ABB STOTZ-KONTAKT GmbH

Similar documents
and other modular devices for low voltage installation

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

Residual current devices

System pro M compact Miniature Circuit Breaker SU200 M for branch circuit protection acc. to UL 489

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

The effective choice The benefits of a product with the highest quality standards

DSE201 Compact design with enhanced protection

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Electronic overload relays EF205 and EF370

NB1 Miniature Circuit Breaker

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Electronic overload relay EF65, EF96 and EF146

Thermal overload relay TF65 and TF96

RX 3 M.C.B A up to 63 A

Technical catalogue. System pro M. Residual current devices 2CSC420001D0201

RX 3 M.C.B A up to 63 A

Miniature circuit-breaker (MCB) SH200M Series

MS General Information Extended Product Type: MS

Selective main circuit breakers S 750 series Technical Data

System pro M. Technical catalogue. Miniature circuit-breakers 2CSC400001D0201

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Technical Data. Miniature circuit-breakers for branch circuit protection according to UL 489, CSA C 22.2 No. 5

EKM1-63S MCB Mini Circuit Breaker

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

SH 200 T SH 200 L SH 200 Mechanical Toggle

Residual Current Circuit-breaker (RCCB) FH 200 Series

Thermal overload relay TF140DU and TF140DU-V1000

Low Voltage A GE Power Controls Company. General catalogue

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

Phase + Neutral, neutral on left side

Technical data. Miniature Circuit Breakers. System pro M. System pro M

W DATASHEET: MINIATURE CIRCUIT BREAKER (MCB), SERIES AMPARO

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

TX³ RCCBs 2P up to 100 A

Btdin RCBO 6000A up to 63A (2P)

Short-circuit current limiter S800-SCL-SR

Instantaneous tripping TYPE B, C, D TYPE B, C TYPE B, C, D TYPE B, C IEC RCCB TYPE C IEC61008 RCBO 25, 40, 63A. IEC61009 Isolating Switch

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Multi 9 TM. Catalogue 2017 Multistandard protection for OEM. schneider-electric.com

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on right side

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

Control Circuit Protection

DX³ RCCBs - ID 4P up to 100 A

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

Manual motor starter magnetic only MO325

Mini contactors B6, BC6 with 3 pole

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

ELFA E90S MINI BREAKERS

AF40... AF96 3-pole contactors Technical data

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

The new SH200 MCBs can be used in domestic, commercial and industrial applications for protection against over-current and short circuit.

W Datasheet: Residual current circuit breaker, series PRIORI, 10kA, Typ B

up to 63 A (1 module per pole)

Thermal-Magnetic Circuit Breaker 2210-S291-P9M A

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

ASL09..S 3-pole Contactors - Spring Terminals

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

Maximum safety and easy installation

GE Consumer & Industrial Power Protection. New. ElfaPlus Unibis. Compact MCB s. Saving up to 50% space in distribution boards. GE imagination at work

B Mini Contactor V Hz

Series L9 UL489 Miniature Circuit Breakers

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left

Cat N 3. OVERALL DIMENSIONS

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

COMBINATION CIRCUIT BREAKERS RCBO

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

1489-M Circuit Breakers

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

249.1 m3/h m3/h 7.23 MW m3/h 50.0 m3/h

Manual motor starter MS132

DX³ 4-pole RCBO 6000 A/10 ka

BETA Switching Switches and Light Indicators

Series KTU7 UL489 Molded Case Circuit Breakers

INDUSTRIAL POWER SUPPLIES SFL-SERIES

DPX Magnetic only

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Motorized switch-disconnectors OTM 40 to 125 Amperes

FMotor Circuit Controllers

Thermal Overcurrent Circuit Breaker 3120-F...

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Manual motor starter MS116

Manual motor starter MS116

max pole for t=15 ms

MINIATURE CIRCUIT BREAKER

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Transcription:

ABB STOTZ-KONTAKT GmbH MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net

PAGE : 02 The ABB Line Protection Devices quality system is conforming with the ISO 9001 Vision 2000 international Standard (model for quality assurance as regards design, development, construction, installation and service) and to the equivalent EN ISO 9001 European Standard. ABB commitment to protecting the environment is also shown in concrete way by the Life Cycle Assessments of the products, which is being realized directly by ABB Research and Development. All the products of Compact Home range are conforming to the European standards 2002/95/CE regarding the restrictions on the use of certain dangerous substances in the electrical and electronical equipments. It is necessary to respect the local regulations concerning the elimination of the packaging materials and of the circuit-breakers and, if possible, to recycle them. The symbol marked on the product means that the circuit breaker must not be eliminated together with the general litter.

