Direct Current Switch with Built-in Magnetic Blowout

Similar documents
Ordering Information. General-purpose Basic Switch X. Direct Current Switch with Built-in Magnetic Blowout. Model Number Legend

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

Low-torque Basic Switch

D2SW. Sealed Subminiature Basic Switch. Ordering Information Model Number Legend D2SW-

Subminiature Basic Switch

Digital display Pressure range ON/OFF output Linear output Model

2NC (slow-action) Direct. Model. opening

Multiple Limit Switch

Best-selling Basic Switch Boasting High Precision and Wide Variety

Ratings 1 A at 125 VAC 1 A at 30 VDC LED indicator Without indicator With indicator Without indicator With indicator Actuator

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Best-selling Basic Switch Boasting High Precision and Wide Variety

OMRON Z LIMIT SWITCH

Model Number Structure

Best-selling Basic Switch Boasting High Precision and Wide Variety

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Operation Key D4BS - K Head Mounting Direction F: Four mounting directions possible (front-side mounting at shipping)

D4GS-N CSM_D4GS-N_DS_E_7_2

(3) Terminals. 00: AC connector. Comparison of New and Old Molded Terminal Models. Model Location of lead outlet

Features. Emergency Stop Switch A165E. Separate Construction with Smallest Class of Depth in the World. Safety Lock Prevents Misuse

D4BS CSM_D4BS_DS_E_8_4

HL Economical, Miniature Limit Switch Boasting Rigid Construction. General-purpose Limit Switch. Specifications. Model Number Structure

G3PE-Single-phase. Solid State Relays for Heaters

2NC (slow-action) Direct. Model. opening

Safety Limit Switch

D2SW-P. Sealed Subminiature Basic Switch. Ordering Information D2SW-P

Limit Switches Technical Information

Best-selling Basic Switch Boasting High Precision and Wide Variety

Detection of Incorrectly Set Work Press Position Confirmation Detection of Bent Drills. Press D5C

Ordering Information. Snap Action Switch D2F. Subminiature Snap Action Switch D2F- Model Number Legend. Snap Action Switch D2F 31

A165E CSM_A165E_DS_E_11_2

0.5 s to 30 h (30 s, 3 min, 30 min, 3 h, 30 h)

Subminiature Basic Switch

A165S/W. Separate Construction with Cylindrical 16-dia. Body. Knob-type Selector Switch (Detachable) (Cylindrical 16-dia.

Applicable output load (See note 2.) Photocoupler Yes Yes 40 A at 110 to 220 VAC 5 to 24 VDC G3NB-240B 5 to 24 VDC G3NB-240B-UTU 5 to 24 VDC

D2VW. Sealed Miniature Basic Switch Conforms to IP67 (Excluding the terminals on terminal models) Model Number Legend. Sealed Miniature Basic Switch

D2SW-AQ. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D4NS. Safety-door Switch. Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch. Model Number Structure

Miniature Limit Switches

Ordering Information. Specifications. Motor Time Switch H2F-WM. Accessories (Order Separately) Time Specifications. Ratings

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

Small Limit Switch D4V

D4NH. Safety-door Hinge Switch. Compact, Plastic-body Safety-door Hinge Switch Designed for Saving Space in Machines and Other Equipment

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

G6K. Surface Mounting Relay with the World s Smallest Mounting Area. Application Examples. Model Number Legend. Ordering Information

D2SW. Sealed Subminiature Basic Switch Conforming to IP67 (Excluding the terminals on terminal models) Model Number Legend

D4BL. Guard Lock Safety-door Switch

D2HW. Sealed Ultra Subminiature Basic Switch. Ordering Information

D2AW. Long stroke seal switch with high reliability and high insulation performance. Model Number Legend. Sealed Ultra Subminiature Basic Switch

Input terminals Isolation method Zero cross function Operation indicator Alarm output Applicable load (See note.) Model

M2S. Indicator Series with Square 40-mm Body. Indicator (Square) List of Models

D4NH CSM_D4NH_DS_E_7_1

D4BL. Guard Lock Safety-door Switch

A22LK CSM_A22LK_DS_E_6_2

Applicable Terminal Relay Rated voltage Model G6D-F4B 12 VDC G6D-1A (see note) 24 VDC 12 VDC G6D-1A-AP (see note) 24 VDC G3DZ-F4B 12 VDC G3DZ-2R6PL

Model Number Structure

Enclosed Switch. Ordering Information. Economical, High Utility Enclosed Switch. Model Number Legend D4MC- List of Models

High Operating Precision Basic Switches with High Capacity and Long Life

Solid State Relays G3NA. Model Number Structure. Model Number Legend

CSM_D4N-_R_DS_E_6_1

Safety Guard Switching Unit G9SX-GS

D4BL. Guard Lock Safety-door Switch. Die-cast aluminum body Key holding force of 700 N. Model Number Structure. Model Number Legend Switch D4BL - K

TURQUOISE STROKE SWITCHES

2 to 25 A, 100 to 240 VAC G3PF-225B-STB Compact slotted

Safety Limit Switch

Model Number Legend (Completely Assembled)... Shipped as a set which includes the Operation Unit, Lamp (lighted models only), and Switch. 4.

Ultra-miniature Size Switches with High Precision AH 1. Actuator. 0: Pin plunger 2: Hinge lever 4: Simulated roller lever N 0.25N 0.

