 1 + 24V 1 = Positive input (27.2V) 6 = Status LED 2 = Negative input (0V) 7 = Input fuse 3 = Enable (Active high) 8 = Remote switch fuse 4 = Negative output (0V) 9 = Remote switch 5 = Positive output (13.6V) 10 = Output fuse Figure 2: Wiring diagram 2 3 4 5 10 + 13.6V Load Belasting Last Charge Carico Carga 6 EN / DC Master 24/12 50A / February 2015 5

OPERATION TROUBLE SHOOTING 4 OPERATION 4.1 SWITCHING ON AND OFF The DC Master does not have a main switch; it is enabled by inserting the fuse, refer to chapter 3. Despite its low no-load consumption, the converter should be disconnected from the supplying battery when it is not in use to protect the battery from discharging. 4.2 REMOTE SWITCH FUNCTION The DC Master can be operated remotely by means of an optional remote switch. See figure 2, reference 9. If the ENABLE input is powered by the input voltage, the DC Master is switched on. 4.3 STATUS LED See Figure 2. The Status-LED (ref. 7) shows the operation mode of the DC Master. LED indication Meaning Continuous green DC Master is working OK Other Fault condition, refer to chapter 5. 4.4 MAINTENANCE No specific maintenance is required. If necessary, use a soft clean cloth to clean the DC Master. Do not use any liquids or corrosive substances, such as solvents, alcohol, petrol or abrasive components. Check the wiring on a regular base. Defects such as loose connections, burnt wiring etcetera must be corrected immediately. 5 TROUBLE SHOOTING If you cannot solve a problem with the aid of this chapter, contact your local Mastervolt Service Centre. See www.mastervolt.com/dealer-locator. Make sure you have the article and serial number (See section 1.4) present if you have to contact your local Mastervolt Service Center to solve a problem: Problem Possible cause What to do? Output voltage is OK, High load Reduce connected load Status LED yellow Output voltage is OK, Status LED yellow blinking @ 1Hz Output voltage is OK, Status LED yellow blinking @ 2Hz Converter switches on and off. No output voltage, Status LED is OFF No output voltage, Status LED flashing green No output voltage, Status LED is continuous red. No output voltage, Status LED is blinking red. Too high load Too high temperature Too high load Too high temperature Voltage drop over DC cables Loose connections Input fuse blown Enable contact is open No input voltage or input voltage too low. Input voltage too low Input voltage too high Converter is shut down due to a fault condition (too high load, short circuit, too high temperature) Converter was shut down several times due to a fault condition Reduce connected load, output power is limited by the DC Master Reduce load and let the converter cool down. Output power is limited by the DC Master Reduce connected load Reduce load and let the converter cool down. Check cable length and wire gauge Check connections and replace if necessary Check the cause of the blown input fuse(s). Then replace the fuse(s). Connect Enable contact to the positive input (see section 3.4 and 4.2) Check wiring, fuses and battery. Check battery voltage, cable length, wire gauge Check battery voltage Reduce load and let the converter cool down. Converter will automatically restart after 1 minute Reduce load and let the converter cool down. Converter must be restarted manually by switching off and on the DC input voltage 6 February 2015 / DC Master 24/12 50A / EN

TECHNICAL DATA 6 TECHNICAL DATA 6.1 SPECIFICATIONS Model 24/12 50A Article no. 81400352 Function Nominal input voltage: 27.2 V (18.0-32.0 V) Max. input current Non isolated 24V to 12V DC DC converter 30A Nominal output voltage: 13,6 V +/- 5% Output current Ripple Parallel fitting Efficiency at full load >90% No load consumption (on/off) Temperature range Cooling Connections 50 A continuous, 60 A peak during 2 minutes @ 30 C [86 F] 2% of output voltage Yes, up to 4 DC Masters of the same model 15 / 5 ma -25 to +80 C [-13 to 176 F]. Load must be reduced at temperatures between 35 and 80 C [86 and 176 F]. Natural convection 5-way terminal block for wires 1.5mm up to 16mm² [16 up to 6 AWG]. Stripping length: 14mm [0.55 inch]. Tightening torque: 1.7 1.8 Nm [15-16 InLbs] Dimensions in mm (inch): 283 x 125 x 74 mm [11.14 x 4.92 x 2.91 inch] see also section 6.2 Weight in kg : Protection degree IP 53 1.8 kg [4.0 lbs] Specifications are subject to change without prior notice. 6.2 DIMENSIONS 126 [5.0] 1 2 272 [10.7] 58 [2.3] 33 [1.3] 75 [3.0] 84 [3.3] 45 [1.8] 193 [7.6] Figure 3: Dimensions in mm [inch] EN / DC Master 24/12 50A / February 2015 7

EC DECLARATION OF CONFORMITY 7 EC DECLARATION OF CONFORMITY We, Manufacturer Mastervolt Address Snijdersbergweg 93 1105 AN Amsterdam The Netherlands Declare under our sole responsibility that Product: DC-DC-converter Model: 81400352 DC Master 24/12 50-60A Is in conformity with the provisions of the following EC directives: 2004/108/EC (EMC directive); the following harmonized standard has been applied: EN 60945: 2002 Maritime navigation and radio communication equipment and systems 2011/65/EU (RoHS directive) Amsterdam, 11 February 2015 H.A. Poppelier Global R&D Leader Snijdersbergweg 93, 1105 AN Amsterdam, The Netherlands Tel : + 31-20-3422100 Fax : + 31-20-6971006 Email : info@mastervolt.com