All Compact Home devices comply to European and international product standards: IEC/EN 61008 (RCCBs) IEC/EN 61009 (RCBOs) IEC/EN 60898 (MCBs) IEC/EN 60947-3 (Switches) IEC/EN 60669-1 (Dimmers) IEC/EN 61643-11 (SPDs) IEC/EN 60730-1 (Timers) IEC/EN 61558-1-2-8 (Transformers) IEC/EN 60439-1 (Busbars) They are also conforming to the following EC directives: Low Voltage Directives (LVD) no. 73/23 EEC Electromagnetic Compatibility Directive (EMC) no.89/336 EEC and 92/31 EEC CE marking of Compact Home devices warrants free circulation and sale in European Union. It is realized on supplier s responsibility, in addition to this marks and approvals, guarantee functioning, compatibility and safety conforming to national and international Standards. ABB Compact Home RCDs also obtained the following national and international approvals: AENOR- ES APCER- PT SIRIM- MY LCIE- FR GOST- RU TICKMARK- AU CCC- CN SABS - ZA PSB - SG Thanks to these approvals, the devices can be used without restriction as devices for the world market. PAGE : 03

SH 200 Technical Features of MCBs SH 200 series SH 200 T SH 200 L SH 200 Electrical features Mechanical features Installation Dimensions and weigh Standards IEC/EN 60898 Rated current in A 6-40 Poles 1, 2, 3, 4, 1+NA, 3+NA Rated Voltage Ue IEC 1P, 1P+N V 230 IEC 2P, 3P, 3P+N, 4P V 230/400 Insulation voltage Ui V 250 Max. operating voltage Ub max. IEC AC V 254/440 Min. operating voltage Ub min. V 12 V AC - 12 V DC Rated frequency Hz 50 60 Rated breaking capacity acc. to IEC/EN 60898 ultimate Icn A 3000 4500 6000 Rated impulse withstand voltage (1.2/50) Uimp KV 4 (test voltage 6,2. at sea level Dielectric strength at power freq. for 1 min. KV 5 at 2000 m) 2,5 Overvoltage category III Pollution degree 2 T hermomagnetic release B: 3 In Im 5 In c haracterisitic C: 5 In Im 10 In Toggle black sealable in ON-OFF position Electrical life 10000 Mechanical life/operations 20000 Protections degree/operations housing IP4X terminals IP2X Mechanical shock resistance 30 g - 2 shocks - duration 11 ms Resistance to vibrations acc. to IEC/EN 60060-2--6 5 g - 20 cycles at frequency Tropicalization humid heat C/RH 5 150 5 Hz with 0,8 x In 28 cycles with 55/95 100 acc. to IEC/EN 60068-2 constant climatic conditions C/RH 23/28-40/93-55/20 variable climatic conditions C/RH 25/95-40/95 Reference temperature for setting of thermal element C 30 Ambient temperature (with daily averages +35 C) IEC C -25 +55 Storage temperature C -40 +70 Terminal type cage terminal Terminal size top/bottom for cable IEC 2 mm 25/25 UL/CSA AWG 18-4 Tightening torque IEC N*m 2.5 UL/CSA in-lbs. 22 Tool Nr. 2 Pozidriv Mounting on DIN rail EN 60715 (35 mm) by means of fast clip device Mounting position optional Connection from top and bottom Pole dimensions (H x D x W) mm 85 x 69 x 17.5 Pole weight g 125 Tripping diagrams 2CDC022188F0205 2CDC022190F0205 PAGE : 04 Tripping characterisitc B acc. to DIN VDE 0641 part 11 In = 6 40 A SH 200 T / SH 200 L / SH 200 Tripping characterisitc C acc. to DIN VDE 0641 part 11 In = 0.5 40 A SH 200 T / SH 200 L / SH 200