Sliding contact construction Switches for Low-level Loads

Ordering Information. Motor Time Switch H2F-D. Accessories (Order Separately) ON/OFF Control 48 Times per Day in 15-min Increments

Smile 11 RA/-B Smile 12 RF/-G Reset button

High-power Solid State Relays G3PH

D4BS. Safety-door Switch. Model Number Structure. Switch D4BS - S Operation Key D4BS - K. Ordering Information

Sense7-series Non-contact coded safety switch

TURQUOISE STROKE SWITCHES

D2MV. Highly reliable Miniature Basic Switch in spite of its Ultra-low Load action. Model Number Legend. List of Models.

Technical Guide for Basic Switches

HL (AZH) LIMIT SWITCHES

EStrong-series Emergency Stop

Turquoise Stroke Mini Switches

D4DL. Guard Lock Safety-door Switch. Model Number Structure

Turquoise Stroke Switches

Pre-wired Models D4C- (1) (2) (3) (4)

A3S. Pushbutton Switch Series with Square 40-mm Body. Lighted Pushbutton Switch (Square) List of Models

Technical Explanation for Basic Switches

D4DS. Compact Interlock Safety Door Switch. Compact Safety Switch Saves Space and is Ideal for a Variety of Doors. Refer to Precautions on page 9.

3. Terminal Shape P : PCB terminals FS: Surface-mounting terminals, short FL : Surface-mounting terminals, long

E bracket (see note 1) SPST-NO G7L-1A-TJ-CB G7L-1A-BJ-CB DPST-NO G7L-2A-T-CB G7L-2A-B-CB

Safety Relay Unit G9S

D2D. Door Interlock Power Switch with Minimum Contact gap of 3 mm. Model Number Legend. Contact Form. List of Models. Contact Specifications.

Safety-door Switch. Ordering Information

Model Number Structure

Tina 11A Connection block

Cautions in Using The Relays 1/5

Hinged Safety Door Switch

Small, High-precision Enclosed Switch. Enclosed Switch. Model Number Structure (1) Ordering Information. Model Number Legend (1) Actuator

Ordering Information. Text Surface-Mounting Signal Relay G6K

Life PERFORMANCE Catalog listing Standards Structure Electrical performance Mechanical performance Ambient operating conditions Recommende tightening

List of Models Short post on Long post on left left. Without posts Actuator Terminals Contact form

Tina 4A Connection block

Technical Information Solid State Relays. Glossary. Solid State Relays

Transcription:

General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Same shape and mounting procedures as the Z Basic Switches. Be sure to read Safety Precautions on page 6 and Safety Precautions for All Basic Switches. Model Number Structure Model Number Legend X-G@-@ (1) (2)() (4) (1) Ratings : A (125 VDC) (2) Contact Gap G : 0.9 mm () Actuator None : Pin plunger D : Short spring plunger S : Slim spring plunger Q : Panel mount plunger Q21 : Panel mount cross roller plunger Q22 : Panel mount roller plunger L : Leaf spring W : Hinge lever W2 : Hinge roller lever W21 : Short hinge lever W22 : Short hinge roller lever W4 : Low-force hinge lever M : Reverse hinge lever M2 : Reverse hinge roller lever M22 : Reverse short hinge roller lever (4) Terminals None : Solder terminal B : Screw terminal (with toothed washer) Ordering Information Terminal Solder terminal Screw terminal Actuator Model Model Pin plunger X-G X-G-B Slim spring plunger X-GS X-GS-B Short spring plunger X-GD X-GD-B Panel mount plunger X-GQ X-GQ-B Panel mount roller plunger X-GQ22 X-GQ22-B Panel mount cross roller plunger X-GQ21 X-GQ21-B Leaf spring X-GL X-GL-B Short hinge lever X-GW21 X-GW21-B Hinge lever X-GW X-GW-B Low-force hinge lever X-GW4 X-GW4-B Short hinge roller lever X-GW22 X-GW22-B Hinge roller lever X-GW2 X-GW2-B Reverse hinge lever X-GM X-GM-B Reverse short hinge roller lever * X-GM22 X-GM22-B Reverse hinge roller lever * X-GM2 X-GM2-B * The plungers of reverse-type models are continuously pressed by the compression coil springs and the plungers are freed by operating the levers. 1

