Quick Start Guide. Tek-Flux 1400A. 796 Tek Drive, Crystal Lake, IL USA

Similar documents
TEK-F LUX 1400A. Electromagnetic Flowmeter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys FLOW

Manual Elektromagnetisk Flödesmätare EMFM Manual

Appendix. Clearance. Skewed profiles. Application Schematics

TEK-B AR 3110A. Differential Pressure Transmitter. Flow Level Temperature Pressure Valves Analyzers Accessories TekValSys PRESSURE

유량계전문제조업체. Electro Magnetic FLOWMETER

Instruction Manual. DMF-1-Series Coriolis Mass Flow Meter

Options guide. Electromagnetic flowmeters. M9xx

Ultra Mag SUBMITTAL PACKAGE

Model TUR-200D Turbine Flowmeter

F-1500 SERIES INSERTION TURBINE FLOW METER

Product Data Sheet 2012 Rev 5 FLOWMETRIX SA SAFMAG Electromagnetic Flowmeter Doc Date

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Electromagnetic flowmeter EMKO E

SITRANS F M flow sensors 711/A and 711/911E

Magnetic-inductive flow meter for hazardous areas

DY-LWGY Liquid turbine flow meter

WaterMAG. Electromagnetic Flowmeter for Water Applications. Model MCB10A OVERVIEW APPLICATIONS FEATURES. No. SS2-MCB

WATER METERS OCTAVE ULTRASONIC WATER METER INSTALLATION & USER GUIDE

ISTEC MAGNETIC METERS

F-2700 SERIES INSERTION VORTEX FLOW METER

Liquid Turbine Flow Meter OwnerÊs Manual

Electromagnetic flowmeter. Descriptions. Specifications

Range of Ultrasonic Flowmeters.

EGM1100C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

KTLDE Intelligent Electromagnetic Flowmeter

FLS F6.60 MAGMETER FLOW SENSOR INSERTION FLOW SENSORS APPLICATIONS MAIN FEATURES

F-2600 SERIES INLINE VORTEX FLOW METER

ULTRASONIC FLOW SENSOR QALCOSONIC FLOW 2

F-1500 SERIES INSERTION TURBINE FLOW METER FEATURES Belcher Road South, Largo, FL USA Tel +1 (727) Fax +1 (727)

CATALOG KTLU. Vortex Flowmeter

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

From. McCROMETER, INC WEST STETSON AVENUE HEMET, CA Phone (951) Toll Free (800) Fax (951)

ABB Instrumentation. MagMaster MFE Series Electromagnetic Sensors. Specifications. MagMaster - bringing unsurpassed flowmetering performance

Detector (for water measurement applications)

Model 5000 Vortex Meter

9900 Series Oval Flowmeter/Transmitter with SMART METER MANAGER

EGM5300C MAGMAX. Compact Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

Sidel Therm & CO 2 Counter Instruction & Installation Manual

Field IT Electro-Magnetic Flowmeters Sensors

Ultrasonic Flowmeter. M-1500 Plus Non-invasive Inline DSP Ultrasonic Flowmeter. Operating Principle. Features

OPERATOR TROUBLESHOOTING GUIDE

FT-3100 ONICON. Inline Electromagnetic Flow Meter Installation and Operation Manual. Flow and Energy Measurement

MULTICHANNEL ULTRASONIC FLOW METER AFLOWT UF

F-2700 SERIES INSERTION VORTEX FLOW METER

Model 1000 Vortex Meter

Micro Motion F-Series Coriolis Flow and Density Sensors. Installation Manual , Rev CC December 2010

Electro-Magnetic Flowmeters Sensors MagMaster MFE

ProSeries NEMA 4X SONIC-PRO. Engineering and Technical Data. Transit Time Ultrasonic Flowmeter. Industries, Ltd. s Ultrasonic Flow Meters

Rosemount 8750WA Magnetic Flowmeter System For Water and Wastewater Industries

Abridged Specifications: 10D1477 Electrodeless Sensor with 50XM1000 Transmitter

ELECTROMAGNETIC FLOWMETERS INSTALLATION, OPERATION AND MAINTENANCE MANUAL

STEEMCO-MAS Flowmeter for Steam

MagFlux Q 8200 Series

Flow Transmitter / Switch OMNI-RR..32

tekson TS Series Low Cost Ultrasonic Water Energy Flow Measurement

MEASURE TODAY. ENSURE TOMORROW. SpireMag Series T-MAG Electromagnetic BTU Meter

Turbine Flow Meter Model: LW

Sentinel Panametrics Custody Transfer Gas Ultrasonic Flowmeter

Magnetic Inductive Flowmeter EP / UMF2 (B)

INTERNATIONAL METAL ENGINEERING

ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products Rev PK KMS501W & KMS502F- TW. Electromagnetic TRADEWASTE Flowmeters FEATURES:

Insertion magnetic inductive flowmeter

Sentinel. Panametrics Custody Transfer Gas Ultrasonic Flowmeter. GE Sensing. Applications. Features

CATALOG KVFN. Vortex Flowmeter

The Polaris MA1 is the first liquid flow meter offered by Magnetrol, expanding the already diverse level and flow measurement portfolio that has been

TIDALFLUX 2300 F Quick Start

Water Solutions For Global Needs

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

STEEMCO Flowmeter for Steam

The 285 Annubar Primary Element Series

Octave Water Meter Installation Manual

Ensuring Premium Performance with Foxboro I/A Series Pulsed dc Magnetic Flowmeters

USER S GUIDE Installation & Operation Instructions DCP PRO METER ELECTROMAGNETIC FLOW METER (DC PULSED)

HH5 Variable Area Flow meter

Electromagnetic Flowmeter for Partially-filled Pipes

Instructions EM 101 Low Flow Electromagnetic Flow Meters

Masoneilan Series

ULTRASONIC FLOWMETER / HEATMETER

INSTRUCTIONS SITRANS F M MAGFLO Electromagnetic flowmeter type MAG 1100 FOOD, DN 10 - DN 100

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

UniMag DT Series Electromagnetic Flow Tubes

Technical Information Proline Promag 10L

ULTRASONIC FLOW SENSOR IFX-M4-01

Type Operating Instructions. Bedienungsanleitung Manuel utilisateur

Installation & Operation Manual

Model 3051 Sensor Module Replacement

Operating Instructions. Angle Seat Control Valve. Type 7020

Gas Turbine Flow Meter

DYNAMETERS SERIES DMTF ULTRASONIC FLOW METER

CATALOG KVFN. Vortex Flowmeter

WATERFLUX 3070 Quick Start

EM101 LOW FLOW MAGNETIC FLOWMETER INSTRUCTIONS

Model UYF200, UYFA21 Ultrasonic Vortex Flowmeters (Style Code:S2)

Flow Transmitter / Switch OMNI-RR..32

Model 8800C Vortex Flowmeter

Installation and Operation Instructions DLP Series

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

Electromagnetic flowmeters

MagneW Neo+ Two-wire Electromagnetic Flowmeter Integral type TIIS Explosion-protected Apparatus

75 OHM COAXIAL CABLE (RG6)

Transcription:

796 Tek Drive, Crystal Lake, IL 60014 USA +1 847 857 6076 +1 847 655 7428 +1 847 655 6147 www.tek-trol.com

1. Before you begin Before installation check the model, specifications, and installation location for the transmitter. Follow the full User Guide for detailed installation and other information. Verify that the operating atmosphere of the flow tube and transmitter is consistent with the appropriate hazardous locations certifications Do not remove the transmitter cover in explosive atmospheres when the circuit is alive Before connecting a HART-based communicator in an explosive atmosphere, make sure the instruments in the loop are installed in accordance with intrinsically safe or nonincentive field wiring practices Make sure only qualified personnel perform the installation Do not perform any service other than those contained in this manual unless qualified 2. Unpack Electromagnetic Flowmeter 3. Meter Handling All parts should be handled carefully to prevent damage. Whenever possible, transport the system to the installation site in the original shipping containers. The flow tube is shipped with end covers to protect it from mechanical damage and normal unrestrained distortion. End covers should not be removed until just before installation. Keep shipping plugs in conduit connections until conduits are connected and sealed. 796 Tek Drive, Crystal Lake, IL 60014 USA +1 847 857 6076 +1 847 655 7428 +1 847 655 6147 www.tek-trol.com

4. Dimensions Technology Solutions Note: For additional dimensions, refer to the detailed manual. 5.7" (147mm) n-d 5.5" (140mm) n-d n-d L Sensor (½"to 3") L B 240mm 9.4" 169mm 6.6" 85mm 3.3" 4.84" 123mm H 2.9" (75mm) H H L Direct Mount Type ( 4") L Remote Mount Type ( 4 ) B Sensor(½" to 3") Outline dimension of medium and High Pressure Sensor Direct Mount Transmitter

5. Display has a two-line backlit LCD display which measures forward and reverse flow and is used to set parameters, password, menu control, and memory function. Display for direct mount transmitter Alarm indicator +282.92 FQH / Σ + 000000013.5 G Flow volume Unit Flow velocity (FLS) Percentage (FQP ) Ratio of emptiness (MTP) Forward and reverse intergated volumes Deference of forward and reverse Alarm Display for remote type transmitter Enter Up /plus 1/page up Down/ minus 1/ page down Compound +282.92 Flow volume Down Up Compound & Down Compound & Up Enter Alarm indicator Key function for self testing Down Up Enter Compound & Enter Key functions for parameter setting FQH / Σ + 000000013.5 G Unit Flow velocity (FLS) Percentage (FQP ) Ratio of emptiness (MTP) Forward and reverse intergated volumes Deference of forward and reverse Alarm Enter Up /plus 1/page up Down/ minus 1/ page down Compound Selecting displayed data in lower lines Selecting displayed data in higher lines Press it to come into the interface To enter parameter setting Subtract 1 from the number above cursor Plus 1 to the number above cursor To shift cursor to left To shift cursor to right To enter or exit the submenu Note: When using "Compound" key, you should press "Compound" key and "Up" or "Down" simultaneously 796 Tek Drive, Crystal Lake, IL 60014 USA +1 847 857 6076 +1 847 655 7428 +1 847 655 6147 www.tek-trol.com