Internal resistances and power losses of the Miniature Circuit-Breakers Internal resistances per pole in m Power losses per pole in W Type Rated Range SH 200 T Range SH 200 L Range SH 200 current B, C B, C B, C A m W m W m W SH 200 6 55 2.0 55 2.0 55 2.0 8 15 1.0 15 1.0 15 1.0 10 13.3 1.3 13.3 1.3 13.3 1.3 13 13.3 2.3 13.3 2.3 13.3 2.3 16 7.0 1.8 7.0 1.8 7.0 1.8 20 6.25 2.5 6.25 2.5 6.25 2.5 25 5.0 3.2 5.0 3.2 5.0 3.2 32 3.6 3.7 3.6 3.7 3.6 3.7 40 3.0 4.8 3.0 4.8 3.0 4.8 Tripping characteristics Thermal trips Electromagnetic trips acc. to Tripping Test currents: Tripping- Test currents: Trippingcharacterisitic Low test High test time hold current trip time current current surges of at least at I 1 I 2 IEC/EN 60898 B C 1.13 I n > 1 h 3 I n 0.1 s 45 s 32 A / 0.1 s 90 s 32 A 1.45 I n < 1 h 5 I n < 0,1 s 1.13 I n > 1 h 5 I n 0.1 s 45 s 32 A / 0.1 s 30 s 32 A 1.45 I n < 1 h 10 I n < 0,1 s Influence of ambient temperature see below. The tripping for the electromagnetic trip are valid for AC 50 60 Hz. For other frequencies see table below. From warm operating condition (After I 1 > 1 h resp. 2 h) Influence of frequency on electromagnetic trips Influence of ambient temperature The stated tripping values of the electromagnetic trips are valid for a frequency of 50 60 Hz. In case of frequencies deviating from 50 60 Hz as well as direct current the tripping values are changed by the factor mentioned below. AC DC 100 Hz 200 Hz 400 Hz Factor approx. 1.1 1.2 1.5 1.5 The thermal trips are calibrated for an ambient temerpature 30 C for B- and C-characteristic. In the case of temperatures deviating from these values the tripp values are reduced in case of higher temperatures are increased in case of lower temperatures The tripping values of the thermal trips are independent of the frequency The electronic tripping is not dependent on temperature PAGE : 05

C SH 200 T C characteristic Function: protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. Applications: buildings, both residential and commercial Standard: IEC/EN 60898 Icn=3kA No. of rated order details bbn price price w'ght pack. poles current 40 16779 1 piece group 1 pc. unit I n A type code order code EAN kg pc. 1 6 SH 201 T-C 6 2CDS 231 001 R0064 63191 4 0.125 10 8 SH 201 T-C 8 2CDS 231 001 R0084 63193 8 0.125 10 10 SH 201 T-C 10 2CDS 231 001 R0104 63194 5 0.125 10 13 SH 201 T-C 13 2CDS 231 001 R0134 63196 9 0.125 10 16 SH 201 T-C 16 2CDS 231 001 R0164 63198 3 0.125 10 20 SH 201 T-C 20 2CDS 231 001 R0204 63200 3 0.125 10 25 SH 201 T-C 25 2CDS 231 001 R0254 63202 7 0.125 10 32 SH 201 T-C 32 2CDS 231 001 R0324 63204 1 0.125 10 60 V... 40 SH 201 T-C 40 2CDS 231 001 R0404 63206 5 0.125 10 2 6 SH 202 T-C 6 2CDS 232 001 R0064 63225 6 0.25 5 8 SH 202 T-C 8 2CDS 232 001 R0084 63227 0 0.25 5 10 SH 202 T-C 10 2CDS 232 001 R0104 63228 7 0.25 5 13 SH 202 T-C 13 2CDS 232 001 R0134 63230 0 0.25 5 16 SH 202 T-C 16 2CDS 232 001 R0164 63232 4 0.25 5 20 SH 202 T-C 20 2CDS 232 001 R0204 63234 8 0.25 5 25 SH 202 T-C 25 2CDS 232 001 R0254 63236 2 0.25 5 440 V~ 125 V... 32 SH 202 T-C 32 2CDS 232 001 R0324 63238 6 0.25 5 40 SH 202 T-C 40 2CDS 232 001 R0404 63240 9 0.25 5 3 6 SH 203 T-C 6 2CDS 233 001 R0064 63242 3 0.375 1 8 SH 203 T-C 8 2CDS 233 001 R0084 63244 7 0.375 1 10 SH 203 T-C 10 2CDS 233 001 R0104 63245 4 0.375 1 13 SH 203 T-C 13 2CDS 233 001 R0134 63247 8 0.375 1 16 SH 203 T-C 16 2CDS 233 001 R0164 63249 2 0.375 1 20 SH 203 T-C 20 2CDS 233 001 R0204 63251 5 0.375 1 25 SH 203 T-C 25 2CDS 233 001 R0254 63253 9 0.375 1 32 SH 203 T-C 32 2CDS 233 001 R0324 63255 3 0.375 1 40 SH 203 T-C 40 2CDS 233 001 R0404 63257 7 0.375 1 4 6 SH 204 T-C 6 2CDS 234 001 R0064 63276 8 0.5 1 8 SH 204 T-C 8 2CDS 234 001 R0084 63278 2 0.5 1 10 SH 204 T-C 10 2CDS 234 001 R0104 63279 9 0.5 1 13 SH 204 T-C 13 2CDS 234 001 R0134 63281 2 0.5 1 16 SH 204 T-C16 2CDS 234 001 R0164 63283 6 0.5 1 20 SH 204 T-C20 2CDS 234 001 R0204 63285 0 0.5 1 25 SH 204 T-C25 2CDS 234 001 R0254 63287 4 0.5 1 125 V... 32 SH 204 T-C32 2CDS 234 001 R0324 63289 8 0.5 1 40 SH 204 T-C 40 2CDS 234 001 R0404 63291 1 0.5 1 125 V... with 2 poles connected in series PAGE : 06