Specifications X Ratings Rated voltage 8 VDC 14 VDC 0 VDC 125 VDC 250 VDC Note: 1. The above values are for the steady-state current. 2. Inductive load has a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC).. Lamp load has an inrush current of times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. 5. The above electrical ratings also apply to the AC voltage. 6. With the reverse-type models (X-GM@), the normally closed circuits and normally open circuits are reversed. 7. The ratings values apply under the following test conditions: (1) Ambient temperature: 20±2 C (2) Ambient humidity: 65±5%RH () Operating frequency: 20 operations/min Certified Standard Ratings Ask your OMRON representative for information on certified models. UL/CSA EN (CE) (Conform to EN658-1) Characteristics *1. The values are for the pin plunger models. (Contact your OMRON representative for other models.). Malfunction: 1 ms max. Structure Non-inductive load (A) Resistive load Contact Form (SPDT) Lamp load Inductive load (A) Inductive load Motor load NC NO NC NO NC NO NC NO 1.5 1.5 1.5 1.5 1.5 0.75 7.5 2 Rated voltage Model X-G 125 VDC A 250 VDC A Rated voltage Model X- 50 VDC A 6 1.5 5 5 5 5 2 2.5 2.5 2.5 2.5 1.5 Operating speed 0.1 mm to 1 m/s *1 Operating Mechanical 240 operations/min frequency Electrical 20 operations/min Insulation resistance 0 MΩ min. (at 500 VDC) Contact resistance 15 mω max. (initial value) 1,500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between Dielectric strength current-carrying metal parts and the ground, and between each terminal and non-currentcarrying metal parts Vibration resistance Malfunction to 55 Hz, 1.5-mm double amplitude Shock Destruction 1,000 m/s 2 max. resistance Malfunction 00 m/s 2 max. *1 Durability Mechanical 1,000,000 operations min. Electrical 0,000 operations min. Degree of protection IP00 Degree of protection against electric shock Class I Proof tracking index (I) 175 Ambient operating temperature 25 C to 80 C (with no icing) Ambient operating humidity 5% to 85%RH Weight Approx. 27 to 6 g Contact Specification Contacts Inrush current Material Gap (standard value) NC NO Engineering Data Mechanical Durability (X-G) Durability (x 4 operations) 5,000,000 1,000 700 500 00 200 0 70 50 0 20 0 Ambient temperature: 20±2 C Ambient humidity: 65±5%RH Without load Operating frequency: 240 operations/min 0.1 0.2 0. 0.4 0.5 0.6 0.7 0.8 0.9 Overtravel (mm) Electrical Durability (X-G) Durability (x 4 operations) 500 00 200 0 70 50 0 20 7 5 2 1 0 125 VDC L/R = 7 ms Ambient temperature: 20±2 C Ambient humidity: 65±5%RH Operating frequency: 20 operations/min 125 VDC L/R = 0 2 4 6 8 12 14 Switching current (A) Silver 0.9 mm 0 A max. 15 A max. (+) COM NC NO Note: With the reverse-type models (X-GM@), the NC and NO terminal arrangements are reversed. 2

Dimensions Terminals Screw Terminals (-B) 9.2 20 20 17.45±0.2 X (Unit: mm) Mounting Use M4 mounting screws with plane washers or spring washers to securely mount the Switch. Tighten the screws to a torque of 1.18 to 1.47 N m. Two, 4.2-dia. mounting holes or M4 screw holes 25.4±0.1 COM NO NC 1 2 49.2 Three, M4 5.5 Terminal screws (with toothed washer) Solder Terminal (-A) ("-A" is not included in the model numbers.) The Switch can be panel mounted, provided that the hexagonal nut of the actuator is tightened to a torque of 2.94 to 4.9 N m. Panel Mount Plunger Panel Mount Roller Plunger +0.2 +0.2 12.5 0 dia. 12.5 0 dia. 6.4 5 +0.2 0 25.4±0.1 11.9 17.45±0.2 1 +0.2 0 1 NO COM NC 2 49.2 Note: 1. Tighten the terminal screws to a torque of 0.78 to 1.18 N m. 2. Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.. In case of DC voltage, set the COM to the positive terminal.

X Dimensions and Operating Characteristics The models, illustrations, and graphics are for screw-terminal models. (The dimensions for models that are omitted here are the same as for pin-plunger models.) Pin Plunger X-G-B 2.±0.25 +0.075 4.2-0.025 dia. hole 2. dia. 2.SR *1 Slim Spring Plunger X-GS-B 2.±0.25 *1 5.2 dia. 4 dia. 4.2 +0.075-0.025 9.2 24.2 9 dia. 24.2 +0.1 4.6-0.05 dia. 25.4±0.1 49.2 11.9 17.45±0.2 *1. Stainless-steel pin plunger *1. Stainless-steel pin plunger (flat, 1R chamfering) Short Spring Plunger X-GD-B 2.±0.25 12SR *1 12. dia. dia. 7.15 dia. 24.2 Panel Mount Plunger X-GQ-B 1.1 * 16. 16 dia. 8.5 dia. 2.±0.25 11.9SR M12 1 mounting screw *1 Two hexagonal nuts (2 t 14 width across flats) Two lock nuts (2 t 15.6 width across flats) *1. Plated iron plunger *1. Stainless-steel pin plunger *. Incomplete screw part with a maximum length of 1.5 mm Note: Do not use both the M12 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. Panel Mount Roller Plunger X-GQ22-B 2.±0.25 12.7 dia. 4.8 *1 Panel Mount Cross Roller Plunger X-GQ21-B 2.±0.25 12.7 dia. 4.8 *1 M12 1 mounting screw M12 1 mounting screw 15.5 * Two hexagonal nuts ( t 17 width across flats) 15.5 * Two hexagonal nuts ( t 17 width across flats) 16. 16 dia. 16. 16 dia. *1. Stainless-steel roller *. Incomplete screw part with a maximum length of 1.5 mm. Note: Do not use both the M12 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. *1. Stainless-steel roller *. Incomplete screw part with a maximum length of 1.5 mm. Note: Do not use both the M12 mounting screw and the mounting holes in the case at the same time. Doing so will cause stress to be applied to the Switch, possibly damaging the case or cover. Leaf Spring X-GL-B 49.6±0.8 t = 0. *1 4.8 *1. Stainless-steel spring lever Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Operating Characteristics Model X-G-B X-GS-B X-GD-B X-GQ-B X-GQ22-B X-GQ21-B X-GL-B Operating force OF max. Release force RF min. Pretravel max. Overtravel OT min. Movement Differential MD max. Free Position max. Operating Position 5.00 N 1.12 N 0.9 mm 0.1 mm 0.18 mm 15.9±0.4 mm * Be sure to use the switch at the rated OT value of 1.6 mm. 5.00 N 1.12 N 0.9 mm 1.6 mm 0.18 mm 28.2±0.5 mm 5.00 N 1.12 N 0.9 mm 1.6 mm 0.18 mm 21.2±0.5 mm 5.00 N 1.12 N 0.9 mm 5.5 mm 0.18 mm 21.8±0.8 mm 5.00 N 1.12 N 0.9 mm.6 mm 0.18 mm.4±1.2 mm 5.00 N 1.12 N 0.9 mm.6 mm 0.18 mm.4±1.2 mm 1.96 N 0.14 N 1.6 mm * 2. mm 22.1 mm 17.4±0.8 mm 4

