20th Dec, aptis range

Similar documents
MCCBs : Low voltage protection devices

About us. Switchgear Factory, Mumbai

DX³ 4-pole RCBO 6000 A/10 ka

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

DPX moulded case circuit breakers

MINIATURE CIRCUIT BREAKER

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

The young energy ensures more safety

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

NeoBreak Distribution System MCBs, RCCBs & DBs

AN ISO 9001:2015 COMPANY

MINIATURE CIRCUIT BREAKERS RCBO s & DIN RAIL MOUNTED FUSE HOLDERS

Miniature Circuit Breaker

INDIAN INSTITUTE OF TECHNOLOGY KANPUR

TX³ RCCBs 2P up to 100 A

COMPLETE SOLUTIONS FOR POWER PROTECTION

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCCBs - ID 4P up to 100 A

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

01 Spectra Plus - Introduction

Domae. The right solution for distribution boards

Residential and light commercial. invicta. panelboards

New DX 3 High rating & breaking capacity

Phase + Neutral, neutral on right side

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Perfection that Matters

Phase + Neutral, neutral on left side

NS Feeder pillar up to 3200A

xboard safety, reliability effectively combining and performance safety, reliability and performance in commercial and industrial applications

R.C.B.O. SP / 1 module

Power distribution & protection

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

RESIDUAL CURRENT CIRCUIT BREAKER

Tender Schedule. Sl. No. Particulars Quantity Unit Rate `

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

DX³ RCBO 6000A Phase + Neutral, neutral on left

Total Cost Abstract. Project Name : - RDPL, Jaipur. Grand Total

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

Amount (Rs) 1.5 sq. mm ISI marked, FR

Manual Motor Starters. Meta-MEC

Wall mounted switchgear

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

Electrician. Handbook L&T SWITCHGEAR SAFE & SURE

Range 16A to 63A. Sensitivity 30mA, 100mA, 300mA, 500mA. Execution Double Pole, Four Pole. Specification IEC / IS : 2000

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

STANDARD SPECIFICATION FOR. LIGHTING AND DC DISTRIBUTION PANELS WITH MCBs DOCUMENT NO: 44LK-5100/E.02/011

Estimate For The Electrical Works At Pittakayagulla Branch Sl.N Particulars Quantity Unit Rate Amount

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Power distribution & protection

DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

DPX 1600 Electronic release

Tender Schedule for Electrical Works at Varagani Branch. Sl. No. Particulars Quantity Unit Rate Amount

Name of work : Electrification of PG Block Second Floor in V.P.S.V Ayurveda college Kottakkal.

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Series KTU7 UL489 Molded Case Circuit Breakers

novello SPN distribution boards

(Miniature Circuit Breaker)

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DX³ RCBO 6000A Phase + Neutral, neutral on right

up to 63 A (1 module per pole)

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Miniature circuit-breaker (MCB) SH200M Series

Innovation That Leads the Change

XL 3 -N SimPly, EfficiEnt And SAfE. 3 - PHASE distribution boards up to 250 A

S200 UL 489 Series. Miniature circuit breakers S200. Features. Description

Relax... you re in safe hands CONSUMER UNITS / PRODUCT GUIDE.

NPS/003/010 - Technical Specification for 400V Assemblies (LVAC Boards) utilised in Major Substations

MCCB Accessories to suit AF

Consumer unit solutions to meet the requirements of the new 17th edition amendment 3 regulations

QUALITY ASSURANCE & DOCUMENTATION

(1,5 modules per pole)

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Btdin RCBO 6000A up to 63A (2P)

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Jtec 10kA Miniature Circuit Breaker

DPX 630 Electronic release

max pole for t=15 ms

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

Electronic Circuit Breaker ESS20

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

The young energy ensures more safety

Residual Current Circuit-breaker (RCCB) FH 200 Series

Series KTU7 UL489 Molded Case Circuit Breakers

Using Electricity. Summary Notes. 1. From the Wall Socket Household appliances. Earth wire and safety.