C SH 200 C characteristic Function: protection and control of the circuits against overloads and short-circuits; protection for resistive and inductive loads with low inrush current. Applications: buildings, both residential and commercial Standard: IEC/EN 60898 Icn=6kA No. of rated order details bbn price price w'ght pack. poles current 40 16779 1 piece group 1 pc. unit I n A type code order code EAN kg pc. 1 6 SH 201-C 6 2CDS 211 001 R0064 63057 3 0.125 10 8 SH 201-C 8 2CDS 211 001 R0084 63059 7 0.125 10 10 SH 201-C 10 2CDS 211 001 R0104 63060 3 0.125 10 13 SH 201-C 13 2CDS 211 001 R0134 63062 7 0.125 10 16 SH 201-C 16 2CDS 211 001 R0164 63064 1 0.125 10 20 SH 201-C 20 2CDS 211 001 R0204 63066 5 0.125 10 25 SH 201-C 25 2CDS 211 001 R0254 63068 9 0.125 10 32 SH 201-C 32 2CDS 211 001 R0324 63070 2 0.125 10 60 V... 40 SH 201-C 40 2CDS 211 001 R0404 63072 6 0.125 10 2 6 SH 202-C 6 2CDS 212 001 R0064 63103 7 0.25 5 8 SH 202-C 8 2CDS 212 001 R0084 63105 1 0.25 5 10 SH 202-C 10 2CDS 212 001 R0104 63106 8 0.25 5 13 SH 202-C 13 2CDS 212 001 R0134 63108 2 0.25 5 16 SH 202-C 16 2CDS 212 001 R0164 63110 5 0.25 5 20 SH 202-C 20 2CDS 212 001 R0204 63112 9 0.25 5 25 SH 202-C 25 2CDS 212 001 R0254 63114 3 0.25 5 125 V... 32 SH 202-C 32 2CDS 212 001 R0324 63116 7 0.25 5 40 SH 202-C 40 2CDS 212 001 R0404 63118 1 0.25 5 3 6 SH 203-C 6 2CDS 213 001 R0064 63126 6 0.375 1 8 SH 203-C 8 2CDS 213 001 R0084 63128 0 0.375 1 10 SH 203-C 10 2CDS 213 001 R0104 63129 7 0.375 1 13 SH 203-C 13 2CDS 213 001 R0134 63131 0 0.375 1 16 SH 203-C 16 2CDS 213 001 R0164 63133 4 0.375 1 20 SH 203-C 20 2CDS 213 001 R0204 63135 8 0.375 1 25 SH 203-C 25 2CDS 213 001 R0254 63137 2 0.375 1 32 SH 203-C 32 2CDS 213 001 R0324 63139 6 0.375 1 40 SH 203-C 40 2CDS 213 001 R0404 63141 9 0.375 1 4 6 SH 204-C 6 2CDS 214 001 R0064 63172 3 0.5 1 8 SH 204-C 8 2CDS 214 001 R0084 63174 7 0.5 1 10 SH 204-C 10 2CDS 214 001 R0104 63175 4 0.5 1 13 SH 204-C 13 2CDS 214 001 R0134 63177 8 0.5 1 16 SH 204-C 16 2CDS 214 001 R0164 63179 2 0.5 1 20 SH 204-C 20 2CDS 214 001 R0204 63181 5 0.5 1 25 SH 204-C 25 2CDS 214 001 R0254 63183 9 0.5 1 125 V... 32 SH 204-C 32 2CDS 214 001 R0324 63185 3 0.5 1 40 SH 204-C 40 2CDS 214 001 R0404 63187 7 0.5 1 125 V... with 2 poles connected in series PAGE : 07

MULTIPLE 89 Motijheel C/A, Lucky Chamber (3rd floor, Room #61), Dhaka-1000, Bangladesh. Tel: (02) 9559692, Fax: (02)9566596 E-mail: info@multipletrading.net