X Short Hinge Lever X-GW21-B 26.2 28.2R t = 1 *1 4.9 Hinge Lever X-GW-B 26.2 6.5R t = 1 *1 4.9 14.4 14.4 9.2 4.2 +0.075-0.025 +0.075 4.2-0.025 dia. holes +0.1 4.6-0.05 dia. 17.45±0.2 25.4±0.1 11.9 *1. Stainless-steel lever 49.2 *1. Stainless-steel lever Low-force Hinge Lever X-GW4-B 26.2 6.5R t = 1 *1 14.4 4.9 Short Hinge Roller Lever X-GW22-B t = 1 *1 26.2 26.6R 14.4 9.5 dia. 4 plastic roller *1. Stainless-steel lever *1. Stainless-steel spring lever Hinge Roller Lever X-GW2-B Reverse Hinge Lever X-GM-B 26.2 48.5R *1 t = 1 14.4 9.5 dia. 4 plastic roller 18.65 56R t = 1 *1 14.4 4.9 *1. Stainless-steel lever *1. Stainless-steel lever Reverse Short Hinge Lever X-GM22-B 18.65 18.5R t = 1*1 14.4 9.5 dia. 4 plastic roller Reverse Hinge Roller Lever X-GM2-B 18.65 40.6R *1 t = 1 14.4 9.5 dia. 4 plastic roller *1. Stainless-steel lever *1. Stainless-steel lever Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. Model Operating Characteristics OF max. RF min. max. OT min. MD max. max. X-GW21-B X-GW-B X-GW4-B X-GW22-B X-GW2-B X-GM-B X-GM22-B X-GM2-B 2.45 N 0.1 N 2.1 mm 1.7 mm 25.5 mm 20.7±0.8 mm 1.08 N 0.14 N 4.8 mm.9 mm 4.6 mm 21.1±0.8 mm 0.25 N 0.05 N 14. mm 4.8 mm.9 mm 21.1±0.8 mm 2.16 N 0.4 N 2.4 mm 1.7 mm 7.1 mm 2.2±0.8 mm 1.42 N 0.21 N 4 mm mm 40.5 mm 2.2±0.8 mm 2.16 N 0.25 N 5.5 mm 2.1 mm 26.8 mm 21.1±0.8 mm 6.86 N 1.52 N 2 mm 0.75 mm 6.1 mm 2.2±0.8 mm.14 N 0.49 N 4 mm 1.5 mm 7.4 mm 2.2±0.8 mm 5

