ECO CFL. with Photocell. Instructions. Model: ECO2DD Model: ECO3DD

Similar documents
Model: ECO1FL Model: ECO2FL Model: ECO3FL. Installation & Operating Instructions ECO CFL Flood Light Uncontrolled

18W Low Energy. instructions. Instructions

3000W Dusk to Dawn Light Controller

Dedicated PIR Light Controller c/w RF remote control for LEDPRO Floodlights

2x 10W LED Slimline Floodlight Twin Flood

25W LED Cross Bezel Bulkhead Light

18W Round LED Slimline Emergency Light

10W LED Die Cast Small Rectangle Bulkhead Light

I n s t a llat ion & O p e r atin g In s truc t ions

24 Hour Mechanical Time Switch with Voltage Free Contacts

Adjustable Pneumatic Time Delay Switch

24 Hour Immersion Heater Time Controller

Wireless Digital Room Thermostat with Night Set-Back

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

Compact Security FloodLight

Installation & Operating Instructions

Round Pattern 24 Hour Electromechanical Time Controllers with Half Day & Day Omit

PROFESSIONAL 270 o PIR MOTION DETECTOR

PMWS2W SURFACE MOUNT 2-WIRE WALL SWITCH

ASSEMBLY & FITTING INSTRUCTIONS P-LUX3 LED TRI-SENSOR LANTERN

INSTALLATION & OPERATING INSTRUCTIONS

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

Installation Instructions

PIL0478 ISSUE 01/ 07/16

Mightylite Elite 16W LED Wall Light with PIR

Motion and Light Sensor Kit LHBAS51

MOTION-ACTIVATED WALL LANTERN

120 LED DUAL HEAD SOLAR MOTION LIGHT

Installation Instructions

Specification Sheet for 2D LED Light

Security Lighting INSTRUCTION MANUAL 16W, 28W, 36W & 50W PIR Security LED Floodlight

28W WORK LAMP Model: CTL28 Part No:

INSTRUCTIONS FOR OUTDOOR WALL LANTERN, MODEL LPT-1032

ASSEMBLY AND INSTALLATION INSTRUCTIONS

Installation Instructions: Eco SpunBay LED High Bays

LyteLaunch Dry - Wet and DMX Models. Operation Manual

INSTALLATION & MAINTENANCE MANUAL HBL

LIGHTING Autumn & Winter Offers 2018/2019

Installation Manual GT500 GT500R RAB

ASSEMBLY AND INSTALLATION INSTRUCTIONS

LED Security Wallpack Installation Instruction

6 x 10 Belt Disc Sander

IR600 Infra-red Lamp

Bulbs are not included. FF-OF4 Octa 4 Socket Fluorescent Fixture INSTRUCTIONS

Installation Instructions

1 Safety instructions. 2 Device components. Light Management LED touch dimmer insert. Art. No LEDDE. Operating instructions

INSTALLATION INSTRUCTIONS

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

Bayside Model BU2050 Installation, Maintenance, and Operation Manual

Motion Sensing Coach Light

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

DUALBRITE Motion Sensing Coach Light

Magnetic Mount 60 Watt Low Profile LED Flood Light - Glare Shield - 10' Cord V AC

Lumination TM LED Luminaire LUR Series

D.fm Page 1 Wednesday, March 5, :21 PM Raptor user manual

INSTALLATION INSTRUCTION MANUAL

EVZ Series (Small body) Explosion protected luminaire Operating Instructions

UL AND CODE COMPLIANCE

Demand Switch NEFA20 Plus. Installation Guide. Please read this entire guide before beginning the installation!

POST LANTERN ITEM # MODEL #PL125BK PL125WW. Français p. 10. Español p. 19 ATTACH YOUR RECEIPT HERE. Serial Number.

User s Manual. Automatic Switch-Mode Battery Charger

Measurements are expressed in millimeters.