DISTRIBUTION SOLUTIONS. GSec Gas-insulated switching and isolating apparatus

Record SL. Moulded Case Circuit Breaker

Rate (Rs.) in figure. Rate (Rs.) in words. VAT (%) Amount (Rs.) & all other taxes.

Contents. Acti 9 Isobar. A type distribution board features...page 1/2. B type distribution board features...page 1/3

ic60h (6kA) single module combined RCD/MCB units ic60h (10kA) single module combined RCD/MCB units ild residual current circuit breakers idpn N Vigi

and other modular devices for low voltage installation

DPX earth leakage DPX 3 -I earth leakage

Cat N 3. OVERALL DIMENSIONS

Transcription:

list effective 203Price 20th Dec, 203 aptis range

aptis range value for money Hager unveils its "value for money" offer - aptis! A range with required features and functionality for safe electrical installations. Built and launched around the concept of 3A's. Acceptability The range is packed with feature & benefits. It offers the best functional advantages, while complying to all mandatory standards. 2 Availability Available through out the country through our wide network of retailers. 3 Affordability Now experience world class offer to suit your budget.

aptis MCB Standard: IS / IEC 60898 Frequency: 50Hz ISI marked IEC 60898 Tripping Characteristics: Terminals: IP2X Terminal Rated Current: 6 63A 'C' Curve Capacity: 25sq mm rigid, Poles: P, 2P, 3P, 4P Breaking Capacity: 6000A 6sq mm flexible Rated Operating Voltage: Electrical Endurance: 0000 240 / 45V Operations Pack Pack Single Pole P 6A C Curve 6kA 2 Y06 49 P 0A C Curve 6kA 2 Y0 49 P 6A C Curve 6kA 2 Y6 49 P 20A C Curve 6kA 2 Y20 49 P 25A C Curve 6kA 2 Y25 49 P 32A C Curve 6kA 2 Y32 49 P 40A C Curve 6kA 2 Y40 380 P 50A C Curve 6kA 2 Y50 420 P 63A C Curve 6kA 2 Y63 420 Y0 Double Pole 2P 6A C Curve 6kA 6 Y206 525 2P 0A C Curve 6kA 6 Y20 525 2P 6A C Curve 6kA 6 Y26 525 2P 20A C Curve 6kA 6 Y220 525 2P 25A C Curve 6kA 6 Y225 525 2P 32A C Curve 6kA 6 Y232 525 2P 40A C Curve 6kA 6 Y240 860 2P 50A C Curve 6kA 6 Y250 935 2P 63A C Curve 6kA 6 Y263 935 Y20 Triple Pole 3P 6A C Curve 6kA 4 Y306 840 3P 0A C Curve 6kA 4 Y30 840 3P 6A C Curve 6kA 4 Y36 840 3P 20A C Curve 6kA 4 Y320 840 3P 25A C Curve 6kA 4 Y325 840 3P 32A C Curve 6kA 4 Y332 840 3P 40A C Curve 6kA 4 Y340 340 3P 50A C Curve 6kA 4 Y350 450 3P 63A C Curve 6kA 4 Y363 450 Y30 Four Pole 4P 6A C Curve 6kA 3 Y406 30 4P 0A C Curve 6kA 3 Y40 30 4P 6A C Curve 6kA 3 Y46 30 4P 20A C Curve 6kA 3 Y420 30 4P 25A C Curve 6kA 3 Y425 30 4P 32A C Curve 6kA 3 Y432 30 4P 40A C Curve 6kA 3 Y440 735 4P 50A C Curve 6kA 3 Y450 860 4P 63A C Curve 6kA 3 Y463 860 Y40 Stockable.