Safety Precautions X For details, be sure to read Safety Precautions for All Basic Switches. Terminal Connection When soldering lead wires to the Switch, make sure that the capacity of the soldering iron is 60 W maximum. Do not take more than 5 s to solder any part of the Switch. The characteristics of the Switch will deteriorate if a soldering iron with a capacity of more than 60 W is applied to any part of the Switch for 5 s or more. Operation Make sure that the switching frequency or speed is within the specified range. 1.If the switching speed is extremely slow, the contact may not be switched smoothly, which may result in a contact failure or contact welding. 2.If the switching speed is extremely fast, switching shock may damage the Switch soon. If the switching frequency is too high, the contact may not catch up with the speed. The rated permissible switching speed and frequency indicate the switching reliability of the Switch. The life of a Switch is determined at the specified switching speed. The life varies with the switching speed and frequency even when they are within the permissible ranges. In order to determine the life of a Switch model to be applied to a particular use, it is best to conduct an appropriate durability test on some samples of the model under actual conditions. Make sure that the actuator travel does not exceed the permissible OT position. The operating stroke must be set to 70% to 0% of the rated OT. Mounting Location Do not use the switch alone in atmospheres such as flammable or explosive gases. Arcing and heat generation associated with switching may cause fires or explosions. Switches are generally not constructed with resistance against water. Use a protective cover to prevent direct spraying if the switch is used in locations subject to splashing or spurting oil or water, dust adhering. Install the switch in a location that is not directly subject to debris and dust from cutting. The actuator and the switch body must be protected from accumulated cutting debris and dirt. Precautions for Safe Use Precautions for Use Terminal box Terminal box Do not use the switch in locations subject to hot water (greater than 60 C) or in water vapor. Do not use the switch outside the specified temperature and atmospheric conditions. The permissible ambient temperature depends on the model. (Refer to the specifications in this catalog.) Sudden thermal changes may cause thermal shock to distort the switch and result in faults. Mount a cover if the switch is to be installed in a location where worker inattention could result in incorrect operation or accidents. (preventing malfunctions) Separate the installation location from heat sources. Subjecting the switch to continuous vibration or shock may result in contact failure or faulty operation due to abrasion powder and in reduced durability. Excessive vibration or shock will cause the contacts to operate malfunction or become damaged. Mount the switch in a location that is not subject to vibration or shock and in a direction that does not subject the switch to resonance. If silver contacts are used with relatively low frequency for a long time or are used with microloads, the sulfide coating produced on the contact surface will not be broken down and contact faults will result. Use a microload switch that uses gold contacts. Do not use the switch in atmospheres with high humidity or heat or in harmful gases, such as sulfide gas (H2S, SO2), ammonia gas (NH), nitric acid gas (HNO), or chlorine gas (Cl2). Doing so may impair functionality, such as with damage due to contacting faults or corrosion. The switch includes contacts. If the switch is used in an atmosphere with silicon gas, arc energy may cause silicon oxide (SiO2) to accumulate on the contacts and result in contact failure. If there is silicon oil, silicon filling, silicon wiring, or other silicon products in the vicinity of the switch, use a contact protection circuit to limit arcing and remove the source of the silicon gas. Handling Set the common (COM) terminal to the positive terminal. If it is set to the negative terminal, the Switch will not turn OFF. When using the Switch under an inductive load, the arc suppression capability varies depending on current. If the current becomes 0.6 to 1.2 A or of the time constant L/R exceeds 7 ms, be sure to provide an arc suppressor. Since the Switch incorporates a permanent magnet, attention must be paid to the following points: (a) Avoid mounting the Switch directly onto a magnetic substance. (b) Do not subject the Switch to severe shocks. (c) Avoid placing the Switch in a strong magnetic field. (d) Be sure to prevent iron dust or iron chips from adhering to the built-in magnet or the magnetic blowout function of the Switch will be adversely affected. (e) Do not apply thermal shock to the Switch, or the magnetic flux will be diminished. Since a ventilation hole is provided to avoid abnormal corrosion due to operating conditions, provide a dustproofing device in locations where the Switch is exposed to dust. 6

X Do not change operating positions for the actuator. Changing the position may cause malfunction. Panel-mounted Model (X-GQ@) To side-mount the panel-mount Switch to the panel with screws, remove the hexagonal nut from the actuator. Too large a dog angle and too fast operating speed may damage the Switch when the Switch is side-mounted on the panel. Too fast operating speed and too long overtravel of the roller plunger Switch may result in damage to the Switch. Accessories (Order separately) Refer to Z/A/X/DZ Common Accessories for details about Terminal Covers, Separators, and Actuators. 7

Safety Precautions for All Basic Switches For the individual precautions for a Switch, refer to the precautions in the section for that Switch. Always observe the following cautions to ensure safety. Mounting Before mounting, dismounting, wiring, or inspecting a switch, be sure to turn OFF the power supply to the switch, otherwise an electric shock may be received or the switch may burn. Wiring Do not perform wiring when power is being supplied to a switch. Also, do not touch any of the charged terminals when power is being supplied. Otherwise, electric shock may be received. Follow the instructions provided in Use for all wiring and soldering work. Using a switch with improper wiring or soldering may result in abnormal heating when power is supplied, possibly resulting in burning. Contact Load Select suitable switch ratings after confirming contact load. If the contact load is excessive for the contacts, the contacts may weld or shift, possibly resulting in short-circuits or burning when power is supplied. Load Types Some types of load have a large difference between steady-state current and inrush current, as shown in the following diagram. Select a switch with ratings suitable for the type of load. The higher the inrush current in the closed circuit is, the more the contact abrasion or shift there will be. Consequently, contact welding or shifting may occur, possibly resulting in short-circuits or burning. Types of Load vs. Inrush Current I (A) Solenoid ( to 20) Precautions for Safe Use Precautions for Use For details, refer to the Precautions for Use in the Basic Switches Technical Guide. Incandescent lamp ( to 15) Motor ( 5 to ) Relay ( 4 to 5) Operating Atmosphere Do not use switches in atmospheres containing combustible or explosive gases. Arc or heat generated by switching may cause fires or explosions. Shock on Individual Switches Do not drop or disassemble switches. Not only will characteristics be jeopardized, but also damage, electric shock, or burning may result. Durability The durability of a switch greatly varies with switching conditions. Before using a switch, be sure to test the switch under actual conditions in the actual application and to use the switch within the switching operations causing no problem. If a deteriorated switch is used continuously, insulation failures, contact welding, contact failures, switch damage, or switch burnout may result. t C-1