TRAILBLAZER LIGHTING TRAILBLAZER LIGHTING

The Powermatic User Guide Test Sieve Shaker

IR125 & IR300 Infra-red Lamps

Single gang PIR switch Replaces a standard light switch or dimmer Turns off automatically Turns on automatically Security mode Switches all lighting,

P/N Wheeler. user manual

OCTA FLUORESCENT 7 SOCKET FIXTURE

High quality die cast aluminium with glass diffuser

With magnetic fixing With ON/OFF switch

BAL1400 FLUORESCENT EMERGENCY BALLAST Specification-grade One or two-lamp emergency illumination

HLS Watt Halogen Illuminator Service Manual

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

Lastolite Lastolite Lumen8 F200 Lumen8 F400 Stored Energy Guide Number (m/100iso) Recycling Time (100%) Flash Duration Flash Power

Installation Instructions

Floodlight Range Installation Guide

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

MLD-44S/g V AC/50-60Hz. MLD-28S/g. MLD-34S/g

Meet the family. Five year warranty. thornlighting.co.uk/warranty

MAINTAINED LED CIRCULAR EMERGENCY CEILING LIGHT

Meet the family. Five year warranty. thornlighting.co.uk/warranty

Meet the family. Five year warranty. thornlighting.co.uk/warranty

WHEN USING ELECTRICAL EQUIPMENT, BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE OBSERVED INCLUDING THE FOLLOWING:

OWNER S OPERATING MANUAL

IMPORTANT SAFEGUARDS

Installation and Maintenance Manual (2014)

Sieve Shaker 200mm/300mm - 8/12 inch SV003

Compact 150 Watt Motion Sensing Halogen

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

Meet the family. Five year warranty. thornlighting.co.uk/warranty

USER MANUAL LUX-LD30W LED MOVING HEAD

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

THE INTELLIGENT MOTION SENSOR TRACKING LIGHT

HEAVY DUTY BATTERY BOOSTERS / CHARGERS. MODEL Nos. BC260N & BC335 OPERATING & MAINTENANCE INSTRUCTIONS

LEDWP LED Wall Pack Light - 400W Metal Halide Equivalent - 12 LEDs - 10ft Cord High Output

LED Recessed Troffer Retrofit Kit

SAVE THESE INSTRUCTIONS

Car Battery Charger Instructions for Use

Meadow Park, Bourne Road, Essendine, Stamford, Lincolnshire, PE9 4LT Tel Fax Web.

Dimmer / 2-Way Dimmer

Transcription:

ECO1DD WITHModel: PHOTOCELL Model: ECO2DD Model: ECO3DD ECO1DD.1 ECO2DD.1 Instructions ECO3DD.1 I nn S& TORp eurca tti ni O Installatio g N I n Ss t r u c t i o n s ECO CFL ECOFlood CFL Light with Photocell FLOOD LIGHT

2x 2x 20W 4 x 32mm 1 ø 6mm 60mm 35mm 6 x 30mm

2 Slaving For ECO CFL Flood Light Uncontrolled Unit only For ECO1DD & ECO2DD only 23W Max

PAN 30º Tilt 60º 23W Max For ECO3DD only For ECO1DD & ECO2DD only 3 Lamp turns ON at night. Lamp turns ON at day & night.

1. General Information This floodlight features an integral daylight sensing motion which will automatically switch the light on based on environment lux level and at a time set by the user. Unit is for outdoor use only. Unit must be mounted as a fixed luminaire, and is not suitable for portable use. 2. Parts Included Low Energy Floodlight with photocell sensor. Instruction manual. Please keep safe for future reference. Accessory Pack including screws and wall plugs. 1pc. 20W low energy Compact Fluorescent Light. (For ECO1DD & ECO3DD) 2pcs 20W low energy Compact Fluorescent Light. (For ECO2DD) 3. Tools & Parts Needed 4 3 flexible core cable (1.0mm² or 1.5mm²). Electric/hand-held drill & bits. Terminal or Electricians screwdriver. Wire cutters. Do not attempt to install during wet weather, if you are suffering from nausea or dizzy spells or on medication with similar side effects. No User Serviceable Parts Inside