aptis RCCBs Standard: IS 2640-I, Sensitivity: 30, 00, 300mA Terminals: IP2X IEC 6008 RCCB type: AC Terminal Capacity: 25sq mm Rated Current: 25, 40, 63A Rated Residual Making & rigid, 6sq.mm flexible Rated Voltage: 230 / 45VAC Breaking capacity: 500A Poles: 2P, 4P ISI marked Y5232 Y5432 Double Pole 2P 25A 30mA Y5232 230 2P 25A 00mA Y5242 2400 2P 25A 300mA Y5252 2420 2P 40A 30mA Y5234 270 2P 40A 00mA Y5244 280 2P 40A 300mA Y5254 2840 2P 63A 30mA Y5236 3240 2P 63A 00mA Y5246 3300 2P 63A 300mA Y5256 3355 Four Pole Pack Pack 4P 25A 30mA Y5432 3070 4P 25A 00mA Y5442 385 4P 25A 300mA Y5452 3230 4P 40A 30mA Y5434 330 4P 40A 00mA Y5444 3230 4P 40A 300mA Y5454 3260 4P 63A 30mA Y5436 365 4P 63A 00mA Y5446 3750 4P 63A 300mA Y5456 3800 Isolating switches Conforms to IEC 60947-III AC22A devices used as switch disconnectors in electrical circuit Pack.. Double Pole 40A, 2 modules 63A, 2 modules 6 6 Y6240 Y6263 340 450 Triple Pole Y6240 40A, 3 modules 63A, 3 modules 4 4 Y6340 Y6363 585 680 Four Pole 40A, 4 modules 63A, 4 modules 3 3 Y6440 Y6463 755 825 Y6463 Stockable. 2

RCBO, RCD+MCB modules Standard: IEC 6009 Frequency: 50Hz Terminals: IP2X Terminal Rated Current: 6-63A Tripping Characteristics: Capacity: 25sq mm rigid, Sensitivity : 30,00 & 300 ma 'C' Curve 6sq mm flexible Poles: 2 pole and 4 pole Breaking Capacity: 0kA ISI marked Rated Operating Voltage: Earth fault indication 240 / 45V Positive contact indication Sensitivity Pack AD263Y Double Pole 6A, 4 modules 0A, 4 modules 6A, 4 modules 25A, 4 modules 32A, 4 modules 40A, 4 modules 63A, 4 modules 30 ma 00 ma 30 ma 00 ma 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma AD206Y AE206Y AD20Y AE20Y AD26Y AE26Y AF26Y AD225Y AE225Y AF225Y AD232Y AE232Y AF232Y AD240Y AE240Y AF240Y AD263Y AE263Y AF263Y 2925 3575 2925 3575 2925 3575 3630 2925 3575 3630 370 3575 3630 3685 3970 4090 4370 4635 4720 AD463Y Four Pole 6A, 7.5 modules 25A, 7.5 modules 32A, 7.5 modules 40A, 7.5 modules 63A, 7.5 modules 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma 30 ma 00 ma 300 ma AD46Y AE46Y AF46Y AD425Y AE425Y AF425Y AD432Y AE432Y AF432Y AD440Y AE440Y AF440Y AD463Y AE463Y AF463Y 4050 4530 4625 480 4440 4460 480 4440 4445 480 4425 4535 4970 500 550 Over voltage protection MCBs Reqd. OVR Reqd.* 25A single phase over voltage protection NCN225N 695 MZ209 235 32A single phase over voltage protection NCN232N 695 MZ209 235 40A single phase over voltage protection NCN240N 30 MZ209 235 63A single phase over voltage protection NCN263N 30 MZ209 235 40A three phase over voltage protection NCN440N 2220 MZ209 3 235 63A three phase over voltage protection NCN463N 2220 MZ209 3 235 MZ209 NCN225N *Single phase connections need one MZ209 and three phase connections need three MZ209 Stockable. 3