+ + + + + + + + + + + + Technology Solutions 6. Power Supply wiring Wiring for direct mount transmitter L 2 L 1 COM I+ COM P+ AH AL FUSE + + + + + T+ G T- I+ Output Current for Flow Measurement COM Output Current (Ground) for Flow Measurement P+ Frequency(Pulse) Output for Bi-directional Flow COM Frequency (Pulse) Output (Ground) AL Alarm Output for Low Limit AH Alarm Output for Upper Limit COM Alarm Output (Ground) FUSE Fuse for Power Supply T +Communication Input Signal T -Communication Input Signal G RS232 Communication Ground L1 220VAC(24VDC) Power Supply L2 220VAC(24VDC) Power Supply

Wiring for remote type transmitter L N PCOM ACOM ACOM TRX+ TRX- T C O M E X T + E X T - D S 1 M T S R D S 2 PO U T A LM L ALM H VDIN IOUT ICOM SIG1 SGND SIG2 PE POWER PE To the mounting sensor SIG1 Signal1 SGND Signal Ground SIG2 Signal2 DS1 Shielded Exciting1 DS2 Shielded Exciting2 EXT+ Exciting Current+ EXT- Exciting Current- Analog Current Output VDIN Current Two lines 24V Spots ICOUT Analog Current Output ICCOM Analog Current Output Ground Frequency (Pulse) Output POUT Flow Frequency (Pulse) Output PCOM Frequency (Pulse) Output Ground Two Alarm Outputs ALMH Upper Limit Alarm Output ALML Low Limit Alarm Output ALCOM Alarm Output Ground Communication Input TRX+ Communication Input TRX- Communication Input ALCOM 232 Communication Ground Cable should be no more than 100m to prevent accuracy and interference. transmitter should be installed closely to sensor as much as possible. 796 Tek Drive, Crystal Lake, IL 60014 USA +1 847 857 6076 +1 847 655 7428 +1 847 655 6147 www.tek-trol.com

Technology Solutions Note: For remote type flowmeter, when flow conductivity is more than 50µS/cm, flow signal cable should be shield signal cable with polyvinyl chloride jacket and metal net; when flow conductivity is less than 50µS/ cm or the signal is transmitted for long distance, double shield signal cable with equipotential double cores should be used. 7. Grounding If flowmeter is installed in a metal pipeline, there should be no insulating coating on pipeline in wall. If flowmeter is installed in a pipeline with insulating paint, grounding rings should be used on the sensor for both sides. If flowmeter is installed in a pipeline with cathodic protection, with inner and outer surface insulated, then the grounding rings and flange should be insulated as well.

Note: Flowmeter sensor part should have separate grounding cable, whose sectional area of copper core should be 1.6mm 2, ground resistance should be <10Ω. 8. Mounting of flowmeter The correct mounting point is important to flowmeter use. Mounting the meter wrong may influence measuring accuracy, life of meter, or may cause damage The axis for measuring electrode shall be approximate to horizontal direction (included angle with horizontal line shall be no more than 10 ) 10 10 9. Installation At upstream side of the flowmeter, there should be straight pipe no less than 5D and no less than 2D at flowmeter downstream. 5D 2D Install flowmeter at relative low of horizontal pipe or in upward vertical direction. Do not install the flowmeter at the highest point of pipe and in the downward vertical direction. 796 Tek Drive, Crystal Lake, IL 60014 USA +1 847 857 6076 +1 847 655 7428 +1 847 655 6147 www.tek-trol.com

Technology Solutions Install flowmeter at the rising pipe. For installing at open pipe, flowmeter should be installed at relative low position. If the fall in the pipe is more than 5m, vent valve should be installed at sensor downstream where it should have back pressure. Exhaust Valve 5m Control valve and stop valve should be installed at the downstream of sensor and not at the upstream side. Sensor should be installed at the outlet of pump and not at the inlet. Note: Ensure that the pipe is filled with fluid at all times Flow direction of fluid shall be in accordance with arrow direction on the flowmeter

Technology Solutions 796 Tek Drive Crystal Lake, IL 60014 USA Tel : +1 847 857 6076, +1 847 655 7428 Fax : +1 847 655 6147 Email: tektrol@tek-trol.com www.tek-trol.com