4. Installation IMPORTANT Switch off the electricity at the fuse box by removing the relevant fuse or switching off the circuit breaker before proceeding with the installation (Diagram 2). After choosing a suitable location install the unit as follows: The unit is suitable for connection to a 240 V ac 50Hz electricity supply. It is suggested that 3-core round flexible cable of 1mm² or 1.5mm² gauge is used. An internal switch should be installed to switch the power to the unit. This allows the unit to be easily switched off when not required or for maintenance purposes. This unit uses an integral wall fixing plate, detach the wall fixing plate by unscrewing and release but do not remove the fixing screw on the underside of the wall plate (Diagram 3). 5 Mark the position of the wall fixing holes (60mm). Ensure the wall plate is correctly positioned. Note the UP indent on the inside of the wall plate. Drill the holes, insert the wall plate into the holes. Pierce and pass the cable through the grommet before securing the wall plate to the wall. It is recommended that the grommet is pierced with a screwdriver to ensure a better seal. (Diagram 4). Fix the wall plate to the wall with screws provided. Connect the cable to the terminal block on the unit as follows (Diagram 5): Neutral (Blue ) N EARTH (Green/ Yellow) LIVE (Brown) L Ensure Connections are secure. The unit is supplied with a hanging attachment (tether) to aid installation. Ensure the tether is securely fixed into the slot before releasing the weight of the unit. (Diagram 6)

To connect another unit of floodlight, connect the looping power cable to the terminal block on the master unit as follows ( Diagram 7 ): Neutral (Blue) N EARTH (Green/ Yellow) LIVE (Brown) L Fit the floodlight to the bracket by inserting the catch in the floodlight into the recess at the top of the wall plate and locating the floodlight securely over the wall plate. Fit and fully secure the locating screw (Diagram 3). For ECO1DD & ECO2DD To fit the CFL, release but do not remove the screw on the front cover of the floodlight, open and rotate down but do not separate from the main floodlight body. (Diagram 8) For ECO3DD 6 To fit the bulb, turn the lamp enclosure 180 anti-clockwise to release from the bayonet lock. (Diagram 10) Remove the bulbs from its packaging and fit into the lampholders. Ensure the bulb is fully secured into the lampholder and the support bracket is located around the bulb. Close the front cover, ensure the screw is fully tighten. This floodlight uses a universal joint, it can be directed to suit your installation by rotating the floodlight left to right and up or down. (Diagram 9)

5. Operation and Testing Setting Up For Automatic Operation The Sensor Head can be panned 90 degree to left and 90 degree to the right. (Diagram 10) The adjustment controls on the unit (Diagram 11) should be set as follows. The TIME control determines how long the lamp remains illuminated after activation (1 hour to 12 hours). These settings allow the lamp to illuminate for the designated time on period after darkness falls and the unit is activated. The DUSK (LUX) control determines the level of darkness required for the unit to start operating. (Diagram 12) The setting is best achieved by the procedure below: Set the DUSK control knob fully anti-clockwise and the Time control to the required minutes. Wait until darkness falls. 7 When the ambient light level reaches the level of darkness at which you wish the lamp to become operative (ie. At dusk), SLOWLY rotate the control in a clockwise direction until a point is reached where the lamp illuminates. Leave the control set at this point. At this position, the unit should become operative at approximately the same level of darkness each evening. Observe the operation of the unit. If the unit is starting to operate too early (ie. when it is quite light), adjust the control slightly anticlockwise. If the unit starts to operate too late (ie. only when it is very dark), adjust the control slightly clockwise. Continue to adjust until the unit operates as desired.

6. Technical Specifications Power Supply 230V AC ~ 50Hz Maximum External Load Number of Slave Unit No other external loads can be used. 8 Master ECO1FL ECO2FL ECO3FL ECO1DD 3 1 3 ECO2DD 2 1 2 ECO3DD 3 1 3 Lamp Type 230 AC 20W Compact Fluorescent lamp supplied E 27 base 23W compact fluorescent maximum Do not use incandescent or halogen bulbs Time On Adjustment 1 hour to 12 hours Dusk Level Adjustment Day & night or night only operation Environmental Protection IP45 (suitable for outdoor use)

6. Troubleshooting Guide Problem Solution Lamp stays OFF Check that the power is switch ON at the wall switch. Ensure no connections are loose Ensure that CFL is seated correctly in the lamp holder. Check the CFL. If the CFL has failed, replace it. If you experience problems refer to Troubleshooting Guide. If problems still exist, do not immediately return the unit to store. Telephone the Timeguard Customer Helpline 020 8450 0515 9 Qualified Customer Support Co-ordinators will be on-line to assist in resolving your query. No User Serviceable Parts Inside.

3 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 3 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 and 3 or any difficulty in the first year telephone the helpline on 020 8450 0515. Note: the lamp is not covered by the warranty. 10