MCCBs thermal magnetic release Standard: IEC 60947-2 Frequency: 50Hz Complete range of 6 Frame sizes: X60, X250, Current limiting type ( A) accessories H250, H400/630, H000, Breaking Capacity: 8, 25, 40, International certification and H600 50, 65, 70 ka approvals Poles: 3 pole and 4 poles Calibrated at 50 C Thermal magnetic and Isolation marking electronic trip units Pack HDA25Z X60 frame MCCB fixed overload, fixed short circuit breaking capacity Icu : 8kA 6A, 3 pole HDA06Z 4080 20A, 3 pole HDA020Z 4080 25A, 3 pole HDA025Z 4080 32A, 3 pole HDA032Z 4080 40A, 3 pole HDA040Z 4000 50A, 3 pole HDA050Z 4080 63A, 3 pole HDA063Z 4080 80A, 3 pole HDA080Z 4080 00A, 3 pole HDA00Z 4080 25A, 3 pole HDA25Z 5050 60A, 3 pole HDA60Z 5455 6A, 4 pole HDA07Z 4690 20A, 4 pole HDA02Z 4690 25A, 4 pole HDA026Z 4690 32A, 4 pole HDA033Z 4690 40A, 4 pole HDA04Z 4690 50A, 4 pole HDA05Z 4690 63A, 4 pole HDA064Z 4690 80A, 4 pole HDA08Z 4690 00A, 4 pole HDA0Z 4690 25A, 4 pole HDA26Z 5305 60A, 4 pole HDA6Z 5765 HHA25Z X60 frame MCCB fixed overload, fixed short circuit breaking capacity Icu : 25kA 6A, 3 pole HHA06Z 5060 20A, 3 pole HHA020Z 5060 25A, 3 pole HHA025Z 5060 32A, 3 pole HHA032Z 5060 40A, 3 pole HHA040Z 5060 50A, 3 pole HHA050Z 5060 63A, 3 pole HHA063Z 5060 80A, 3 pole HHA080Z 5060 00A, 3 pole HHA00Z 5060 25A, 3 pole HHA25Z 6835 60A, 3 pole HHA60Z 855 6A, 4 pole HHA07Z 6905 20A, 4 pole HHA02Z 6905 25A, 4 pole HHA026Z 6905 32A, 4 pole HHA033Z 6905 40A, 4 pole HHA04Z 6905 50A, 4 pole HHA05Z 6905 63A, 4 pole HHA064Z 6905 80A, 4 pole HHA08Z 6905 00A, 4 pole HHA0Z 6905 25A, 4 pole HHA26Z 8825 60A, 4 pole HHA6Z 0700 Stockable. 4

MCCBs thermal magnetic release Pack HDA6U X60 frame MCCB overload adjustable 0.63-0.8- x I n short circuit fixed breaking capacity Icu : 8kA 25A, 3 pole HDA025U 4590 40A, 3 pole HDA040U 4590 63A, 3 pole HDA063U 4590 80A, 3 pole HDA080U 4590 00A, 3 pole HDA00U 4590 25A, 3 pole HDA25U 5460 60A, 3 pole HDA60U 6325 25A, 4 pole HDA026U 5300 40A, 4 pole HDA04U 5300 63A, 4 pole HDA064U 5300 80A, 4 pole HDA08U 5300 00A, 4 pole HDA0U 5300 25A, 4 pole HDA26U 6375 60A, 4 pole HDA6U 7090 HHA6U X60 frame MCCB overload adjustable 0.63-0.8- x I n short circuit fixed breaking capacity Icu : 25kA 25A, 3 pole HHA025U 5765 40A, 3 pole HHA040U 5765 63A, 3 pole HHA063U 5765 80A, 3 pole HHA080U 5765 00A, 3 pole HHA00U 5765 25A, 3 pole HHA25U 7040 60A, 3 pole HHA60U 8670 25A, 4 pole HHA026U 7800 40A, 4 pole HHA04U 7800 63A, 4 pole HHA064U 7800 80A, 4 pole HHA08U 7800 00A, 4 pole HHA0U 7800 25A, 4 pole HHA26U 980 60A, 4 pole HHA6U 220 HNA26U X60 frame MCCB overload adjustable 0.63-0.8- x I n short circuit fixed breaking capacity Icu : 40kA 25A, 3 pole HNA025U 740 40A, 3 pole HNA040U 740 63A, 3 pole HNA063U 740 80A, 3 pole HNA080U 740 00A, 3 pole HNA00U 740 25A, 3 pole HNA25U 8570 60A, 3 pole HNA60U 070 25A, 4 pole HNA026U 9485 40A, 4 pole HNA04U 9485 63A, 4 pole HNA064U 9485 80A, 4 pole HNA08U 9485 00A, 4 pole HNA0U 9485 25A, 4 pole HNA26U 0300 60A, 4 pole HNA6U 2240 Stockable. 5