Precautions for Use of Basic Switches Technical Guide for Basic Switches Using Switches When switches are actually used, unforeseen accidents may occur. Before using a switch, perform all possible testing in advance. Unless otherwise specified, ratings and performances given in this catalog are for standard test conditions (i.e., 15 to 5 C, 25% to 75% humidity, and 86 to 6 kpa atmospheric pressure). When performing testing in the actual application, always use the same conditions as will be used in actual usage conditions for both the load and the operating environment. Reference data provided in this catalog represents actual measurements from production samples in graph form. All reference data values are nominal. All ratings and performance values provided in this catalog are the results of a single test each rating and performance value therefore may not be met for composite conditions. Selecting Switch Select an appropriate switch for the operating environment and load conditions. Use the Selection Guide to select a suitable switch for the rated current, operating load, actuator type, and operating environment. It is not recommended to use a switch for a large current to switch a micro current, in terms of contact reliability. Select a switch that is suitable for the current actually being switched. Consider using a sealed switch in environments subject to water droplets. Electrical Conditions 1. Operating Load The switching capacity of a switch significantly differs depending on whether the switch is used to break an alternating current or a direct current. Be sure to check both the AC and DC ratings of a switch. The control capacity will drop drastically if it is a DC load. This is because a DC load, unlike an AC load, has no current zero cross point. Therefore, if an arc is generated, it may continue for a comparatively long time. Furthermore, the current direction is always the same, which results in contact relocation phenomena, and the contacts hold each other with ease and will not separate if the surfaces of the contacts are uneven. If the load is inductive, counter-electromotive voltage will be generated. The higher the voltage is, the higher the generated energy is, which increase the abrasion of the contacts and contact relocation phenomena. Make sure to use a switch within the rated conditions. If a switch is used for switching both micro and high-capacity loads, be sure to connect relays suitable to the loads. The rated loads of a switch are according to the following conditions: Inductive Load: A load having a minimum power factor of 0.4 (AC) or a maximum time constant of 7 ms (DC). Lamp Load: A load having an inrush current ten times the steady-state current. Motor Load: A load having an inrush current six times the steadystate current. Note: It is important to know the time constant (L/R) of an inductive load in a DC circuit. Inrush Current I (A) 2. Using Switches with Electronic Circuits If bouncing or chattering of the contacts results and causes problems, take the following countermeasures. (a) Insert an integral circuit. (b) Suppress the generation of pulse from the contact bouncing or chattering of the contacts so that it is less than the noise margin of the load. Use microload switches that use gold contacts particularly if high contact reliability is required. In order to protect the Switch from damage due to short-circuits, be sure to connect a quick-response fuse with a breaking current 1.5 to 2 times larger than the rated current to the Switch in series. When complying with EN approved ratings, use a -A IEC 60269- compliant gi or gg fuse.. Using Switches for Micro Loads Contact faults may occur if a Switch for a general-load is used to switch a micro load circuit. Use switches in the ranges shown in the diagram on the right. However, even when using micro load models within the operating range shown here, if inrush current occurs when the contact is opened or closed, it may increase contact wear and so decrease durability. Therefore, insert a contact protection circuit where necessary. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% (λ60). The equation, λ60 = 0.5 6 /operations indicates that the estimated malfunction rate is less than 1/2,000,000 operations with a reliability level of 60%. Voltage (V) 0 5 mw 0.16 ma 800 mw 26 ma i (Inrush current) 24 Operating range for micro-load models Operating range for standard models 12 Unusable range 5 1 ma 0 ma 160 ma io (Steady-state current) t 0 0.1 1 0 1,000 Current (ma) C-2

Technical Guide for Basic Switches 4. Contact Protective Circuit Apply a contact protective circuit (e.g., surge protector) to increase the contact durability, prevent noise, and suppress the generation of carbide or nitric acid. Be sure to apply the contact protective circuit correctly. Otherwise, an adverse effect may occur. The following provides typical examples of contact protective circuits. If the Switch is used in an excessively humid location for switching a load that easily generates arcs, such as an inductive load, the arcs may generate NOx, which will change into HNO if it reacts with moisture. Consequently, the internal metal parts may corrode and the Switch may fail. Be sure to select the ideal contact preventive circuit from the following. Also, load operating times may be delayed somewhat if a contact protective circuit (a surge killer) is used. Typical Examples of Contact Protective Circuits (Surge Killers) CR circuit Circuit example Power supply C R Inductive Power load supply O: Applicable : Not applicable Δ: Conditional Applicable current Feature Element selection AC DC Δ * Diode method Power Inductive O supply load C R Inductive load O O O * When AC is switched, the load impedance must be lower than the C and R impedance. The operating time will increase if the load is a relay or solenoid. It is effective to connect the CR circuit in parallel to the load when the power supply voltage is 24 or 48 V and in parallel to the contacts when the power supply voltage is 0 to 200 V. Energy stored in the coil is changed into current by the diode connected in parallel to the load. Then the current flowing to the coil is consumed and Joule heat is generated by the resistance of the inductive load. The reset time delay in this method is longer than that of the CR method. C: 0.5 to 1 μf per switching current (1 A) R: 0.5 to 1 Ω per switching voltage (1 V) The values may change according to the characteristics of the load. The capacitor suppresses the spark discharge of current when the contacts are open. The resistor limits the inrush current when the contacts are closed again. Consider these roles of the capacitor and resistor and determine the ideal capacitance and resistance values from experimentation. Use a capacitor with a dielectric strength between 200 and 00 V. When AC is switched, make sure that the capacitor has no polarity. If, however, the ability to control arcs between contacts is a problem for high DC voltage, it may be more effective to connect a capacitor and resistor between the contacts across the load. Check the results by testing in the actual application. The diode must withstand a peak inverse voltage times higher than the circuit voltage and a forward current as high as or higher than the load current. Diode and Zener diode method Power supply Inductive load O This method will be effective if the reset time delay caused by the diode method is too long. Zener voltage for a Zener diode must be about 1.2 times higher than the power source since the load may not work under some circumstances. Varistor method Inductive O O Power load supply This method makes use of constant-voltage characteristic of the varistor so that no high-voltage is imposed on the contacts. This method causes a reset time delay more or less. It is effective to connect varistor in parallel to the load when the supply voltage is 24 to 48 V and in parallel to the contacts when the supply voltage is 0 to 200 V. Select the varistor so that the following condition is met for the cut voltage Vc. For AC currents, the value must be multiplied by 2. Vc > (Current Voltage 1.5) If Vc is set too high, however, the voltage cut for high voltages will no longer be effective, diminishing the effect. Do not apply contact protective circuit as shown below. C Power supply Load This circuit effectively suppresses arcs when the contacts are OFF. The capacitance will be charged, however, when the contacts are OFF. Consequently, when the contacts are ON again, short-circuited current from the capacitance may cause contact weld. C Power supply Load This circuit effectively suppresses arcs when the contacts are OFF. When the contacts are ON again, however, charge current flows to the capacitor, which may result in contact weld. Connections With contact form Za, do not connect a power supply of different polarity or different types to one switch. Example of Power Supply Connection Example of Power Supply (Connection with Different Polarity) Connection (Connection with Different Type of Power Supply) There is a danger of AC and DC NC becoming mixed. NO L AC NC DC NO Do not use a short-circuited circuit if a fault occurs. (Doing so may cause the current-carrying parts to fuse.) L NC NO L NC NO NC NO L Connect the load to the same polarity side. C-