MCCBs thermal magnetic release Pack X250 frame MCCB Over load fixed short circuit fixed Icu : 25 ka 200A, 3 pole HHB200Z 0450 250A, 3 pole HHB250Z 3055 200A, 4 pole HHB20Z 0865 250A, 4 pole HHB25Z 480 HNB00U Over load adjustable 0.63-0.8- x I n short circuit adjustable 6-8-0-3 x I (00-200A) n 5-7-9- x I n (250A) Icu : 40kA 00A, 3 pole HNB00U 7955 25A, 3 pole HNB25U 8875 60A, 3 pole HNB60U 730 200A, 3 pole HNB200U 2445 250A, 3 pole HNB250U 6780 00A, 4 pole HNB0U 0200 25A, 4 pole HNB26U 070 60A, 4 pole HNB6U 355 200A, 4 pole HNB20U 8055 250A, 4 pole HNB25U 20200 MCCBs accessories Pack X60 Frame MCCB HXA02H HXC024H Auxiliary Contact Alarm Contact Shunt 24V DC Shunt 230V AC UnderVoltage - 24V DC UnderVoltage - 240V AC UnderVoltage - 45V AC Direct Rotary Handle Extended Rotary Handle Spreaders - 3P Spreaders - 4P Phase barriers - 3P / 4P DIN Rail Adaptor Handle locking device HXA02H HXA024H HXA00H HXA004H HXA0H HXA04H HXA05H HXA030H HXA03H HYA04H HYA05H HYB09H HYA033H HXA039H 85 85 685 685 2040 2040 2040 020 430 425 580 55 285 850 X250 Frame MCCB HXA04H HXB042H Auxiliary Contact Alarm Contact Shunt 24V DC Shunt 230V AC UnderVoltage - 24V DC UnderVoltage - 240V AC UnderVoltage - 45V AC Direct Rotary Handle Extended Rotary Handle Motor Operator 240VAC Spreaders - 3P Spreaders - 4P Phase barriers - 3P / 4P HXA02H 85 HXA024H 85 HXA00H 685 HXA004H 685 HXA0H 2040 HXA04H 2040 HXA05H 2040 HXB030H 070 HXB03H 580 HXB042H 7800 HYB0H 490 HYB02H 665 HYB09H 55 Stockable. 6

Indicating lights (LED) Standard : IEC 62094- Light : LED type Life : 00,000 burning hours Modular design, Fits on 35mm DIN Channel Triple Indicators for RYB & ON-OFF-TRIP (RGO) in single module Pack SVN222 SVN26 Green, module Red, module Orange, module Blue, module Red+Green indicator, module Red+Green+Orange indicator, module Red+Orange+Blue (RYB) indicator, module 2 2 2 2 2 2 2 SVN2 SVN22 SVN23 SVN24 SVN26 SVN29 SVN222 640 640 640 640 825 75 75 2 way centre off changeover switches Standard : IEC 60947 Ratings : 25A & 40A No. of Poles : 2P & 4P 3 Positions (I 0 II) with centre off Utilization category AC2A Mounting on 35mm DIN channel Pack. Double Pole 25A, 2 modules 40A, 2 modules SFT225N SFT240N 445 295 SFT240N Four Pole 40A, 4 modules SFT440N 3775 Automatic Changeover with Current Limiter IEC 60947-3, IEC 60947-6 SPN Modular Voltage: 50VAC to 300VAC 6000 Operations IP 2X finger touch proof Different LED colors for clear differentiation between functions Blinking LED for overload and permanent LED for overload Trip Modular design Convenient and simple wiring terminal design No reset required if Main supply resumes on genset reset RoHS compliant, CE Marking Pack. SPN Version Mains 30A, Genset.5A Mains 30A, Genset 2.5A Mains 30A, Genset 3A Mains 30A, Genset 4A Mains 30A, Genset 5A Mains 30A, Genset 6A Mains 30A, Genset 9A Mains 30A, Genset 2A Mains 30A, Genset 5A Mains 30A, Genset 20A Mains 30A, Genset 30A EKS30B EKS302B EKS303B EKS304B EKS305B EKS306B EKS309B EKS32B EKS35B EKS320B EKS330B 740 740 740 740 740 740 740 740 740 740 740 Stockable. 7

aptis SPN distribution boards Single Door Double Door Standard Accessories: - Wires sets - Insulated busbars - Insulated neutral bars & earth bar - Circuit identification labels Pack.. Single Door DBs 4 way, 4 modules Y804 600 6 way, 6 modules 8 way, 8 modules 2 way, 2 modules 6 way, 6 modules Y806 Y808 Y82 Y86 700 850 000 240 Y808 Pack. plain door Double Door DBs 4 way, 4 modules 6 way, 6 modules 8 way, 8 modules 2 way, 2 modules 6 way, 6 modules Y8042 Y8062 Y8082 Y822 Y862 950 050 80 400 770 Y822 aptis TPN distribution boards Single Door Double Door 8 module Incomer & SP MCBs as outgoing Standard Accessories: - Wires set - Insulated busbars - Insulated neutral bars & earth bar - Circuit identification labels Pack.. Single Door DBs (Incomer + Outgoing Modules) 4 way, 8+2 modules Y8204 6 way, 8+8 modules Y8206 8 way, 8+24 modules Y8208 2 way, 8+36 modules Y82 860 2300 2700 3960 Y8204 Pack.. Double Door DBs (Incomer + Outgoing Modules) 4 way, 4+2 modules 4 way, 8+2 modules 6 way, 8+8 modules 8 way, 8+24 modules 2 way, 8+36 modules Y82043 2270 Y82042 Y82062 Y82082 Y8222 2350 2830 3450 500 Y82062 8

aptis one way enclosures IP30 degree of protection Pack.. 2 way, 2 modules 4 way, 4 modules Y8302 Y8304 335 350 Y8304 aptis plug & socket outlets-metal Supplied with metal plug & socket, provision to mount MCBs Pack.. 0A 2 Pin, modules 20A 2 Pin, modules 20A 2 Pin, 2 modules 20A 3 Pin, 4 modules 32A 3 Pin, 4 modules Y840 Y8420 Y84220 Y84420 Y84432 900 950 050 800 200 Y84220 * SC - Scraping Earth cosmos enclosures Standard: IEC 6439-3 Type of Door: Transparent Glow wire test: 960 C for load Colour: RAL 900 (pure white) Door carrying parts, 650 C for other Number of Rows: Row Installation: Surface or flush insulated parts Modules: 4 Module to 8 Module IK Rating: IK 07 Pack VS8TVA Stockable. 9

Electromechanical time switches Standard: IEC 60730 Programming by captive segments Battery reserve of 200 hrs. Manual over ride function Sealing of cover to avoid unwanted modifications Pack.. Quartz channel daily dial module Quartz channel daily dial 3 modules Quartz channel daily dial Quartz channel weekly dial EH0 EH EH7 EH77 2420 2470 2325 2630 EH7 Movement and presence detectors-ceiling mounted To automatically switch on-off loads based upon human presence Movement detectors Inbuilt ambient light sensor with adjustable lux level 5 to 000 lux adjustable time delay upto 5 mins Presence detectors Inbuilt ambient light sensor with adjustable lux level 5 to 200 lux adjustable time delay upto Hr Pack. EE80 Movement detectors Single lens, 360 deg., 6m dia detection 0A AC, channel, surface mounted Single lens, 360 deg., 6m dia detection 0A AC, channel, flush mounted Presence detectors Dual lens, 360 deg., 3m x 7m detection 6A AC, channel, surface mounted Dual lens, 360 deg., 3m x 7m detection 6A & 2A AC, 2 channels, surface mounted EE804 EE805 EE80 EE8 45 45 7780 8960 Stockable. 0