Technical Guide for Basic Switches Mechanical Conditions 1. Operating Stroke Setting The setting of stroke is very important for a switch to operate with high reliability. The chart below shows the relationship among operating force, stroke, and contact force. To obtain high reliability from a switch, a switch actuator must be manipulated within an appropriate range of operating force. Be sure to pay the utmost attention when mounting a switch. Make sure that the operating body is set so that the actuator should return to the free position when the operating body has moved if a switch is used to form a normally closed (NC) circuit. If a switch is used to form a normally open (NO) circuit, the operating body must move the switch actuator to the distance of 70% to 0% of the rated overtravel (OT) of the switch. If stroke is set in the vicinity of the operating position () or the releasing position (RP), contact force may become unstable. As a Operating force Contact force Release Release TTP Operating body Install a stopper. 70% of rated OT 0% of rated OT Setting range (Pretravel) Stroke Stroke (Free position) (Operating position) OT (Overtravel) TTP (Total travel position) Distance to the optimum setting range. result, the switch cannot ensure high reliability. Furthermore, the switch may malfunction due to vibration or shock. If stroke is set exceeding the total travel position (TTP), the moment of inertia of the operating body may damage the actuator or the switch itself, and the stress applied to the moving spring inside the switch will increase and then, the durability of the switch may be deteriorated. 2. Switching Speed and Frequency The switching frequency and speed of a switch have a great influence on the performance of the switch. Pay attention to the following. If the actuator is operated too slowly, the switching operation may become unstable, causing contact failures or contact welding. If the actuator is operated too quickly, the switch may be damaged by shock. If the switching frequency is too high, the switching of the contacts cannot catch up with the operating speed of the actuator. If the operating frequency is extremely low (i.e., once a month or less frequent), a film may be generated on the surface of the contacts, which may cause contact failures. The permissible switching speed and switching frequency of a switch indicate the operational reliability of the switch. The durability of a switch is based on operation under specific conditions regarding the switching speed and switching frequency. The durability of a switch may not meet the durability due to conditions even if the switch is operated within the permissible switching speed and frequency ranges. Test a switch sample under the actual conditions to ascertain its durability.. Operating Condition Do not leave a switch with the actuator depressed for a long time, otherwise the parts of the switch may soon deteriorate and the changes of its characteristics operating may result. 4. Operating Method The operating method has a great influence on the performance of a switch. Consider the following before operating a switch. Design the operating body (i.e., cam or dog) so that it will operate the actuator smoothly. If the actuator snaps backwards quickly or receives shock due to the shape of the operating body, its durability may be deteriorated. Snap-back Shock operation Snap-back Shock operation Make sure that no improper force is applied to the actuator, otherwise the actuator may incur local abrasion. As a result, the actuator may become damaged or its durability may be deteriorated. Dog Roller Operating body Operating body Make sure that the operating body moves in a direction where the actuator moves. If the actuator is a pin plunger type, make sure that the operating body presses the pin plunger vertically. Operating body Operating body C-4