Selection chart for typical domestic loads S.No. Items Load/Wattage MCB rating Fan 60W * 2 Lamp, Tubelight 40W * 3 Room Heater 200W A 4 Water Heater 8 ltrs 200-2000W 0 A 5 ltrs 3000-4000W 20 A 60 ltrs 4000-6000W 32 A 5 Immersion Heater 000W 6 A 6 Hot Plate-single 000W 6 A 7 Iron-Nonautomatic 500W 3 A Automatic 000W 6 A 8 Mixer / Juicer 300W 2 A 9 TV / VCR / VCP 200W A 0 Music system 200W A Refrigerator 65 ltrs 400W 3 A 285 ltrs 600W 4 A 350 ltrs 750W 6 A 2 Toaster 500W 3 A 3 Vacuum Cleaner 400W 3 A 4 Washing Machine without heater 300-300W 0 A with heater 5000-6300W 32 A 5 Water Cooler 700W 6 A 6 Desert Cooler 300W 2 A 7 Oven 750W 6 A 8 Electric Kettle 500W 7.5 A 9 Air Conditioner ton 000W 0 A.5 ton 500W 6 A 2 ton 2000W 6 A 20 Hair Dryer 000W 7.5 A 2 Microwave 800W 6 A Formula for Calculations : Incomer Rating : Single Phase = Total Load in Watts 230 volts x cos Ø Three Phase = Total Load in Watts 3 x 45 volts x cos Ø * The given data is only for guidance and may vary for different manufacturers.

Capacities of PVC conduits Cable Size Conduit Size and Gauge Nominal Conductor Size mm² 6mm or 5/8" 20mm or 3/4" 25mm or " 32mm or ¼" Number of Cables (maximum).0 6 7 9 30.5 5 5 5 24 2.5 3 4 7 4 2 3 8 3 6 2 2 6 0 0 - - 4 6 6 - - 3 4 25 - - 2 3 35 - - - 2 50 - - - - Data given above are for guidance and may vary for different manufacturer. Cable selection chart Single core cable (Flexible) voltage grade 00 V, conforming to IS : 694-990 Nominal Current carrying Max. Resistance area of capacity per km. at 20ºC conductor as per IS:396 Sq. mm. Amp. Ohms.0 9.50.5 4 3.30 2.5 9 7.98 4.0 26 4.95 6.0 3 3.30 0 42.9 6 57.2 25 7 0.78 Data given above are for guidance and may vary for different manufacturer. 2

Over voltage Protection Permanent over voltage is a common problem faced by users due Hager MZ209 continuously monitors the voltage between phase to external or internal factors. Over voltage is caused due to and neutral conductors. As the voltage increases beyond 267VAC following: (240VAC + 0%), MZ209 immediately disconnects the power - Over voltage from electricity board supply through the connected MCB thus avoiding the damage to the equipments. This ensures safety both in case of presence and - Loss of neutral or loose neutral wire termination absence of people at home. - Wrong Connection like Interchange of P & N conductors in RYBN wire - Harmonics Phase Phase voltage during loss of neutral Safety to human and expensive electronic equipments Connections: MZ209 is mechanical connected with mcb and does not need any tool for coupling with the MCB. Electrical connections are made with small size wire of sqmm from Phase and Neutral conductors in parallel. Phase and Neutral can be connected to either side of MZ209 and only one number per phase is required for protection against over voltage problems. R N R Y B N Hager MZ209 U>280V 2P, MCB, Hager Hager MZ209 U>280V U>280V U>280V 4P, MCB, Hager Single Phase connections Three Phase connections 3

Modular indication lights, Changeover switches and isolators Modular Indication Lights Modular LED Indicators provide the visual indication of power supply (-Phase, 3- Phase, Mains & Genset) and status of Modular devices like ON, OFF or Trip. Modular LED indication lights avoids the hassle of making cut out in distribution boards by their easy installation on the DIN channel. Changeover switches Changeover switches are used to shift from one source of supply to another source, and vice versa. Hager modular changeover switch is a compact device which can be mounted on a standard DIN channel inside an enclosure. Its design is compatible with all other hager modular devices, such as MCBs and RCCBs. The changeover switch comes in 2P and 4P versions, for single and three phase applications, respectively. It has three positions (I - O - II) with centre-off position. The incoming side must be protected against short circuits. For isolation, use it with an appropriate MCB. Standard : Conforms to IEC 60947 Part I Ratings - 25A & 40A No. of poles - 2P & 4P 3 positions (I - O - II) with centre OFF Utilization category - AC 2A Isolators The simple and safe-to-install switch disconnectors (isolators) from Hager help to make your work easier and ensure absolute safety of electrical installations. All devices are manufactured in compliance with the latest IEC standards and are CE marked. They are particularly easy and safe to install. Standard : Conforms to IEC 60947 - Part III Ratings - 25A, 32A, 40A, 63A & 00A No. of poles - 2P, 3P & 4P Utilization category - AC 22 IEC & CE approved 4

aptis SPN DBs Single Door Double Door 5

aptis TPN DBs Single Door Double Door 6

aptis One way enclosure Metal Plug & Socket 7

cosmos enclosures Standard: IEC 6439-3 Installation: Surface or flush Colour: RAL 900 (pure white) IK Rating: IK 07 Number of Rows: Row Glow wire test: 960 C for load carrying parts, 650 C for other Modules: 4 Module to 8 Module insulated parts Type of Door: Transparent Door Dimensions H (mm) H2 (mm) VF04 43.0 23.0 VF08 25.0 95.0 VF2 306.6 286.6 H (mm) VS04 37.0 VS08 20.0 VS2 30.5 VS8 409.5 H (mm) H2 (mm) H4 (mm) VS04 52.0 5.5 77.0 VS08 5.0 6.5 36.0 VS2 36.0 29.0 259.5 VS8 9.5 32.0 369.5 8

Terms & Conditions This price list supercedes all previous price list All prices are ex-godown and in Indian Rupees & inclusive of excise duty / countervailing duty, VAT / sales tax as applicable M.R.P. prices are maximum retail price Prices are subject to revision without notice. All dispatch will be as per price prevailing on the date of invoice Enclosures / Distribution Boards have the provision for fixing the component as shown in the photograph Warranty Policy All the products listed in the price list carry a warranty, against manufacturing defects for a period of 24 months from the date of manufacturing The warranty is however subject to provision of proper usage, efficient maintenance and does not cover defects arising out inefficient maintenance, faulty operation and willful or accidental damage including nonperformance, which is caused by an event constituting Force Majeure, i.e. including (but not limited to) pandemic, fire, floods, administrative orders etc. Hager and / or manufacturer shall not be liable for any consequential loss, including personal injury or damages arising out of, or in connection with, defects in the Products including claim by third party Proof of purchase to be retained to avail warranty 9

Hager Electro Private Limited Sales & Marketing office : Office 2A, First Floor North Court Building Opposite Joggers Park Kalyani Nagar Pune-4006 India Delhi Sales Office : B 27 Tower B DLF Towers, Jasola New Delhi-0025 India Mumbai Sales Office : Office # 30A, Tower 3 Indiabulls Finance Centre Elphistone Road Mumbai India Tel: +9 20 4477500 Fax: +9 20 447750 Toll free no.: 800 03 5440 Email: hagerwow@hager.co.in Website: www.hager.co.in Tel: +9 49677500 Fax: +9 49677555 Tel: +9 22 783200 Hager Electro SAS: 32 Boulevard d` Europe BP 78 F-6722 OBERNAI FRANCE