Technical Guide for Basic Switches Operate the actuator of a hinge roller lever or simulated hinge lever type in the direction shown below. Mounting Location Do not use the switch alone in atmospheres such as flammable or explosive gases. Arcing and heat generation associated with switching may cause fires or explosions. Switches are generally not constructed with resistance against water. Use a protective cover to prevent direct spraying if the switch is used in locations subject to splashing or spurting oil or water, dust adhering. Set the angle of the cam or dog (θ) for roller levers and similar actuators to the range θ between 0 and 45. If the angle is too large, an abnormally large horizontal stress will be applied to the lever. Do not modify the actuator. If the actuator is modified, excessive external force may be applied to the internal switch mechanism, characteristics may change, and the switch may stop functioning. If an external actuator is used as an operating object, check the material and thickness of the lever to make sure that the force applied to the lever is within the permissible range. Mounting 1. Securing When mounting a switch, be sure to use the specified mounting screws and tighten the screws with flat washers or spring washers securely. However, the switch housing may incur crack damage if it comes into contact with the spring washers directly. In that case make sure that the flat washers come into contact with the switch housing as shown below. Do not subject the switch to excessive shock or highfrequency vibrations when mounting (e.g., do not use an impact driver) as it may cause contacts stick or switch damage. Install the switch in a location that is not directly subject to debris and dust from cutting. The actuator and the switch body must be protected from accumulated cutting debris and dirt. Terminal box Terminal box Do not use the switch in locations subject to hot water (60 C min.) or in water vapor. Do not use the switch outside the specified temperature and atmospheric conditions. The permissible ambient temperature depends on the model. (Refer to the specifications in this catalog.) Sudden thermal changes may cause thermal shock to distort the switch and result in faults. Screw Flat washer Spring washer Separate the installation location from heat sources. Resin Do not modify the switch in any way, for example, by widening the mounting holes. Locking Agent If glue or locking agent is applied, make sure that it does not stick to the moving parts or intrude into the inside of the switch, otherwise the switch may have operating failure or contact failure. Some types of glue or locking agent may generate gas that has a bad influence on the switch. Pay the utmost attention when selecting glue or locking agent. Wiring Make sure that the lead wires are connected with no inappropriate pulling force. Terminal box Terminal box Mount a cover if the switch is to be installed in a location where worker inattention could result in incorrect operation or accidents. (preventing malfunctions) Subjecting the switch to continuous vibration or shock may result in contact failure or faulty operation due to abrasion powder and in reduced durability. Excessive vibration or shock will cause the contacts to operate malfunction or become damaged. Mount the switch in a location that is not subject to vibration or shock and in a direction that does not subject the switch to resonance. If silver contacts are used with relatively low frequency for a long time or are used with microloads, the sulfide coating produced on the contact surface will not be broken down and contact faults will result. Use a microload switch that uses gold contacts. Do not use the switch in atmospheres with high humidity or heat or in harmful gases, such as sulfide gas (H2S, SO2), ammonia gas (NH), nitric acid gas (HNO), or chlorine gas (Cl2). Doing so may impair functionality, such as with damage due to contacting faults or corrosion. C-5

Technical Guide for Basic Switches The switch includes contacts. If the switch is used in an atmosphere with silicon gas, arc energy may cause silicon oxide (SiO2) to accumulate on the contacts and result in contact failure. If there is silicon oil, silicon filling, silicon wiring, or other silicon products in the vicinity of the switch, use a contact protection circuit to limit arcing and remove the source of the silicon gas. Maintenance and Inspection Make sure that a switch is mounted in locations that allow easy inspection or replacement of the switch. Difficult to inspect Easy to inspect Operation and Storage Environment 1. Handling Do not apply oil, grease, or other lubricants to the sliding parts of a switch. The intrusion of oil, grease, or other lubricants into the internal part may cause operating failure or contact failure. 2. Storage Environment When storing a switch, consider countermeasures (e.g., storing in a plastic bag) to prevent discoloration resulting from sulphurisation of terminals (silver-plated). Make sure that the location is free of harmful gas and does not have high temperature or humidity. It is recommended that a switch be inspected before use if it is stored for three months or more after the production, depending on the location. The cover must be located in the direction ensuring ease of maintenance or inspection. Mounting Direction When using a switch with a low operating force mounted with a long lever, make sure that the switch is mounted in the direction where the weight of the lever is not applied to the pushbutton directly, otherwise the switch may have releasing failures. 2. Terminal Connections Solder Terminals When soldering lead wires to a switch, make sure that the temperature of the iron tip is 80 C maximum. Improper soldering may cause abnormal heat radiation from the switch and the switch may burn. Complete soldering within 5 seconds at 50 C or within seconds at 80 C. If heat is applied for longer period of time, switch characteristics will be deteriorated, e.g., the case will melt and lead wire insulation will scorch. Quick-Connect Terminals Use the specified receptacles to connect to quick-connect terminals. Do not apply excessive force horizontally or vertically to the terminals, otherwise the terminal may be deformed or the housing may be damaged. Wiring Work When wiring a switch, check the insulation distance between the switch and the mounting plate. If the insulation distance is insufficient, use an insulation guard or separator. Be particularly careful when mounting a switch to metal. Use wire sizes suitable for the applied voltage and carrying current. Do not wire a switch while power is being supplied. Using Separators If providing sufficient insulation distance is a problem or there are metal components or copper wire near a switch, use a switch with an insulation guard or use a separator (order separately) to provide sufficient insulation distance. SEPARATOR FOR Z Separator C-6

Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specifi ed) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS, OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PRERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPRRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. At the customer's request, OMRON will provide applicable third party certifi cation documents identifying ratings and limitations of use that apply to the products. This information by itself is not suffi cient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PRERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT IS PRERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifi cations and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when signifi cant construction changes are made. However, some specifi cations of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fi x or establish key specifi cations for your application on your request. Please consult with your OMRON representative at any time to confi rm actual specifi cations of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. ERRORS AND OMISSIONS The information in this catalog has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. CYRIGHT AND CY PERMISSION This catalog shall not be copied for sales or promotions without permission. This catalog is protected by copyright and is intended solely for use in conjunction with the product. Please notify us before copying or reproducing this catalog in any manner, for any other purpose. If copying or transmitting this catalog to another, please copy or transmit it in its entirety. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ 2007. In the interest of product improvement, specifications are subject to change without notice. (c)copyright OMRON Corporation 2007 All Rights Reserved.